• Title/Summary/Keyword: Master file

검색결과 63건 처리시간 0.03초

Water loss Control in DMA Monitoring System Used Wireless Technology

  • Malithong, P.;Gulphanich, S.;Suesut, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.773-777
    • /
    • 2005
  • This article is about using information technology to apply with water loss inspection system in District Metering Area (DMA). Inspector can check Flow rate and Minimum Night Flow; NMF via Smart Phone or PDA include sending SMS Alert in case the Pressure, Flow rate and NMF is over the range of controlling. This will be used as equipment to implement water loss in international proactive and can keep on water loss reduction more efficiency. The system consists of Data Logger which collects data of Flow rate from DMA Master Meter. PC is Wap Server which dial via modem in order to get data through FTP Protocal that will convert text file to Microsoft Access Database. Wappage will use xhtml language to show database on Wapbrowser and can show the result on Smart Phone or PDA by graph and table for system analysis.

  • PDF

흉상환조가공 전용 CAM 시스템 개발 (Development of a Dedicated CAM System for Human Bust Machining)

  • 정회민;박준철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2001
  • We have developed a prototype dedicated CAM system for machining a human bust that is not a relief. The input is STL file format, and the output is NC-codes for machining on a 3-axis general purpose CNC milling machine with an index table attached. Main modules are STL import, STL transformation, modeling jig/fixture, master model generation, and calculation of machining area. System architecture is proposed and main modules are briefly described. We adopted the angle between tool-axis and the surface normal vector to calculate machining area, and tested at several degrees.

  • PDF

그래픽을 이용한 대화식 교육용 전력조류계산 소프트웨어 개발 (Development of Interactive Graphical Software for Power Flow Education)

  • 이욱화;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.39-41
    • /
    • 1993
  • This paper presents the development of interactive graphical software for the educational purpose of power flow(PF) calculation. The developed software is specially designated to give a beginner the interest on PF problem as well as to increase the understanding of it with ease. the software developed in this paper is basically composed of the pull-down menu driver, in which various functions, such as Program Master, Data File Management, Case Study Option, PF Run and View Output, are prepared to handle the software easily and thus to be familiar with power flow calculation. A special design is also considered for interactive operation of the software, wi th which user can interrupt the computation process of PF to control the convergency of PF algorithm, With this function begineer can acquire the understanding of convergency characteristics and numerical sensitivity of PF algorithm as well as basic concept of its computation logic. Futhermore, various graphic illustrations is also provided to review and compare the computation results on monitor.

  • PDF

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography

  • Kim, Dong-Yeon;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.239-243
    • /
    • 2017
  • PURPOSE. The purpose of this study is to compare single and three-unit metal frameworks that are produced by micro-stereolithography. MATERIALS AND METHODS. Silicone impressions of a selected molar and a premolar were used to make master abutments that were scanned into a stereolithography file. The file was processed with computer aided design software to create single and three-unit designs from which resin frameworks were created using micro-stereolithography. These resin frameworks were subjected to investment, burnout, and casting to fabricate single and three-unit metal ones that were measured under a digital microscope by using the silicone replica technique. The measurements were verified by means of the Mann-Whitney U test (${\alpha}=.05$). RESULTS. The marginal gap was $101.9{\pm}53.4{\mu}m$ for SM group and $104.3{\pm}62.9{\mu}m$ for TUM group. The measurement of non-pontics in a single metal framework was $93.6{\pm}43.9{\mu}m$, and that of non-pontics in a three-unit metal framework was $64.9{\pm}46.5{\mu}m$. The dimension of pontics in a single metal framework was $110.2{\pm}61.4{\mu}m$, and that of pontics in a three-unit metal framework was $143.7{\pm}51.8{\mu}m$. CONCLUSION. The marginal gap was smaller for the single metal framework than for the three-unit one, which requires further improvement before it can be used for clinical purposes.

혐기성세균모델을 이용한 봉함제(Sealer)의 미세누출에 관한 연구 (LEAKAGE EVALUATION OF SEVERAL SEALERS USING ANAEROBIC BACTERIAL LEAKAGE MODEL)

  • 배용규;오태석;윤수한
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.235-242
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the sealing ability of three sealers(Sealapex, Pulp canal sealer, AH26) used with continuous wave method using an anaerobic bacterial leakage model. 53 extracted human teeth with straight and single canals were prepared with crown-down pressureless technique using .04, .06 taper Profile(Maillefer, Swiss). Master apical file was maintained as #35 K-file. All canals of the experimental teeth were obturated with continuous wave method using System B(Analytic technology, U.S.A.) The teeth were randomly divided into three experimental groups of 15 and two control groups of 4. Experimental group 1 was obturated with Sealapex and group 2 with Pulp canal sealer, and group 3 with AH26. A dual chamber anaerobic bacterial leakage model was assembled. Brain heart infusion with yeast extract, hemin, menadion, and the chromogenic indicator bromocresol purple was used as the culture broth for Fusobacterium nucleatum(VPI 10197), The specimens were incubated in anaerobic chamber at $37^{\circ}C$ and were observed every 2 to 3 clays, The coronal leakage was evaluated through the color change of culture broth in lower chamber for 60 days. The results were as follows: 1. The incidence of bacterial leakage in group 1 (Sealapex group was 80%, 53% in group 2 (Pulp canal sealer), 27% in group 3 (AH26). 2. There were statistically significant differences in leakage scores between group 1 and group 2, and between group 1 and group 3, respectively. (P<0.05) 3. There was no significantly difference in leakage score between group 2 and group 3. (P>0 05)

