• Title/Summary/Keyword: Matrix addition

Search Result 2,032, Processing Time 0.033 seconds

Evaluated the L-spine Magnetic Resonance Imaging for the Scanning Method of the Lateral Recumbent Position with to the Embarrassed Control of the Acute Low Back Pain (자기공명검사에서 통증제어가 불가능한 급성 요통 환자의 옆으로 누운 자세에 대한 영상평가)

  • Lee, Jaeheun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.255-260
    • /
    • 2014
  • The acute lumbar pain patients who were unavoidable to take MRI examination were made to take altered lateral recumbent position. they were also not able to control their painfulness and to be in supine position. In this study, it is supposed to increase success rate of the MRI examination through taking the altered lateral recumbent position in using spine and body matrix coil. This altered position made relaxing lumber pain and fatigue for the patients who suffered from sever lumber pain. In these reasons, it decreases the motion artifacts through correcting uncomfortable posture. As a result, qualitative analysis for the image quality was estimated to have average points of supine position A group(lateral recumbent position) of normal candidates and B group(lateral recumbent position) of the abnormal candidates who have sever pain at 4.64, 3.44, and 3.40, respectively. In conclusion, while qualitative analysis in the examination with supine position of the normal patients had significantly high points, the qualitative analysis in the examination with lateral recumbent position of the normal patients and abnormal patients who had sever lumbar pain was almost same. In addition, it was judged that radiologists' imagery interpretation had no other problems in the image evaluation of B group who had acute lumbar pain of abnormal patients. Hereupon, if this technique becomes generalized for the patients who suffer from supine position in the examination, it is supposed to be useful in medical field.

Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension (금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량)

  • Han, Chul-Woo;In, Gyo;Choi, Jong-Moon;Kim, Sun Tae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.608-615
    • /
    • 2000
  • A determination method of trace nickel and cobalt in water samples was studied and developed by adsorbing their complexes on ion exchange resin suspension. The analytical ions were formed as complexes with a ligand of APDC (ammonium pyrrolidinedithiocarbamate) and adsorbed on anion exchange resin of Dowex 2-X8. After the suspension was filtered out with membrane filter, the complexes were dissolved in HCl solution by an ultrasonic vibrator for ET-AAS determination. Several conditions were optimized as followings. pH of sample solution: 5.0, amount of ligand APDC: more than 430 times in mole ratio, the type and concentration of acid: 0.1 M HCl, and vibration time: 7 minutes. The addition of palladium in the HCl solution could improve the reproducibility and sensitivity by a matrix modification in the absorbance measurement. This procedure was applied for the analysis of three kinds of real water samples. The detection limits equivalent to 3 times standard deviation of blank were Co 0.36 ng/mL and Ni 0.27 ng/mL and recoveries in spiked samples were 99-102% for cobalt and 100-105% for nickel.

  • PDF

Preliminary study on geochemical elements concentration changes in coral skeleton from Chuuk, Micronesia (마이크로네시아 축 경산호 골격의 지화학 원소 농도에 대한 예비연구)

  • Hyun, Sang-Min;Park, Heung-Sik;Kim, Su-Hyun;Kim, Han-Jun;Jang, Suk
    • The Korean Journal of Quaternary Research
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • We investigated metal concentrations and oceanic environment changes that have occurred over the past several years by studying the hard coral Porites lutea, which inhabits tropical and subtropical areas. Soft X-radiographs clearly showed distinctive annual bands within 71 mm coral sample, which reflect changes in the oceanic environment over this period. There were large fluctuations in the major and minor element concentrations. Considering the physicochemical partition coefficient, some elements accumulated in the aragonite matrix in a mechanical manner, while others were affected by environmental factors. The concentrations of some heavy metals varied over a wide range, implying local environmental effects. The variation of Sr/Ca and Mg/Ca in coral skeleton clearly showed large-scale fluctuation over the specific intervals, implying environmental changes during this period. The concentrations of heavy metals also show high fluctuations, and roughly accord with Mg/Ca variation. In addition, Cu and Zn seem to show cyclicity-like peaks, coincide with Mg/Ca variation over the specific intervals. Such variation might be related to local pollution and oceanographic changes. More detailed investigation is necessary, including the pretreatment of coral skeleton sediment.

  • PDF

Removal of Microcystis aeruginosa using polyethylenimine-coated alginate/waste biomass composite biosorbent (양이온성 고분자(polyethylenimine)가 코팅된 알지네이트/폐바이오매스 복합 흡착소재를 사용한 유해 미세조류 Microcystis aeruginosa의 제거)

  • Kim, Hoseon;Byun, Jongwoong;Choi, In Tae;Park, Yun Hwan;Kim, Sok;Choi, Yoon-E
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.741-748
    • /
    • 2019
  • As the occurrence of harmful algal blooms (HABs) have become severe in precious water resources, the development of efficient harmful algae treatment methods is considering as an important environmental issue for sustainable conservation of water resources. To treat HABs in water resources, various conventional physical and chemical methods have been utilized and showed treatment efficiency, However, these methods can lead to discharging of cyanotoxins into the water bodies by chemical or physical algal cell lysis or destruction. Thus, to overcome this limitation, the development of safe HABs treatment methods is required. In the present study, adsorption technology was investigated for the removal of harmful algal species, Microcystis aeruginosa from aqueous phases. Industrial waste biomass, Corynebacterium glutamicum biomass was valorized as biosorbent (PEI-modified alginate/biomass composite fiber; PEI-AlgBF) for M. aeruginosa through immobilization with alginate matrix and cationic polymer (polyethylenimine; PEI) coating. The functional groups characteristic of PEI-Alg was determined using FT-IR analysis. By adsorption process used PEI-AlgBF, 52 and 67% of M. aeruginosa could be removed under the initial density of M. aeruginosa 200×104 cells mL-1 and 50×104 cells mL-1, respectively. As the increasing surface area of PEI-AlgBF, the removal efficiency was increased. In addition, we could find that adsorptive removal of M. aeruginosa has occurred without any M. aeruginosa cell lysis and destruction.

Identification of Cold Stress-related Proteins in Rice Leaf Tissue (벼의 잎 조직에서 발현되는 저온 스트레스 관련 단백질의 분리 동정)

  • Lee Dong-Gi;Lee Sang-Hoon;Lee Byung-Hyun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.25 no.4
    • /
    • pp.287-296
    • /
    • 2005
  • To investigation protein expression pattern in rice leaves exposed to cold stress, the soluble proteins extracted from leaf tissue were fractionated with $15\%$ PEG and separated by two-dimensional polyacrylamide gel electrophoresis (2-DE). Differentially expressed proteins were identified by peptide mass fingerprinting using matrix assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). Eight proteins up-regulated and 10 down-regulated were found in $15\%$ PEG supernatant fraction. In addition, 13 proteins up-regulated and 14 down-regulated were found in $15\%$ PEG pellet fraction. It was identified the differentially expressed proteins in $15\%$ PEG supernatant fraction as pimerase/dehydratase fructokinase, ribose-5-phosphate isomerase (Rpi), chaperonin 21 precursor, probable photosystem II oxygen-envolving complex (PS II OEC) protein 2 precursor and thioredoxin h-type (Trx-h) and those in $15\%$ PEG pellet fraction as OSINBb0059K02.15, hypothetical protein, putative mitogen-activated protein kinase kinase (MAPKK), beta 7 subunit of 205 proteasome, ribulose-1, 5-bisphosphate carboxylase/oxygenase (Rubisco) small subunit. These proteins are involved in metabolism, energy, protein synthesis, disease/defense and signal transduction-related proteins.

Anti-wrinkle Activity of Low Molecular Weight Peptides Derived from the Collagen Isolated from Asterias amurensis (불가사리(Asterias amurensis) 콜라겐 유래 저분자 펩타이드의 피부주름 억제활성)

  • Kwon, Min-Chul;Kim, Cheol-Hee;Kim, Hyo-Sung;Syed, Abdul Qadir;Hwang, Bo-Yong;Lee, Hyeon-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.625-629
    • /
    • 2007
  • This study was carried out to investigate the anti-wrinkle effects of peptides derived from collagens isolated from Asterias amurensis, which was collected in the East Sea. The molecular weights of the peptides were between 10-50 kDa, as determined through sephadek G-75 gel. The cytotoxicities against CCD-986sk cells and HEL-299 cells were measured using the MTT assay. The cytotoxicity of all the fractions(F1: Fraction No. 4-13, 116 kDa; F2: Fraction No. 25-30, 100 kDa; F3: Fraction No. 45-55, 58 kDa; F4: Fraction No. 59-63, 43 kDa; F5: Fraction No. 79-90, 24 kDa) was less than 25%, by the addition of 1.0 mg/mL. These peptides did not show any adverse effects on human skin cells. In the presence of F1 at 1.0 mg/mL, matrix metalloproteinase-1 (MMP-1) expression of UVA-induced human normal fibroblasts was reduced to 34.8%. Overall, the results seem to suggest that peptides of approximately 20 kDa have superior anti-wrinkle effects.

A Study on Chloride Binding Capacity of Various Blended Concretes at Early Age (초기재령에서 각종 혼합콘크리트의 염소이온 고정화능력에 관한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.133-142
    • /
    • 2008
  • This paper studies the early-aged chloride binding capacity of various blended concretes including OPC(ordinary Portland cement), PFA(pulversied fly ash), GGBFS(ground granulated blast furnace slag) and SF(silica fume) cement paste. Cement pastes with 0.4 of a free water/binder ratio were cast with chloride admixed in mixing water, which ranged from 0.1 to 3.0% by weight of cement and different replacement ratios for the PFA, GGBFS and SF were used. The content of chloride in each paste was measured using water extraction method after 7 days curing. It was found that the chloride binding capacity strongly depends on binder type, replacement ratio and total chloride content. An increase in total chloride results in a decrease in the chloride binding, because of the restriction of the binding capacity of cement matrix. For the pastes containing maximum level of PFA(30%) and GGBFS(60%) replacement in this study, the chloride binding capacity was lower than those of OPC paste, and an increase in SF resulted in decreased chloride binding, which are ascribed to a latent hydration of pozzolanic materials and a fall in the pH of the pore solution, respectively. The chloride binding capacity at 7 days shows that the order of the resistance to chloride-induced corrosion is 30%PFA > 10%SF > 60%GGBFS > OPC, when chlorides are internally intruded in concrete. In addition, it is found that the binding behaviour of all binders are well described by both the Langmuir and Freundlich isotherms.

