• 제목/요약/키워드: Material Changes

검색결과 3,633건 처리시간 0.033초

관재료 및 피복재료별 농경지 암거배수 효과 분석 (Analyses of subsurface drainage effects of farmland with respect to pipe and envelop material)

  • 정상옥
    • 한국농공학회지
    • /
    • 제37권5호
    • /
    • pp.53-61
    • /
    • 1995
  • Analyses of subsurface drainage effects of farmland with respect to pipe and envelop material are made by the laboratory experiments using soil box to give basic information for the subsurface drainage system planning and design. Three different diameter PVC perforated pipes and a mesh pipe are used with envelop materials such as sand, rice bran, and crushed stone. Steady state subsurface drainage flow rate increased as envelop material changed from sand to rice bran and crushed stone. This indicates that as the hydraulic conductivity of the envelop material increases, the drainage flow rate increases. On the other hand, for a given envelop material, the mesh pipe which has the largest openning area shows the largest flow rate while small diameter PVC pipes show small flow rates. This tells that as the openning area and pipe diameter increase, the flow rate increases, too. Therefore, selection of pipe and envelop material should be made in accordance with the design drainage flow rate. Unsteady state subsurface drainage flow rate with respect to time differs for different envelop material. In case the sand was used as an envelop material, the small diameter PVC pipes show larger flow rates than the large diameter PVC pipe and mesh pipe. When the rice bran was used, the mesh pipe shows the largest flow rate, while small diameter pipes show smaller flow rates. In case the crushed stone was used as an envelop material, the large diameter PVC pipe and mesh pipe show larger flow rates, while small diameter pipes show a little bit smaller flow rates. However, the variation of flow rates among different pipes is the smallest when the crushed stone is used. The flow rate curve with respect to the pipe changes little for the crushed stone envelop which has a large hydraulic conductivity, while that changes much for the sand and rice bran envelops. However, it is difficult to draw a consistent relationship between the drainage flow rate and pipe for all the envelop materials. Since the subsurface drainage experiments are made only under the restricted laboratory condition in this study, further study including field experiment is required.

  • PDF

임플란트 보철의 교합 접촉 변화에 대한 임상적 평가 (Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis)

  • 윤철희;김대곤;이양진;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Effects of Material Properties and Fabric Structure Characteristics of Graduated Compression Stockings (GCS) on the Skin Pressure Distributions

  • Liu Rong;Kwok Yi-Lin;Li Yi;Lao Terence-T;Zhang Xin
    • Fibers and Polymers
    • /
    • 제6권4호
    • /
    • pp.322-331
    • /
    • 2005
  • Graduated compression stockings (GCS) have been widely used for the prophylaxis and treatment of venous diseases. Their gradient pressure function largely related to their fabric structure and material properties. By combing fabric physical testing and wear trials, this study investigated the GCSs fabric structure and material properties at different locations along the stocking hoses, and quantitatively analyzed the effects of fabrics on skin pressure longitudinal and transverse distributions. We concluded that, Structural characteristics and material properties of stocking fabrics were not uniform along the hoses, but a gradual variation from ankle to thigh regions, which significantly influenced the corresponding skin pressure gradient distributions; Tensile (WT, EM) and shearing properties (G) generated most significant differences among ankle, knee and thigh regions along the stocking hose, which significantly influenced the skin pressure lognitudinal gradient distribution. More material indices generating significant gradual changes occurred in the fabric wale direction along stocking hose, meaning that materials properties in wale direction would exert more important impact on the skin pressure gradient performances. And, the greater tensibility and smoother surface of fabric in wale direction would contribute to put stocking on and off, and facilitate wearers' leg extension-flexion movements. The indices of WT and EM of stocking fabrics in series A have strong linear correlations with skin pressure lognitudinal distribution, which largely related to their better performances in gradual changes of material properties. Skin pressure applied by fabric with same material properties produced pronounced differences among four different directions around certain cross-sections of human leg, especially at the ankle region; and, the skin pressure magnitudes at ankle region were more easily influenced by the materials properties, which were considered to be largely related to the anatomic structure of human leg.

