• Title/Summary/Keyword: Mass loss rate

Search Result 400, Processing Time 0.026 seconds

A Study on the Estimation of the Coefficient of Electrolytic Corrosion according to Concrete Compressive Strength (콘크리트 강도에 따른 철근의 전식계수 산정에 관한 연구)

  • Kang, Taek-Sun;Jee, Namyong;Yoon, Sang-Chun;Kim, Jae-Hun;Kim, Dong-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.834-837
    • /
    • 2004
  • In this study, the electric accelerated reinforcing bar corrosion test was carried out to estimate the coefficient of electrolytic corrosion based on the concept of Faraday's law according to rebar corrosion rate and concrete compressive strength which had an effect on the actual corrosion mass loss. The results of this paper allow the prediction of corrosion amount in the electric accelerated reinforcing bar corrosion test method.

  • PDF

Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature (외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구)

  • Byun, Jae-Ki;Lee, Kyu-Ho;Cho, Young-Don;Shin, Jong-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

A Study on 2D Modelling of Gas Turbine Engine Intake for Installed Performance Analysis (가스터빈 엔진의 장착성능 해석을 위한 흡입구 2D 모델링에 관한 연구)

  • Kong, Chang-Duk;Kho, Seong-Hee;Ki, Ja-Young;Jun, Yong-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.335-338
    • /
    • 2007
  • This study carried out the 2D modeling for estimating the intake loss that is a important installed loss for the precise installed performance analysis of a gas turbine engine, and the 0D performance map that represents intake pressure loss change depending on flight Mach number and air mass flow rate was generated using the 2D modeling results. In order to evaluate the generation procedure of the intake performance map, the intake map generation was applied to a commercial aircraft intake configuration.

  • PDF

A Comparative Study on Heat Loss in Rock Cavern Type and Above-Ground Type Thermal Energy Storages (암반공동 열에너지저장과 지상식 열에너지저장의 열손실 비교 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.442-453
    • /
    • 2013
  • A large-scale high-temperature thermal energy storage(TES) was numerically modeled and the heat loss through storage tank walls was analyzed using a commercial code, FLAC3D. The operations of rock cavern type and above-ground type thermal energy storages with identical operating condition were simulated for a period of five consecutive years, in which it was assumed that the dominant heat transfer mechanism would be conduction in massive rock for the former and convection in the atmosphere for the latter. The variation of storage temperature resulting from periodic charging and discharging of thermal energy was considered in each simulation, and the effect of insulation thickness on the characteristics of heat loss was also examined. A comparison of the simulation results of different storage models presented that the heat loss rate of above-ground type TES was maintained constant over the operation period, while that of rock cavern type TES decreased rapidly in the early operation stage and tended to converge towards a certain value. The decrease in heat loss rate of rock cavern type TES can be attributed to the reduction in heat flux through storage tank walls followed by increase in surrounding rock mass temperature. The amount of cumulative heat loss from rock cavern type TES over a period of five-year operation was 72.7% of that from above-ground type TES. The heat loss rate of rock cavern type obtained in long-period operation showed less sensitive variations to insulation thickness than that of above-ground type TES.

SIMULATION STUDIES ON A REDUCED-SCALE SUBWAY COACH FIRE (지하철 축소모형 객차화재 수치해석적 연구)

  • Kim, K.W.;Park, W.H.;Kim, C.H.;Jung, W.S.;Lee, D.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.501-504
    • /
    • 2010
  • In this study, fire behavior for subway coach fire in the 1/10 reduced scale model is analyzed using numerical analysis method (FDS). The size of the reduced model coach is 1.9 m long, 0.290 m high and 0.235 m. The simulation is carried out only one-sided four doors of the coach are opened. A fire source is the n-heptane pool fire with a mean heat release rate 2.33 kW. Smoke temperature, heat release rate and mass loss rate for the model are calculated.

  • PDF

CONE CALORIMETER STUDIES OF WOOD SPECIES

  • Grexa, Ondrej;Horvathova, Elena;Osvald, Anton
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.77-84
    • /
    • 1997
  • Cone calorimeter measurements can be used for the calculation of effective material properties, which can be used as input parameters in modeling of fire. Main parameter measured in Cone calorimeter is heat release rate. Some other parameters as time to ignition, effective heat of combustion, mass loss rate or total heat released is also measured in Cone calorimeter. Total heat released is important from the point of view of total energy available in material in Fire situation. Cone calorimeter. measurements were done on several wood species (oak, beech, spruce, poplar). Measurements were provided at external irradiances 30, 50 and 65 ㎾/$m_2$ in horizontal orientation. Heat release rate data were evaluated and compared as a function of external irradiance for various species of wood. furthermore the influence of external irradiance on effective heat of combustion and total heat release was also evaluated for the period of flame combustion.

  • PDF

Western dietary pattern is associated with higher risk of lower lean muscle mass in Korean postmenopausal women: data from the Korea National Health and Nutrition Examination Survey 2008-2011

  • Vijayakumar, Aswathy;Kim, Yangha;Kim, Hyesook;Kwon, Oran
    • Nutrition Research and Practice
    • /
    • v.15 no.4
    • /
    • pp.528-540
    • /
    • 2021
  • BACKGROUND/OBJECTIVES: In a healthy person, from 35 years of age, there is an annual loss of muscle mass at the rate of 1-2% and is associated with a decline in the quality of life. This study aimed to identify the particular dietary patterns associated with the risk of lower lean muscle mass in Korean postmenopausal women. SUBJECTS/METHODS: The Korea National Health and Nutrition Examination Survey (KNHANES) is a population-based, continuous cross-sectional annual survey. The participants of the KNHANES IV (2008-2009) and V (2010-2011) were considered for this study. The study sample consisted of 1548 postmenopausal women, aged 45-86 years. Lower lean muscle mass was defined as having appendicular skeletal muscle mass corrected for body weight less than 1 standard deviation of the young reference group aged 20 to 39 years in KNHANES IV and V. To identify the dietary pattern using factor analysis, 24-h recall data was used. RESULTS: The prevalence of lower lean muscle mass was 31.3% in this study population. Four dietary patterns were identified by factor analysis; 'Diverse', 'Western', 'Traditional', and 'Snacks and beverages'. The 'Western' pattern, highest factor loadings for flour and bread, potatoes, red meat, processed meat, eggs, and cheese, was significantly associated with a high (60%) risk of lower lean muscle mass (odds ratio [95% confidence interval] = 1.60 [1.07-2.39], P for trend = 0.01) after adjustments for potential covariates. The other 3 dietary patterns were not associated with lower lean muscle mass. CONCLUSIONS: The study findings suggest that the 'Western' dietary pattern that includes flour and bread, potatoes, red meat, processed meat, eggs, and cheese, may be associated with a higher risk of lower lean muscle mass in Korean postmenopausal women.

Thermal Analysis of a Liquid Hydrogen Vessel with Multi-Layer-Insulation and Vapor-Cooled Shield (다층단열재와 증기냉각쉴드를 사용한 액체수소 저장용기의 열해석)

  • Jung, Il-Kwon;Kang, Byung-Ha
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.3
    • /
    • pp.284-289
    • /
    • 2005
  • Thermal analysis of cryogenic-capable vessels with insulations have been carried out to store liquid hydrogen($LH_2$). The combined insulations of MLI(Multi-Layer Insulation) and VCS(Vapor-Cooled Shield) under high vacuum are considered in the analysis for various volumes of vessels. Vapor-Cooled Shields(VCS) are installed at cylinder wall as well as disc side of the $LH_2$ vessels. The results indicate that optimal distribution of boiloff vapor from $LH_2$ vessel into two sides of VCS exists based on the evaporation loss. As the volume of $LH_2$ vessel is increased, mass flow rate of boiloff is increased while the evaporation loss per unit volume is decreased.

PERFORMANCE ANALYSIS OF A STATISTICAL MULTIPLEXER WITH THREE-STATE BURSTY SOURCES

  • Choi, Bong-Dae;Jung, Yong-Wook
    • Communications of the Korean Mathematical Society
    • /
    • v.14 no.2
    • /
    • pp.405-423
    • /
    • 1999
  • We consider a statistical multiplexer model with finite buffer capacity and finite number of independent identical 3-state bursty voice sources. The burstiness of the sources is modeled by describing both two different active periods (at the rate of one packet perslot) and the passive periods during which no packets are generated. Assuming a mixture of two geometric distributions for active period and a geometric distribution for passive period and geometric distribution for passive period, we derive the recursive algorithm for the probability mass function of the buffer contents (in packets). We also obtain loss probability and the distribution of packet delay. Numerical results show that the system performance deteriorates considerably as the variance of the active period increases. Also, we see that the loss probability of 2-state Markov models is less than that of 3-state Markov models.

  • PDF