• 제목/요약/키워드: Mat Foundation

검색결과 131건 처리시간 0.032초

깊게 파인 온통기초가 구조물의 수평방향 설계스펙트럼에 미치는 영향 (Effect of a Sunken Mat Foundation on the Horizontal Design Spectrum of a Structure)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제25권4호
    • /
    • pp.169-177
    • /
    • 2021
  • In this paper, horizontal seismic responses of a structure built on a sunken mat foundation were compared with those built on a solid embedded mat foundation to investigate the effect of a sunken mat foundation on the horizontal response of a structure. Seismic analyses of a structure laid on the embedded mat foundation were performed by utilizing a pseudo-3D finite element software of P3DASS. Three bedrock earthquake records downloaded from the Pacific Earthquake Engineering Research Center database were scaled to reproduce weak-moderate earthquakes. Weak, medium, and stiff soil layers were considered for the seismic analyses of the structure-foundation-soil system. Parametric studies were performed for foundation radius, foundation embedment depth, and shear wave velocity of a soil layer to investigate their effect on the seismic response spectrum. The study result showed that the design spectrum of a structure built on a sunken mat foundation was similar to that with a solid embedded mat foundation showing a slight difference due to almost the same seismic base motion beneath both embedded foundations.

공동주택 지하 주차장 기초형식 선정방법에 관한 연구 (A Study on the Selection Method of Foundation Type in the Underground Parking Lot of Apartments)

  • 임남기;이영도;배용환
    • 한국건축시공학회지
    • /
    • 제4권3호
    • /
    • pp.109-116
    • /
    • 2004
  • Normally easy task of plat in urban architecture is that using underground full of activities for increase building site efficiency. Especially for using underground space for the parking lot. Also utilize underground is more increase for fulfill requirement in modern society considered with environmental friendly architecture. The primary objective of this study is to apply analyzed formal foundation type for selecting the optimum type of parking lots considered with structural stability, economical efficiency, construction efficiency, construction duration. This study aim to on criteria decided through the questionaries for the selection considered with in the scale of second stories parking lots underground, parking volume is 80 and reinforced concrete structure. The bearing capacity is 6~8m and downward from surface, healthy ground bearing capacity is 40 t/m2. This study comparative analysis and discuss economical efficiency, construction efficiency, construction duration based constructivist stability which applied Single foundation, Mat foundation, Drop Mat foundation. The result of this study is as follows: First, the result of economical efficiency is that on the basis of single foundation, Drop Mat foundation is 1.88, Mat foundation 2.04 as a comparative analysis on the basis of total construction cost included material cost, labor coast and machinery cost. Second, the result of construction efficiency order is single foundation, Drop Mat foundation, Mat foundation as a comparative analysis on the based connected characteristics. Third, the result of construction duration is that on the basis of Mat Foundation, Drop Mat foundation is 1.33, single foundation is 1.87 as a comparative analysis Critical Path. Forth, Each foundational type characteristics order through the matrix method is that overall each formal type of foundation contraries at economical efficiency and construction efficiency, construction duration. Also expect contradiction between engineers and owners due to engineer pursuit construction duration and ewer to begin with economical efficiency. Fifth, The selection of suitable foundation formal type needs that based consider project characteristic and field condition as according to above result of a comparative analysis. As a result, a comparative analysis economical efficiency, construction efficiency, construction duration of Mat foundation, Drop Mat foundation, single foundation with 3Bay reinforced structure underground parking lots on the healthy ground.

