Effect of OPU Session Periods on the Efficiency of In Vitro Embryo Production in Elite Korean Native Cow

  • Choi, Byung-Hyun;Song, Seok-Hwan;Park, Bun-Young;Kong, Rami;Son, Mi-Ju;park, Chan-Sang;Shin, Nyeon-Hak;Cheon, Hye-Young;Lee, Sung-Hoon;Jin, Jong-In;Lee, Jung-Gyu;Kong, Il-Keun
    • 한국수정란이식학회지
    • /
    • 제33권4호
    • /
    • pp.265-270
    • /
    • 2018
  • Up-to-date artificial insemination (AI) using frozen sperm consider as the most widely using technology for improvement of Korean Native Cow (Hanwoo) embryo production. However, it is time consuming, required at least 15~20 years to make more than 6 generations, and their offspring number is limited. To overcome such limitations, superovulation and in vitro fertilization have been developed. For superovulation, the number of produced embryos are not enough for commercialization and donor cows need rest period. This led to use of slaughterhouse ovary for in vitro fertilization, but it is impossible to repeat the collection from the same individual and it only can improve the genetic merits of offspring for one generation. Production of embryos using Ovum Pick-Up (OPU) technique, where oocytes can be repeatedly collected from living elite donor, might overcome these limitations. In this study, we investigated the possibility of using OPU technique from donors at different age and different session periods for mass-embryo-production. Oocytes were collected from 26 donor cows twice per week, 3 - 4 months per year, between 2013 and 2016. Results showed that, the average number of embryo produced in first year used donor was significantly higher than that in second year used donor ($3.89{\pm}2.85$ vs $3.29{\pm}2.70$), however, there was no significant difference between third year used donor ($3.51{\pm}3.32$) and other groups. Taken together, our data showed that repeated using of donor up to three years is possible for in vitro embryo mass-production. Moreover, OPU can be used as suitable embryo producing technique for livestock breed improvement.

막냉각되는 원봉 표면에의 물질전달에 관한 실험적 연구 (Experimental Study of Mass Transfer on a Film Cooled Cirular Cylinder Surface)

  • 이준식;이택식;이상우
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1756-1762
    • /
    • 1991
  • 본 연구에서는 막냉각되는 터빈블레이드에서의 열전달 계수를 측정하기 위하 여 열전달과 물질전달의 상사관계를 이용하였다.터빈블레이드의 선단을 다른 연구 에서와 마찬가지로 원봉으로 모사하였고, 원봉의 표면에 위치하고 있는 1열의 분사홀 로부터 제트가 분사될 때 분사홀 근처 및 그 하류에서의 물질 전달계수를 측정하기 위 해 나프탈렌승화법을 이용하였다. 분사홀 열의 위치를 정체점에서 하류방향으로 이 동시키면서, 물질전달계수의 변화를 연구하였고, 분사율(M=.rho.$_{j}$ U$_{j}$ /.rho.$_{\infty}$ U$_{\infty}$)의 영향도 고찰하였다.

원형 및 사각단면의 미세채널내 흐름응축 열전달 연구 (A Study of Flow Condensation Inside Mini-Channels with Circular and Rectangular Cross Section)

  • 신정섭;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1458-1463
    • /
    • 2004
  • By using unique experimental techniques and careful construction of the experimental apparatus, the characteristics of the local heat transfer were investigated using the condensing R134a two-phase flow, in horizontal single mini-channels. The circular channels ($D_h=0.493$, 0.691, and 1.067 mm) and rectangular channels ($D_h=0.494$, 0.658, and 0.972 mm) were tested and compared. Tests were performed for a mass flux of 100, 200, 400, and 600 $kg/m^2s$, a heat flux of 5 to 20 $kW/m^2$, and a saturation temperature of $40^{\circ}C$. In this study, effect of heat flux, mass flux, vapor qualities, hydraulic diameter, and channel geometry on flow condensation were investigated and the experimental local condensation heat transfer coefficients are shown. The experimental data of condensation Nusselt number are compared with existing correlations.

