• Title/Summary/Keyword: Material Testing

Search Result 2,012, Processing Time 0.03 seconds

Wear Behavior of Laser Modified SM45C Steel (레이저 표면개질된 SM45C강의 마멸거동)

  • 배춘익;옥철호;박흥식;전태옥
    • Tribology and Lubricants
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2000
  • Radiation of Nd-YAG laser changes and refines the surface microstructure of steels, which gives rise to enhancement of hardness and resulting wear resistance. In the present work, the effect of processing parameters during the surface modification with laser on the wear behavior of the SM45C steel was studied by means of wear testing. The counter material was alumina ceramics. The microstructure observation revealed the dependence of molten depth and width on the defocusing distance. The laser modification of steel surface give rise to improved wear resistance in the testing speed range of either <0.2 m/s or >0.9 m/s Material transfer from steel was wear observated the surface of counter material when testing speed was lower than 0.7 m/s.

Development of a Chloroform Reference Material for the Proficiency Testing of Hazardous Compounds in Commercial Consumer Chemical Products Under the Consumer Chemical Products and Biocide Safety Management Act (K-BPR)

  • Lee, Sang Tak;Lee, Jae-ung;Kim, Joo-Hyon;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • v.10 no.4
    • /
    • pp.112-116
    • /
    • 2019
  • In this study, a chloroform consumer chemical product (CCP) reference material (RM) is successfully developed, with potential to be used in the proficiency testing of hazardous compounds in CCPs for analysis and testing agencies. Validation experiments are rigorously conducted to evaluate whether the RM meets the requirements set by the ISO 13528 and ISO Guide 35, using a reliable GC/MS method for the analysis of chloroform. The obtained calibration plot linearity, limit of detection (LOD), and limit of quantitation (LOQ) are excellent. The developed RM meets the homogeneity and stability requirements; the between-unit (sbb) and within-unit (swb) standard deviations are less than 2.5%, and the stability is found to be guaranteed for 50 days.

A Study on Engineering Characteristics of Load Reducing Material EPS (도로성토하중경감재 EPS의 공학적 특성에 관한 연구)

  • Jang, Myeong-Sun;Cheon, Byeong-Sik;Im, Hae-Sik
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.59-70
    • /
    • 1996
  • The EPS has the unit weight of only 20~30kg/m3 and is used as one of the methods of reducing road embankment loads. Parts of it's applications are for backfill materials of structures like abutment, retaining wall, etc., to reduce horizontal earth pressure and for banking materials to secure the safety of settlement and bearing capacity by minimizing the stress Increment. However, the Korean Standards (KS) has not yet proposed any testing method for use of EPS as a engineering banking material. Only its testing and quality ordinance as a heat insulation material has been standardized. Therefore, in Korea, EPS is used as banking material without any systematic testing data as a civil engineering material. In this point of view, this paper deals with the engineering characteristics of EPS through many laboratory tests on strength, strain, absorption, and creep. from the results achived through tests, this paper proposes the enactment of a suitable quality testing ordinance and the criteria of unconfined design strength of EPS for use as engineering material.

  • PDF

Preliminary PINC(Program for the Inspection of Nickel Alloy Components) RRT(Round Robin Test) - Pressurizer Dissimilar Metal Weld -

  • Kim, Kyung-Cho;Kang, Sung-Sik;Shin, Ho-Sang;Chung, Ku-Kab;Song, Myung-Ho;Chung, Hae-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.248-255
    • /
    • 2009
  • After several damages by PWSCC were found in the world, USNRC and PNNL(Pacific Northwest National Laboratory) started the research on PWSCC under the project name of PINC. The aim of the project was 1) to fabricate representative NDE mock-ups with flaws to simulate PWSCCs, 2) to identify and quantitatively assess NDE methods for accurately detecting, sizing and characterizing PWSCCs, 3) to document the range of locations and morphologies of PWSCCs and 4) to incorporate results with other results of ongoing PWSCC research programs, as appropriate. Korea nuclear industries have also been participating in the project. Thermally and mechanically cracked-four mockups were prepared and phased array and manual ultrasonic testing(UT) techniques were applied. The results and lessons learned from the preliminary RRT are summarized as follows: 1) Korea RRT teams performed the RRT successfully. 2) Crack detection probability of the participating organizations was an average 87%, 80% and 80% respectively. 3) RMS error of the crack sizing showed comparatively good results. 4) The lessons learned may be helpful to perform the PINC RRT and PSI /ISI in Korea in the future.

