• 제목/요약/키워드: Material Defects

검색결과 1,315건 처리시간 0.034초

Stress distribution in bone surrounding maxillary molar implants under different crown-to-fixture ratio: A 3D FEM analysis (치관/고정체 비에 따른 상악 구치부 임플란트 주변골의 응력 분포에 대한 3차원 유한요소법적 분석)

  • Park, Jong-Chan;Shin, Sang-Wan;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제46권5호
    • /
    • pp.479-489
    • /
    • 2008
  • Statement of the problem: Under anatomical limitations on maxillary posterior region, a poor crown-to root ratio acting on dental implants can result in undesirable stress in surrounding bone, which in turn can cause bone defects and eventual failure of implants. Purpose: The purpose is to compare stress distribution due to different crown-root ratio and effect of splinting between natural teeth and implants in maxillary molar area under different loads. Material and methods: Analysis of stress arising supporting bone of the natural teeth and the implant was made with 3-dimensional finite element method. The model simulated naturel teeth was made with 2nd premolar and 1st molar in the maxillary molar region (Model T). The model simulated implants placed on same positions with two parallel implants of Straumann Dental Implant cemented abutment (Model I). Each model was designed in different crown-root ratio (0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it non-splinted or splinted. After that, 300 N force was loaded to each model in five ways (Load 1: middle of occlusal table, Load 2: middle of buccal cusp, Load 3: middle of lingual cusp, Load 4: horizontal load to buccal cusp of anterior abutment only, Load 5: horizontal load to middle of buccal cusp of each abutment), and stress distribution was analyzed. Results and conclusion: On all occasions, stress was concentrated at the cervical region of the implant. Under load 1, 2 and 3, stress was not increased even when crown-root ratio increases, but under load 4 and 5, when crown-root ratio increases, stress also increased. There was difference in stress values between natural teeth and implants when crown-root ratio gradually increases; In case of natural teeth, splinting decreased stress under vertical and horizontal loads. In case of implants, splinting decreased stress under vertical loads 1,2 and 3, but increased maximal stress under loads 2 and 3. Under horizontal loads, splinting decreased stress, however the effect of splinting decreased under load 5 than load 4. Furthermore, the stress was increased, when crown-root ratio is 1.25:1. Clinical implications: This limited finite element study suggests that the stress on supporting bone may be increased under non-axial loads and poor crown-root ratio. Under poor crown-root ratio, excessive stress was generated at the cervical region of the implant, and decreased splinting effect for stress distribution, which can be related to clinical failure.

The effect of enamel matrix derivative (EMD) in combination with deproteinized bovine bone material (DBBM) on the early wound healing of rabbit calvarial defects (법랑기질 단백질 유도체와 혼합된 이종골 이식재가 토끼 두개골 결손부 초기 치유에 미치는 영향)

  • Kim, You-Seok;Jang, Hyun-Seon;Park, Ju-Chol;Kim, Heoung-Jung;Lee, Jong-Woo;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • 제35권1호
    • /
    • pp.199-216
    • /
    • 2005
  • 치주치료의 가장 중요한 목적은 상실된 치주조직의 형태적, 기능적 재건이다. 법랑기칠 단백질 유도체(enamel matrix derivative: EMD)는 치주 병소에 사용시 상피세포의 증식을 억제하며 치주인대 및 백악아세포를 활성화시켜 무세포성 백악질 및 치주인대와 골조직의 생성을 유도한다고 보고되고 있다. 또한 법랑기질 단백칠 유도체는 골모세포의 증식 및 분화를 촉진시키며 alkaline phosphatase의 활성 및 mineralized nodule의 형성을 촉진시킨다고 보고되고 있다. 이에 본 연구에서는 토끼 두개골 결손부에 법랑기질 단백질 유도체와 이종골 이식재를 이식한 후 골밀도를 방사선학적으로 분석하고, 신생골 형성 및 주변 조직 반응을 조직학적으로 관찰, 평가하고자 하였다. 토끼 두개골에 6mm trephine bur(외경 8mm)를 이용하여 경뇌막에 손상을 주지 않도록 하면서 4개의 결손부를 형성하였다. 아무것도 이식하지 않은 군을 음성 대조군으로, 이종골 이식재 ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland)을 이식한 군을 양성 대조군으로 설정하였다. 법랑기질 단백질 유도체 ($Emdogain^{(R)}$, Biora, Inc., Sweden)만 이식한 군과 법랑기질 단백질 유도체와 이종골 이식재를 혼합하여 이식한 군을 설험군으로 설정하였다. 각각의 재료를 이식한 후 비흡수성 차폐막 ($Tefgen^{(R)}$, Lifecore Biomedical, Inc., U.S.A.)을 위치시키고 흡수성 봉합사로 일차봉합을 시행하였다. 각 군당 술 후 1, 2, 4주의 치유기간을 설정하였다. 동물을 희생시킨 후 두개골을 절제하여 먼저 방사선학적인 골밀도측정을 시행한 후 10% formalin에 고정한 후 통법에 따라 조직표본을 제작하여 광학현미경으로 관찰하였다. 1. 방사선학적인 평가에서 1, 2, 4주에 대조군과 법랑기질 단백질 유도체만 이식한 군과 비교해 이종골 이식재만 이식한 군과 이종골 이식재에 법랑기질 단백질 유도체를 이식한 군에서 더 큰 골의 밀도를 보이고 있었다 (P<0.01). 하지만, 동일한 시기에 대조군과 법랑기질 단백질 유도체만 이식한 군과의 차이는 발견할 수 없었으며 (P>0.05), 이종골 이식재만 이식한 군과 이종골 이식재에 법랑기질 단백질 유도체를 이식한 군의 차이 또한 발견할 수 없었다 (P>0.05). 2. 조직학적인 평가에서 1, 2, 4주에 대조군과 법랑기질 단백질 유도체만 이식한 군과 비교해 이종골 이식재만 이식한 군과 이종골 이식재에 법랑기질 단백질 유도체를 이식한군에서 골의 형성이 더 진행됨을 알 수 있었다. 법랑기질 단백질 유도체만 이식한 군이 대조군보다 2주에서 더 많은 신생골을 볼 수 있었으며, 이종골 이식재에 법랑기질 단백질 유도체를 이식한 군이 이종골 이식재만 이식한 군보다 1, 2주에서 더 많은 신생골을 관찰할 수 있었다. 이상의 결과에서 법랑기질 단백질 유도체는 토끼 두개골 결손부 치유단계에서 초기 골 형성을 촉진하는 것으로 사료되며 골 이식시에 법랑기질 단백질 유도체를 적용하는 것은 유용한 술식으로 사료된다.

Extending the Shelf-life of Yukwa Using Secondary Packaging (이차포장을 통한 유과의 저장성 연장)

  • Jung, Jun-Jae;Lee, Keun-Taik
    • Korean Journal of Food Science and Technology
    • /
    • 제42권4호
    • /
    • pp.452-458
    • /
    • 2010
  • This study aimed at improving the packaging technology of Yukwa to improve the quality and extend the shelflife using secondary packaging. After packaging the Yukwa using an OPP film, P2, P3, and P4 packaging materials were applied secondarily. Various films including (1) P1: OPP (oriented polypropylene), (2) P2: P1+OPP/LLDPE (linear low density polyethylene), (3) P3: P1+PET (polyethylene terephthalate)/NY (nylon)/CPP (cast polypropylene) and (4) P4: P1+PET/AL (aluminum)/NY/CPP (P4) were used for packaging Yukwa. The experiment was conducted at $25^{\circ}C$ for 12 weeks. P1 showed the highest acid value score (1.26 mg KOH/g), and P3 had the highest peroxide value score (32.91 meq/kg) among all packaging groups. Nevertheless, these values did not exceed the guideline values of 2.0 g KOH/g and 40 meq/kg specified in the Korean food code. The overall color difference showed a tendency for decreasing Hunter 'L' values and increasing 'a' and 'b' values; however, no noticeable difference in the outer appearance was observed in any of the packaging treatments except in the P1 for greater than 10 weeks of storage. Some texture defects were observed in the Yukwa when the moisture contents dropped below 5%. The P4 packaging treatment had the lowest moisture permeability and showed the least rheological deterioration change, followed by P3 and P2. In conclusion, the use of a secondary packaging with less gas and moisture permeability was more effective for maintaining the quality and extending the shelf-life of Yukwa than other types of packaging material.

