• 제목/요약/키워드: Mass transfer resistance

검색결과 133건 처리시간 0.029초

풍화된 암반에 근입된 현장타설말뚝의 하중전이 기구 (Load Transfer Mechanism of Drilled Shafts in Weathered Rock)

  • 권오성;조성민;정성준;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.57-64
    • /
    • 2005
  • Since the allowable bearing capacities of piles in weathered/fractured rock are mainly governed by settlement, the load-displacement behavior of the rock socketed pile should be well known. To predict pile head settlement at the design stage, the exact understanding of the load-transfer mechanisms is essential. Therefore, in this research, the load-transfer mechanisms of drilled shaft socketed into weathered rock was investigated. For that, 5 cast-in-place concrete piles with diameters of 1,000 mm were socketed into weathered gneiss. The static axial load tests and the load-transfer measurements were performed to examine the axial resistant behavior of the piles. A comprehensive field/laboratory testing program on weathered rock at the field test sites was also performed to describe the in situ rock mass conditions quantitatively. And then, the effect of rock mass condition on the load transfer mechanism was investigated. The side shear resistance of the pile in moderately weathered rock reached to yielding point at a few millimeter displacements, and after that, the rate of resistance increment dramatically decreased. However, that in the highly /completely weathered rock did not show the obvious yielding point, and gradually increased showing the hyperbolic pattern until with the relatively high displacement (>10 mm). The end bearing-displacement curves showed linear increase at least until with the base displacement of approximately 10 mm, regardless rock mass conditions.

  • PDF

삼축압축시험을 통한 암반에 근입된 현장타설말뚝의 선단 하중전이곡선 산정 (Evaluation of the q-w Curve on Rock-Socketed Drilled Shafts by Triaxial Compression Tests)

  • 김태형;김용민;정상섬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.455-465
    • /
    • 2008
  • In this study, the load distribution and deformation of rock-socketed drilled shafts subjected to axial load are investigated based on small scale model tests. In order to analyze the effects of major influencing factors of end bearing capacity, Hoek-cell triaxial tests were performed. From the test results, it was found that the initial slope of end bearing load transfer (q-w) curve was highly dependent on rock mass modulus and pile diameter, while the ultimate unit toe resistance ($q_{max}$) was influenced by rock mass modulus and the spacing of discontinuities. End bearing load transfer function of drilled shafts socketed in rock was proposed based on the Hoek-cell triaxial test results and the field loading tests which were performed on granite and gneiss in South Korea. Through the comparison with pile load tests, it is found that the load-transfer curve by the present study is in good agreement with the general trend observed by field loading tests, and thus represents a significant improvement in the prediction of load transfer of drilled shaft.

  • PDF

현장조건을 고려한 현장타설말뚝의 단위주면마찰력 (Side resistance of rock socketed drilled shafts considering in situ rock mass condition)

  • 사공명;백규호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.967-973
    • /
    • 2004
  • Rock socketed drilled shafts transfer significant portion of structural loads at the socketed part. Therefore, a proper design of side and base resistances of a shaft at the socket is a major concern for the geotechnical engineers. In this study, we modified the Hoek-Brown criterion to estimate side resistance of rock socketed drilled shafts. Earlier method to compute side resistance of a shaft is linear or power functions of intact rock masses. However, side resistance is mobilized like shearing which influenced by the mechanical properties of concrete and rock masses, adhesion of rock/concrete interface, roughness of rock socket. Therefore, a single coefficient or power of uniaxial compressive strength of intact rock cannot provide accurate values of side resistance in a wide range of the uniaxial compressive strength. A new approach proposed in this study can consider in situ rock mass condition (frequency or discontinuities, weathering condition), and rock types thus, it has a wider applicability than the earlier models.

  • PDF

Study on the growth of vapor bubble in devolatilization of polymers

  • Kim, Chongyoup
    • Korea-Australia Rheology Journal
    • /
    • 제11권3호
    • /
    • pp.247-253
    • /
    • 1999
  • The growth of a spherical vapor bubble contained in a large body of upper convected Maxwell fluid is theoretically analyzed under the devolatilization condition of polymer by using a Galerkin FEM in the Lagrangian frame. Using the finite element technique, a fully explicit numerical scheme is developed both for the calculation of pressure distribution and for the tracking of bubble surface. Oscillatory behavior in bubble radius is observed during growth and the oscillatory behavior is found to be due to the interaction of mass transfer resistance and elasticity. It is found that the elasticity of fluid accelerates the growth and removal of volatile component. It is also found that the bubble growth in the devolatilization of polymers is affected by both mass transfer resistance and viscoelasticity of fluids.

  • PDF

광합성 박테리아를 이용한 고성능 수소 생산 고정화 생물반응기의 개발(I) 고정화 연속 교반탱크 반응기에서의 수소 생산성 및 효율인자 평가 (Development of Bioreactors for Hydrogen-Producing Immobilized Photosynthetic Bacteria(I) : Evaluation of lmmobilized CSTR for Hydrogen Productivity and Effectiveness Factor)

  • 선용호;한정우
    • KSBB Journal
    • /
    • 제8권3호
    • /
    • pp.243-255
    • /
    • 1993
  • In this study, it was observed that hydrogen Productivity varied with stirrer speed, bead radius, input glucose concentration and dilution rate in a continuous stirred tank reactor in which immobilized R. rubrum KS-301 was used as a hydrogen-producing bacterium The mass transfer resistance due to cell immobilization was also studied. In order to estimate an effectiveness factor, Des of glucose was first obtained, which was subsequently represented by the correlation equation between Dos and Xb, As a result external mass transfer resistance could be neglected for stirrer speeds greater than 400rpn With bead radius increasing, the hydrogen productivity and internal effectiveness factor decreased. With input 91ucose concentration increasing, the hydrogen productivity and interval and external effectiveness factor increased. Although an Internal effectiveness factor was not affected, hydrogen productivity Increased with dilution rate increasing. An overall effectiveness factor remained nearly constant for the dilution rates investigate4 but increased with input 91ucose concentration increasing.

