• Title/Summary/Keyword: Material Safety Data Sheets (MSDS)

Search Result 37, Processing Time 0.028 seconds

Estimation of the Asbestos Handling History of Workers in the Automobile Manufacturing Industry in Korea (자동차 제조 사업장 근로자들의 석면 취급 이력 추정)

  • Choi, Sangjun;Kim, Shinbum;Choi, Youngeun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.423-432
    • /
    • 2017
  • Objectives: This study was conducted to evaluate asbestos handling history of workers at automobile manufacturing plants in Korea. Methods: National regulations on asbestos and Korea Occupational Safety and Health Agency(KOSHA) database on the information of asbestos containing products were reviewed. We investigated asbestos related materials from one automobile manufacturing plant. Material safety data sheets(MSDS) collected in 2010, work environment monitoring results reported from 2000 to 2013, trade union reports and asbestos survey reports were reviewed. We also interviewed workers with long career and did walk-through survey. Results: The Ministry of Labor in Korea has permitted asbestos manufacturing since 1990. In 1997, the use of crocidolite and amosite asbestos were banned. In 2007, the Korean government announced a total ban on the manufacturing, importation and use of all kinds of asbestos, which took full effect in 2009. A total of 174 asbestos products information from KOSHA database was analyzed. Extruded cement panel for building, special brake for crane farm machinery, gasket, joint sheet and thermal insulator were produced until 2007. From automobile manufacturing plant survey, we confirmed that asbestos containing materials(ACM) such as gasket, heating induction materials have been used until 2011. Asbestos containing building materials(ACBM) such as bamlites, slate and ceiling tex were reported at 122 asbestos dismantling projects in 2014. Conclusion: Although the use of all kinds of asbestos were banned from 2009, ACMs and ACBMs installed before 2009 were still found at automobile manufacturing plant until 2011 and 2014 respectively. In particular, asbestos slates should be managed because most of slates had not been removed until 2014.

Compositions and Contents of Thinner and Reliability of MSDS sold in Busan and Gyeongnam Province (부산,경남에서 판매되는 시너(Thinner)의 구성 성분 중 벤젠 등 일부 독성물질의 함량과 물질안전보건자료에 관한 연구)

  • Kim, Yu Young;Yang, Seung Hyuk;Lee, Jung Sil;Lee, Hyoung Sook;Jang, Kong Hwa;Jin, Koo Won;Lee, Yong Il;Joo, Woo Hong;Paik, Do-Hyeon;Kang, Dae-Ook;Moon, Ja-Young;Cho, Yong-Kweon;Park, Dong Uk;Yoon, Chung Sik;Ha, Kwon Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.314-323
    • /
    • 2006
  • This study was conducted to identify ingredients of thinners and to confirm reliability of material safety data sheets (MSDS) of thinners for public and workers' health. The 41 thinner products were collected from paint shops located in Busan and Gyeongnam province. The 12 thinner products among them were identified using product MSDS. GC-MSD was used to analyze 41 kinds of thinners qualitatively and quantitatively. The 12 products MSDS were compared with thinner's component through qualitative analysis to confirm MSDS. Chemical ingredients, such as Benzene, Toluene, and Xylene etc., of thinners were analysed in quantity. The 41 thinner products contained 17 disclosed specific, trade name, or generically described chemical solvent ingredients. These 17 ingredients came under 6 classes: alcohols, aromatic hydrocarbons, esters, glycol ethers, ketones, and mixtures. These 17 ingredients were important in the view of industrial hygiene and had occupational exposure limit in the ambient, such as toluene, xylene, acetone, nonane, EGEE, heptane, cumene, MIBK, indene, tri-methyl benzene, etc, were found in 41 kinds of thinners. Aromatic hydrocarbons were the most identified ingredient in thinners. Especially, the benzene, which induces leukemia, was found in 4 kinds of thinners. The content rates of benzene in thinners were 0.25~1.18%. The benzene in enamel thinner, which were 0.39~0.72%, was highest from chemical classification. The contents of toluene, which was found from 27 kinds of thinners, were 5.35~64.16%, which were highest in sobu thinner as 58.80%. Xylene was found from 22 kinds of thinners and contents of xylene were 4.61~72.42%. Acrylic thinner's contents of xylene were 12.06~51.05%, which was most high. It was found that contents of benzene were increased and frequency of detection was decreased through comparison with other study. The MSDS possession rate of paint shops was low as 29.27%. So it did not provide information with public or workers. Mean of agreement rate between MSDS and components of thinners through qualitative analysis was 42.01% and it has wide range from 8.3% to 75%. There are many deficiencies in MSDS about component of thinners. In some case of sample, expecially, despite containing benzene, information was not written it on MSDS.