Binding of the Hexavalent Chromium Ions in the Process of Cement Hydration (시멘트 수화에 따른 6가 크롬의 고정화 특성)

  • Jung, Min-Sun;Hwang, Jun-Pil;Hong, Sung-In;Ann, Ki-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.88-94
    • /
    • 2013
  • The hexavalent chromium (Cr(VI)) is well known as a hazardous ion, presumably inducing dermatic diseases and if serious cancer. The present study concerns the binding capacity of Cr(VI) ions in the cement powder and matrix for a quantitative technique of Cr(VI) ions in cement to influence human health. Both the water-soluble and acid-soluble Cr(VI) ions present in 3 types of ordinary Portland cement (OPC), pulverised fuel ash (PFA), ground granulated blast furnace slag (GGBS), and silica fume (SF) were measured using the spectrophotometer. As a result, it was found that the concentration of water-soluble Cr(VI) ion in cement ranged from 10.5 to 18.9mg/kg-cement, and in the additional materials a very low value of Cr(VI) ion was measured. Acid-soluble Cr(VI) ion was even higher than water-soluble Cr(VI) ion, ranging from 172.4 to 318.2mg/kg-cement. Nevertheless, the concentration of acid-soluble Cr(VI) ion is not proportional to addition of acid. It depends rather the variable pH of solvent involving cement paste. As enough cement hydration occurs, the binding capacity of Cr(VI) ion increases, inhibiting this ions from leaching out in the presence of hydration products such as ettringite or tri-calcium aluminate which bind Cr(VI) ion by ion-exchange.

Determination of trace impurities of HFC-134a by gas chromatograph with atomic emission detector (GC/AED) (GC/AED를 이용한 HFC-134a의 미량 불순물 분석)

  • Kim, Myeongja;Lim, Jeongsik;Lee, Jinbok;Lee, Jeongsoon
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.240-251
    • /
    • 2017
  • 1,1,1,2-Tetrafluoroethane (HFC-134a), which is used as refrigerant in air conditioners, has been recently regulated as a greenhouse gas and is recommended for reuse by refining. It is very important to quantitatively analyze trace impurities present in the refrigerant to evaluate the criteria for reuse. In this study, trace impurities including C, H, Cl, and F, which are difficult to quantify because there are no reference materials, were quantitatively analyzed by a gas chromatograph-atomic emission detector (GC/AED); for this analysis, this was preceded by a qualitative analysis with a GC-mass selective detector (GC/MSD). In addition, the AED response was investigated using a hydrocarbon mixed reference material, which was proportional to the number of atoms in the component. Fifteen refrigerant components were detected as trace impurities in HFC-134a by qualitative analysis of trace impurities including C, H, Cl, and F in the samples. Based on the results of the qualitative analysis, quantitative analysis of trace impurities using AED showed that the highest mole fractions were for the $CHClF_2$ component ($45438.38{\mu}mol/mol$) in one sample and for the $C_2H_2ClF_3$ component ($1311.47{\mu}mol/mol$) in another sample. From this study, it has been shown that it is possible for this analytical method to be applied to the qualitative and quantitative analysis of trace compounds in refrigerants, which are difficult to quantify because of the absence of reference materials.

Implementation on the Urine Analysis System using Color Correction and Chromaticity Coordinates Transform Methods (색 보정 및 색 좌표 변환 기법을 이용한 요분석 시스템의 구현)

  • 김기련;예수영;손정만;김철한;정도운;이승진;장용훈;전계록
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • A transformation methode of the chromaticity coordinates was proposed to calibrate the measured data obtained by a urine analysis system which implemented in our previous study. Generally. the reacted color of a reagent strip by urine analysis system often exhibit the color distortions due to nonlinear characteristics of the various devices that is the optic module mechanism. hardware, and surround circumstance. A color correction method for minimizing the color distortion play a few role in maintaining high accuracy and reproduction of the urine analysis system. In this work, we used the compensation method such as the shading correction, the characteristic curve extraction of RGB color by means of third order spline interpolation, and linear transformation using a reference color. In addition, 1931 CIE XYZ color space was used to compensate the color of the measured data by a standard reference system as colorimeter. A compensation matrix was obtained so that the output values of the urine analysis system is nearly equal to that of a standard reference system for identical color sample. Color correction obtained by a urine analysis system which implemented in our previous study exhibited a good color accuracy when it was compared with the reference data. Observed result from an experiments on ten items or a urinalysis strip that color difference or between two urine analysis system was 1.28.