• Title/Summary/Keyword: Material symmetry

Search Result 161, Processing Time 0.027 seconds

AN INDIFFERENT CONSTITUTIVE LAW IN FINITE ELASTICITY

  • Akinola, Ade
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.3
    • /
    • pp.919-934
    • /
    • 2001
  • The concepts of material frame-indifference and material symmetry group with respect to isotropic scalar functions, as represented by energy functions, are discussed. An energy function for a structured heterogeneous (transversal isotropic) medium in large elastic deformations, which is known to satisfy the Ponyting’s effect [1], is highlighted. It is shown that the constitutive relation due to this energt function is material frame-indifferent.

Elastic Wave Propagation in Monoclinic System Due to Harmonic Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2E
    • /
    • pp.47-52
    • /
    • 1998
  • An analysis of dynamic responses is carried out on monoclinic anisotropic system due to a buried harmonic line source. The load is in the form of a normal stress acting along an arbitrary axis on the plane of symmetry within the orthotropic materials: In case that the line load is acting along the symmetry axis normal to the plane of symmetry, plane wave equation is coupled with verital shear wave and longitudinal wave. However, if the line load is acting along an arbitrary axis normal to the plane of symmetry, plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in a reference coordinate system, where the line load is coincident with a symmetry axis of the orthotropic material. Then the equation of motion is transformed into one with respect to general coordinate system with azimuthal angle by using transformation tensor. Plane wave solutions of monoclinic systems are derived for infinite media. Finally complete solutions for the plane harmonic wave are obtained by calculating the inverse of the integral transforms, in which bulk wave poles are avoided by deforming the contour of the integration to the complex plane. Numerical results for examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF

A Visual Inspection System for Printing Detects using Perimetric Mask and Generalized Symmetry Transform Algorithm (주변 마스크와 일반화 대칭변환 알고리듬을 이용한 인쇄물 검사 시스템)

  • 기명석;이칠우
    • Proceedings of the IEEK Conference
    • /
    • 2000.11d
    • /
    • pp.223-226
    • /
    • 2000
  • In this paper, we report detects system algorithm, adapted a perimetric mask and a generalized symmetry system, to detect a transformable material and find out a minute error cannot be noticed by a naked eye. In this thesis, supposed a stable detecting system applied a general image processing theory and perimetric mash algorithm to detect badness. And finally, detected some vague errors with the application of symmetry transform algorithm that accumulate a symmetry of minute error and put stress on it.

  • PDF

Anisotropic Temperature Factors at Special Positions (특수위치(特殊位置)에서의 비등방성온도인자(比等方性溫度因子))

  • Kim, Young-Sang;Ko, Jae-Jung;Kang, Sang-Ook;Son, Ho-Jin;Son, Ki-Chul;Han, Won-Sik;Suh, Il-Hwan;Kim, Youn-Joong;Kim, Jin-Gyu
    • Korean Journal of Crystallography
    • /
    • v.16 no.2
    • /
    • pp.81-88
    • /
    • 2005
  • The atoms located at a general position in a crystal do thermally ellipsoidal vibration satisfying 1-fold rotation symmetry. Likewise the thermal vibration of atom at special position must comply with the symmetry of the special position. This paper shows how to calculate the anisotropic temperature factors of the atoms located at special positions.

Elastic Wave Propagation in Monoclinic System Due to Transient Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2E
    • /
    • pp.53-58
    • /
    • 1998
  • In this paper, we study the response of several anisotropic systems to buried transient line loads. The problem is mathematically formulated based on the equations of motion in the constitutive relations. The load is in form of a normal stress acting with arbitrary axis on the plane of monoclinic symmetry. Plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in reference coordinate system, where the line load is coincident with symmetry axis of the orthotrioic material. Then the equation of motion is transformed with respect to general coordiante system with azimuthal angle by using transformation tensor. The load is first described as a body force in the equations of the motion for the infinite media and then it is mathematically characterized. Subsequently the results for semi-infinite spaces is also obtained by using superposition of the infinite medium solution together with a scattered solution from the free surface. Consequently explicit solutions for the displacements are obtained by using Cargniard-DeHoop contour. Numerical results which are drawn from concrete examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF

Fabrication of Photonic Quasicrystals using Multiple-exposure Holographic Method (다중-노출 홀로그라피 방법을 이용한 광자준결정 제작)

  • Yun, Sang-Don;Yeo, Jong-Bin;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.829-834
    • /
    • 2008
  • Two-dimensional photonic quasicrystal (PQCs) template patterns have been fabricated on a 1.1 ${\mu}m$-thick DMI-150 photoresist using a multiple-exposure holographic method. A 442-nm HeCd laser was utilized as a light source and the holographic exposure was carried out at a fixed angle of ${\theta}$ = 6$^{\circ}$. After the first holographic exposure, the sample was rotated to a proper angle and the second exposure was performed to the same manner. This exposure process was repeated n/2 times to obtain n-fold symmetric PQC patterns and then the sample was developed. The diffraction patterns of the fabricated PQC template were observed using a 632.8-nm HeNe laser. The fabricated PQCs exhibited 8, 10 and 12-fold rotational symmetry, which was in a good agreement with the interference simulation results. In addition, the diffraction patterns with n-rotation symmetry were observed for the corresponding n-fold PQCs. We believe that the multiple-exposure holography is a good method to fabricate the mesoscale PQCs with a high rotational symmetry.