Effect of Workplace Health Manager's Role Performance on Presenteeism in the Workers (보건관리자의 역할수행이 유병근로자의 출근으로 인한 업무손실에 미치는 영향)

  • Jung, Myung-Hee;Jung, Hye-Sun;Lee, Bok-Im
    • Korean Journal of Occupational Health Nursing
    • /
    • v.22 no.2
    • /
    • pp.171-178
    • /
    • 2013
  • Purpose: This study was conducted to determine the effect of the performance of Workplace Health Manager at the workplace on presenteeism in the workers. Methods: Three months before this study, between June 2010 and September 2010, a self-reporting survey of 316 employees in 136 workplaces in each of each hired a Workplace Health Manager was performed at their workplace with explanations of the purpose and methods of this study after their consent was obtained. Results: The average performance score of the Workplace Health Manager as graded by the employees was 3.8 out of 5 points. The duties of the Workplace Health Manager which received higher grades were posting of the Material Safety Data Sheets (MSDS), health education, and future management with respect to the results and procedure of health care-related work. According to the employees' survey, the score for presenteeism was evaluated as 14.3 out of 30 points. Based on the presenteeism analysis results, when (1) the employee was a male, (2) the workplace was established and managed by Industry Safety and Health Committee, (3) the employees were aware of the role of Workplace Health Managers, and (4) Workplace Health Manager fulfilled his/her role actively and successfully, presenteeism was observed to a lesser extent. Conclusion: According to the results of the study, presenteeism was observed to a lesser extent when the Workplace Health Manager actively performed his/her role.

Review of Problems with Use of Halogenated Cleaning Solvents Revealed through Case Studies of Cleaning Solvent Poisoning and Analysis of Domestic and Overseas Regulations (세척제 용매 중독 사례와 국내·외 규제 검토를 통한 할로겐화 용매 세척제 사용의 문제점 고찰)

  • Naroo Lee;Hye Jin Lee;Sujin Jeong;Dohee Lee;Arom Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.517-527
    • /
    • 2023
  • Objectives: We examine cases of chemical poisoning that occurred in the cleaning of metal parts and the regulations on halogenated solvents in other countries and propose regulations necessary to prevent chemical poisoning from halogenated solvents. Methods: We collected cases of chemical poisoning through the website of the Korea Occupational Safety and Health Agency. A review of the literature was conducted focusing on regulations related to halogenated solvents in the United States and the European Union, particularly for cleaning metal parts. Among the Material Safety Data Sheets submitted to the government, MSDS containing eleven substances were extracted to confirm the composition and product use. We investigated cleaning methods for metal parts used in South Korea. For the hazard classification, the European Chemicals Agency or Japan's NITE's website was used. Results: In the case of poisoning, the cleaning methods involving trichloromethane were dipping and dry, which was not found in the literature. It was confirmed that many halogenated solvents and dimethyl carbonate were used for metal cleaning in South Korea. In vapor degreasing using TCE in the USA, even if the facility is strictly managed, such as by installing cooling coils in open cleaning facilities, the risk of exposure to TCE is considered to be not only carcinogenic but also a concern for acute and chronic effects. In comparison, exposure through Korean work methods such as dipping and drying operations is inevitably much higher. Conclusions: The transition to water-based cleaning with low-hazard chemicals should be a priority in the cleaning process. In the case of metal parts that require precise cleaning, if the use of a halogenated solvent is inevitable, a closed degreasing facility should be used to minimize exposure. The current regulations in the Occupational Safety and Health Act, the Chemical Substances Control Act, and the Air Environment Conservation Act do not require cleaning facilities to minimize emissions. To protect the health of workers using halogenated solvents to clean metal parts, regulations that require a fundamental reduction in exposure will be necessary.

Critical Review on Carcinogenicity of Metalworking Fluids (절삭유(Metalworking Fluids)의 발암성에 대한 고찰)

  • 박동욱;윤충식;이송권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.50-62
    • /
    • 2003
  • Exposure to metalworking fluids (MWFs) has significantly been associated with cancer developed in multi-organs, respiratory diseases and skin diseases. Several carcinogens to humans or animals are contained in MWFs. They have been reported to be mineral oils, polynuclear aromatic hydrocarbons (PAHs), formaldehyde and N-nitrosodiethanolamine (NDELA). The great hazards of MWF have forced the advanced country including United States to regulate carcinogens contained in MWF. In 2001, American Conference of Governmental Industrial Hygienists (ACGIHs) regarded MWF mist as suspected carcinogen to human (A2) and added it to “Notice of Intended Change (NIC)” list of 2001. In spite of the fact that much MWF has widely been used in many industries using machines, Korea has no legal actions for management of MWF. What is worse, even toxicity such as Carcinogenicity has not been reported. KS (Korean Standards) lists 7 advices of MWF but it does net state the hazards to health. It is very hard to control or minimize worker's exposure to MWF containing many carcinogens. Prier to the introduction of MWF to workplace, it is the most effective measure to regulate carcinogens below a certain level. Regulation on the content of PAH seems to be necessary because less amount of PAH in mineral oils improves the quality of MWF. Also, addition of nitrosating groups to MWF should be prohibited to minimize worker's exposure to NDELA. Employers and manufacturers should indicate the Carcinogenicity of all carcinogens in MWFs in Material Safety Data Sheets (MSDS) in order fer workers to recognize Carcinogenicity. Legal actions have to be taken to protect workers from health hazards due to exposure to MWF by further investigation on MWF.