스핀 스프레이 방식으로 제조된 바륨계 페라이트 박막의 EMI (Electromagnetic Interference) 차폐 특성 (EMI (Electromagnetic Interference) Shielding Properties of Barium-Based Ferrite Thin Films Prepared by Spin Spray Method)

  • 오혜령;박연주;이우성;유찬세;유명재;서인태
    • 한국전기전자재료학회논문지
    • /
    • 제37권2호
    • /
    • pp.195-201
    • /
    • 2024
  • The low-temperature deposition of BaNi(2-x)CoxFe16O27 thin films with a Ba hexaferrite structure for electromagnetic shielding was studied. The BaNi(2-x)CoxFe16O27 thin films produced through the spin spray process were suitable for thin film deposition on a flexible substrate because it crystallized well at low temperature below 90℃. The change in shielding characteristics depending on the Co content of the BaNi(2-x)CoxFe16O27 thin film was investigated, and excellent shielding characteristics with S21 of -1 dB were obtained in a wide frequency range of 26~40 GHz when the Co content was 0.4 or more. The purpose of this study is to analyze changes in shielding properties caused by change in Co content in relation to phase changes in BaNi(2-x)CoxFe16O27 and obtain basic data for developing excellent flexible electromagnetic wave shielding materials.

의료보험 실시후 2년간의 진료양상의 변화 -서울시내 의료기관 입원환자를 중심으로- (Changes in Hospital and Clinic Care Patterns Under the Medical Insurance System)

  • 서일
    • Journal of Preventive Medicine and Public Health
    • /
    • 제14권1호
    • /
    • pp.3-12
    • /
    • 1981
  • To identify the changes in professional care patterns after the introduction of medical insurance in Korea, professional care in hospitals and clinics of two succeeding years were compared. The hospitals and clinics selected for this study were those which located in Seoul city. Hospitals were classified into 3 categories: university hospital, general hospital and hospital. The diseases selected for this study were acute appendicitis and normal delivery. They were selected because their disease courses are considered to be fairly stable. The variables used for this study were length of stay, total hospital costs, costs of each components of cares. The information used for this study was obtained from the official forms requested by the medical facilities to the Korea Medical Insurance Corporation. The two periods studied were 3 months of each year from March 1st to May 31st in 1979 and 1980, The total number of normal delivery studied was 289 in 1979, 301 in 1980 respectively and the acute appendicitis was 92 and 111 respectively. In order to compare the quantity of medical care between 2 study periods the insurance price scores of 1979 were converted to prices of 1980. For statistical test of difference between 2 periods T-test and Welch's test were used. The result of the study were briefly summarized in below. 1. No significant difference was observed in the average length of stay of both disease between two study periods in all types of hospitals. 2. No significant difference was observed in the average total hospital costs of both diseases in all types of hospital, but in the private clinic the average clinic costs was rather decreased significantly in 1980. 3. More cost decrease were seen than cost increase in 1980 in all types of facilities, More cost changes by items were seen in acute appendicitis than in normal delivery between two study periods. The total hospital costs can be devided into 2 portions: charges for drug and material and for physician. In normal delivery, costs for physician's charges was significantly decreased in almost all the hospitals and costs for drug and material were not changed significantly in all the hospitals in 1980. In the university hospitals, however, the costs for drug and material were increased significantly in 1980. The cost decrease for physician's charge were mainly due to the decrease in the costs of laboratory test, treatment and physical therapy. The increase in the costs for the drug and material in the university hospitals was mainly due to the increase in the cost for drugs for oral administration and injection. 4. The proportion of components of medical care in the hospital has not been changed significantly, however, the cost for injection in normal delivery was characteristically increased in 1980 in all hospitals studied. In general the proportion of the costs for drug and material was tended to increase and the costs for physician was tended to decrease in 1980. The increase in the costs for drug and material were considered to be due to increase in the cost for drugs for oral administration and injection. The decrease in the costs for physician were due to decrease in the costs of laboratory test, treatment and physical therapy. Above mentioned changes in hospital and clinic care patterns are considered to be mostly influenced by the review criteria set by the K.I.C. for the assessment of the fee request made by clinics and hospitals.

