• Title/Summary/Keyword: Mass measurement type

Search Result 156, Processing Time 0.027 seconds

Effect of an Individually Tailored Program Based on Self-Measurement of Blood Glucose on Health Behavior and HbA1c in Diabetes and Pre-diabetes Patients (자가혈당측정 기반의 개별 맞춤형 프로그램이 당뇨병 및 당뇨병 전단계 환자의 건강행태와 당화혈색소에 미치는 영향)

  • Kim, Yoon-kyung;Kim, Bo-Ra;Yoo, Eun-Suk;Yun, Seo-Yeong;Jeong, Mi-Jeong;Choi, Ji-Hye;Choi, Jae-Soon;Sung, Hyun-Jin;Kang, Young-Suk;Lee, Min-Sook;Hwang, Tae-Yoon
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.2
    • /
    • pp.67-77
    • /
    • 2022
  • Objective: This study was to evaluate the effectiveness of an individually tailored program based on self-measurement of blood glucose on health behavior and HbA1c in diabetes and pre-diabetes patients. Methods: The program consisted of seven sessions for 12 weeks which were carried out every two weeks. Almost all sessions were progressed on untact method except for the first and last session. The 71 subjects were assessed for their knowledge of diabetes, health behavior, the experience of self-measurement of blood glucose, body mass Index (BMI) and hemoglobin A1c (HbA1c) at before and after the program. They were also evaluated on their degree of utilization of blood glucose measurements after the program. Results: Each mean score on their knowledge of diabetes, health behavior and the experience of self-measurement of blood glucose was significantly increased from 14.77, 25.50, and 2.70 to 15.41, 28.40, and 4.81, respectively. Each mean score on both BMI and HbA1c (n=53) was significantly decreased from 24.47kg/m2 and 7.27% to 24.01kg/m2 and 6.67%, respectively. The post-HbA1c had a significant negative correlation(r=-0.415) with the degree of utilization of blood glucose measurements. The degree of utilization of blood glucose measurements had a significant positive correlation(r=0.581) with post-health behavior. Conclusions: The program shows effectiveness in improving HbA1c in Type 2 diabetes and pre-diabetes patients. The post-HbA1c might be related to the degree of utilization of blood glucose measurements which might be related to the health behavior.

The progress in NF3 destruction efficiencies of electrically heated scrubbers (전기가열방식 스크러버의 NF3 제거 효율)

  • Moon, Dong Min;Lee, Jin Bok;Lee, Jee-Yon;Kim, Dong Hyun;Lee, Suk Hyun;Lee, Myung Gyu;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.535-543
    • /
    • 2006
  • Being used widely in semiconductor and display manufacturing, $NF_3$ is internationally considered as one of the regulated compounds in emission. Numerous companies have been continuously trying to reduce the emissions of $NF_3$ to comply with the global environmental regulation. This work is made to report the destruction and removal efficiency (DRE) of electrically heated scrubbers and the use rate in process chambers installed in three main LCD manufacturing companies in Korea. As the measurement techniques for $NF_3$ emission, mass flow controlled helium gas was continuously supplied into the equipment by which scrubber efficiency is being measured. The partial pressures of $NF_3$ and helium were accurately measured for each sample using a mass spectrometer, as it is emitted from inlet and outlet of the scrubber system. The results show that the DRE value for electrically heated scrubbers installed before 2004 is less than 52 %, while that for the new scrubbers modified based on measurement by scrubber manufacturer has been sigificentely improved upto more than 95 %. In additon, we have confirmed the efficiency depends on such variables as the inlet gas flow rate, water content, heater temperature, and preventative management period. The use rates of $NF_3$ in process chambers were also affected by the process type. The use rate of radio frequency source chambers, built in the $1^{st}$ and $2^{nd}$ generation process lines, was determined to be less than 75 %. In addition, that of remote plasma source chambers for the $3^{rd}$ generation was measured to be aboove 95 %. Therefore, the combined application of improved scrubber and the RPSC process chamber to the semiconductor and display process can reduce $NF_3$ emmision by 99.95 %. It is optimistic that the mission for the reduction of greenhouse gas emission can be realized in these LCD manufacturing companies in Korea.

