• Title/Summary/Keyword: Material testing

Search Result 2,012, Processing Time 0.031 seconds

Microstructure and Wear Properties of Oxide Dispersion Strengthened Steel Powder Added Steel-Based Composite Material for Automotive Part (산화물 분산 강화 강 분말이 첨가된 자동차 부품용 철계 복합 소재의 미세조직 및 마모 특성)

  • Kim, Young-Kyun;Park, Jong-Kwan;Lee, Kee-Ahn
    • Journal of Powder Materials
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2018
  • In order to expand the application of oxide dispersion-strengthened (ODS) steel, a composite material is manufactured by adding mechanically alloyed ODS steel powder to conventional steel and investigated in terms of microstructure and wear properties. For comparison, a commercial automobile part material is also tested. Initial microstructural observations confirm that the composite material with added ODS steel contains i) a pearlitic Fe matrix area and ii) an area with Cr-based carbides and ODS steel particles in the form of a $Fe-Fe_3C$ structure. In the commercial material, various hard Co-, Fe-Mo-, and Cr-based particles are present in a pearlitic Fe matrix. Wear testing using the VSR engine simulation wear test confirms that the seatface widths of the composite material with added ODS steel and the commercial material are increased by 24% and 47%, respectively, with wear depths of 0.05 mm and 0.1 mm, respectively. The ODS steel-added composite material shows better wear resistance. Post-wear-testing surface and cross-sectional observations show that particles in the commercial material easily fall off, while the ODS steel-added material has an even, smooth wear surface.

Experimental Study on Reinforcing Fiber for Civil Engineering used for Waterproofing Protection and Root Resistance Performance (방수보호재 및 방근재로서의 활용을 위한 토목용 보강섬유의 실험적 연구)

  • Kim, Bum Soo;Lee, Jung Hun;Song, Je Young;Song, Young-Chan;Kim, Yong-Ro;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.67-68
    • /
    • 2017
  • This paper discusses the application of civil structure use reinforcing fiber mixed with concrete to be used as protection layer of waterproofing material and root resistant layer installed in below-grade parking lot upper slab of residential building. A performance evaluation under the prescribed method outlined in KS F 4938 was used for this new material. The testing results showed that the fiber reinforcement can be used to strengthen the protection for the waterproofing material. Also, plants that were planted in June 2016 have not yet penetrated the specimens used for root resistance testing. The domestic root resistance performance testing usually covers the period of 2 years, thus further observation to make any conclusion about the root resistance property is required.

  • PDF

Evaluation of Micro-Tensile Properties for Nano-coating Material TiN (나노 코팅재 TiN 의 마이크로 인장 특성 평가)

  • Huh, Yong-Hak;Kim, Dong-Iel;Hahn, Jun-Hee;Kim, Gwang-Seok;Yeon, Soon-Chang;Kim, Yong-Hyub
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.240-245
    • /
    • 2004
  • Tensile properties of hard coating material, TiN, were evaluated using micro-tensile testing system. TiN has been known as a hard coating material commonly used today. Micro-tensile testing system consisted of a micro tensile loading system and a micro-ESPI(Electronic Speckle Pattern Interferometry) system. Micro-tensile loading system had a maximum load capacity of 500mN and a resolution of 4.5 nm in stroke. TiN thin film $1{\mu}m$ thick was deposited on the Si wafer pre-deposited of $Si_3N_4$ film substrate by the closed field unbalanced magnetron sputtering (CFUBMS) process. Three kinds of micro-tensile specimen with the respective width of $50{\mu}m$, $100{\mu}m$ and $500{\mu}m$ were fabricated by MEMS process. The mechanical properties including tensile strength and elastic modulus were determined using the micro-tensile testing system and compared by those obtained by nano-indentation

  • PDF

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Ceramic Panel and Painting Materials for Humidity Control (습도조절용 세라믹패널 및 도료의 흡·방습성능 평가)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.43-52
    • /
    • 2018
  • This study is conducted to evaluate the performance of ceramic panels and painting materials for humidity control which are developed in non-plastic room temperature hardening structure as part of a project to improve a residential environment for the low-income class, rather than the performance of high-priced humidity control materials that are produced with the existing plasticity processing. The testing methods included the measurements of absorption & desoprtion of humidity per material; Mock-up Testing; an evaluation method of comparing the absorption & desoprtion performances of Ecocarat, ceramic panels and painting materials through Living Lab. According to the measurements of absorption & desoprtion per material, ceramic panels, E panel, and ceramic painting material showed 73.3g/m2, 96.6g/m2, and 111.1g/m2, respectively. That is, the performance of humidity control of each material was found to be good in the order of: Ceramic Paint > E panel > Ceramic Panel. According to performance evaluation testing with Mock-up test and Living Lab, Ceramic Paint, Ecocarat, and Ceramic Panels showed better absorption & desoprtion performances in the order.

