Variation of Concentration of Air Pollutants with Air Mass Back-Trajectory Analysis in Gyeongju (기단 역궤적분석에 의한 경주시 대기오염물질의 농도 변화)

  • Kim, Kyung-Won;Bang, So-Yung;Jung, Jong-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.162-175
    • /
    • 2008
  • Gyeongju, which was the central city of the ancient civilization at Silla Kingdom, has various kinds of stone cultural properties. It is significantly important to preserve historical sources of Korea. However, recent air quality data measured in Gyeongju did not show good air quality level. In order to investigate variation of the concentration of the air pollutants with meteorological condition, an air quality monitoring and an aerosol sampling were conducted during the intensive monitoring period in Gyeongju. Impacts of the meteorological factors on the air pollutants were also analyzed based on the air mass pathway categories using HYSPLIT model and the local wind patterns using MM5 model. The prevailing air mass pathways were classified into four categories as following; category I affected by easterly marine aerosols, category II affected by northwesterly continental aerosols, category III affected by southwesterly continental aerosols, and category IV affected by northerly continental aerosols. The concentrations of the air quality standards were relatively lower during the fall intensive monitoring period. At that time, the easterly marine air mass pattern was dominated. The seasonal average mass concentration of $PM_{10,Opt}$, which optically measured at the monitoring site, was the highest value of $77.6{\pm}28.3\;{\mu}g\;m^{-3}$ during the spring intensive monitoring period but the lowest value of $20.1{\pm}5.3\;{\mu}g\;m^{-3}$ during the fall intensive monitoring period. The concentrations of $SO_2$ and CO were relatively higher when the air mass came from the northwestern continent or the northern continent. The concentrations of ${SO_4}^{2-}$ and ${NO_3}^-$ increased under the northwesterly continental condition. It was estimated that the acidic aerosols were dominated in the atmosphere of Gyeongju when the air mass came from the continental regions.

A Study on the New Education and Training Scheme for Developing Seafarers in Seafarer 4.0 - Focusing on the MASS - (선원 4.0시대에 적합한 새로운 선원교육훈련 체계에 대한 연구 - 자율운항선박을 중심으로 -)

  • Lee, Chang-Hee;Yun, Gwi-ho;Hong, Jung-Hyeok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.6
    • /
    • pp.726-734
    • /
    • 2019
  • The current maritime industry is expected to have a significant impact on the role of maritime-related technologies and systems, especially seafarers, in the rapidly changing Fourth Industrial Revolution. The Maritime Autonomous Surface Ship (MASS) aims to reduce the number of safety accidents and improve seafarers' working environment. With regard to MASS, the International Maritime Organization has been trying to minimize unexpected impact in the maritime education and training sector by establishing international conventions such as the Standards of Training, Certification and Watchkeeping for Seafarers. However, domestic designated educational institutions have not yet established an education and training scheme to develop seafarers who will be on board for MASS. Therefore, this paper reviews the technology of MASS, analyzes the changes in education and training in order to upgrade the qualifications, and suggests the competencies of smart seafarers equipped with the integrated management ability required for Artificial Intelligence, Big Data, Cybersecurity, and the Digital System Revolution through education and training. In addition, this study provides basic information for the education and training of seafarers who are optimized for the rapidly changing technological environment.

Comparison of Seismic Velocity and Rock Mass Rating from in situ Measurement (현장 실험을 통한 암반 탄성파 속도와 암반평가 인자 비교)

  • Lee, Kang Nyeong;Park, Yeon Jun;Kim, Ki Seog
    • Tunnel and Underground Space
    • /
    • v.28 no.3
    • /
    • pp.232-246
    • /
    • 2018
  • In this study, the relationship between in situ seismic wave velocities and RMR (rock mass rating) was investigated in a test bed for the examination of the basis of rock classification (RMR) based on seismic wave velocity. The seismic wave velocity showed a monotonous increase with depth. It was also found that there was no systematic correlation between the seismic wave velocity (Vp) and other parameters (RQD, joint spacing, UCS, rock core Vp, and RMR) collected at the same depth of the same borehole. However, correlative relation was observed among RMR, RQD, and joint spacing. On the other hand, when all the data in the borehole (three holes) are examined without considering the depth, Vp still shows no correlation with RMR parameters (e.g., correlative coefficient for uniaxial compressive strength and joint spacing are 0.039 and 0.091, respectively), but Vp shows weak correlative relation with RMR and RQD (correlative coefficient for RQD and RMR are 0.193 and 0.211, respectively). Thus, it is found that it is difficult to deduce physical properties of rock mass directly from seismic wave velocities, but the seismic wave velocity can be used as a tool to approximate rock mass properties because of weaker correlation between Vp and RMR with RQD. In addition, the velocity value of for soft and moderate rocks suggested by widely used construction standards is slower than that of the observed velocity, implying that the standards need to be examined and revised.

