• Title/Summary/Keyword: Matching Coefficient

Search Result 266, Processing Time 0.023 seconds

Comparison the quantification method of PCBs in waste transformer oils (절연유 중 폴리염화비페닐류의 정량법 비교)

  • Kim, Kyeo-Keun
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.206-215
    • /
    • 2005
  • Polychlorinated biphenyls (PCBs) were commercially produced as complex mixtures beginning in 1929. The PCBs manufactured commercially are known by a variety of trade names including; Aroclor (USA), Phenoclor (France), Kaneclor (Japan), Sovol (USSR) and so on. PCBs are a class of 209 congeners that were widely used in a wide variety of applications, including dielectric fluid in transformers and large capacitors; heat transfer fluids; hydraulic fluids; lubricating and cutting oils; and as additives in pesticides, paints, adhesives, sealants, and plastics. The quantification methods of peak matching and coefficient comparison were compared using the Aroclor 1242, 1248, 1254, 1260 standards. Also, six transformer oils were analyzed as a main source of polychlorinated biphenyls (PCBs) emission into the environment. The transformer oils contained the pure and mixed of Aroclor 1242, Aroclor 1254, and Aroclor 1260. The analytical results using two quantification methods showed the little difference between the measured results.

Music Identification Using Pitch Histogram and MFCC-VQ Dynamic Pattern (피치 히스토그램과 MFCC-VQ 동적 패턴을 사용한 음악 검색)

  • Park Chuleui;Park Mansoo;Kim Sungtak;Kim Hoirin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.178-185
    • /
    • 2005
  • This paper presents a new music identification method using probabilistic and dynamic characteristics of melody. The propo3ed method uses pitch and MFCC parameters as feature vectors for the characteristics of music notes and represents melody pattern by pitch histogram and temporal sequence of codeword indices. We also propose a new pattern matching method for the hybrid method. We have tested the proposed algorithm in small (drama OST) and broad (1.005 popular songs) search spaces. The experimental results on search areas of OST and 1,005 popular songs showed better performance of the proposed method over conventional methods. We achieved the performance improvement of average $9.9\%$ and $10.2\%$ in error reduction rate on each search area.

Standardization of the Comprehensive Learning Test-Reading for the Diagnosis of Dyslexia in Korean Children and Adolescents (국내 아동 및 청소년 난독증 진단을 위한 종합학습능력평가도구-읽기의 표준화 연구)

  • Yoo, Hanik K.;Jung, Jaesuk;Lee, Eun Kyung;Kang, Sung Hee;Park, Eun Hee;Choi, InWook
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.27 no.2
    • /
    • pp.109-118
    • /
    • 2016
  • Objectives: The aim of this study was to develop the computerized Comprehensive Learning Test-Reading (CLT-R) to evaluate the cognitive processes and achievements related to their basic reading ability and identify dyslexia in children and adolescents in South Korea. We also obtained the normative data and evaluated the reliability and validity of the test. Methods: We developed the CLT-R, including the word attack/nonword decoding, paragraph reading, sound blending, nonword repetition, rapid automatized naming, letter-sound matching, visual attention, orthography awareness, and digit span tests, for the purpose of diagnosing dyslexia. We investigated the reliability and validity of the tests and gathered the normative data from 399 subjects (male 48.9%), aged 5-14 years, from the last grade in kindergarten to middle school, dwelling in Seoul and Gyeonggi Province, South Korea. Results: No statistical differences were observed between the means of the tests and retests of the CAT. The mean of the correlation coefficient of the test-retest scores was 0.85. According to the construct validity test calculated by principal constant analysis using the oblique rotation method, 4 factors explained 70.0% of the cumulative variances. In addition, the normative data were obtained for all of the CLT-R subtests. Conclusion: The computerized CLT-R can be used as a reliable and valid tool to evaluate the reading achievement and reading related cognitive process in Korean children and adolescents in schools, clinics, and research institutes.

