• 제목/요약/키워드: Mass source

검색결과 1,441건 처리시간 0.023초

THERMAL DIFFUSION AND RADIATION EFFECTS ON UNSTEADY MHD FREE CONVECTION HEAT AND MASS TRANSFER FLOW PAST A LINEARLY ACCELERATED VERTICAL POROUS PLATE WITH VARIABLE TEMPERATURE AND MASS DIFFUSION

  • Venkateswarlu, M.;Ramana Reddy, G.V.;Lakshmi, D.V.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제18권3호
    • /
    • pp.257-268
    • /
    • 2014
  • The objective of the present study is to investigate thermal diffusion and radiation effects on unsteady MHD flow past a linearly accelerated vertical porous plate with variable temperature and also with variable mass diffusion in presence of heat source or sink under the influence of applied transverse magnetic field. The fluid considered here is a gray, absorbing/emitting radiation but a non-scattering medium. At time t > 0, the plate is linearly accelerated with a velocity $u=u_0t$ in its own plane. And at the same time, plate temperature and concentration levels near the plate raised linearly with time t. The dimensionless governing equations involved in the present analysis are solved using the closed analytical method. The velocity, temperature, concentration, skin-friction, the rate or heat transfer and the rate of mass transfer are studied through graphs in terms of different physical parameters like magnetic field parameter (M), radiation parameter (R), Schmidt parameter (Sc), Soret number (So), Heat source parameter (S), Prandtl number (Pr), thermal Grashof number (Gr), mass Grashof number (Gm) and time (t).

수직흡수기의 열 및 물질전달 촉진 (Enhancement of Heat and Mass Transfer for a Vertical Type Absorber)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.362-370
    • /
    • 1998
  • Absorption systems require a heat source for working but they have a great merit in that relatively low-temperature and low-quality types of thermal energy such as solar heat and exhaust heat can be effectively utilized as heat source. However details research related to absorbers which have a great effect on performances has been rarely done and thus there has been a strong hope for positive developments to improve their efficiencies. This paper describes absorption experiments made with different inside tube diameters and shapes. The purpose of this study is to acquire basic knowledge about heat and mass transfer in a falling film type absorber with vertical inner tubes. Heat and mass transfer were measured for water vapor absorption into a water/LiBr solution flowing down an absorber of vertical inner tubes. As a result absorption acceleration tube compares bare tube and heat transfer improved by order of insert spring tube corrugated tube grooved tube. And the acceleration that is good provided in inserting spring tube for both sides of heat and mass transfer.

  • PDF

Extraction Chromatograph Separation Spark Source Mass Spectrometric Analysis of 14 Rare Earth Impurities in High Purity Rare Earth Oxide

  • Sui, Xiyun;Wang, Zishu;Shao, Baohai
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.553-559
    • /
    • 1995
  • An extraction chromatographic method of separating rare earth impurities from high purity $Nd_2O_3$, $Sm_2O_3$, $Gd_2O_3$, $Er_2O_3$, $Dy_2O_3$ and $Yb_2O_3$ was studied by using $HCl-NH_4Cl$ as moving phase and P507 as stationary phase. After the impurities were enriched from the eluate by chelant-activated carbon, the active carbon was ashed and the ignited residue was used to prepare the sample electrode for spark source mass spectrometric determination. The impurities in 99.9999% rare earth oxide can be determined by the proposed method with recovery over 80%.

  • PDF

대기 분진의 무기 화학적 조성 분석과 Chemical Mass Balance에 의한 오염원 기여도 산출 (Characterization of Inorganic Chemicals in Total Suspended Particulates and a Source Apportionment by Chemical Mass Balance Model)

  • 서영화;구자공
    • 한국대기환경학회지
    • /
    • 제8권2호
    • /
    • pp.112-120
    • /
    • 1992
  • Twenty four metal, nonmetal elements and 4 major anions in total suspended particulates (TSP) collected at two sites in Daejon city from october to december in 1991 by a Hi-vol sampler were thoroughly analyzed by Inductively Coupled Plasma/ Atomic Emission Spectrometry (ICP/AES) and Ion Chromatography (IC). These analyzed data were used to perform a receptor modeling using the Chemical Mass Balance (CMB) for the source apportionment of TSP sample. Approximately 60% TSP weight in industrial complex area was influenced by potential industrial sources and 25% was by heating fuels and automobile emissions, whereas a half of TSP in residential area was influenced by surrounding environment and more than 35% of TSP was influenced by heating fuels. The CMB model provided source apportionment results reasonably and scientifically with a minor limitation.