Development and Verification of a Large Scale Resonant Column Testing System (대형 공진주시험기의 개발 및 검증)

  • Kim, Nam-Ryong;Ha, Ik-Soo;Shin, Dong-Hoon;Kim, Min-Seub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.295-304
    • /
    • 2012
  • In this study, a resonant column testing system which is the largest in Korea has been developed to evaluate the dynamic deformation characteristics of coarse granular geomaterials, and the performance and the applicability of the testing system have been verified. The system has been developed as a typical Stokoe type device whose boundary conditions are fixed bottom and free top with additional mass, and can adopt a large specimen with 200 mm in diameter and 400 mm in height. The driving and measurement instruments are configured as high performance and precision systems, hence the automated testing system is appropriate to drive enough stress and to measure the behavior precisely for the test in practical manner. The dynamic response of the mechanical components and the applicability of the system have been evaluated using metal specimens as well as polyurethane specimens, and its precision was verified by comparing its results with those from other equipment and/or methods. To confirm the applicability of the large system for coarse geomaterials, the resonant column test results from both large and normal scale apparatus for the same material were compared and it was found that the result can be partially affected by scale. Finally, the dynamic deformation characteristics of coarse geomaterial which is used for construction of large dam was evaluated using the large system and its practicality could be confirmed.

Non-alcoholic Fatty Liver Disease (NAFLD) and Significant Hepatic Fibrosis Defined by Non-invasive Assessment in Patients with Type 2 Diabetes

  • Sobhonslidsuk, Abhasnee;Pulsombat, Akharawit;Kaewdoung, Piyaporn;Petraksa, Supanna
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1789-1794
    • /
    • 2015
  • Background: Non-alcoholic fatty liver disease (NAFLD), the most common liver problem in diabetes, is a risk factor for liver cancer. Diabetes, high body mass index (BMI) and old age can all contribute to NAFLD progression. Transient elastography (TE) is used for non-invasive fibrosis assessment. Objectives: To identify the prevalence of NAFLD and significant hepatic fibrosis in diabetic patients and to assess associated factors. Materials and Methods: One hundred and forty-one diabetic and 60 normal subjects were screened. Fatty liver was diagnosed when increased hepatic echogenicity and vascular blunting were detected by ultrasonography. Liver stiffness measurement (LSM) representing hepatic fibrosis was assessed by TE. LSM ${\geq}7$ kPa was used to define significant hepatic fibrosis. Results: Four cases were excluded due to positive hepatitis B viral markers and failed TE. Diabetic patients had higher BMI, systolic blood pressure, waist circumference and fasting glucose levels than normal subjects. Fatty liver was diagnosed in 82 (60.7%) diabetic patients but in none of the normal group. BMI (OR: 1.31; 95%CI: 1.02-1.69; p=0.038) and alanine aminotransferase (ALT)(OR: 1.14; 95%CI: 1.05-1.23; p=0.002) were associated with NAFLD. Diabetic patients with NAFLD had higher LSM than those without [5.99 (2.4) vs 4.76 (2.7) kPa, p=0.005)]. Significant hepatic fibrosis was more common in diabetic patients than in normal subjects [22 (16.1%) vs 1 (1.7%), p=0.002]. Aspartate aminotransferase (AST)(OR: 1.24; 95%CI: 1.07-1.42; p=0.003) was associated with significant hepatic fibrosis. Conclusions: Sixty and sixteen percent of diabetic patients were found to have NAFLD and significant hepatic fibrosis. High BMI and ALT levels are the predictors of NAFLD, and elevated AST level is associated with significant hepatic fibrosis.

Visual Interpretation about the Underground Information using Borehole Camera (휴대용 시추공 카메라를 이용한 지하정보의 가시화 기법)

  • Matsui Kikuo;Jeong Yun-Young
    • Tunnel and Underground Space
    • /
    • v.15 no.1 s.54
    • /
    • pp.28-38
    • /
    • 2005
  • According to the recent development of measurement system utilizing one or a set of boreholes, visualization of the explored underground became to be a major issue. It induced even the introduction of monitoring apparatuses on the borehole wall with multi-function tool, but the usage of these was often limited by where is unfavorable rock condition and a few of engineers can approach. And so, a portable type of borehole camera with only the essential function has been investigated and a few of commercial models about this is recently being applied into the field condition. This paper was based on the monitoring results obtained using a commercial model by Dr. Nakagawa. Discontinuities in rock mass were the topic for the visualization, and it was studied how can visualize their three dimensional distribution and what a numerical formulation is needed and how to understand the visualization result. The numerical formulation was based on the geometric correlation between the dip direction / dip of discontinuous plane and the trend / plunge of borehole, a set of the equation of a plane was induced. As field application of this into two places, it is found that the above visualization methodology will be especially an useful geotechlical tool for analyzing the local distribution of discontinuities.

