• Title/Summary/Keyword: Material and Contamination

Search Result 450, Processing Time 0.028 seconds

Electrical Properties of Outdoor Insulator with the Difference of Contaminated Condition (오손조건에 따른 옥외절연물의 전기적 특성)

  • 최남호;구경완;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.467-470
    • /
    • 2000
  • This paper present the result of the investigation, electric properties of outdoor insulators with the difference of contaminated condition. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. A mini-fog chamber with transparent acryl and the standard contamination solution with kaoline was used. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current and the ambient condition, such as relative humidity and temperature, a DAS system was developed with LabView. From the result, we could know the influence of contaminated condition. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

The Electric Properties of Insulators Due to Non-soluble Contaminant (불용성 오손물에 의한 절연물의 전기적 특성에 관한 연구)

  • 최남호;국연호;조성인;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.691-695
    • /
    • 2000
  • This paper present the result of the investigation, the electric properties of insulators due to non-soluble contamination. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. Though the non-soluble do not distribute on conductivity of contaminant layer, that has the hygroscopic property. For this study, we make a mini-fog chamber with transparent acryl and the kaoline was used for non-soluble contaminant. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current a DAS system was developed with LabView. With the result, we could know the influence of non-soluble content and the relationship between NSDD and ESDD.

  • PDF

Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement (세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

Analyses of Leakage Current of Transmission Insulator as a Function of Environmental Condition (환경에 따른 송전용 애자의 누설전류 분석)

  • Choi, In-Hyuk;Lee, Dong-Il;Kim, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1166-1170
    • /
    • 2004
  • The leakage currents of transmission insulator were investigated as a function of environmental conditions, such as temperature, humidity, and rainfall. The insulators were artificially contaminated with insoluble yellow soil and kaolin which helped salt to stick on the surface of insulator. The insulators contaminated with the grade of B, C, and D were installed in the KoChang Testing Center. The leakage currents were measured and compared with non-contaminated insulators. The results indicated that the most important factor affecting leakage current was humidity. After heavy rain, the artificially contaminated salt was dissolved, resulting in similar characteristics between with and without contamination

  • PDF

The Characteristics of Artificial Contamination of Distribution Polymer Insulators Used for Outdoor Insulation (옥외에서 사용되는 배전용 폴리머애자의 인공오손 특성)

  • 이병성;한재홍;김찬영;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.595-597
    • /
    • 2000
  • Poymeric insulators using in an heavy contamination area are easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we manufactured slurry mixed by some kaolin and salt as artificial contaminated solution. And then put samples in its slurry, for about one minute. And these samples are dried in natural condition for 6 days. We measured the degree of contaminant, AC leakage current for these contaminated samples.

  • PDF

Effects of Added Silicone Oils on the Surface Hydrophobicity of Silicone Rubber (실리콘 고무의 소수성에 미치는 첨가된 실리콘 오일의 영향)

  • Han Dong-Hee;Cho Han-Goo;Kang Dong-Pll;Min Kyung-Eun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.46-51
    • /
    • 2006
  • This paper reports on the effects of silicone oils, used as processing agents, on the recovery of hydrophobicity of silicone rubber. The recovery of hydrophobicity was evaluated by the measuring the contact angle, the surface electrical resistance and SEM. Here, we formed artificial contamination on the surface of samples, which scratched by sand papers and alumina powders. There was small recovery of hydrophobicity on the surface of SIR-A that silicone oil was not added. In both oil-added samples, SIR-B and SIR-C, recovery of hydrophobicity was achieved greatly. The surface of SIR-C showed that a lot of silicone oil was observed due to migration of oil, relatively in comparison with SIR-B. The tendency of recovery of hydrophobicity expressed by contact angle was in a good agreement with electrical property as determined by surface resistivity.