Variability of subgrade reaction modulus on flexible mat foundation

  • Jeong, Sangseom;Park, Jongjeon;Hong, Moonhyun;Lee, Jaehwan
    • Geomechanics and Engineering
    • /
    • 제13권5호
    • /
    • pp.757-774
    • /
    • 2017
  • The subgrade reaction modulus of a large mat foundation was investigated by using a numerical analysis and a field case study. The emphasis was on quantifying the appropriate method for determining the subgrade reaction modulus for the design of a flexible mat foundation. A series of 3D non-linear FE analyses are conducted with special attention given to the subgrade reaction modulus under various conditions, such as the mat width, mat shape, mat thickness, and soil condition. It is shown that the distribution of the subgrade reaction modulus is non-uniform and that the modulus of subgrade reaction at both the corners and edges should be stiffer than that at the center. Based on the results obtained, a simple modification factor for the subgrade reaction modulus is proposed depending on the relative positions within the foundation in weathered soil and rocks.

매트기초의 온도균열에 미치는 시공조건의 영향에 관한 연구 (A Study on the Effect of the Construction Conditions on a Thermal Crack of Mat Foundation)

  • 이도범;김효락;최일호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.1-4
    • /
    • 2003
  • Recently, a structure has been larger and higher under the improvement of construction technique. So, a concrete constructions that a mat foundation thickness of structure is over 80cm have been many. Also, because of the reason high strength concrete, the matter of thermal crack have become an important task to be solved absolutely. In a cause a thermal crack occurrence, there used, mixture of concrete, construction and so forth. In this study, we executed temperature and stress analysis of mat foundation to know the effect the construction condition a thermal crack of mat foundation. And we evaluated quantitatively about the occurrence possibility of thermal crack using the hydration heat analysis program. By using of this analysis technique, will can control skilfully the quality of a mat foundation in advance.

  • PDF

매트기초의 온도균열에 미치는 시공조건의 영향에 관한 연구 (A Study on the Effect of the Construction Conditions on a Thermal Crack of Mat Foundation)

  • 이도범;김효락;최일호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.1-4
    • /
    • 2003
  • Recently, a structure has been larger and higher under the improvement of construction technique. So, a mass concrete constructions that a mat foundation thickness of structure is over 80cm have been many. Also, because of the reason of high strength of concrete, the matter of thermal crack have become an important task to be solved absolutely. tn a cause of a thermal crack occurrence, there are material used, mixture of concrete, construction condition and so forth. In this study, we executed temperature and stress analysis of mat foundation to know the effect of the construction condition on a thermal crack of mat foundation. And we evaluated quantitatively about the occurrence possibility of thermal crack using the hydration heat analysis program. By using of this analysis technique, we will can control skilfully the quality of a mat foundation in advance.

  • PDF

매트기초의 온도균열 제어에 관한 연구 (A Study on the Control of Thermal Crack of the Mat Foundation)

  • 이도범;김효락;박지훈;최일호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.305-308
    • /
    • 2003
  • Recently, a structure has been large and high under the improvement of construction technique. So, mass concrete constructions that a mat foundation thickness of structure is over 80cm have been many. Also, in the reason of high strength of concrete, a matter of thermal crack became an important task to be solved. In this study, we executed temperature and stress analysis of mat foundation. And we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis program. Because of this analysis technique, we could control skilfully the quality of mat foundation in a construction.

  • PDF

태양 복사열이 콘크리트 매트기초의 내부 온도분포에 미치는 영향에 관한 해석적 연구 (Analysis of the Effect of Solar Radiation on Internal Temperature Distribution in Concrete Mat Foundation)

  • 송정현;이창준
    • 한국건축시공학회지
    • /
    • 제17권1호
    • /
    • pp.63-72
    • /
    • 2017
  • 태양 복사가 콘크리트 매트기초 내부 온도 분포에 미치는 영향에 대한 해석적 연구를 수행하였다. 태양복사량 산정을 위해 Zhang and Huang 모델을 사용하였다. 열전달 방정식과 Galerkin 방법을 이용하여 1차원 열전달 유한 요소 정식화를 수행하였으며, MATLAB을 사용하여 유한요소 해석코드를 작성하였다. 작성된 해석코드를 바탕으로 태양복사를 고려한 콘크리트 매트기초의 수화열 해석을 수행하였다. 해석결과, 태양복사가 매트기초 내부-표면부 최대온도차를 줄여주는 효과를 보임을 확인하였다. 또한 이러한 효과는 하절기 타설시, 콘크리트 초기온도가 클수록, 그리고 매트기초의 두께가 두꺼울수록 더욱 뚜렷해짐을 확인 하였다. 본 연구는 콘크리트 매트기초의 수화열 해석시 해석결과의 과대평가를 피하기 위해서 태양 복사의 영향을 고려해야 함을 권고한다.

