• Title/Summary/Keyword: Materials testing

Search Result 2,644, Processing Time 0.035 seconds

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.

Color stability of three dimensional-printed denture teeth exposed to various colorants (다양한 색소에 대한 3D 프린팅 인공치의 색 안정성)

  • Koh, Eun-Sol;Cha, Hyun-Suk;Kim, Tae-Hyung;Ahn, Jin-Soo;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • Purpose: This study evaluated color stability of Dentca 3D-printed denture teeth, in comparison to color stabilities of four conventional types of denture teeth, upon being immersed in various colorants. Materials and methods: Four types of conventional prefabricated denture teeth (Surpass, GC, Artic 6, Heraeus Kulzer, Premium 6, Heraeus Kulzer, Preference, Candulor), 3D-printed denture teeth (Dentca); and Z250 (Filtek Z250, 3M ESPE) were prepared for testing. The samples were immersed in erythrosine 3%, coffee, cola, and distilled water (DW) at 37℃. Color change (ΔE) was measured by spectrophotometer before immersion and at 7, 14, and 21 days after immersion. One-way analysis of variance was performed along with Tukey's honestly significant difference multiple comparisons test (P<.05). Results: No great difference was observed between the color change of Dentca denture teeth and that of conventional denture teeth in most cases (P>.05). The color change of Dentca denture teeth immersed in erythrosine 3% was greater than that of Surpass (ΔE = 0.67 ± 0.25) after 1 week; Artic 6 (ΔE = 1.44 ± 0.38) and Premium 6 (ΔE = 1.69 ± 0.35) after 2 weeks; and Surpass (ΔE = 1.79 ± 0.49), Artic 6 (ΔE = 2.07 ± 0.21), Premium 6 (ΔE = 2.03 ± 0.75), and Preference (ΔE = 2.01 ± 0.75) after 3 weeks (P<.05). Conclusion: A color change was observed in Dentca denture teeth when immersed in some colorants; however, the maximum value of ΔE for Dentca denture teeth was within the clinically acceptable range.

Integrated Test for Screening in Down Syndrome as a Predictor of Adverse Pregnancy Outcomes (임신합병증 예측에 있어 다운증후군 통합 선별검사 지표의 의의)

  • Park, Sang-Won;Kang, Jin-Hee;Lee, Kyong-Jin;Jun, Hye-Sun;Kang, Myoung-Seo;Huh, Ji-Young;Cha, Dong-Hyun
    • Journal of Genetic Medicine
    • /
    • v.6 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • Purpose: To assess the value of first-trimester pregnancy-associated plasma protein-A (PAPP-A), nuchal translucency (NT) and second-trimester alpha-fetoprotein (AFP), human chorionic gonadotropin (hCG), unconjugated estriol (uE3), and inhibin-A in predicting pregnancy complications other than fetal aneuploidy. Materials and Methods: A retrospective study in 3,121 singleton pregnancies with integrated testing was performed at Kangnam CHA hospital between January 2005 and December 2006. Baseline characteristics, pregnancy outcomes, and serum marker levels were obtained by review of the medical records. We analyzed the data to identify associations between the integrated screening markers and adverse pregnancy outcomes. Statistical analyses were performed with the SPSS program. Results: In preterm labor and preeclampsia, high AFP, hCG, and inhibin-A levels and low PAPP-A and NT levels were found to be significantly correlated (P<0.05). Elevated second-trimester inhibin-A levels were associated with preeclampsia (odds ratio 2.843), low birth weight (odds ratio 1.446), and preterm labor (odds ratio 1.287), and while decreased first-trimester PAPP-A levels were associated with preeclampsia (odds ratio 0.51) and preterm labor (odds ratio 0.75). Conclusion: First- and second-trimester maternal serum markers screening can be used for predicting high-risk pregnancies.

  • PDF

Physicochemical Properties of Fish-meat Gels Prepared from Farmed-fish (해수어를 활용한 연제품의 제조 및 물리화학적 특성)