  • PDF

오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 열전달에 관한 실험적 연구 (Study on Evaporation Heat Transfer of R-l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger)

  • 박재홍;김영수
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.845-854
    • /
    • 2004
  • The evaporation heat transfer coefficient for R-l34a, R-407C (a mixture of 23wt% R-32, 25 wt% R-125, and 52 wt% R-l34a) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) flowing in the oblong shell and plate heat exchanger were investigated experimentally in this study. Four vertical counterflow channels were formed in the exchanger by four plates of commercial geometry with a corrugated sinusoid shape of a chevron angle of 45 degree. The effects of the mean vapor quality, mass flux, heat flux, and saturation temperature of different refrigerants on the evaporation heat transfer were explored in detail. Similar to the case of a Plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. It is found that the evaporation heat transfer coefficient in the plates is much higher than that in circular pipes. The present data show that the evaporation heat transfer coefficients of all refrigerants increase with the vapor quality. At a higher mass flux h, is higher than for the entire range of the vapor quality. Raising the imposed wall heat flux was found to slightly improve h$_{r}$, while h$_{r}$ is found to be lower at a higher refrigerant saturation temperature. A comparison of the performance of the various refrigerants reveals that R-410A has the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. Based on the present data, empirical correlations of the evaporation heat transfer coefficient were proposed.sed.

수직 액막형 흡수기의 흡수성능 변화에 미치는 냉각수 유량의 영향 (Effect of the Flow Rate of Coolant on the Absorption Peformance of a Vertical Absorber)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.410-417
    • /
    • 2006
  • The present study predicted the effect of the flow rate of coolant on the absorption performance of a vertical falling film type absorber Heat and mass transfer peformances were numerically investigated. The exit temperatures of solution and coolant were decreased as the flow rate of the coolant was increased at the film Reynolds number of 100. The absorption mass flux was increased and then decreased as the distance from the inlet of the absorber was increased. The distance showing the maximum absorption mass flux was ranged from 0.3 to 0.5m. The heat flux and the absorption mass flux were increased and then slowly decreased as the flow rate of the coolant was increased. The maximum values were obtained at the flow rate of coolant of 2.0L/min.

2상 마이크로 채널 히트 싱크에서의 유동 비등 열전달에 관한 연구 (Study on flow boiling heat transfer in two-phase micro-channels heat sink)

  • 최용석;임태우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권7호
    • /
    • pp.702-708
    • /
    • 2015
  • 본 연구에서는 FC-72를 작동 유체로 사용하여 이상 유동 비등에 관한 실험을 수행하였다. 마이크로 채널은 깊이 0.2mm, 폭 0.45mm, 길이 60mm 그리고 채널의 개수는 15개로 구성되었다. 실험은 질량유속과 열유속 각각 $200-400kg/m^2s$, $5.6-49.0kW/m^2$ 범위와 증기 건도 0.02-0.93 범위에서 수행되었다. 실험 결과에 따르면 낮은 건도(x<0.2)영역에서는 핵비등에 의한 열전달이 지배적으로 작용하며, 그 이상의 증기 건도 영역에서는 핵비등과 강제 대류 비등의 영향이 복합적으로 작용하는 것으로 나타났다. 핵비등과 강제 대류 비등은 각각 비등수와 대류수에 관한 함수로 표현할 수 있으며, 실험에서 얻어진 열전달 계수는 기존의 상관식에 의한 열전달 계수와 비교하였다.