Field Performance Evaluation of Candidate Samplers for National Reference Method for PM2.5 (PM2.5 국가기준측정장비 선정을 위한 비교 측정 연구)

  • Lee, Yong Hwan;Park, Jin Su;Oh, Jun;Choi, Jin Soo;Kim, Hyun Jae;Ahn, Joon Young;Hong, You Deog;Hong, Ji Hyung;Han, Jin Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.157-163
    • /
    • 2015
  • To establish National Reference Method (NRM) for $PM_{2.5}$, operational performance of 5 different commercial gravimetric-based $PM_{2.5}$ measuring instruments was assessed at Bulkwang monitoring station from January 23, 2014 to February 28, 2014. First, physical properties, design, and functional performance of the instruments were assessed. Evaluation was carried out to determine whether operating method for the instruments and levels of QA/QC activities meet the data quality objectives (DQOs). To verify whether DQOs were satisfied, reproducibility of QA/QC procedures, accuracy, relative sensitivity, limit of detection, margin of error, and coefficient of determination of the instruments were also evaluated. Results of flow rate measurement of 15 candidate instruments indicated that all the instruments met performance criteria with accuracy deviation of 4.0% and reproducibility of 0.6%. Comparison of final $PM_{2.5}$ mass concentrations showed that the coefficient of determination ($R^2$) values were greater than or equal to 0.9995, and concentration gradient ranged from 0.97 to 1.03. All the instruments satisfied criteria for NRM with the estimated precision of 1.47~2.60%, accuracy of -1.90~3.00%, and absolute accuracy of 1.02~3.12%. This study found that one particular type of measuring instrument was proved to be excellent, with overall evaluation criteria satisfied.

Theoretical Analysis of Critical Chloride Content in (Non)Carbonated Concrete Based on Characteristics of Hydration of Cement (시멘트 수화 특성 및 탄산화를 고려한 콘크리트의 임계 염소이온량에 대한 해석 기법)

  • Yoon, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.367-375
    • /
    • 2007
  • Critical chloride content for corrosion initiation is a crucial parameter in determining the durability and integrity of reinforced concrete structures, however, the value is still ambiguous. Most of the studies reporting critical threshold chloride content have involved the experimental measurement of the average amount of the total chloride content at arbitrary time. The majority of these researches have not dealt with this issue combined with carbonation of concrete, although carbonation can significantly impact on critical threshold chloride content. Furthermore, the studies have tried to define the critical chloride content within the scope of their experimental concrete mix proportion at arbitrary time. However, critical chloride content for corrosion initiation is known to be affected by a lot of factors including cement content, type of binder, chloride binding, concentration of hydroxyl ions, and so on. It is necessary to define the unified formulation to express the critical chloride content for various mix proportions of concrete. The purpose of this study is to establish an analytical formulation of the critical chloride content of concrete. In this formulation, affecting factors, such as mix proportion, environment, chemical evolution of pore solution with elapsed time, carbonation of concrete and so on are taken into account. Based on the Gouda's experimental results, critical chloride content is defined as a function of $[Cl^-]$ vs. $[OH^-]$ in pore solution. This is expressed as free chloride content with mass unit to consider time evolution of $[OH^-]$ content in pore solution using the numerical simulation programme of cementitious materials, HYMOSTRUC. The result was compared with other experimental studies and various codes. It is believed that the approach suggested in this study can provide a good solution to determine the reasonable critical chloride content with original source of chloride ions, for example, marine sand at initial time, and sea water penetration later on.

The metabolic syndrome and body composition in childhood cancer survivors

  • Sohn, Young-Bae;Kim, Su-Jin;Park, Sung-Won;Kim, Se-Hwa;Cho, Sung-Yoon;Lee, Soo-Hyun;Yoo, Keon-Hee;Sung, Ki-Woong;Chung, Jae-Hoon;Koo, Hong-Hoe;Jin, Dong-Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.6
    • /
    • pp.253-259
    • /
    • 2011
  • Purpose: Long-term survivors of childhood cancer appear to have an increased risk for the metabolic syndrome, subsequent type 2 diabetes and cardiovascular disease in adulthood compared to healthy children. The purpose of this study was to investigate the frequency of the metabolic syndrome and associated factors in childhood cancer survivors at a single center in Korea. Methods: We performed a retrospective review of medical records of 98 childhood cancer survivors who were diagnosed and completed anticancer treatment at Samsung Medical Center, Seoul, Korea between Jan. 1996 and Dec. 2007. Parameters of metabolic syndrome were evaluated between Jan. 2008 and Dec. 2009. Clinical and biochemical findings including body fat percentage were analyzed. Results: A total of 19 (19.4%) patients had the metabolic syndrome. The median body fat percentage was 31.5%. The body mass index and waist circumference were positively correlated with the cranial irradiation dose (r=0.38, P<0.001 and r=0.44, P<0.00, respectively). Sixty-one (62.2%) patients had at least one abnormal lipid value. The triglyceride showed significant positive correlation with the body fat percentage (r=0.26, P=0.03). The high density lipoprotein cholesterol showed significant negative correlation with the percent body fat (r=- 0.26, P=0.03). Conclusion: Childhood cancer survivors should have thorough metabolic evaluation including measurement of body fat percentage even if they are not obese. A better understanding of the determinants of the metabolic syndrome during adolescence might provide preventive interventions for improving health outcomes in adulthood.