  • Kim, Hyung Kwang;Kim, Se Jong;Karadeniz, Fatih;Kwon, Myeong Sook;Bae, Min-Joo;Gao, Ya;Lee, Seul-Gi;Jang, Byeong Guen;Jung, Jun Mo;Kim, Seo yeon;Kong, Chang-Suk
    • Journal of Life Science
    • /
    • v.25 no.11
    • /
    • pp.1280-1289
    • /
    • 2015
  • Fish-meat gel is being produced mostly relying on surimi and raw materials imported from Southeast Asia and North America and present in small amount in local markets. In this study, common farmed local fishes were examined as stable and reliable sources of surimi for fish-meat gel production. For testing, five main farmed-fish of Korea, namely; Bastard halibut (Paralichthys olivaceus), Red sea bream (Pagrus major), Korean rockfish (Sebastes schlegeli), Common mulle (Mugil cephalus), and Finespotted flounder (Pleuronichthys cornutus) were used following a traditional washing process. The quality of the surimi was determined by the values of water content, whiteness index, gel strength and impurity. Accordingly, fish-meat gel and surimi quality experiments were carried out by measuring compressive and texture properties, expressible moisture content, Hunter color scale values and SDS-page protein patterns. Also gel characteristics were compared with that of FA and RA grade surimi (Alaska Pollock). Fish-meat gels were prepared by salt mincing the farmed-fish surimi with NaCl (2% w/w) and moisture adjustment to 84% by ice water adding. Prepared fish-meat paste was filled into 20-25 cm long polyvinylidene chloride casings and heated at 90℃ for 20 min. The whiteness values of fish-meat gels produced from surimi were increased by using farmed-fish and became comparable to that of FA Alaska Pollock gel. Among all tested farmed-fish, P. olivaceus and P. major exhibited better properties than RA Alaska Pollock and similar properties to FA Alaska Pollock. Therefore, current data suggests that fish farming can be an efficient and sustainable fish-meat source for fish-meat gel production in Korea.

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

Arthroscopic Decompression of Spinoglenoid Ganglion Cyst (견갑골 극관절와 결절종의 관절경하 감압술)

  • Hwang, Tae Hyok;Wang, Tae Hyun;Cho, Hyung Lae;Kim, Keun Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.92-98
    • /
    • 2011
  • Purpose: We describe a all-arthroscopic technique for decompression of spinoglenoid ganglion cyst and present our clinical results for this procedure. Materials and Methods: From March 2006 to June 2009, eight patients (7 males, 1 female; mean age 40.6 years; range: 21~61) were included who underwent arthroscopic decompression of spinoglenoid ganglion cyst. The most common symptoms were vague shoulder pain and external rotation weakness, which lasted 6.4 months (range: 3~8) on average. Five of eight patients were noted abnormalities on electromyographic (EMG) examination to have suprascapular nerve neuropathy and magnetic resonance imaging (MRI) showed spinoglenoid ganglion cysts in all eight patients and the cyst size was 2.6 cm (range: 1.8~3.6). Labral pathology was identified intraoperatively in all patients and the cysts were decompressed by the posterosuperior capsulotomy under arthroscopic control and labral repair with suture anchors was performed in six patients. Results: The average clinical outcome scores including Constant and Murley, Simple shoulder test (SST) all improved significantly at the time of the final follow-up and there were no complications resulting from the procedures. All patients including the patients with abnormal EMG study recovered strength on isokinetic strength testing. Follow-up MRI scans were performed on all patients at a mean of 5.2 months postoperatively (range: 3~12) revealed complete resolution of the cysts and no evidence of recurrences were seen at an average of 18 months (range: 12~26) of follow-up. Conclusion: Arthroscopic decompression of spinoglenoid ganglion cyst effectively restores patient function and all patients in this study showed improvement in their postoperative MRI findings. Arthroscopic decompression is also useful in the appropriate treatment for labral pathology and may contribute to decreased risk of cyst recurrence.

  • PDF

A Study of both Femurs Bone Densitometry's Difference for Exercise (운동유무에 따른 양측 대퇴골 골밀도 차이에 관한 연구)

  • Jang, Eun-Ju;Kim, Eun-Hye;Kim, Ho-Sung;Shin, Sang-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.73-76
    • /
    • 2009
  • Purpose: Bone mineral densitometry test region advised by ISCD (International Society for Clinical Densitometry) is both site in case of femur, whereas our medical center measures left femur except for few extraordinary cases. It is said that right-handers had higher mean femur BMD in the left side than in the right side, but the factor influence the femur BMD is unknown. Thus, we investigate whether testing left femur only is a adequate clinical diagnosis. Materials and Methods: Subjects were 209 right-handers and 20 left-handers patient in Asan Medical Center from July to August, 30 to 70 years of age ($51{\pm}6.7$). Subjects fill out the questionnaire on hand preference and taking regular exercise. Total BMDs of bilateral femur were measured with GE Lunar Prodigy advance densitometer, and the statistical soft ware SPSS 12.0 for windows was used for statistical analysis. Results: In the total sample of the exercise group (n=127), the difference of both femur mean BMDs are $0.001{\pm}0.127\;g/cm^2$ and the non-exercise group's (n=102) both femur difference is $0.002{\pm}0.126\;g/cm^2$, there is no significant difference. And in exercise group, classified according to hand preference, each t-value is shown at right handers (n=114) are 0.65, left handers (n=13) are -0.39. Also, In non-exercise group, right handers (n=95) are -0.78, left handers (n=7) are -0.64. In the 95% confidence limit, there was no statistically significant difference (p>0.05). Conclusions: In recently researchs, there have been differences between both femurs according to hand preference. However, Our study have no significant difference both femurs BMDs. Therefore we suggest that BMD measurement of femur has no problem only one side, except for particular case like femur operation.