진동형 히트 파이프에서 튜브의 지름과 개수에 따른 전산 열유동해석 (COMPUTATIONAL ANALYSIS OF THERMAL FLOW WITH VARYING THE DIAMETER AND THE NUMBER OF TUBES IN PULSATING HEAT PIPES)

  • 한성현;최종욱;김성초
    • 한국전산유체공학회지
    • /
    • 제21권1호
    • /
    • pp.86-93
    • /
    • 2016
  • In this paper, heat transfer characteristics of pulsating heat pipes are investigated with the diameter and the number of tubes through the computational analysis of thermal flow. The numerical simulation includes the phase change precess with VOF model using OpenFOAM software. The numerical code is modified for the phase change to occur with saturation temperature. The numerical results are compared with the previous ones to validate the present code. The resonable results have been obtained based on the mass transfer time relaxation parameter considering the density ratio. When the ratio of length to diameter and the number of tubes are on the decrease, the thermal resistances also tends to decrease in the pulsating heat pipes. These numerical results will supply the base line data to design and to manufacture the pulsating heat pipe.

Heat Transfer Characteristics of Liquid-Solid Suspension Flow in a Horizontal Pipe

  • Ku, Jae-Hyun;Cho, Hyun-Ho;Koo, Jeong-Hwan;Yoon, Suk-Goo;Lee, Jae-Keun
    • Journal of Mechanical Science and Technology
    • /
    • 제14권10호
    • /
    • pp.1159-1167
    • /
    • 2000
  • Particles in liquid-solid suspension flow might enhance or suppress the rate of heat transfer and turbulence depending on their size and concentration. The heat transfer characteristics of liquid-solid suspension in turbulent flow are not well understood due to the complexibility of interaction between solid particles and turbulence of the carrier fluid. In this study, the heat transfer coefficients of liquid-solid mixtures are investigated using a double pipe heat exchanger with suspension flows in the inner pipe. Experiments are carried out using spherical fly ash particles with mass median diameter ranging from 4 to $78{\mu}m$. The volume concentration of solids in the slurry ranged from 0 to 50% and Reynolds number ranged from 4,000 to 11,000. The heat transfer coefficient of liquid-solid suspension to water flow is found to increase with decreasing particle diameter. The heat transfer coefficient increases with particle volume concentration exhibiting the highest heat transfer enhancement at the 3% solid volume concentration and then gradually decreases. A correlation for heat transfer to liquid-solid flows in a horizontal pipe is presented.

  • PDF

Free vibration analysis of asymmetric shear wall-frame buildings using modified finite element-transfer matrix method

  • Bozdogan, Kanat B.
    • Structural Engineering and Mechanics
    • /
    • 제46권1호
    • /
    • pp.1-17
    • /
    • 2013
  • In this study, the modified finite element- transfer matrix methods are proposed for free vibration analysis of asymmetric structures, the bearing system of which consists of shear wall-frames. In the study, a multi-storey structure is divided into as many elements as the number of storeys and storey masses are influenced as separated at alignments of storeys. The shear walls and frames are assumed to be flexural and shear cantilever beam structures. The storey stiffness matrix is obtained by formulating the governing equation at the center of mass for the shear walls and the frames in the i.th floor. The system transfer matrix is constructed in the dimension of $6{\times}6$ by transforming the obtained stiffness matrix. Thus, the dimension, which is $12n{\times}12n$ in classical finite elements, is reduced to the dimension of $6{\times}6$. To study the suitability of the method, the results are assessed by solving two examples taken from the literature.

저온 수직평판에서 착상에 대한 운전조건의 영향 (The Effect of Operating Conditions on the Frost Formation in a Vertical Plate at a Low Temperature)

  • 이관수;이태희;김우승
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3305-3314
    • /
    • 1994
  • In this study, the influence of a frost formed on the vertical plate for different operating conditions(the temperature of the air, the humidity of the air, the velocity of the air, and the temperature of the cooling plate) is investigated. The performance of the heat exchanger is examined by introducing a parameter such as the energy transfer resistance. Correlations which relate frost density, frost thickness and energy transfer resistance to Reynolds number, air temperature and humidity, and cooling plate temperature are developed. Static pressure drop and air flow rate are expressed as a function of free flow area of air.