A Study on the Educational Effectiveness of Chronic Diseases Among University Students (일부 대학생들의 성인건강 교육의 효과에 관한 연구)

  • Kang, Hee-Sook;Cho, Hyun
    • Journal of the Korean Society of School Health
    • /
    • v.8 no.1
    • /
    • pp.143-154
    • /
    • 1995
  • Korea has been recently reducing the quality of life as well as rising medical cost because of the increase of chronic diseases. But we can prevent those chronic diseases through the improvement of environment or life style. We evaluated the educational effectiveness of chronic diseases(hypertention, diabetes, cancer, stroke and other chronic diseases) designed to increase the knowledge, attitude and practice of chronic diseases among university students. Between August 1994 and November 1994, we implemented chronic diseases prevention instruction in intervention students; unmatched control students were selected in same university. We conducted pre- and post-intervention surveys both intervention and control students with self-reported questionnaires(50 items). We assigned score(0-4 points) to items and conducted a analysis of covariance(ANCOVA) with sex, grade and economic status as the covariate, using the SAS PC computer statistical package. And we culculated odds ratio with safety scores between intervention and control students. The results of this study were followed. 1. In demographic characteristics of subjects both pre- and post intervention, we found no significant differences in intervention and control students at religion, father's education, mother's education, mother's occupation and type of residence(p>0.05), but we found significant differences at sex(p<0.001), grade(p<0.001) and economic status(p<0.05). 2. The sex, grade and economic status-adjusted mean prevention knowledge scores for diabetes and stroke increased from the pre- to post-survey in the intervention students(p<0.001), but control students did not increased(p>0.05). As odds ratios in knowledge were below 1, the knowledge of intervention students were higher than control students. 3. The attitudes for general adult health increased from the pre- to post-survey in the intervention students(p<0.05), but control students did not increased(p>0.05). As odds ratios in attitudes were approximately 1, we can not say effectiveness in intervention students 4. The pratices for cancer and stroke increased from the pre- to post-survey in both the intervention and control students(p<0.001). Also odds ratio of hypertention was 0.91, and that of stroke was 1.14. 5. Health related behaviors did not increased from the pre- to post- survey in both the intervention and control students(p>0.05). But odds ratio of drinking was 0.76 and that of body weight was 1.21. 6. Health status did not increased from the pre- to post- survey in both the intervention and control students(p>0.05). As odds ratio of health status was 1.09, prevention education was not effect in intervention students We would like to recommend as follows; 1. University students must learn about prevention of chronic diseases. Because the knowledge of invetervention students was higher than that of control students. 2. The prevention education of chronic diseases should be taught from primary school. 3. Adult health education for university students must be practiced continuously. Education period(l5 weeks) in this study was not complete. 4. The evaluation of chronic diseases was conducted real measurement(such as BP check) as well as self reported-survey. 5. Educational materials(video tape, pamphlet) related the prevention of chronic diseases should be developed at national level. And we must easely use those materials. 6. The prevention education of chronic diseases should be made through mass media as well as school education.

  • PDF

A Study on Driving Safety Evaluation Criteria of Personal Mobility (퍼스널 모빌리티(Personal Mobility)의 주행안전성 평가지표 연구)

  • Park, Bumjin;Roh, Chang-gyun;Kim, Jisoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.5
    • /
    • pp.1-13
    • /
    • 2018
  • Divers types of Personal Mobility(PM) are appeared on the market after the Segway is introduced. PMs have propagated very rapidly with their ease of use, and accidents related with PM show a sudden increase. Many studies on the PM are performed as its trend, but dring safety of passengers are excluded. In this study, criteria which can be adopted for PM's driving safety evaluation are reviewed. Also result of driving safety evaluation on 3 types of PM(wheel chair, kickboard, scooter(seating/standing) and walking using deducted criteria is given. COG(Center of the gravity) and SM(Stability Metric) are finally selected two criteria among many of them used in other fields. COG indicates how the center of mass deviates from the direction of the gravity. SM is a normalized value of generated force when PM moves as internal force, angular momentum, and ground reaction force. 0 means stop, and negative value means rollover, so it can be used for safety evaluation of PM. Average and standard deviation of measurement are standard of safety on the COG analysis. Wheel chair is the most safe and kickboard is the most unstable on the COG analysis. Wheel chair is also ranked as top safe on the SM analysis. Among two riding types(seating and standing) on the scooter, seating type is evaluated more safer than standing type. It is proposed that more various type of PMs are need to get safety evaluation for drivers and devices themselves together.