Development of Porcine Pericardial Heterograft for Clinical Application (Tensile Strength-thickness) (돼지의 심낭을 이용한 이종이식 보철편의 개발 (장력-두께간의 구조적 특성))

  • Kim, Kwan-Chang;Lee, Cheul;Choi, Chang-Hue;Lee, Chang-Ha;Oh, Sam-Sae;Park, Seong-Sik;Kim, Kyung-Hwan;Kim, Woong-Han;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • 제41권2호
    • /
    • pp.170-176
    • /
    • 2008
  • Background: Bioprosthetic devices for treating cardiovascular diseases and defects may provide alternatives to autologous and homograft tissue. We evaluated the mechanical and physical conditions of a porcine pericardial bioprosthesis treated with Glutaraldehyde (GA), Ethanol, or Sodium dodecylsulfate (SDS) before implantation. Material and Method: 1) Thirty square-shaped pieces of porcine pericardium were fixed in 0.625%, 1.5% or 3% GA solution. 2) The tensile strength and thickness of these and other bioprosthesis, including fresh porcine pericardium, fresh human pericardium, and commercially produced heterografts, were measured. 3) The tensile strength and thickness of the six treated groups (GA-Ethanol, Ethanol-GA, SDS only, SDS-GA, Ethanol-SDS-GA and SDS-Ethanol-GA) were measured. Result: 1) Porcine pericardium fixed in 0.625% GA the thinnest and had the lowest tensile strength, with thickness and tensile strength increasing with the concentration of GA solution. The relationship between tensile strength and thickness of porcine pericardium increased at thicknesses greater than 0.1mm (correlation-coefficient 0.514, 0<0.001). 2) There were no differences in tensile strength or thickness between commercially-produced heterografts. 3) Treatment of GA, ethanol, or SDS minimally influenced thickness and tensile strength of porcine pericardium, except for SDS alone. Conclusion: Porcine pericardial bioprosthesis greater than 0.1 mm thick provide better handling and advantageous tensile strength. GA fixation did not cause physical or mechanical damage during anticalcification or decellularization treatment, but combining SDS-ethanol pre-treatment and GA fixation provided the best tensile strength and thickness.

한국수출산업을 위한 산업디자인 개선에 관한 연구 -시각.공예.제품디자인을 중심으로-

  • 박대순
    • Archives of design research
    • /
    • 제1권1호
    • /
    • pp.1-162
    • /
    • 1980
  • The Design Society of Korea. It is our urgent task that we should map out our detailed guiedlines for the improvement of export-oriented industries and of the design of export goods in preparation for our export goal of $30 billion in the upcoming 1980s. The government, university design researchers, and most entrepreneurs have confronted diverse kinds of racking issues: how much do most export industries take advantage of the indus-trial design for the improvement of the quality of export goods\ulcorner, structural defects of most export industries, chronic and vicious cycle of overlooking the value of the industrial design in the process of manufacturing export goods and etc. In other words, the recent trend of slighting the industrial design is to speed up the sales of only unsophisticated goods on the international markets. Although Koreans have been plagued by scantiness of natural resources under these circumstances, most Korean people have showed off their strong will for today's growth. Furthermore, most exporters should do their best to sweep overseas markets by manufacturing sophisticated goods outranking those commodi-ties made by the United States, Japan, West Germany and the other developed countries. In this respect, we have to make our best efforts for the expensive application and practical use of the industrial design, one of the comprehensive sciences, in the face of the hard realities and conditions which we have confronted until now. For example, it can be attributed to the practical application of the industrial design that the neighboring Japan, West Germany, France, the United Kingdom in Europe, and the United States in North America have formulated a highly advan-ced cultural zone and braced up for their own trade protection-ism and tightened their embargoes on EEC goods. Unless any export goods take the best advantage of the industrial design, one of the behavioral sciences capable of satisfying the material mental needs of modern men and of promoting cultural growth, I am convinced that they will not infiltrate into any countries that have enjoyed their own highly cultural lives. It is absolutely important that most Korean universities, state-run, private corporations and research institutes should work out the improvement strategy for the development and practical use of the industrial design as will as the revision of the present curricula of the departments of design. However, most design researchers have come to grips with several difficult problems such as the correlation of export oriented industries and the industrial design and the development of the design of export goods. The improvement of the industrial design is our urgent assignment that we have to solve in the 1980s. Accordimgly, I cannot too much emphasize the value the recognition of the industrial design in our industrial communities because we have never witnessed the prosperity of those countries which have taken little notice of the importance of the industrial design. Hopefully, most entrepreneurs will take much consideration of the value of the industrial design and then can defeat their rival businessmen on the international markets by exporting goods of highly sophisticated design. In this respect, the main purpose of the research paper which this society presented is to underline the fact that the improvement and development of the industrial design is our common assignment to be studied from the viewpoints of national dimension as well as in conformity with our immediate goal for the export-oriented prosperity of state. In conclusion, I would like to highlight the fact that our export goods shall be continually developed in pace with the correlative improvement of the indudtrial design so as to pave the way for their bright prospect and to enhance their best impression of the first-class goods on the international markets.