CAD for Detection of Brain Tumor Using the Symmetry Contribution From MR Image Applying Unsharp Mask Filter

  • Kim, Dong-Hyun;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.4
    • /
    • pp.230-234
    • /
    • 2014
  • Automatic detection of disease helps medical institutions that are introducing digital images to read images rapidly and accurately, and is thus applicable to lesion diagnosis and treatment. The aim of this study was to apply a symmetry contribution algorithm to unsharp mask filter-applied MR images and propose an analysis technique to automatically recognize brain tumor and edema. We extracted the skull region and drawed outline of the skull in database of images obtained at P University Hospital and detected an axis of symmetry with cerebral characteristics. A symmetry contribution algorithm was then applied to the images around the axis of symmetry to observe intensity changes in pixels and detect disease areas. When we did not use the unsharp mask filter, a brain tumor was detected in 60 of a total of 95 MR images. The disease detection rate for the brain was 63.16%. However, when we used the unsharp mask filter, the tumor was detected in 87 of a total of 95 MR images, with a disease detection rate of 91.58%. When the unsharp mask filter was used in the pre-process stage, the disease detection rate for the brain was higher than when it was not used. We confirmed that unsharp mask filter can be used to rapidly and accurately to read many MR images stored in a database.

A Comparision of the Twisting of Extrusion of Elliptical Shape with that of S shape from Round Billet by DEFORM-3DTM Software (원형빌렛으로부터 타원단면 및 S단면 가진제품의 압출가공의 DEFORM-3DTM에 의 한 비틀림 해석 비교)

  • 김진훈;김한봉;진인태
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.136-139
    • /
    • 1997
  • Applications of commercial software DEFORM-3DTM for 3-D simulation in extrusion process are developed for the analysis of twisting of extruded products. Because the elliptical shape has at least one line symmetry, the twisting is not occured during the extrusion. But, the results of extrusion simulation of the elliptical shape show that the twisted boundary of the die surface makes the material inside die surface rotate with the constant angular velocity. Otherwise, the simulation results of the S shaped product show that the twisting can be occured by the only 180$^{\circ}$rotation symmetry of S shape without no line symmetry and show that the angular velocity increases by the only 180$^{\circ}$rotation symmetry without no twisted die surface between on the die entrance section and on the die exit section. The results of the analysis show that the angular velocity of the extruded product changes with die length and friction condition.

  • PDF

Fabrication of photonic quasicrystals using multiple-exposure holographic method and bandgap properties (다중-노출 홀로그라피 방법을 이용한 광자 준결정 제작 및 밴드갭 특성)

  • Yun, Sand-Don;Yeo, Jong-Bin;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.8-8
    • /
    • 2008
  • Two-dimensional photonic quasicrystal (PQCs) template patterns have been fabricated on a $1.1{\mu}m$-thick DMI-150 photoresist using a multiple-exposure holographic method. A 442-nm HeCd laser was utilized as a light source and the holographic exposure was carried out at a fixed angle of $\theta=6^{\circ}$. After the first holographic exposure, the sample was rotated to a proper angle and the second exposure was performed to the same manner. This exposure process was repeated n/2 times to obtain n-fold symmetric PQC patterns and then the sample was developed. The fabricated PQCs exhibited 8, 10 and 12-fold rotational symmetry and the diffraction patterns using a 632.8-nm HeNe laser were observed for n-rotation symmetry corresponding n-fold PQCs. The fabricated PQC template patterns were examined using scanning electron microscopy(SEM). Transmission spectra were measured fourier transform infrared(FTIR) spectrometer.

  • PDF

Mixed Mode Crack Extension in Orthotropic Materials (직방성 복합재료에서 혼합모드 균열의 진전)

  • Kang, Seok-Jin;Cho, Hyung-Seok;Lim, Won-Kyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.10
    • /
    • pp.35-41
    • /
    • 2005
  • The problem of an orthotropic composite material with a central crack inclined with respect to the principal axes of material symmetry is studied. The material is subjected to uniform biaxial loading along its outer boundaries. The normal stress ratio theory is applied to predict initial crack extension behavior in cracked composite materials. The dependence of the crack extension angle with respect to the biaxial loading and the principal axes of material symmetry is discussed. Our analysis shows significant effects of horizontal loading, crack angle and fiber angle on the crack extension.