  • PDF

격자 볼츠만법을 이용한 리튬이온전지의 활물질 혼합비에 대한 함침성의 영향 (Effect of Mixing Ratio of Active Material on the Wettability in Lithium-Ion Battery Using Lattice Boltzmann Method)

  • 전동협
    • 대한기계학회논문집B
    • /
    • 제40권1호
    • /
    • pp.47-53
    • /
    • 2016
  • 격자 볼츠만법을 이용하여 리튬이온전지의 전극 내 발생하는 전해액 함침 현상에 관하여 연구하였다. 최근 리튬이온전지는 용량 증가 및 에너지밀도 향상을 위하여 전극 설계시 활물질에 미세입자를 혼합하고 있어, 이로 인하여 전해액 함침성에 영향을 미치게 될 수 있다. 본 연구에서는 활물질 혼합율에 따른 전해액 분포와 포화도 변화를 알아보았다. 활물질 혼합비의 변화는 전극 내 전해액 함침 메커니즘에 영향을 주어, 전해액 함침속도와 함침도가 변화함을 확인하였다.

구조변화에 따른 압전형 마이크로스피커의 모의해석 (Simulation Results of Piezoelectric Microspeakers due to Structural Changes)

  • 정경식;어순철;조희찬;이승환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.327-327
    • /
    • 2007
  • This paper reports the simulation results of piezoelectric microspeakers due to structural changes(diaphragm materials, corrugation width and electrode shapes). When we compared the dependence of diaphragm material properties, the microspeaker with LTO(Low Temperature Oxide) diaphragm shows higher deflection than that of silicon nitride diaphragm, even though the resonant frequencies are almost same in both cases. In case of circular-electrode microspeaker, the deflection of diaphragm is about $16\;{\mu}m$ at 20 V, and it decreases as the corrugation width is decreased. However, the deflection of diaphragm with the square-electrode reveals almost twice times higher value at the same applied voltage than the circular one, and it increases as the corrugation depths are decreased from $30\;{\mu}m\;to\;10\;{\mu}m$. The first resonant frequency of microspeakers present about 1.8 kHz in circular-electrode and 1.2 kHz in square-electrode, respectively.

  • PDF

LVDT의 출력 특성에 미치는 공정 및 재료 변수의 영향에 관한 유한요소해석 (Finite Element Analysis of the Effects of Process and Material Parameters on the LVDT Output Characteristics)

  • 양영수;배강열
    • 한국기계가공학회지
    • /
    • 제20권9호
    • /
    • pp.11-19
    • /
    • 2021
  • Linear variable differential transformer (LVDT) is a displacement sensor and is commonly used owing to its wide measurement range, excellent linearity, high sensitivity, and precision. To improve the output characteristics of LVDT, a few studies have been conducted to analyze the output using a theoretical method or a finite element method. However, the material properties of the core and the electromagnetic force acting on the core were not considered in the previous studies. In this study, a finite element analysis model was proposed considering the characteristics of the LVDT composed of coils, core, magnetic shell and electric circuit, and the core displacement. Using the proposed model, changes in sensitivity and linear region of LVDT according to changes in process and material parameters were analyzed. The outputs of the LVDT model were compared with those of the theoretical analysis, and then, the proposed analysis model was validated. When the electrical conductivity of the core was high and the relative magnetic permeability was low, the decrease in sensitivity was large. Additionally, an increase in the frequency of the power led to further decrease in sensitivity. The electromagnetic force applied on the core increased as the voltage increased, the frequency decreased, and the core displacement increased.

Translucency changes of direct esthetic restorative materials after curing, aging and treatment

  • Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.239-245
    • /
    • 2016
  • The purpose of this article was to review the changes in translucency of direct esthetic restorative materials after curing, aging and treatment. As a criterion for the evaluation of clinical translucency changes, visual perceptibility threshold in translucency parameter difference (${\Delta}TP$) of 2 was used. Translucency changes after curing were perceivable depending on experimental methods and products (largest ${\Delta}TP$ in resin composites = 15.9). Translucency changes after aging were reported as either relatively stable or showed perceivable changes by aging protocols (largest ${\Delta}TP$ in resin composites = -3.8). Translucency changes after curing, aging and treatment were perceivable in several products and experimental methods. Therefore, shade matching of direct esthetic materials should be performed considering these instabilities of translucency in direct esthetic materials.