  • PDF

A micro-computed tomographic study of remaining filling materials of two bioceramic sealers and epoxy resin sealer after retreatment

  • Kim, KyungJae;Kim, Da Vin;Kim, Sin-Young;Yang, SungEun
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.18.1-18.9
    • /
    • 2019
  • Objective: This study evaluated the presence of residual root canal filling material after retreatment using micro-computed tomography (micro-CT). Materials and Methods: Extracted human teeth (single- and double-rooted, n = 21/each; C-shaped, n = 15) were prepared with ProFile and randomly assigned to three subgroups for obturation with gutta-percha and three different sealers (EndoSeal MTA, EndoSequence BC sealer, and AH Plus). After 10 days, the filling material was removed and the root canals were instrumented one size up from the previous master apical file size. The teeth were scanned using micro-CT before and after retreatment. The percentage of remaining filling material after retreatment was calculated at the coronal, middle, and apical thirds. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni post hoc correction. Results: The tested sealers showed no significant differences in the percentage of remaining filling material in single- and double-rooted teeth, although EndoSeal MTA showed the highest value in C-shaped roots (p < 0.05). The percentage of remaining filling material of AH Plus and EndoSeal MTA was significantly higher in C-shaped roots than in single- or double-roots (p < 0.05), while that of BC sealer was similar across all root types. EndoSeal MTA showed the highest values at the apical thirds of single- and double-roots (p < 0.05); otherwise, no significant differences were observed among the coronal, middle, and apical thirds. Conclusions: Within the limitations of this study, a large amount of EndoSeal MTA remained after retreatment, especially in C-shaped root canals.

플러거 삽입깊이가 근관실러의 치근단 정출에 미치는 영향 (Influence of plugger penetration depth on the apical extrusion of root canal sealer in Continuous Wave of Condensation Technique)

  • 소호영;이영미;김광근;김기옥;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.439-445
    • /
    • 2004
  • Continuous Wave 가압법으로 근관충전시 플러거 삽입 깊이에 따른 근관실러의 치근단 정출을 평가하고자 직선형의 단근관 및 15번 크기의 치근단공을 가지는 발거된 40개의 치아에서 0.06 경사도 40번 크기가 되게 니켈-티타늄 전동화일인 $ProFile^{\circledR}$로 근관을 형성하고 플러거 삽입깊이를 근단 3, 5 또는 7 mm로 하여 System $B^{TM}$를 이용한 Continuous Wave 가압법 및 측방가압법으로 근관을 충전하였다. 치근단으로 정출된 근관실러의 무게를 측정하여 일원변량분석법과 Duncan's Multiple Range Test로 통계분석하였다. 플러거 삽입깊이 3 mm 또는 5 mm의 Continuous Wave 가압 충전군은 삽입깊이 7 mm 가압충전 군 및 측방가압 충전군에 비해 유의하게 많은 근관실러의 치근단 정출을 나타내었다 (p < 0.05). 그러나 플러거 삽입깊이 3 mm군과 5 mm군 사이 및 플러거 삽입깊이 7 mm Continuous Wave 가압군과 측방가압 군 사이에는 유의한 차이가 나타나지 않았다 (p > 0.05). 본 연구의 결과로 보아 Continuous Wave 가압법으로 근관충전시에는 플러거 삽입깊이가 깊을수록 근관실러의 치근단 정출이 많음을 알 수 있다.

UDC의 적용분야에 관한 연구 (An Analysis of the Applicable Fields of UDC)

  • 이창수
    • 한국도서관정보학회지
    • /
    • 제35권4호
    • /
    • pp.1-21
    • /
    • 2004
  • 이 연구는 UDC의 최근동향을 보다 체계적으로 이해하는데 도움이 되고자 UDC의 역사적 배경과 그 분류표의 유지관리 및 개정, 그리고 UDC가 최근에 어떻게 적용되고 있는지에 대하여 살펴보았다. UDC는 1905년이래 발전을 거듭하여, 현재 UDCC가 관리를 하며 전자적으로 이용가능 한 MRF를 매년 갱신함으로 써 최신성을 유지하고 있다. UDC는 기호의 생략정도에 따라 표준판, 확장판, 간략판으로 출판하고 있으며, 온라인 상에서도 UDC를 이용할 수 있다. UDC는 현재 서가배열, SDI 서비스, 서지의 주제별탐색, 교환언어로서 또는 인터넷상에서의 주제 게이트웨이와 메타데이터, 자동분류 등에 적용되고 있다.

  • PDF

포렌식 관점의 파티션 복구 기법에 관한 연구 (A research for partition recovery method in a forensic perspective)

  • 남궁재웅;홍일영;박정흠;이상진
    • 정보보호학회논문지
    • /
    • 제23권4호
    • /
    • pp.655-666
    • /
    • 2013
  • 저장장치의 용량이 점차 대형화됨에 따라 대부분의 사용자들은 데이터의 저장 및 관리의 편의를 위하여 저장장치를 논리적으로 여러 개의 파티션으로 나누어 사용한다. 따라서 인위적인 파티션 은닉이나 파티션 손상 등으로부터 안정적으로 파티션을 복구해내는 것은 디지털 포렌식 관점에서 매우 중요한 문제이다. 본 논문은 파티션이 은닉되어 있거나 파티션 영역의 손상으로 인하여 파티션이 구분되지 않는 경우, 각 파일 시스템의 특징을 이용하여 안정적이고 효율적인 분석이 가능한 파티션 복구 알고리즘에 대해 제시한다.