• 제목/요약/키워드: Mass Flux Ratio

검색결과 114건 처리시간 0.027초

열적 메커니즘에 의한 펄스레이저 어블레이션 현상의 수치계산 (Numerical computation of pulsed laser ablation phenomena by thermal mechanisms)

  • 오부국;김동식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1572-1577
    • /
    • 2003
  • High-power pulsed laser ablation under atmospheric pressure is studied utilizing numerical and experimental methods with emphasis on recondensation ratio, and the dynamics of the laser induced vapor flow. In the numerical calculation, the temperature pressure, density and vaporization flux on a solid substrate are first obtained by a heat-transfer computation code based on the enthalpy method, and then the plume dynamics is calculated by using a commercial CFD package. To confirm the computation results, the probe beam deflection technique was utilized for measuring the propagation of a laser induced shock wave. Discontinuities of properties and velocity over the Knudsen layer were investigated. Related with the analysis of the jump condition, the effect of the recondesation ratio on the plume dynamics was examined by comparing the pressure, density, and mass fraction of ablated aluminum vapor. To consider the effect of mass transfer between the ablation plume and air, unlike the most previous investigations, the equation of species conservation is simultaneously solved with the Euler equations. Therefore the numerical model computes not only the propagation of the shock front but also the distribution of the aluminum vapor. To our knowledge, this is the first work that employed a commercial CFD code in the calculation of pulsed ablation phenomena.

  • PDF

납작관의 종횡비가 R-410A 증발열전달 및 압력손실에 미치는 영향 (Effect of Aspect Ratio of Flat Tube on R410A Evaporation Heat Transfer and Pressure Drop)

  • 김내현;이을종;변호원
    • 대한기계학회논문집B
    • /
    • 제37권4호
    • /
    • pp.395-404
    • /
    • 2013
  • 본 연구에서는 내경 5.0mm 원관을 납작하게 한 납작관에 대하여 R-410A를 사용하여 증발열전달 실험을 수행하였다. 실험은 포화온도를 $15^{\circ}C$로 고정한 상태에서 열유속을 $5{\sim}15kW/m^2$, 질량유속을 $200{\sim}400kg/m^2s$로 변화시키며 수행되었다. 실험결과 납작관의 종횡비가 증가할수록 열전달계수와 압력손실 모두 증가하였는데 특히 종횡비 4 인 경우 증가폭이 현저하였다. 납작관의 실험결과를 기존 상관식들과 비교한 결과 열전달계수는 Shah 상관식, 마찰계수는 Jung and Radermacher 상관식이 적절히 예측하였다.

종횡비가 다른 납작관 내 응축열전달 및 압력손실 (Condensation Heat Transfer and Pressure Drop in Flat Tubes with Different Aspect Ratios)

  • 김내현;박지훈;차상진
    • 대한기계학회논문집B
    • /
    • 제34권12호
    • /
    • pp.1111-1119
    • /
    • 2010
  • 본 연구에서는 내경 5.0mm 원관을 납작하게 한 납작관에 대하여 R-410A 를 사용하여 응축열전달 실험을 수행하였다. 실험은 포화온도와 열유속을 각각 $45^{\circ}C$ 와 10kW/$m^2$으로 고정한 상태에서 질량유속과 건도를 변화시키며 수행되었다. 실험결과 납작관의 종횡비가 열전달계수에 미치는 영향은 유동양식에 따라 달리 나타났다. 환상류에서는 종횡비가 증가할수록 증가하고 성층류에서는 종횡비가 증가할수록 감소하였다. 한편 납작관의 마찰손실은 종횡비가 증가할수록 증가하였다. 기존 상관식들은 납작관의 열전달계수와 마찰계수를 적절히 예측하였다.

Multiple-Hole Effect on the Performance of a Sparger During Direct Contact Condensation of Steam

  • Seok Cho;Song, Chul-Hwa;Chung, Heung-June;Chun, Se-Young;Chung, Moon-Ki
    • Journal of Mechanical Science and Technology
    • /
    • 제15권4호
    • /
    • pp.482-491
    • /
    • 2001
  • An experimental study has been carried out to investigate an I-type sparger-performance in view of pressure oscillation and thermal mixing in a pool. Its pitch-to-hole diameter, P/D, varies from 2 to 5. The test conditions are restricted to the condensation oscillation regime. In the present study, two different hole patterns, staggered and parallel types, are employed under various test conditions. The amplitude of the pressure pulse shows a peak for pool temperatures of 45∼85$\^{C}$, which depends on P/D and the steam mass flux. The effect of hole pattern on the pressure load is smaller than that of P/D. The dominant frequency increases with the subcooling temperature of pool water and P/D. A correlation for the dominant frequency is proposed in terms of the pitch-to-hole diameter ratio and other dimensionless thermal hydraulic parameters.