  • PDF

Evaluation of clinical status of removable partial dentures (가철성 국소의치의 임상적 상태에 대한 평가)

  • Yang, Dong-Seok;Cho, Uk;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제47권3호
    • /
    • pp.320-327
    • /
    • 2009
  • Statement of Problem: Although many efforts have been continually made to estimate long term prognosis of removable partial dentures, the complication of removable partial dentures was still found because of inaccurate fabrication procedure and improper maintenance care. Purpose: The purpose of this study was to evaluate the clinical status of removable partial dentures. Material and methods: A total of 112 individuals with 153 removable partial dentures (35 - 87 years, 64 women and 48 men) were examined by intra-oral examination, diagnostic cast and radiographic examination. Results and conclusion: The results of this study were as follows: 1. Length of service of removable partial dentures was $5.3{\pm}4.3$ years (mean), 4.0 years (median). 2. A total of 45 removable partial dentures were considered failures. The loss of 18 abutments of 369 was founded. 3. Type of arch, Kennedy classification and type of opposite dentition were found to have no influence on longevity and success rate of removable partial dentures (P > .05). 4. Most common major connector was the palatal plate in maxilla and the number of lingual bar and linguoplate designed in mandible were similar. 5. The circumferential type retainer was the most commonly used retainer. 6. Sixty-three percent of the class I and II removable partial dentures incorporated indirect retention into the design. 7. Approximately 81% of the removable partial dentures had at least one defect. Excessive wear of posterior teeth (27.9%), lack of integrity (23.2%), lack of stability (22.6%) were frequent defects of removable partial dentures.

COATED PARTICLE FUEL FOR HIGH TEMPERATURE GAS COOLED REACTORS

  • Verfondern, Karl;Nabielek, Heinz;Kendall, James M.
    • Nuclear Engineering and Technology
    • /
    • 제39권5호
    • /
    • pp.603-616
    • /
    • 2007
  • Roy Huddle, having invented the coated particle in Harwell 1957, stated in the early 1970s that we know now everything about particles and coatings and should be going over to deal with other problems. This was on the occasion of the Dragon fuel performance information meeting London 1973: How wrong a genius be! It took until 1978 that really good particles were made in Germany, then during the Japanese HTTR production in the 1990s and finally the Chinese 2000-2001 campaign for HTR-10. Here, we present a review of history and present status. Today, good fuel is measured by different standards from the seventies: where $9*10^{-4}$ initial free heavy metal fraction was typical for early AVR carbide fuel and $3*10^{-4}$ initial free heavy metal fraction was acceptable for oxide fuel in THTR, we insist on values more than an order of magnitude below this value today. Half a percent of particle failure at the end-of-irradiation, another ancient standard, is not even acceptable today, even for the most severe accidents. While legislation and licensing has not changed, one of the reasons we insist on these improvements is the preference for passive systems rather than active controls of earlier times. After renewed HTGR interest, we are reporting about the start of new or reactivated coated particle work in several parts of the world, considering the aspects of designs/ traditional and new materials, manufacturing technologies/ quality control quality assurance, irradiation and accident performance, modeling and performance predictions, and fuel cycle aspects and spent fuel treatment. In very general terms, the coated particle should be strong, reliable, retentive, and affordable. These properties have to be quantified and will be eventually optimized for a specific application system. Results obtained so far indicate that the same particle can be used for steam cycle applications with $700-750^{\circ}C$ helium coolant gas exit, for gas turbine applications at $850-900^{\circ}C$ and for process heat/hydrogen generation applications with $950^{\circ}C$ outlet temperatures. There is a clear set of standards for modem high quality fuel in terms of low levels of heavy metal contamination, manufacture-induced particle defects during fuel body and fuel element making, irradiation/accident induced particle failures and limits on fission product release from intact particles. While gas-cooled reactor design is still open-ended with blocks for the prismatic and spherical fuel elements for the pebble-bed design, there is near worldwide agreement on high quality fuel: a $500{\mu}m$ diameter $UO_2$ kernel of 10% enrichment is surrounded by a $100{\mu}m$ thick sacrificial buffer layer to be followed by a dense inner pyrocarbon layer, a high quality silicon carbide layer of $35{\mu}m$ thickness and theoretical density and another outer pyrocarbon layer. Good performance has been demonstrated both under operational and under accident conditions, i.e. to 10% FIMA and maximum $1600^{\circ}C$ afterwards. And it is the wide-ranging demonstration experience that makes this particle superior. Recommendations are made for further work: 1. Generation of data for presently manufactured materials, e.g. SiC strength and strength distribution, PyC creep and shrinkage and many more material data sets. 2. Renewed start of irradiation and accident testing of modem coated particle fuel. 3. Analysis of existing and newly created data with a view to demonstrate satisfactory performance at burnups beyond 10% FIMA and complete fission product retention even in accidents that go beyond $1600^{\circ}C$ for a short period of time. This work should proceed at both national and international level.