PVC and POM gripping mechanisms for tension testing of FRP bars

  • Basaran, Bogachan;Yaka, Harun;Kalkan, Ilker
    • Structural Engineering and Mechanics
    • /
    • v.77 no.1
    • /
    • pp.75-87
    • /
    • 2021
  • The present study pertains to the introduction of two new types of grip adaptor for universal testing machines, namely Polyvinyl Chloride (PVC) and Polyoxymethylene (POM) grip adaptors, and their application to tension testing of FRP bars with different fiber and surface finish types. The tabs are connected to the FRP bar sample with the help of mechanical anchors, i.e. bolts. These new adaptors offer vital superiorities over the existing end tab designs (anchors with filling material or mechanical anchorage), including the reduction in the time and labor for production, reusability and the mild nature, i.e. low hardness of the tab material, which retards and even prevents peeling and crushing in the gripping regions of an FRP sample. The methods were successfully applied to FRP bars with different types of fiber (CFRP, GFRP and BFRP) and different types of surface texture (ribbed, wrapped, sand-coated and wound). The test results indicated that the both types of end caps prevented slip of the bar, crushing and peeling in the gripping zone. The mechanical properties from the material tests with the new caps were in perfect agreement with the ones from the material tests with steel tubular caps.

Theoretical Modeling of the Resonant Column Testing with the Viscosity of a Specimen Considered (점성을 고려한 공진주 실험의 이론적 모델링)

  • 조성호;황선근;권병성;강태호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.145-153
    • /
    • 2003
  • The resonant column testing determines the shear modulus and material damping factor dependent on the shear strain magnitude, based on the wave-propagation theory. The determination of the dynamic soil properties requires the theoretical formulation of the dynamic behavior of the resonant column testing system. One of the theoretical formulations is the use of the wave equation for the soil specimen in the resonant column testing device. Wood, Richart and Hall derived the wave equation by assuming the linear elastic soil, and didn't take the material damping into consideration. Hardin incorporated the viscoelastic damping of soil in the wave equation, but he had to assume the material damping factor for the determination of the shear modulus. For the better theoretical formulation of the resonant column testing, this study derived a new wave equation to include the viscosity of soil, and proposed an approach for the solution. Also, in this study, the equation of motion for the testing system, which is another approach of the theoretical formulation of the resonant column testing, was also derived. The equation of motion leads to the better understanding of the resonant column testing, which includes the dynamic magnification factor and the phase angle of the response. For the verification of the proposed equation of motion for the resonant column testing, the finite element analysis was performed for the resonant column testing. The comparison of the dynamic magnification factors and the phase angles far the system response were performed.

Resistance to Root Penetration of Root Barrier for Green Roof System (옥상녹화용 방근층 구성재료의 방근성능에 관한 실험적 연구)

  • Kim, Hyun-Soo;Jang, Dae-Hee;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.123-129
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plant: and soils suitable for weather and natural features of Korea. For testing Plants, Plioblastus pygmaed Mitford A and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of roe barrier materials have penetrated roots. Even though two types of them have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe. USA or Japan.

Examination Conditions of Root Barrier for Green Roof System and Result of Intermediate Observation of Three Months against Representative Root Barrier (옥상녹화용 방근층의 방근성 시험조건 설정 및 주요 방근소재에 대한 3개월간의 중간관찰 결과)

  • Shin, Yun-Ho;Jang, Dae-Hee;Kim, Hyun-Soo;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.245-249
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plants and soils suitable for weather and natural features of Korea. For testing plants, Plioblastus pygmaed Mitford A. and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio(volume). Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of root barrier materials have penetrated roots. Even though two types of them(EDPM Sheet, Polyethylene Sheet) have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe or Japan.

  • PDF

Standardization of Fracture Toughness Testing of Ceramics in the United States

  • Quinn, G.D.;Jenkins, M.J.;Salem, J.;Bar-On, I.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.311-322
    • /
    • 1998
  • American Society for Testing and Materials (ASTM) standard test method PS 070-97 has been created for measuring fracture toughness of advanced ceramics. PS 070-97 includes three test methods which use beams in bending: chevron notch (CNB), single-edged precracked beam (SEPB), and surface crack in flexure (SCF). Supporting data has been collected through several Versailles Advanced Materials and Standards round robins. This paper discusses the evolution of the standard including the rationale for the choice of the three methods and the specifications in the standard. Progress on Standard Reference material 2100 which will have certified values of fracture toughness is presented.

  • PDF

Measurement of Electromagnetic Properties of Mortar for Nondestructive Testing (비파괴 실험을 위한 모르타르의 전자기적 특성 측정)

  • 정성훈;임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.779-784
    • /
    • 1998
  • The velocity and amplitude of microwaves are affected by the electromagnetic properties of a material through which the wave propagates. And the electromagnetic properties of a dielectric material such as concrete is represented by its permittivity. For the development of an accurate and reliable nondestructive testing (NDT) technique for concrete structures using microwave, it is necessary to have knowledge about the permittivity of concrete. In this paper, mortar specimens are used to serve as a basis for further measurement of concrete. The effect of water on the permittivity was studied using specimens with different water content. To assure the reliability of the measurement results, a statistical method was introduced.

  • PDF