  • PDF

질량분석법에 의한 내분비계 장애물질의 분석과 막 여과에 의한 제거 (Analysis of EDCs by Mass Spectrometry and their Removal by Membrane Filtrations)

  • 김태욱;연경호;조재원;문승현
    • 멤브레인
    • /
    • 제15권4호
    • /
    • pp.297-309
    • /
    • 2005
  • 다수의 잠재적인 내분비계장애물질이 환경에 방출됨으로써 새로운 환경문제로 세계적 관심이 모아지고 있다. 이러한 물질들을 측정하고 감시하기 위한 고감도이며 신뢰성 있는 분석방법의 개발이 필수적이다. 이 연구에서는 기체크 로마토그래피 질량분석법과 액체크로마토그래피 질량분석법이 내분비계장애물질들의 분석을 위해 이용되었으며 두 가지 분석방법들이 DEHP, BBP, PCP, BPA에 대해 비교 및 평가되었다 그 결과 액체크로마토그래피 질량분석법이 더 낮은 검출 한계를 나타내는 것으로 조사되었다. 또한 액체크로마토그래피 질량분석법은 대부분의 순수한 분자들로서 내분비계장애물질들을 측정 가능함이 판명되었다. 이 연구에서는 음용수에서 내분비계장애물질들을 제거하는 방법으로 유기막과 세라믹막을 제시하였으며 십자류 나노여과 방식이 내분비계장애물질들을 $100\%$ 제거하는 것으로 조사되었고 분획분자량 250 나노여과는 내분비계장애물질을 제거함에 있어 효과적인 것으로 판명되었다. 나노여과, 고속한외여과, 저속한외여과의 투과플럭스와 물질전달계수와의 비는 0.67, 3.4, 그리고 0.44였으며 나노여과와 저속한외여과는 확산이 주요한 조건에서 운전되며 고속한외여과는 대류가 주요한 조건에서 운전된다. 더욱이, 확산이 주요한 나노여과와 저속한외여과에서 내분비계장애물질의 제거율이 높은 것으로 측정되었다. 한외여과에 의한 제거는 내분비계장애물질들의 분자량에 의존하는 것으로 조사되었으며 내분비계장애물질들은 확산이 주요한 수리동역학적 조건에서 제거됨이 판명되었다.

150kW 아크제트 유동의 엔탈피 결정 (Determination of Enthalpy in the 150kW Arc-Jet)

  • 나재정;이정민
    • 한국항공우주학회지
    • /
    • 제41권7호
    • /
    • pp.547-551
    • /
    • 2013
  • 아크제트 유동에서 질량평균 및 중심영역 엔탈피 값을 실험적으로 구하였다. 실험에 사용된 아크제트는 150kW 휼스형으로 가스터빈 엔진 분출냉각 기술 연구를 위한 실험조건을 적용하였다. 질량평균 엔탈피 값은 5.5MJ/kg로 음속목유동 방법을 적용하여 구하였다. 중심영역 엔탈피 값은 14.3MJ/kg으로 열전달 방법을 적용하여 구하였다. 실험결과 아크제트 유동에서 중심영역 대비 질량평균 엔탈피 값의 비는 2.6으로 나타났다.

A STUDY OF LYNDS 1251 DARK CLOUD: II. INFRARED PROPERTIES

  • LEE YOUNGUNG
    • 천문학회지
    • /
    • 제29권2호
    • /
    • pp.107-117
    • /
    • 1996
  • We have studied the star forming activities and dust properties of Lynds 1251, a dark cloud located at relatively high galactic latitude. Eleven IRAS point sources identified toward Lynds 1251 are discussed. Estimate of stellar masses, and far-infrared lumnosities of the young stars associated with two prominent IRAS point sources imply that these are T-Tauri stars with masses smaller than $0.3 M_\bigodot$. The low dust temperature of 27 K and low ratio of FIR emission to hydrogen column density are probably due to the lack of internal heating sources. Presumably two low mass young stars do not have enough energy to heat up the dust and gas associated. The dust heating is dominated by the interstellar heating source, and the weaker interstellar radiation field can explain the exceptionally low dust temperatures found in Lynds 1251. The estimated dust mass of Lynds 1251 is just $\~1M_\bigodot$, or about 1/1000 of gas mass, which implies that there must be a substantial amount of colder dust. The infrared flux at $100{\mu}m$ is matching well with $^{13}CO$ peak temperature, while the $^{12}CO$ integrated intensity is matching with the boundary of dust emission. Overall, the dust properties of Lynds 1251 is similar to those of normal dark clouds even though it does have star forming activities.