Design of a Double-Faced Window Printed Antenna for Aircraft Applications (항공기용 양면 인쇄형 글래스 안테나 설계)

  • Byun, Gang-Il;Han, Wone-Keun;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.131-139
    • /
    • 2011
  • In this paper, we propose a double-faced window printed antenna for aircraft applications. The proposed antenna structure consists of a feeding line and a multi-loop radiator located on different sides of the window to use the limited given-area effectively. The proposed antenna is optimized by the genetic algorithm in conjunction with the FEKO EM simulator. The optimized antenna is built and installed on a 1/10 sized KUH-Surion mock-up and antenna performances such as the reflection coefficient and the radiation patterns are measured. The optimized antenna shows a half power matching bandwidth of about 33 % at 60 MHz and an average bore-sight gain of about -3.49 dBi. To verify the reception capability of the optimized antenna, we simulated the received power according to a flight scenario. The result confirms that the optimized antenna shows a minimum received power level above -60 dBm at a range of 200 km, which is similar to the pole antenna that is currently used as a FM voice antenna for KUH-Surion.

A Study on the Long-term Settlements Characterlistics and Settlement Prediction of Soft Ground in West-South Region (서남권 연약지반의 장기침하 특성과 침하예측에 관한 연구)

  • Lee, Seungho;Jung, Jisu;Ji, Younghwan;Kim, Sungmun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.4
    • /
    • pp.77-91
    • /
    • 2012
  • Recently, construction of housing sites, complexes, roads, ports and airports is increasing for high-intensity use of the country and balanced development between regions. Presently, constructions are being conducted at soft ground. Consequently, engineering problems as long-term settlement of the ground, differential settlement, local structural damage have been reported consistently at construction site. In particular, long-term subsidence of the ground as various constructions and loads by the load will necessarily occur in the soft ground of west-south coast and inland coast. Therefore, in this study, regional proper analysis methods of the Hyperbole method, Hosino method, $\sqrt{S}$ method, Asaoka method etc as existing long-term settlement prediction methods have been examined and a study on new prediction method was conducted through deduction of a generalized equation. Correlation coefficients of soil properties and construction conditions has been analyzed and a matching coefficient of long-term settlement characteristics has been deducted. Comparison and analysis of monitoring data and numerical analysis results of 16 local area have been conducted.

Manufacture of a single gate MESFET mixer at PCS frequency band (PCS 주파수 대역 단일 게이트 MESFET 혼합기의 제작)

  • 이성용;임인성;한상철;류정기;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.1
    • /
    • pp.25-33
    • /
    • 1998
  • In this paper, we describe a single-gate MESFET mixer at PCS(Personal Communication Service) frequency band. The PCS frequency band is 1965~2025 MHz in FR and 140 MHz in IF irrespectly. The design of the mixer was executed by microwave simulator, EEsof Libra. The matching network is consisted of rectangular inductor, MIM capacitor and open stub. The ma- nufacture work was accomplished by the micro-pen and wedge-bonder. The mixer showed $6.69\pm0.65$ dB of conversion gain, $-14.9\pm3.5$dB of RF reflection coefficient and 57.83 dB of LO/IF isolation at 10 dBm of LO power when LO frequency is 1855 MHz. When this mixer is used at PCS terminal, IF-amplifier which compensates the conversion loss of diode mixer may be omitted.

  • PDF

Compact 1×2 and 2×2 Dual Polarized Series-Fed Antenna Array for X-Band Airborne Synthetic Aperture Radar Applications

  • Kothapudi, Venkata Kishore;Kumar, Vijay
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.117-128
    • /
    • 2018
  • In this paper, compact linear dual polarized series-fed $1{\times}2$ linear and $2{\times}2$ planar arrays antennas for airborne SAR applications are proposed. The proposed antenna design consists of a square radiating patch that is placed on top of the substrate, a quarter wave transformer and $50-{\Omega}$ matched transformer. Matching between a radiating patch and the $50-{\Omega}$ microstrip line is accomplished through a direct coupled-feed technique with the help of an impedance inverter (${\lambda}/4$ impedance transformer) placed at both horizontal and vertical planes, in the case of the $2{\times}2$ planar array. The overall size for the prototype-1 and prototype-2 fabricated antennas are $1.9305{\times}0.9652{\times}0.05106{{\lambda}_0}^3$ and $1.9305{\times}1.9305{\times}0.05106{{\lambda}_0}^3$, respectively. The fabricated structure has been tested, and the experimental results are similar to the simulated ones. The CST MWS simulated and vector network analyzer measured reflection coefficient ($S_{11}$) results were compared, and they indicate that the proposed antenna prototype-1 yields the impedance bandwidth >140 MHz (9.56-9.72 GHz) defined by $S_{11}$<-10 dB with 1.43%, and $S_{21}$<-25 dB in the case of prototype-2 (9.58-9.74 GHz, $S_{11}$< -10 dB) >140 MHz for all the individual ports. The surface currents and the E- and H-field distributions were studied for a better understanding of the polarization mechanism. The measured results of the proposed dual polarized antenna were in accordance with the simulated analysis and showed good performance of the S-parameters and radiation patterns (co-pol and cross-pol), gain, efficiency, front-to-back ratio, half-power beam width) at the resonant frequency. With these features and its compact size, the proposed antenna will be suitable for X-band airborne synthetic aperture radar applications.