A study on the digital image transfer application mass chest X-ray system up-grade (간접촬영기의 디지털 영상 변환 장치 적용에 대한 연구)

  • Kim, Sun-Chil;Park, Jong-Sam;Lee, Jon-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.13-17
    • /
    • 2003
  • By converting movable indirect mass chest X-ray devices for vehicles into digital systems and upgrading it to share information with the hospital's medical image information system, excellencies have been confirmed as a result of installing and running this type of system and are listed hereinafter. 1. Upgrading analog systems, such as indirect mass chest X-ray devices dependent on printed film, to digital systems allows them to be run and managed much more efficiently, contributing to the increase in the stability and the efficiency of the system. 2. Unlike existing images, communication based on DICOM standards allow images to be compatible with the hospital's outer and inner network PACS systems, extending the scope of the radiation departments information system. 3. Assuming chest-exclusive indirect mass chest X-rays, a linked development of CAD (Computer Aided Diagnosis, Detector) becomes possible. 4. By applying wireless Internet, Web-PACS for movable indirect mass chest X-ray devices for vehicles will become possible. Research in these fields must continue and if the superior image quality and convenience of digital systems are confirmed, I believe that the conversion of systems still dependent on analog images to modernized digital systems is a must.

  • PDF

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

Measurement of Physical Properties of Korean Garlic for Grade Standard

  • Hong, J.H.;Koh, H.K.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • Garlic is one of the major seasoning vegetables in Korea and consumed mostly in a form of peeled cloves. Conventional Korean standards for garlic grading consist of four classes according to the size of bulb and its shape. Sorting and grading of garlic are manually done but could be in the process of automated mechanization using machine vision system in the near future. The proportion of mass of cloves in a garlic bulb to the volume of the bulb (g/ml) was determined to find out the best way of representing both the quantity and quality of cloves in each bulb. Garlic bulb was assumed as an ellipsoid and its major and minor axis and its height were measured to calculate its volume. The mass proportions and density of a garlic bulb and cloves were measured for four domestic varieties of garlic to propose it as a standard for Korean garlic grading machine.

  • PDF

An anomalous dissociation of protonated cluster ions of DNA guanine-cytosine base-pair

  • Seong, Yeon-Mi;Han, Sang-Yun;Jo, Sung-Chan;Oh, Han-Bin
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.73-75
    • /
    • 2011
  • In the collisionally-activated dissociation of the proton-bound cluster ions of DNA base guanine (G) and cytosine (C), $G{\bullet}{\bullet}H^+{\bullet}{\bullet}C$, the abundance of [$CH^+$] ions was found to be higher than that of [$GH^+$] despite the fact that G has a higher proton affinity than C. This unexpected observation seems to demonstrate another example that the simple kinetic method scheme does not work. We suggest that a kinetic factor or detailed dynamics governing the proton transfer and dissociation should be carefully considered in the applications of the kinetic method to the proton affinity measurements.

Study of Formation and Development of Oxygen Deficient Water Mass, Using Ecosystem Model in Jinhae, Masan Bay (생태계 모델을 이용한 진해·마산만에서의 빈산소수괴의 형성 및 발달에 관한 연구)

  • Kim, Yeon-Joong;Kim, Myoung-Kyu;Yoon, Jung-Sung
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.41-50
    • /
    • 2010
  • This study established a 3D ecosystem model composed of stratification considering the topographic heat accumulation effect and river outflow, and then applied this model to Jinhae, Masan Bay. Specifically, it reenacted the formation and developmental process of ODW according to the stratification by calculating the kinematic eddy viscosity and eddy diffusion coefficient of the stratification model. The results were used as input data for the ecosystem model and compared with DO, COD, I-N, and I-P, which is the standard index of ocean water quality. As a result, it was determined that COD and T-N are third grade and T-P is second grade standards for a natural environment.

Improvements of Mass Measurement Rate for Moving Objects (이송 물체의 질량 측정 속도 향샹)

  • Lee, W.G.;Kim, K.P.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.11
    • /
    • pp.110-117
    • /
    • 1995
  • This study presents and algorithm and related techniques which could satisfy the important properties of check weighers and conveyor scales. The algorithm of Recursive Least Squares Regression is applied for the weighing system simulated as a dynamic model of the second order. Using the model and the algorithm, model parameters and then the mass being weighed can be determined from the step input. The performance of the algorithm was tested on a check weigher. Discussions were extended to the development of noise reduction techniques and to the lagged introduction of objects on the moving plate. It turns out that the algorithm shows several desirable features suitable for real-time signal processing with a microcomputer, which are high precision and stability in noisy environment.

  • PDF

Identification of Actinomycins by High Performance Liquid Chromatography and Fast Atom Bombardment Mass Spectrometry

  • Cho, Seong-Eun;Goo, Yang-Mo;Kim, Kyoung-Ja
    • Archives of Pharmacal Research
    • /
    • v.17 no.6
    • /
    • pp.424-427
    • /
    • 1994
  • An acinomycin complex isolated from culture broth of a soil microorganism, SNUS 9305-011 has been examined by High performance liquid chromatography (HPLC). From the analysis of the fractions obtained by column chromatography of the ethyl acetate extract, three actinomycin components are confimed . The HPLC analysis is carried out with a CN-bonded nucleosil column. Comparison of the retention times of the components with those of actinomycin D, C complex, $X_{o{\beta}$, and V and suggests that they are different actinomycins. FBA mass spectra fo the coponents also shows different molecular ions from those of standards and other reported actionbmycins. The present work has demonstrated that actinomycin components can be separated by a CN-bonded HPLC column, and that ocmparison of their HPLC chormatograms with authentic smaples and information on their molecular ions can be successfully employed for indentification of actionmycins.

  • PDF