Ethanolamine and boron abuse to limit microbial growth in water-synthetic metalworking fluids (미생물 성장을 억제하기 위하여 수용성 절삭유에 과다하게 첨가한 붕소와 아민 사례 연구)

  • Park, Donguk;Paik, Dohyeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.270-276
    • /
    • 2005
  • This study was conducted to examine whether a specific synthetic metalworking fluid (MWF), "A", in use for 10 months without replacement, displayed microbial resistance and to identify the additives associated with the control of microbial growth. Three synthetic MWF products ("A", "B", and "C") were studied every week for two months. Microbial deterioration of the fluids was assessed through evaluation by endotoxin, bacteria and fungi levels in the MWFs. In addition, formaldehyde, boron, ethanolamine, and copper levels were also studied to determine whether they influence microbial growth in water-based MWFs. Throughout the entire study in the sump where MWF "A" was used, bacteria counts were lower than 103 CFU/mL, and endotoxins never exceeded 103 EU/mL. These levels were significantly lower than levels observed in sumps badly deteriorated with microbes. Boron levels in MWF "A" ranged from 91.7 to 129.6 ppm, which was significantly higher than boron levels found in other MWF products. The total level of ethanolamine (EA) in MWF "A" ranged from 35,595 to 57,857 ppm (average 40,903 ppm), which was over ten times higher than that found in other MWFs. Monoethanolamine (MEA), diethanolamine (DEA) and triethanolamine (TEA) concentrations in MWF "A" were also significantly higher than seen in other MWFs. However, although EA and boron might improve anti-microbial performance, their abuse can pose a serious risk to workers who handle MWFs. From an industrial hygiene perspective, our study results stress that the positive synergistic effect of boron and EA in reducing microbial activity in MWF must be balanced with the potentially negative health effects of such additives. Our study also addresses the disadvantage of failing to comprehensively report MWF additives on Material Safety Data Sheets (MSDS). Future research in MWF formulation is needed to find the best level of EA and boron for achieving optimal synergistic anti-microbial effects while minimizing employee health hazards.

Chemical Disaster of Methyl Isocyanate Leakage (화학물질 누출에 의한 대량재해 - Methyl Isocyanate 누출을 중심으로 -)

  • Yang, Hyuk-Jun;Choi, Jung-Myung;Yoo, Dong-Jun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.3 no.1
    • /
    • pp.7-19
    • /
    • 1999
  • Background : We are in the edge of some human made disasters such as hazardous materials and air pollution, for example, the world news reported that the city of Bhopal, India had serious victims related with a leaking out of the chemical materials, Methyl Isocyanate and many people in India were killed by. These situations many people who live in this world are world are worrying about are not others, but just ours and people consider about that kind of the disasters are the possible situation to happen to all the people. Therefore, we performed this basic study to recognize the risk of Methyl Isocyanate leak accident and to prepare local disaster plan with EMS system. Method : Trace 8.0, a simulation software made by the U.S. company Safer System was used as a tool to estimate the diffusion distance, area and its victims at the concentrations of 0.02ppm, 0.2ppm 5ppm respectively for an assumed B-city of 2 hundred thousands population count in which was presumed 500kg Methyl Isocyanate gas to leak out. Results : 1. During 1 hour, maximum diffusion distances of 0.02ppm 0.2ppm and 5ppm were 5.41km, 1.61km and 0.29km respectively on the plume impact. 2. Maximum population counts influenced by Methyl Isocyanate gas at the concentrations of 0.02ppm 0.2ppm and 5ppm were 40838, 4346 and 222 on the plume impact, while those were 138238, 17261 and 1588 on the vulnerability impact, respectively. 3. Therefore, 17261 persons must put on respiratory device and 138283 persons must be evacuated to safety place within 1 hour. Conclusions : Only small amount leak of Methyl Isocyanate may cause tremendous chemical disaster in urban area, so its disaster plan must be prepared with an accident simulation program and Material Safety Data Sheets(MSDS). Especially, nearby emergency center of an industrial complex must have a strong position about preparation of chemical disaster plan and perform a disaster dill of hazardous material accident annually.

  • PDF