초고층 건물의 전면기초(MAT기초) 해석 및 설계 (ANALYSIS AND DESIGN OF MAT FOUNDATION FOR HIGH-RISE BUILDINGS)

  • 홍원기;황대진;권장혁
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.94-110
    • /
    • 1994
  • Types of foundation of high rise buildings are primarily determined by loads transmitted from super structure, soil bearing capacity and available construction technology. The usd of deep foundation cannot be justified due to the fact that rock of enough bearing capacity is not found down until 90 ~ 100m. When a concentration of high soil pressure must be distributed over the entire building area, when small soft soil areas must be bridged, and when compressible strata are located at a shallow depth, mat foundation may be useful in order to have settlement and differential settlement of variable soils be minimized. The concept of mat foundation will also demonstrate some difficulities of applications if the load bearing demand directly carried down to the load -bearing strata exceeds the load -bearing capacity. This paper introduces both the analysis and design of mat type foundation for high rise buildings as well as the methodology of modelling of the soil foundation, especially, engineered to redistribute the stress exceeding the soil bearing capadity. This process will result in the wid spread of stresses over the entire building foundation.

  • PDF

Performance of under foundation shock mat in reduction of railway-induced vibrations

  • Sadeghi, Javad;Haghighi, Ehsan;Esmaeili, Morteza
    • Structural Engineering and Mechanics
    • /
    • 제78권4호
    • /
    • pp.425-437
    • /
    • 2021
  • Under foundation shock mats have been used in the current practice in order to reduce/damp vibrations received by buildings through the surrounding environment. Although some investigations have been made on under foundation shock mats performance, their effectiveness in the reduction of railway induced-vibrations has not been fully studied, particularly with the consideration of underneath soil media. In this regard, this research is aimed at investigating performance of shock mat used beneath building foundation for reduction of railway induced-vibrations, taking into account soil-structure interaction. For this purpose, a 2D finite/infinite element model of a building and its surrounding soil media was developed. It includes an elastic soil media, a railway embankment, a shock mat, and the building. The model results were validated using an analytical solution reported in the literature. The performance of shock mats was examined by an extensive parametric analysis on the soil type, bedding modulus of shock mat and dominant excitation frequency. The results obtained indicated that although the shock mat can substantially reduce the building vibrations, its performance is significantly influenced by its underneath soil media. The softer the soil, the lower the shock mat efficiency. Also, as the train excitation frequency increases, a better performance of shock-mats is observed. A simplified model/method was developed for prediction of shock mat effectiveness in reduction of railway-induced vibrations, making use of the results obtained.

Gravel Mat로 보강된 말뚝지지 전면기초의 실내모형실험 (Laboratory Test of Piled-Raft Foundation Improved by Gravel Mat)

  • 서영교;이정훈
    • 한국해양공학회지
    • /
    • 제25권2호
    • /
    • pp.47-54
    • /
    • 2011
  • A piled raft foundation is one of the systems used to reduce the settlement of structures. However, the general design method for a piled raft foundation system assumes that the piles only support external loads, which exclude the bearing capacity of the raft itself. In this study, an experimental model test was performed to evaluate the raft capacity for the external load on the sand. Additionally, a part of the sandy ground under the raft was replaced with a gravel mat to reinforce the piled raft foundation system and increase the bearing capacity. Then, parametric studies of the reinforced ground were performed to determine the displacement and load-sharing ratio of the piled raft foundation system.