CPW-fed Wideband Loop Antenna for Indoor Digital TV Applications (실내 디지털 TV용 CPW-급전 광대역 루프 안테나)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1492-1497
    • /
    • 2017
  • In this paper, a design method for a CPW-fed wideband loop antenna for indoor digital TV applications is studied. The proposed loop antenna consists of a square loop and two circular sectors which connect the loop with central feed points, and the CPW feed line is inserted in the lower circular sector. The CPW feed line is designed to match with the 75 ohm port impedance for DTV applications, and the ground slots are etched in order to improve the impedance matching in the middle frequency region. The effects of the gap between the circular sectors and the location and dimension of the ground slots on the input reflection coefficient and gain characteristics are examined to obtain the optimal design parameters. The optimized antenna is fabricated on FR4 substrate, and the experiment results show that it operates in the frequency band of 463-1,280 MHz for a VSWR < 2, which assures the operation in the DTV band.

Stream flow estimation in small to large size streams using Sentinel-1 Synthetic Aperture Radar (SAR) data in Han River Basin, Korea

  • Ahmad, Waqas;Kim, Dongkyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.152-152
    • /
    • 2019
  • This study demonstrates a novel approach of remotely sensed estimates of stream flow at fifteen hydrological station in the Han River Basin, Korea. Multi-temporal data of the European Space Agency's Sentinel-1 SAR satellite from 19 January, 2015 to 25 August, 2018 is used to develop and validate the flow estimation model for each station. The flow estimation model is based on a power law relationship established between the remotely sensed surface area of water at a selected reach of the stream and the observed discharge. The satellite images were pre-processed for thermal noise, radiometric, speckle and terrain correction. The difference in SAR image brightness caused by the differences in SAR satellite look angle and atmospheric condition are corrected using the histogram matching technique. Selective area filtering is applied to identify the extent of the selected stream reach where the change in water surface area is highly sensitive to the change in stream discharge. Following this, an iterative procedure called the Optimum Threshold Classification Algorithm (OTC) is applied to the multi-temporal selective areas to extract a series of water surface areas. It is observed that the extracted water surface area and the stream discharge are related by the power law equation. A strong correlation coefficient ranging from 0.68 to 0.98 (mean=0.89) was observed for thirteen hydrological stations, while at two stations the relationship was highly affected by the hydraulic structures such as dam. It is further identified that the availability of remotely sensed data for a range of discharge conditions and the geometric properties of the selected stream reach such as the stream width and side slope influence the accuracy of the flow estimation model.

  • PDF

A Study on the Absorption Performance of a Perforated Panel type of Resonator (다공패널형 공명기의 흡음성능에 관한 연구)

  • Song, Hwayoung;Yang, Yoonsang;Lee, Donghoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.224-231
    • /
    • 2016
  • When aiming to reduce the low frequency noise of a subway guest room through sound absorbing treatment methods inside the wall of a tunnel the resonator is often more effective than a porous sound absorbing material. Therefore, the perforated panel type resonator embedded with a perforated panel is proposed. The perforated panel is installed in the neck, which is then extended into the resonator cavity so that it can ensure useful volume. The absorption performance of the perforated panel type of resonator is obtained by acoustic analysis and experiment. The analytical results are in good agreement with the experimental results. In the case of multiple perforated panel type resonators, as the number of perforated panels increase, the 1st resonance frequency is moved to a low frequency band and sound absorption bandwidth is extended on the whole. In order to obtain excellent absorption performance, the impedance matching between multi-panels should be considered. When the perforated panel in the resonator is combined with a porous material, the absorption performance is highly enhanced in the anti-resonance and high frequency range. In case of the resonator inserted with perforated panels of 2, the 2nd resonance frequency is shifted to a low frequency band in proportion to the distance between perforated panels.