  • PDF

비공비 혼합냉매 R-410A를 적용한 납작한 알루미늄 마이크로 멀티 튜브에서의 마찰손실에 관한 연구 (A study on the friction head loss in flat aluminum micro multi tubes with nonazeotropic refrigerant mixtures R-410A)

  • 이정근;민경호
    • Design & Manufacturing
    • /
    • 제13권2호
    • /
    • pp.37-43
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer friction loss headby using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat enhancement factor and pressure drop penalty factor. 1) The friction head loss showed an increase as the vapor quality and mass flux increased. In case of saturation temperature, it shows an increase as it gets lower. These factors are the reason occurring as the lower the saturation temperature is, the higher the density of refrigerant vapor gets. The influence of heat flux is similar as the dryness is low, but as it gets higher, it lowers in heat flux, and as the high temperature of high heat flux, it is a factor that occurs as the density gets lower. 2) RMS error of the in case of friction head loss, it showed to be predicted as 0.45~0.67 by Chisholm, Friedel, Lockhart and Martinelli. 3) As forfriction head loss penalty factor, the smaller the aspect ratio is, the larger the penalty factor gets, and as for the effect of micro-fin, the penalty factor increased because it decreases to the gas fluid the way groove for the refrigerant's flow.

Surface properties and interception behaviors of GO-TiO2 modified PVDF hollow fiber membrane

  • Li, Dongmei;Liang, Jinling;Huang, Mingzhu;Huang, Jun;Feng, Li;Li, Shaoxiu;Zhan, Yongshi
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.113-120
    • /
    • 2019
  • To investigate surface properties and interception performances of the new modified PVDF membrane coated with Graphene Oxide (GO) and nano-$TiO_2$ (for short the modified membrane) via the interface polymerization method combined with the pumping suction filtration way, filtration experiments of the modified membrane on Humic Acid (HA) were conducted. Results showed that the contact angle (characterizing the hydrophilicity) of the modified membrane decreased from $80.6{\pm}1.8^{\circ}$ to $38.6{\pm}1.2^{\circ}$. The F element of PVDF membrane surface decreased from 60.91% to 17.79% after covered with GO and $TiO_2$. O/C element mass ratio has a fivefold increase, the percentage of O element on the modified membrane surface increased from 3.83 wt% to 20.87%. The modified membrane surface was packed with hydrophilic polar groups (like -COOH, -OH, C-O, C=O, N-H) and a functional hydrophilic GO-polyamide-$TiO_2$ composite configuration. This configuration provided a rigid network structure for the firm attachment of GO and $TiO_2$ on the surface of the membrane and for a higher flux as well. The total flux attenuation rate of the modified membrane decreased to 35.6% while 51.2% for the original one. The irreversible attenuation rate has dropped 71%. The static interception amount of HA on the modified membrane was $158.6mg/m^2$, a half of that of the original one ($295.0mg/m^2$). The flux recovery rate was increased by 50%. The interception rate of the modified membrane on HA increased by 12% approximately and its filtration cycle was 2-3 times of that of the original membrane.

포화상태에 놓인 C-Type 액체수소 탱크의 슬로싱이 열 유속과 BOG에 미치는 변화의 수치적 분석 (Numerical Study of Heat Flux and BOG in C-Type Liquefied Hydrogen Tank under Sloshing Excitation at the Saturated State)

  • 이진호;황세윤;이성제;이장현
    • 한국전산구조공학회논문집
    • /
    • 제35권5호
    • /
    • pp.299-308
    • /
    • 2022
  • 본 논문은 슬로싱 상태에 놓인 포화 상태 액체수소탱크에서 열 유속 및 BOG(Boil-off gas)의 경향을 다루고 있다. 특히, 액체-기체간의 침투 및 혼합에 의한 열 교환에 관심을 두었다. 먼저, VOF(Volume of fluid)와 Eulerian 기반의 다상 유동모델로 모형 슬로싱 실험을 모사하여 압력을 예측하고 계측된 값과 비교하였다. 자유 수면 및 충격 압력 실험 결과와 해석 결과를 비교하였으며, 유체의 속도 예측에서 정확할 수 있음을 간접적으로 증명하였다. 그리고 2차원의 Type-C 원통형 수소탱크를 대상으로 다상열유동해석을 수행하였다. 이때 포화상태에 놓인 액체 및 기체수소를 가정하고, 해석을 통해 각 상간의 혼합에 의한 열 교환의 수준을 확인하고자 하였다. 단, 상간의 열 교환만을 관심으로 두고 있었으므로 질량전달 및 기화모델은 해석에서 제외하였다. 최종적으로 상의 혼합으로 인해 액체수소로 유입되는 열 유속의 기여도에 대하여 정리하였다. 또한 액체수소로 유입되는 열 유속과 집중 질량 기반의 간이식을 통해 BOG 발생량 및 경향을 예측하고 분석하였다.