The Bone regenerative effects of tetracycline blended chitosan membranes on the calvarial critical size defect in Sprague dawley rats (백서 두개골 결손부에서 항생제를 함유한 키토산 차단막의 골재생 유도 효과)

  • Chae, Gyung-Joon;Kim, Tae-Gyun;Jung, Ui-Won;Lee, Soo-Bok;Jung, Yong-Sik;Lee, Yong-Keun;Kim, Chang-Sung;Chae, Jung-Kiu;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.1019-1037
    • /
    • 2005
  • The major goals of periodontal therapy are the functional regeneration of periodontal supporting structures already destructed by periodontal disease as well as the reduction of signs and symptoms of progressive periodontal disease. There have been many efforts to develop materials and therapeutic methods to promote periodontal wound healing. There have been increasing interest on the chitosan made by chtin. Chitosan is a derivative of chitin made by deacetylation of side chains. Chitosan has been widely studied as bone substitution and membrane material in periodontology. Many experiments using chitosan in various animal models have proven its beneficial effects. Tetracycline has been considered for use in the treatment of chronic periodontal disease and gingivitis. The aim of this study is to evlauate the osteogenesis of tetracycline blended chitosan membranes on the calvarial critical size defect in Sprague Dawley rats. An 8mm surgical defect was produced with a trephine bur in the area of the midsagittal suture. The rats were divided into five groups: Untreated control group versus four experimental group. Four types of membranes were made and comparative study was been done. Two types of non-woven membranes were made by immersing non-woven chitosan into either the tetracycline solution or chitosan-tetracycline solution. Other two types of sponge membranes were fabricated by immersing chitosan sponge into the tetracycline solution, and subsequent freeze-drying. The animals were sacrificed at 2 and 8 weeks after surgical procedure. The specimens were examined by histologic analyses. The results are as follows: 1. Clinically the use of tetracycline blended chitosan membrane showed great healing capacity. 2. The new bone formations of all the experimental group, non-woven and sponge type membranes were greater than those of control group. But, there was no significant difference between the experimental groups. 3. Resorption of chitosan membranes were not shown in any groups at 2 weeks and 8 weeks. These results suggest that the use of tetracycline blended chitosan membrane on the calvarial defects in rats has significant effect on the regeneration of bone tissue in itself. And it implicate that tetracycline blended chitosan membrane might be useful for guided tissue regeneration.

Quality characteristics of ground coffee extracts according to physical and chemical defects (커피빈의 물리화학적 결점에 따른 추출액의 품질특성)

  • Sung, Jun-Hyung;Cho, Jeong-Seok;Lee, Hyeon-Jeong;Choi, Ji-Young;Lee, Yeong-Min;Luo, Jin;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • 제23권5호
    • /
    • pp.638-644
    • /
    • 2016
  • To examine the utilization possibility of defective coffee beans, non-defective and defective coffee bean were compared by means of its physiochemical properties and antioxidant capacities measured by DPPH radical scavenging activity, FRAP assay, total phenol contents, functional component (trigonelline, caffeine, chlorogenic acid) contents. After roasting process, pH and soluble solid contents of coffee extracts decreased; $L^*$ value decreased while $a^*$ and $b^*$ values increased. DPPH radical scavenging activities of defective green bean extracts were higher than that of non-defective green bean extracts. Immature green bean extract showed the highest radical scavenging activity. In FRAP assay, green bean extracts ranged from 15.28~21.80 mM TE which was higher than roasted bean extracts which showed 14.81~16.38 mM TE. Total phenol contents of green bean extracts ranged 191.06~256.25 mg% GAE which was higher than that of roasted bean extracts showed 161.91~173.44 mg% GAE. The contents of trigonelline, caffeine, chlorogenic acid in immature green bean extract were the highest, which showed 895.20 mg/L, 825.85 mg/L and 3,836.94 mg/L respectively. Each contents were decreased after roasting process. Results of this study suggest that defective coffee bean can be used as a functional food material.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 한국펄프종이공학회 2000년도 제26회 펄프종이기술 국제세미나
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.