  • PDF

풍화된 암반에 근입된 현장타설말뚝의 하중전이기구 (Load Transfer Mechanism of Drilled Shafts in Weathered Rock)

  • 권오성;조성민;정성준;김명모
    • 한국지반공학회논문집
    • /
    • 제21권5호
    • /
    • pp.187-196
    • /
    • 2005
  • 풍화 및 절리가 발달한 암반에 근입된 말뚝의 허용지지력 결정에는 침하량이 매우 중요한 인자가 되며, 설계단계에서 말뚝두부의 침하량을 예측하기 위해서는 말뚝의 하중전이기구에 대한 이해가 필수적이다. 따라서 본 연구에서는 풍화된 암반에 근입된 현장타설말뚝의 하중전이기구에 대한 연구를 수행하였다. 이를 위해 직경 1m의 총 5본의 현장 타설말뚝을 풍화된 편마암 부지에 시공하구 재하시험 및 하중전이 계측을 수행하여 말뚝의 축방향 지지거동을 분석하였다. 암반상태를 정량적으로 파악하기 위하여 재하시험 부지의 암반에 대한 엄밀한 현장/실내시험을 수행하고, 이를 토대로 암반상태가 말뚝의 하중전이기구에 미치는 영향을 분석하였다. 하중전이 계측을 통해 얻은 주면하중전이 (f-w) 곡선은 풍화상태가 상대적으로 양호한(MW) 연암의 경우, 수 mm의 변위에서 항복에 도달하며, 이후 변위에 따른 지지하중의 증가율이 급격히 둔화되는 경향을 보였다. 반면 풍화암/풍화토에 근입된 말뚝의 f-w 곡선은 뚜렷한 항복점을 보이지 않으며, 상대적으로 큰(>15m) 변위까지 주면하중이 쌍곡선 형태로 증가하였다. 선단하중전이(q-w) 곡선은 암반상태에 관계없이 선단변위 (q-w)까지는 선형적인 거동을 보였다.

대기질 - 강우산성도 관계식의 개발 (Development of Relationship between Air Quality and Rain Acidity)

  • 구자공;유동준
    • 한국대기환경학회지
    • /
    • 제2권3호
    • /
    • pp.45-51
    • /
    • 1986
  • The simple and precise model for the estimation of rain acidity from the ambient air quality was developed using the theory of wet scrubber and the chemical equilibria of $SO_2, CO_2, and H_2O$ system. From the measured mixing height, and from the developed relationship between NTU (=number of transfer units) and the concentration of $SO_2$(aq) in rain drops, the HTU (= height equivalent to one transfer unit, i.e. mass transfer resistance) was estimated, and validated with the field-measured data. In Seoul, Korea where the effect of $SO_2$ on rainfall acidity is as high as 84% and the average mixing height is 1 km, the average HTU of $SO_2$ system was found to be 191.5m. The important parameters affecting HTU were identified as rainfall intensity and initial ambient concentration of $SO_2$, and their effects on the value of overall volumetric mass transfer coefficient were quantified.

  • PDF

Multilayered Graphene Electrode using One-Step Dry Transfer for Optoelectronics

  • Lee, Seungmin;Jo, Yeongsu;Hong, Soonkyu;Kim, Darae;Lee, Hyung Woo
    • Current Optics and Photonics
    • /
    • 제1권1호
    • /
    • pp.7-11
    • /
    • 2017
  • In this study, multilayered graphene was easily transferred to the target substrate in one step using thermal release tape. The transmittance of the transferred graphene according to the number of layers was measured using a spectrophotometer. The sheet resistance was measured using a four-point probe system. Graphene formed using this transfer method showed almost the same electrical and optical properties as that formed using the conventional poly (methyl methacrylate) transfer method. This method is suitable for the mass production of graphene because of the short process time and easy large-area transfer. In addition, multilayered graphene can be transferred on various substrates without wetting problem using the one-step dry transfer method. In this work, this easy transfer method was used for dielectric substrates such as glass, paper and polyethylene terephthalate, and a sheet resistance of ~240 ohm/sq was obtained with three-layer graphene. By fabricating organic solar cells, we verified the feasibility of using this method for optoelectronic devices.

발전소용 공랭식 응축기(ACC)의 작동조건 변화에 따른 성능특성에 대한 수치적 연구 (A Numerical Study on the Performance Characteristics of a Power Plant Air-Cooled Condenser (ACC) Affected by Changes in Operating Conditions)

  • 박경민;주기홍;박창용
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.243-250
    • /
    • 2017
  • A numerical study was conducted to calculate the cooling capacity variation of a power plant ACC (air-cooled condenser) caused by changes in operating conditions. A numerical model was developed using the ${\varepsilon}-NTU$ and finite volume method, containing 100 elements for a single low fin tube. The model was validated through a comparison of cooling capacity between the simulated values and manufacturer's data. Even though simple assumptions and previously presented heat transfer correlations were applied to the model, the prediction error was 1.9%. The simulated variables of the operating conditions were air velocity, air temperature, and mass flux. The analysis on the variation of thermal resistance along the tube showed that the water side thermal resistance was higher than the air side thermal resistance at the downstream end of the tube, indicating that the ACC capacity could be increased by applying technology to enhance in-tube flow condensation heat transfer.