  • PDF

Long-term Changes in Soil Chemical Properties in Organic Arable Farming Systems in Korea (작물의 지속적인 유기 재배가 토양의 이화학적 특성변화에 미치는 영향)

  • Lee, Yun-Jeong;Choe, Du-Hoi;Kim, Seung-Hwan;Lee, Sang-Min;Lee, Yong-Hwan;Lee, Byung-Mo;Kim, Tae-Wan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.4
    • /
    • pp.228-234
    • /
    • 2004
  • In organic farming, nutrients for the crop production are mostly supplied by compost containing various organic materials. The long-term organic cultivation would result in continuous changes of soil chemical properties and fertility. The aim of this study was to investigate the contribution of long-term organic cultivation to the soil fertility in Korea focusing on the chemical properties of soil. Soil samples were collected from organic farms that had been cultivated for 8-10 years after certification of organic product through the conversion periods of 2-3 years. Thereby each organic farm had acquired optimal cultivating techniques and soil condition. We separated organic farms into three groups by cultivating crops, i.e. leaf vegetables, fruit vegetables and fruit trees. In each group, five representative farms were chosen in order to investigate the relationships between application rate of compost and nutrient contents in soil. The application rate of compost was approximately $10-15Mg\;10a^{-1}$ for the first 2-3 years at the beginning of organic farming and then reduced to a rate of $3-4Mg\;10a^{-1}$ after stabilization of organic matter content in soil with $30-50g\;10a^{-1}$. However, the continuous organic farming for 8-10 years resulted in accumulation of nutrients, especially of P, in soil probably due to the excessive amounts of compost applied. In conclusion, we suggest that the application rate and organic sources of compost should be decided on the basis of P content in soil by soil testing and thereafter the lack of soil N content for crop cultivation should be compensated by crop rotation with such as legumes. This might be an approach to the original meaning of organic farming as an environmental friendly agriculture.

The effect of Silano-pen on the shear bond strength of resin to feldspathic porcelain and zirconia (실라노 펜의 적용이 장석계 도재 및 지르코니아와 레진의 전단결합강도에 미치는 영향)

  • Shin, Myoung-Sik;Lee, Jeong-Yol;Kim, Min-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the effect of applying Silano-pen to feldspathic porcelain and zirconia on shear bond strength with composite resin. Materials and methods: Feldspathic porcelain and zirconia specimens were produced into 30 per each 2 mm thick and 12 mm in diameter and their surface was made smooth and even and then embedded in acrylic resin. The specimens were divided into each Group F (Feldspathic porcelain) and Group Z (Zirconia), (1) Hydrofluoric acid etching and silane (F1 & Z1), (2) Silano-pen and silane (F2 & Z2), (3) Hydrofluoric acid etching and Silano-pen, silane (F3 & Z3). After surface conditioning, substrate surfaces of the specimen were examined by SEM. Composite resin cylinders (2 mm high, 3 mm in diameter)were bonded to specimen and shear bond strength between ceramic and composite resin was measured by using universal testing machine. The measured values were statistically analyzed by using two way ANOVA and Tukey's multiple comparison test (${\alpha}=.05$). Results: In the scanning electron micrograph of the treated ceramic surface, Group F2 and F3 appeared the high roughness and Group Z3 appeared the highest density of silica particle. In Feldspathic porcelain, the result of measuring shear bond strength showed that Group F3 was measured to be highest and Group F1 was measured to be lowest but there was no statistical significance among Groups. In zirconia, Group Z3 was measured to be highest and Group Z1 was measured to be lowest and there was statistical significance among Groups (P<.05). Conclusion: In zirconia, applying hydrofluoric acid etching and then Silano-pen and silane is effective for composite resin adhesion.

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.