A study on the development of phthalate plasticizers CRM in ABS resin (ABS 중 phthalates 가소제 CRM 개발에 대한 연구)

  • Jung, Jung-Sul;Park, Jung-Woo;Yoo, Seok;Kweon, Seong-Il;Hong, Sung-Taeg;Sun, Yle-Shik;Park, Cheon-Min;Choi, Chang-Hyoo
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.273-283
    • /
    • 2012
  • Phthalate plasticizers are regulated by RoHS, REACH and CPSC as hazardous substances. Responding to these international environmental restrictions, we developed ABS certified reference material (CRM) for determination of phthalate plasticizers such as DMP, DEP, DBP, BBP, DEHP and DnOP. The candidate material has been made with ABS resin widely used in electric and electronic products and 6 kinds of phthalate plasticizers. The making of the material involved a series of processes like extruding, cooling, pelletizing, and drying using twin screw extruder. Then it has been certified according to ISO Guide 35. Using isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS), homogeneity, short-term stability, and long-term stability were evaluated. The certified values were determined by using primary reference material (PRM) of KRISS for traceability. From now on, we will provide ABS CRM to national and international companies and research institutes after certification as certified reference material and registering on COMAR (code of reference material).

Effect of PEO Process Conditions on Oxidized Surface Properties of Mg alloy, AZ31 and AZ91. I. Applied Voltage and Time (PEO 처리조건에 따른 마그네슘 합금 AZ31과 AZ91의 산화표면피막특성에 대한 연구. I. 전압과 시간의 영향)

  • Ham, Jae-Ho;Jeon, Min-Seok;Kim, Yong-Nam;Shin, Min Chul;Kim, Kwang Youp;Kim, Bae-Yeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.218-224
    • /
    • 2016
  • The surface of Mg alloy, AZ31 and AZ91, were treated by PEO (plasma electrolytic oxidation) in Na-P system electrolyte, with different applied voltage and time. Thickness, roughness and X-ray crystallographic analysis revealed several results. The more applied time and voltage of PEO treated, the thicker oxidized surface coating layer were covered. And surface roughness increased with the thickness of oxidized layer. It was thought that when oxide layer grew, resistivity and breakdown voltage increased with the thickness of layer, and then, the energy of micro plasma need to be higher then before. So, it made craters and pores of surface become greater, which were responsible for the coarse surface.

Effect of PEO Process Conditions on Oxidized Surface Properties of Mg alloy, AZ31 and AZ91. II. Electrolyte (PEO 처리조건에 따른 마그네슘 합금 AZ31과 AZ91의 산화표면피막특성에 대한 연구. II. 전해질의 영향)

  • Ham, Jae-Ho;Jeon, Min-Seok;Kim, Yong-Nam;Shin, Hyun-Gyoo;Kim, Sung Youp;Kim, Bae-Yeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.225-230
    • /
    • 2016
  • Effect of electrolyte composition and concentration on PEO coating layer were investigated. Mg alloy, Surface of AZ31 and AZ91 were oxidized using PEO with different electrolyte system, Na-P and Na-Si. and applied voltage and concentration. We measured thickness, roughness, X-ray crystallographic analysis and breakdown voltage of the oxidized layer. When increasing concentration of electrolyte, the thickness of oxide layer also increased too. And roughness also increased as concentration of electrolyte increasing. Breakdown voltage of coated layer showed same behavior, the voltage goes high as increasing thickness of coating layer, as increasing concentration of electrolyte, and increasing applied voltage of PEO. $Mg_2SiO_4$ phase were observed as well as MgO.

Fabrication of Nano-Size Specimens for Tensile Test Employing Nano-Indentation Device (나노 인장시험을 위한 압축 시험기용 인장시편 제작에 관한 연구)

  • Lim, Tae Woo;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.911-916
    • /
    • 2015
  • In the nano/micro scale, material properties are dependent on the size-scale of a structure. However, conventional micro-scale tensile tests have limitations to obtain reliable values of nano-scale material properties owing to residual stress and elastic slippage in the gripping/aligning process. The indenter-driven nano-scale tensile test provides prominent advantages simple testing device, high-quality nano-scale metallic specimen with negligible residual stress. In this paper, two-types of specimens (a specimen with multi-testing parts and a specimen with a single-testing part) are discussed. Focused ion beam (FIB) is employed to fabricate a nano-scale specimen from a thin nickel film. Using the specimen with a single-testing part, we obtained a nano-scale stress-strain curve of electroplated nickel film.

On-line and Off-line Partial Discharge Monitoring System with HVAC Testing (HVAC에 의한 On-line, Off-line PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

The Development of HFPD System for Mibile-loading Vehicles (차량탑재형 HFPD의 개발)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF