• Title/Summary/Keyword: Mass function

Search Result 2,109, Processing Time 0.027 seconds

Effect of Dry Deposition on Water Quality -The comparison of several methodologies for estimating dry deposition flux (수질에 대한 대기건식침적의 영향 - 건식침적량 추정 방법론의 비교를 중심으로)

  • Cheong, Jang-Pyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.159-168
    • /
    • 2008
  • A special field experiment has been carried out from March 2001 to June 2001 at the Changhowon in Kyunggi to investigate a better methodology for the estimation of dry deposition of pollutions applicable in Korea. In this study, dry deposition plate was used to measure of total and water soluble acidic mass fluxes, and CPRI(Coarse Particle Rotary Impactor), CI(Cascade Impactor) were also used to measure ambient concentrations in various particle size ranges. Sehmel-Hodgson model was used to estimate dry depostion velocity and Weibull probability distribution function was applied to get generalized particle size distribution for the size fractioned concentration data sampled by CPRI and CI. Atmospheric dry deposition fluxes of mass and ionic matters estimated by the various techniques(one-step, multi-step, equi-concentration, subdivision for only the coarse particle range, applying Weibull distribution function, etc.) were compared to flux data sampled by DDP. It was found out that the deposition fluxes estimation methodology calculated by the each particle size range devided by particle size distribution characteristics and the rapidly changed points of deposition velocity using Weibull probability distribution function was the most applicable.

Correlations between Body Indices and Flow-Volume Curve Parameters (신체지표와 유량-기량곡선 지표간의 상관성)

  • Jin, Bok-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.3
    • /
    • pp.135-139
    • /
    • 2009
  • Pulmonary function test has been know to be greatly affected by body indices, such as sex, age, height, body weight, body surface area (BSA) and body mass index (BMI), so hat this study was focused to see the relationship between body index and flow-volume curves. Subjects were 156 (male 90, female 66) and they were examined for pulmonary function test in terms of body index and correlation/multiple regression analysis of flow-volume curves at Presbyterian Medical Center from March to August, 2009. The followings results after analyzing the correlation between body index and flow-volume curves. Although flow-volume curve FEF25-75% showed close correlation with age, body weight, and body surface area, but not with body mass index. In addition, multiple regression analysis was performed to see how each body index affects flow-volume curve FEF25-75%, and FEF25-75% dispersion was explained as 74.5% with age only, 94.2% with age and height, and 96% with age, height, and sex. Therefore, sex, age and height that are mainly used for predictive formular of pulmonary function test and nomogram were important factors for pulmonary function test itself, and further study must be done for other body index.

  • PDF

GEMINI NEAR-IR PHOTOMETRY OF THE ARCHES CLUSTER NEAR THE GALACTIC CENTER

  • YANG YUJIN;PARK HONG SOO;LEE MYUNG GYOON;LEE SANG-GAK
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.3
    • /
    • pp.131-141
    • /
    • 2002
  • We present Near-IR photometry of the Arches cluster, a young and massive stellar cluster near the Galactic center. We have analyzed the high resolution (FWHM $\~$ 0.2") Hand K' band images in the Galactic Center Demonstration Science Data Set, which were obtained with the Gemini/Hokupa's adaptive optics (AO) system. We present the color-magnitude diagram, the luminosity function and the initial mass function (IMF) of the stars in the Arches cluster in comparison with the HST/NICMOS data. The IMF slope for the range of 1.0 < log (M/M$\bigodot$) < 2.1 is estimated to be ${\Gamma} = -0.79 {\pm} 0.16$, in good agreements with the earlier result based on the HST/NICMOS data [Figer et al. 1999, ApJ, 525, 750]. These results strengthen the evidence that the IMF of the bright. stars close to the Galactic center is much flatter than that for the solar neighborhood. This is also consistent with a recent finding that the IMFs of the bright stars in young clusters in M33 get flatter as the galactocentric distance decreases [Lee et al. 2001, astro-ph 0109258]. It is found that the power of the Gemini/ AO system is comparable, with some limits, to that of the HST/NICMOS.

Chromosome-Centric Human Proteome Study of Chromosome 11 Team

  • Hwang, Heeyoun;Kim, Jin Young;Yoo, Jong Shin
    • Mass Spectrometry Letters
    • /
    • v.12 no.3
    • /
    • pp.60-65
    • /
    • 2021
  • As a part of the Chromosome-centric Human Proteome Project (C-HPP), we have developed a few algorithms for accurate identification of missing proteins, alternative splicing variants, single amino acid variants, and characterization of function unannotated proteins. We have found missing proteins, novel and known ASVs, and SAAVs using LC-MS/MS data from human brain and olfactory epithelial tissue, where we validated their existence using synthetic peptides. According to the neXtProt database, the number of missing proteins in chromosome 11 shows a decreasing pattern. The development of genomic and transcriptomic sequencing techniques make the number of protein variants in chromosome 11 tremendously increase. We developed a web solution named as SAAvpedia for identification and function annotation of SAAVs, and the SAAV information is automatically transformed into the neXtProt web page using REST API service. For the 73 uPE1 in chromosome 11, we have studied the function annotaion of CCDC90B (NX_Q9GZT6), SMAP (NX_O00193), and C11orf52 (NX_Q96A22).

Pure Density Evolution of the Ultraviolet Quasar Luminosity Function at 2 < z < 6

  • Kim, Yongjung;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.53.2-53.2
    • /
    • 2021
  • Quasar luminosity function (QLF) shows the active galactic nucleus (AGN) demography as a result of the combination of the growth and the evolution of black holes, galaxies, and dark matter halos along the cosmic time. The recent wide and deep surveys have improved the census of high-redshift quasars, making it possible to construct reliable ultraviolet (UV) QLFs at 2 < z < 6 down to M1450 = -23 mag. By parameterizing these up-to-date observed UV QLFs that are the most extensive in both luminosity and survey area coverage at a given redshift, we show that the UV QLF has a universal shape, and their evolution can be approximated by a pure density evolution (PDE). In order to explain the observed QLF, we construct a model QLF employing the halo mass function, a number of empirical scaling relations, and the Eddington ratio distribution. We also include the outshining of AGN over its host galaxy, which made it possible to reproduce a moderately flat shape of the faint end of the observed QLF (slope of ~ -1.1). This model successfully explains the observed PDE behavior of UV QLF at z > 2, meaning that the QLF evolution at high redshift can be understood under the framework of halo mass function evolution. The importance of the outshining effect in our model also implies that there could be a hidden population of faint AGNs (M1450 > -24 mag), which are buried under their host galaxy light.

  • PDF

Relationship between Body Mass Index and Insulin Resistance and Beta Cell Function by Obesity Type in Obese Middle-Aged Men (비만 중년 남성의 비만 유형별 체질량지수와 인슐린저항성 및 베타세포 기능간의 관련성)

  • Shin, Kyung-A
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.155-162
    • /
    • 2020
  • This study wanted to confirm the relevance between body mass index(BMI) and insulin resistance and beta-cell function based on abdominal obesity in obese middle-aged men. This study targeted 797 obese middle-aged men who had undergone health checkups at general hospitals in Gyeonggi-do from January 2018 to June 2020. There were 327 in the group with abdominal obesity and 470 in the group without abdominal obesity. Glucose(p<0.001), HbA1c(p=0.003), insulin(p<0.001), HOMA-IR(p<0.001) was different between groups. BMI was a factor affecting insulin resistance and beta cell function regardless of the with or without of abdominal obesity. BMI was associated with the onset of disease of insulin resistance and beta cell functional degradation regardless of the with or without of abdominal obesity. Therefore, it is considered necessary to manage the indicators of the BMI through exercise programs and regular checkups for health management of middle-aged obese men.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

THE DYNAMICAL EVOLUTION OF GLOBULAR CLUSTERS WITH STELLAR MASS LOSS

  • Kim, Chang-Hwan;Chun, Mun-Suk;Min, Kyung-W.
    • Journal of Astronomy and Space Sciences
    • /
    • v.8 no.1
    • /
    • pp.11-23
    • /
    • 1991
  • The dynamical evolution of globular clusters is studied using the orbit-averaged multicomponent Fokker-Planck equation. The original code developed by Cohn(1980) is modi-fied to include the effect of stellar evolutions. Plommer's model is chosen as the initial density distribution with the initial mass function index $\alpha$=0.25, 0.65, 1.35, 2.35, and 3.35. The mass loss rate adopted in this work follows that of Fusi-Pecci and Renzini(1976). The stellar mass loss acts as the energy source, and thus affects the dynamical evolution of globular clusters by slowing down the evolution rate and extending the core collapse time Tcc. And the dynamical length scale $$R_c, $$R_h is also extended. This represents the expansion of cluster due to the stellar mass loss.

  • PDF

The Identification of Rigid Body Properties with Improved Mass-Lines from Impact Hammer Tests of The Mounted Structure (탄성지지된 구조물의 충격 햄머 실험에서 질량선의 개선을 통한 향상된 강체 특성 규명법)

  • Ahn, Se-Jin;Jeong, Weui-Bong;Hwang, Dae-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.336.2-336
    • /
    • 2002
  • There are many researches to identify the rigid body properties from the mass-line obtained by impact hammer testing. The correct rigid body properties of the structure may be estimated if the mass-line of the structure could be obtained exactly. When the structure is mounted by elastic materials, the mass-line cannot be read correctly from the impulse response spectrum. The reason is due to the effects of rigid body modes of mounted structure. (omitted)

  • PDF