• Title/Summary/Keyword: Material Using Regulation

Search Result 139, Processing Time 0.032 seconds

Study of fire protection performance of newly developed cementitious fire protection material for application to architectural building (건축구조물에 적용하기위한 신개발 시멘트계 내화재료의 내화성능에 관한 연구)

  • Kim, Jang-Ho;Park, Hae-Geun;Lee, Myeong-Sub;Won, Jong-Pil;Lim, Yun-Mook;Lee, Kyong-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.633-636
    • /
    • 2006
  • High-rise and large size buildings require high strength concrete and steel structure as a necessity. However, high strength concrete and steel structure are strong material but have a weakness to high temperature. Therefore, fire protection is a matter that must be considered very importantly in design for structure of high strength concrete and steel. Fire proof board that is existing method for fire proof has relatively low performance in fire protection emphasizes the need of new fire protection material due to the using of in numerable inflammables like plastics. The objective of this study is to understand the fire-resisting performance of newly developed fire protection material for building. This paper describes the results of fire tests using ISO curve that is fire protection regulation for buildings of the newly developed cementitious fire protection coating material applied concrete tunnel lining specimens.

  • PDF

Reduction Method for Floor Impact Noise on APT Remodeling (공동주택 리모델링 현장의 바닥충격음 저감대책)

  • Park, Cheol-Yong;Hong, Goo-Pyo;Lee, Jong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.524-525
    • /
    • 2009
  • Heavy-weight impact noise(HN) is the most irritating noise in Korean apartment houses. It has been proclaimed standard floor system of 210mm thick slab with isolation material in the wall type structure. But this regulation is applied only new construction field and is not considered remodeling field. In general, the LN can be reduced by using isolation material but HN is known as relating with stiffness, strength & boundary condition of slab. Therefore it is difficulty in improving the HN on remodeling field. In this study, We conducted the reinforcement of concrete slab using C.F.S.(carbon fiber sheet), steel plate and steel beam after on-dol with isolation material on the remodeling field. As the test results, It appeared using C.F.S was no improved but using steel plate & steel beam were a little improved on HN.

  • PDF

The Effects of Coloring Admixture on the Material Properties of Color Concrete (착색재가 칼라콘크리트의 물성에 미치는 영향)

  • 이성로;김종식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.150-154
    • /
    • 2000
  • Coloring admixture is used for take color inside and outside of mortar and concrete, differently form pigment and spray paint take color limited surface. In our country, Using the coloring admixture is very slight and regulation is not yet about it. But that is expected the increase with raising the standard of living. Especially it is used to civil structure like dam and seawall for the environment harmony. Then we observe, in this experiment, the effect of coloring admixture on the material properties of color concrete and propose the suitable mix-proportion of color concrete.

  • PDF

The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form (EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발)

  • Park, Cheol-Yong;Kim, Sang-Hoon;Jang, Dong-Woon;Jang, Cheol-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

Eight Legs walker by using janssen mechanism (얀센 메커니즘을 활용한 보행체)

  • Seok, Jun young;Hong, Jun gi
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.485-488
    • /
    • 2016
  • In this paper, the mechanism that works by using eight legs is proposed. The walker has eleven bars instead of wheel, it shows a Biologically-inspired movement method. their driving appearance is very similar with creature which walks by its legs. For example, a crab and spider so on. This mechanism has simple style that can expand its size and attach more legs beside. For the competition regulation, we had to find working parts in the science box and some other things that can be found easily in the surroundings only usual material. The mission is making a machine that is enable to pass obstacle and to walk well. This paper followed the rules by regulation.

  • PDF

A fish-drying control method based on skilled worker's performance

  • Nakamura, Makoto;Fujimoto, Masakatsu;Sakai, Yoshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.379-384
    • /
    • 1994
  • In this paper, a fish-drying control method is proposed, which utilizes prediction of proper change in- weight of material fish based on skilled worker's performance. The function of the proposed system is largely broken down into two procedures: The procedure before drying and the one during drying. The procedure before drying is the determination of necessary drying conditions and the required drying time. Required drying time and proper changes in weight for a specific product are obtained by using fuzzy inference and regression models. The procedure during drying is the prediction of the state of material at the end of drying, or the state of product and regulation of drying conditions to attain the prescribed goal before drying. The prediction of product is obtained by using a set of linear-differential equations obtained by the authors' previous work. Drying conditions are regulated by using fuzzy inference. A good agreement between the results of simulation and experiments is obtained, which implies the usefulness of the present control method.