  • PDF

암모니아-물 작동유체의 부분증발유동을 적용한 재생 랭킨사이클에 관한 연구 (Study on Regenerative Rankine Cycle with Partial-Boiling Flow Using Ammonia-Water Mixture as Working Fluid)

  • 김경훈
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.223-230
    • /
    • 2011
  • The power cycle using ammonia-water mixture as a working fluid is a possible way to improve efficiency of the system of low-temperature source. In this work thermodynamic performance of the ammonia-water regenerative Rankine cycle with partial-boiling flow is analyzed for purpose of extracting maximum power from the source. Effects of the system parameters such as mass fraction of ammonia, turbine inlet pressure or ratio of partial-boiling flow on the system are parametrically investigated. Results show that the power output increases with the mass fraction of ammonia but has a maximum value with respect to the turbine inlet pressure, and is able to reach 22 kW per unit mass flow rate of source air at $180^{\circ}C$.

서울시 PM-10 오염원의 정량적 기여도 추정 (Quantitative Source Estimation of PM-10 in Seoul Area)

  • 유정석;김동술;김윤신
    • 한국대기환경학회지
    • /
    • 제11권3호
    • /
    • pp.279-290
    • /
    • 1995
  • Recently in Korea, due to the significant drop of lead and bromine levels as a marker of autoemission source in the urban areas, the conventional application of receptor methods has many difficulties to properly apportion mass contribution of some sources. It is then needed to urgently develop alternative source profiles and identify new emission markers. Thus, the study has extensively examined the results obtained from using PAHs and elemental data for receptor modeling and has provided an opportunity to identify alternative source compositions and to determine a proper number of the ambient emission sources in Seoul area. The purpose of the study is to identify the sources of PM-10 and to estimate their mass contributions in Seoul area. Thus, a receptor model, target transformation factor analysis(TTFA) has been massively applied. The TTFA offers the possibility of determining the number of sources and their mass contributions. The input data used in this study are composed of two separate sets: fine (d$_{p}$ < 2.5.mu.m) and coarse (2.5.mu.m < d$_{p}$ < 10.mu.m) mode aerosol samples. Each sample was simultaneously collected by a PM-10 dichotomous sampler during the daytime(8 AM to 8 PM) and the nighttime(8 PM to 8 AM) from February to October 1993 on the Sungdong-Gu, Seoul. All the samples were analyzed to determine the levels of 10 inorganic elements by an XRF system as well as 14 PAHs by a HPLC. However, only 8 inorganic elements and 7 PAHs were used for the various statistical analysis.sis.

  • PDF

분진의 개수농도 및 질량농도에 입각한 서울시 지하철 역사 내 오염원의 기여도 결정 (Determination of Source Contribution Based on Aerosol Number and Mass Concentration in the Seoul Subway Stations)

  • 최형욱;황인조;김신도;김동술
    • 한국대기환경학회지
    • /
    • 제20권1호
    • /
    • pp.17-31
    • /
    • 2004
  • The subway play an important part in serious traffic problems. However, because subway system is a closed environment, many serious air pollution problems occurred in subway stations and injured passenger's health. Therefor, it is a necessary to identify sources and to estimate pollutant sources in order to protect passenger's health and to keep clean subway environment. The purpose of this study was to analyze a air quality in the subway stations and to apply a new receptor methodology for quantitatively estimate of PM10 sources. In this study, the size distributions of particulate matters has been measured by using Aerosizer LD (U.S.A., API, Inc.). It's real time measurement capability of time-of-flight technique offers a significant advantage of user convenience and air pollution management. Also, the mass concentrations of PM 10 has been measured by using mini-vol portable sampler (U.S.A., Airmetrics Co.). The sampling performed in Seoul subway stations during the period of February 2000 and April 2000. The number distribution data used in this study consisted of 26 raw data sets in the Jongno-sam-ga station. Correlation Analysis can be used in subway stations for source separation and identification. Then, number contribution from each source is determined by the particle number balance (PNB). The mass concentration data used in this study consisted of 31 raw data in the 8 different stations. The mass contributions of PM10 sources in the concourse by using PMF/CMB model.