Ultrasound Probe Contamination Classification using ATP Meter (ATP meter를 이용한 초음파 탐촉자의 오염도 분류)

  • Ha, Myeong-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the contamination level was measured using an ATP meter using adenosine triphosphate bioluminescent material to find effective infection control to compensate for the disadvantages of the microbial culture method used for hygiene control of ultrasound probe. The convex probes were selected from six ultrasound probe in the hospital, and the samples were taken in real time before and after cleaning to check the contamination of the probe. In order to classify the pollution degree using the APT meter was classified by category. A total of 78 samples were collected from the ultrasound probe. When the pollution levels before and after cleaning were classified by category, 76.6% of the samples were classified into category 3·4 before cleaning, but they decreased to 23.3% after cleaning. 13.3% before cleaning was in category 1, but increased to 43.3% after cleaning. By classifying the pollution level, it was confirmed that the pollution level was significantly reduced by category. Until now, there was no suitable criterion for determining the contamination level by using ATP meter in medical machines where sample area is small and reused. In this study, criteria for each category were set to measure the contamination level of ATP meter suitable for small sample area such as ultrasound probe, so that contamination level could be determined in real time at the site. Therefore, it is considered that hygiene management for ultrasound probe can be more actively performed.

A Study on Contamination of Fish Sold at Wholesale Market in Seoul Area -Material Collected from Seoul Karak Fish Market- (겨울철에 시판되는 어패류에 있어서의 E. coli와 Coliform에 관한 연구 -서울시 가락동 농수산물시장을 중심으로-)

  • 노병의;빈성오;김성원
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.4
    • /
    • pp.294-299
    • /
    • 1997
  • A study was conducted to determine contamination status of fish sold at wholesale market in Seoul. A total of 79 samples (35 different kindry fish) were collected from the wholesale market. E. coli and coliform group bacteria were cultured and tested for sensitivity against antibiotics. The results are summarized as follows; 1. E. coli was isolated from 23 out of 79 samples (29.1%), and coliform groups from 53 out of 79 (67.1%). 2. Of coliform group, Citrobacter freundii was the most common and Enterobacter clacae was the next. 3.23 E. coli strains isolated from fishes were resistant to Oxacillin, Erythromycin and Lincomycin, meanwhile 23 E. coli strains were sensitive to Cefoperazone, Ceftazidime, Imipenem, and Ciprofloxacin.

  • PDF

Decontamination of Simulated Test Piece by Dry Ice Pellet Blasting (드라이아이스 펠렛 분사에 의한 모의 시편의 제염)

  • Shin Jin-Myeong;Park Jang-Jin;Yang Myung-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.2
    • /
    • pp.30-36
    • /
    • 2004
  • Dry decontamination technique is required for maintaining nuclear material handling equipment contaminated with highly radioactive material in a hot cell. In order to determine the optimum blasting conditions of dry ice pellet blasting device, the basic experiments have been conducted on the simulated test specimens of four types of metals. The removal efficiency of test piece was evaluated by the XRF analysis and the change of the surface condition before and after blasting. The removal efficiency of cesium on loose contamination was 100% under blasting pressure; 3 kg/$cm^2$, blasting distance; 10 cm, blasting time: 10 sec. In case of fixed contamination, the removal efficiency of cesium was almost 96% under blasting pressure; 4kg/$cm^2$, blasting distance; 10 cm, blasting time; 30 sec.

Investigation on DHF Application at Metal CMP Cleaning Process (Metal CMP 세정 공정에서 DHF 적용에 관한 연구)

  • 김남훈;김상용;김인표;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.569-572
    • /
    • 2003
  • In this study, we evaluated the dilute HF cleaning to reduce residual defects made by metal CMP process. The purpose of this test is to observe the existence of barrier metal damage during DHF cleaning on condition that it should not affect metal thin film reliability, so we will get rid of slurry residual particles as a main defect of the metal CMP process for the better yield. In-line defect data showed us that slurry residual particles were removed by DHF application. The HF rinse significantly reduced metal contamination levels and surface roughness. The best effect by additional oxide loss was discovered when Dilute HF condition is 10".