  • PDF

Technology of Electrical Barrier Material (전기차단성 소재 기술)

  • Shin, Eun-Mi
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.22-28
    • /
    • 2011
  • Various materials are used as electrical barrier materials, such as glass, insulating oil, gas, paper and polymer. These materials shut off electricity from conductor as a barrier and separate as well as support conductor from outside environment while using electrical equipment. Polymers are generally used for cable insulation material. Recently environmental regulation are reinforced and eco-friendly materials are in trend.

Development of a Measurement Tool for Radiation Safety Regulations (방사선안전규제 측정도구 개발)

  • Han, Eun-Ok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6203-6207
    • /
    • 2012
  • The aim of the study was to develop an objective measurement tool, which could measure radiation safety regulations as an advanced research to draw evidentiary conclusions for the rationalization of radiation safety regulations as organizations continuously increase consumption of radiation material. The survey was based on the contents of Vol 1~21 of US NRC NUREG 1556 (Consolidated Guidance About Materials Licenses) and material from the Nuclear Safety Act which was based on radiation safety managers who are responsible for about 10% of the domestic registered organizations for radiation usage. As a result of the analysis, 3 main causes were extracted based on 20 questions. Each causes were named as Cause 1: 'Radioactive Safety Regulations Requirements', Cause 2: 'Compatibility of Actual Safety Regulation', and Cause 3: 'RI/RG radiation Source Classification' respectively. The dispersal explanations of each causes were explained in total of 60.417% by 40.140% of Cause 1, 13.721% of Cause 2, and Cause 3 for 6.556% If radiation safety regulation standards are drawn using the radiation safety regulation measurement tool, which is suggested in this study, this could be not only comply with international standards but also could be used to propose a practical standard to domestic radiation safety managers.

Evaluation for Contents of Contaminants and Leaching Characteristics of Bottom Ash (바텀애쉬의 유해물질 함량 측정 및 용출특성 평가연구)

  • Koh, Taehoon;Lee, Sungjin;Shin, Minho;Kim, Byongsuk;Lee, Jeakeun;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we tried to determine any detrimental effects on water quality when bottom ash obtained from a coal-fired power plant intended to be used as a fill material in construction sites. Physical-chemical properties of bottom ash were determined using proximate analysis, elemental analysis, XRD, and XRF. Classification of bottom ash as a waste material and soil contamination due to the use of bottom ash were performed by Korea waste standard leaching test and soil toxicity test, respectively. Results of leaching tests were compared to the regulations for water quality and groundwater quality and no harmful effects on water quality were found. Most of heavy metals in leachate were below detection limits but trace amount of $Cr^{6+}$ was found. However, concentration of $Cr^{6+}$ was below the regulation criteria. Column leaching tests indicated that concentrations of Pb and Zn were slightly higher than regulations but below regulations within 1 PVE, but concentrations of sulfate were 10 times higher than regulation and thus, the required time to reach regulation was almost 8 PVE.

A Study on the Assessment of Hazardous Properties of the Chemicals (화학물질의 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Park, Chul-Woo;Song, Haak;Choi, Jeong-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.262-269
    • /
    • 2008
  • Chemical products have had an favorable influence on our everyday life, and contributed very much to the development of human culture. According to the rapid change of industry and the development of scientific technique the using chemical products are increasing more and more. Chemical products can have any hazardous property such as flammability or explosiveness. There are occurring many accidents in the international trade due to the different classification and labelling of chemicals produced in various countries. The main purpose of this work is the development of global standard test methods for the chemicals, and the classification and labelling in building block approach by means of the basic technical data. Oxidizing solids, combustible solids, spontaneously combustible materials, water-prohibitive materials, flammable liquids, self-reactive materials and oxidizing liquids have been tested. The results have been classified according to the hazard material safety regulation and the UN regulation, and summarized in a data-base.

  • PDF