CCSEM을 이용한 대기 중 개별분진의 분류에 관한 연구 (Classification of Individual Ambient Particles by CCSEM)

  • 장여진;김동술
    • 한국대기환경학회지
    • /
    • 제13권5호
    • /
    • pp.345-353
    • /
    • 1997
  • The purpose of the study was to stastically classify individual PM-10 measured by SEM/EDX (scanning electron microscopy/energy dispersive x-ray analyzer). The SEM/EDX provided various physical parameters like optical diameter, as well as major 18 chemical information (Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb) for a particle-by-particle basis. The total of 1,419 particles were analyzed for the study. Thus density and mass of each particle can be estimated based on its chemical composition. Further the study developed 4 semisource profiles including highway, oil boiler, incinerator, and soil emissions, where each sample was collected near the source in the ambient air The profiles developed were consisted of mass fractions and their uncertainties based on a particle class concept. To obtain mass fraction of each particle class, an agglomerative hierarchical cluster analysis was initially applied to create particle classes for each sample. Then uncertainties were calculated for each class based on the jacknife method. The 1,258 particles out of 1,419 (88.7%) were assorted in newly generated particle classes. The study provides opportunities to identify particle's source quantitatively and to develope various receptor models.

  • PDF

Analysis of Fatty Acyl Groups of Diacyl Galactolipid Molecular Species by HPLC/ESI-MS with In-source Fragmentation

  • Gil, Ji-Hye;Hong, Jong-Ki;Choe, Joong-Chul;Kim, Young-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1163-1168
    • /
    • 2003
  • The structures of molecular species of galactolipids, such as monogalactosyl diacylglycerol (MGDG) and digalactosyl diacylglycerol (DGDG), isolated from wheat flour have been investigated using negative-ion electrospray ionization (ESI) mass spectrometry interfaced with high performance liquid chromatography (HPLC). According to the result of HPLC analysis, MGDG and DGDG were found to consist of mixtures of five and four molecular species, respectively. The galactolipids have been also analyzed to determine their fatty acid compositions, using HPLC/ESI-MS combined with in-source (or cone voltage) fragmentation. HPLC/ ESI-MS is very useful for one-step analysis of mixtures of galactolipids with a small sample quantity. Especially, the carboxylate anions produced in in-source fragmentations of the negative-ion of each component separated by HPLC provide valuable information on the composition of its fatty acyl chains.

수용모델을 이용한 청주시 미세입자($PM_{2.5}$)의 기여도 추정 (Source Identification of Fine Particle($PM_{2.5}$) in Chongju Using a Chemical Mass Balance Model)

  • 강병욱;이학성;김희강
    • 한국대기환경학회지
    • /
    • 제16권5호
    • /
    • pp.477-485
    • /
    • 2000
  • The data set was collected on fifty-eight different days with a 24-h sampling period from October 27, 1995 through August 25, 1996. From the chemical mass balance (CMB) analysis of $PM_{2.5}$ in the Chongju area, the contributions from soil, gasoline, diesel, light and heavy oil combustion were 2.6%, 15.4%, 9.0%, 28.8% and 1.5%, respectively. Residual $NO_{3}^{-}$), residual $SO_{4}^{2-}$ and residual OC, possibly formed in the atmosphere. represented additional 8.0, 10.2, and 1.6% of the $PM_{2.5}$, respectively. Other unidentified sources constituted the remaining 22.9%. From the CMB analysis, the $PM_{2.5}$ source contribution for fall, winter, spring and summer were 92, 76.8, 77.5 and 59.2%, respectively.

  • PDF