• 제목/요약/키워드: Mass Flow Meter

검색결과 124건 처리시간 0.021초

100,000 RPM급으로 회전하는 에어공구의 성능측정에 관한 연구 (Study on Measuring the Performance of an Air Tool Operating at 100,000 RPM Class)

  • 조수용;김은종
    • 한국유체기계학회 논문집
    • /
    • 제6권3호
    • /
    • pp.44-50
    • /
    • 2003
  • An experiment is conducted for measuring the performance of an air tool, which is operated at 100,000 RPM in an unloaded state with very low torque. A 551 kPa in gauge pressure is supply to the inlet of an air tool. An experimental apparatus is developed as a friction type dynamometer. Inlet total pressure, air flow rate, rotational speed and operating force are measured simultaneously. Torque, output power and specific output power are obtained with different rotational speeds. Those are compared with the experimental results which were obtained by a commercial dynamometer. However, no commercial dynamometers are available for measuring the torque above 30,000 RPM. In order to reduce the rotational speed, a reduction gear is applied between the air tool and the commercial dynamometer. Torque and power obtained by the commercial dynamometer show $55\%$ lower than those obtained by the developed friction type dynamometer, because the mass is added to the rotor of air tool for the braking system of the commercial dynamometer and power loss is generated by the reduction gear. From the compared results, the friction type dynamometer should be applied for measuring the performance of the air tool operating at low torque and high RPM.

OHC형 캠-밸브 기구의 최적 캠 형상설계 및 실험적 검증 (Optimum Cam Profile Design and Experimental Verification on an OHC Type Cam-valve System)

  • 김성훈;김원경;박윤식
    • 대한기계학회논문집
    • /
    • 제16권11호
    • /
    • pp.2049-2058
    • /
    • 1992
  • 본 연구에서는 OHC형 캠-밸브 기구의 6자유도 집중 질량계 모델을 기본으로 하고, 밸브변위와 선회종동자(oscillating-follower or finger-follower)의 동적 스트 레인을 측정하여 모델의 타당성을 검증하고, 또 최적화 기법을 도입하여 밸브 개폐시 기, 밸브변위 그리고 최소 접촉력 등을 구속조건으로 주고 캠과 종동자 사이의 최대 접촉력을 최소화 시키도록 최적 캠 형상을 설계하였다. 그리고 설계된 캠을 정밀 가 공하여 최적화 설계의 타당성 및 접촉력을 실험을 통하여 검증하였다.

실험계획법을 이용한 초고속 스핀들의 언클램핑 (unclamping) 시간 저감에 대한 최적 조건에 관한 연구 (A Study on the Reduction of Unclamping Time by Design of Experiments)

  • 정원지;조영덕;이춘만;정동원;송태진
    • 한국공작기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.1-7
    • /
    • 2006
  • By the reason of increased demand of high productivity, the researches on manufacturing process and equipments for reducing cycle time have been made in many directions of a machine tool industries. Especially high productivity is very important to machining center with high-speed spindle. This paper proposed method of reducing T-T(tool to tool) time which results in shorter unclamping time. T-T time varies as factors such as a hydraulic system, a drawbar mass, a flow meter, a disc spring, piston and pipe diameters. In this paper We could find design factors has much influence on decreasing the unclamping time using DOE(Design of Experiment) and optimized the level of the factors using AMESim $4.0^{(R)}$ and visualNastran $4D^{(R)}$ Finally, we have verified improved result of the optimized factors with initial design.

수용액 분사에 의한 아이스 슬러리의 제조에 관한 실험적 연구 (An experimental study on ice slurry creation by injection of an aqueous solution)

  • 이용구;오철
    • 한국항해항만학회지
    • /
    • 제34권1호
    • /
    • pp.71-75
    • /
    • 2010
  • 아이스슬러리의 생성을 위하여 냉각평판에 작동수를 분사하는 실험을 수행하여 그에 대한 영향에 대하여 영향을 평가하였다. 실험에 사용된 에틸렌글리콜 수용액은 10~20wt%의 수용액을 사용하였다. 실험장치는 슬러리아이스 저장탱크, 브라인 탱크, 브라인 순환장치, 유량계 및 온도기록계로 구성되어 있다. 실험조건은 평균유속 1.0~2.0m/s, 냉각온도 $-17{\sim}-10^{\circ}C$의 조건 하에 실험을 수행하였다.

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.

수리역학적 상호작용을 고려한 균열암반매질에서의 수리학적 거동에 대한 수치적 연구 (A Numerical Study on Hydraulic Behavior in a Fractured Rock Medium with Hydromechanical Interaction)

  • 정우창;박영진
    • 한국지반환경공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.61-68
    • /
    • 2009
  • 본 논문은 수리학적 현장 주입시험 기간 동안 고려될 필요가 있는 수리역학적 상호작용에 따른 균열암반매질의 수리학적 거동에 대한 수치적 연구이다. 이러한 주입시험은 굴착정 내에 설치된 개구간(open hole section)을 따라 높은 압력을 가진 유량을 주입하며, 이를 통해 굴착정을 가로지르는 균열로부터 유량을 측정하는 것이다. 시간에 따라 변화되는 유량측정결과는 수리역학적 상호작용에 대한 분석 및 예측을 위해 개발된 수치모형의 현장 적용성을 평가하기 위해 사용되었다. 유량측정결과 전도성이 있는 균열들은 상호의존적인 균열망을 형성하며, 이로 인해 균열망을 구성하는 개별적인 균열요소들은 독립적인 시스템으로서 적절하게 모형화 될 수 없음을 보여주었다. 또한 간극수압이 굴착정 주위에 작용하는 최소주응력을 초과할 때 새로운 유체유입영역이 발생되며, 이러한 최소주응력보다 훨씬 큰 간극수압은 굴착정 주위의 균열들에 의해 유지될 수 있다는 것을 보여주었다. 본 연구에서 이러한 특성들이 자연 상태의 균열망의 구성형태에 따라 어떻게 영향을 미치게 되는지 이산 균열망 모형을 통해 수치적으로 분석되었다.

  • PDF

내경 4.57과 7.75 mm인 수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in Horizontal Tubes with Inner Diameter of 4.57 mm and 7.75 mm)

  • 손창효
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.30-37
    • /
    • 2008
  • The evaporation pressure drop of $CO_2$ (R-744) in horizontal tubes was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 and 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The pressure drop measured during the evaporation process of $CO_2$ increases with increased mass flux, and decreases as the saturation temperature increased. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

수평원관내 $CO_2$의 증발열전달 (Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube)

  • 경남수;장승일;최선묵;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers)

  • 손창효;오후규
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

미세채널 내 이산화탄소의 증발 열전달 특성 및 오일의 영향에 관한 실험적 연구 (Experimental Study on Characteristics of Evaporation Heat Transfer and Oil Effect of $CO_2$ in Mini-channels)

  • 이상재;김대훈;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.16-22
    • /
    • 2009
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a mini-channels were performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($300{\sim}800kg/m^{2}s$), heat fluxes($10{\sim}40kW/m^2$) saturation temperatures($-5{\sim}5^{\circ}C$), and PAG oil concentration(0, 3, 5wt%). The variation of the heat transfer coefficient was different according to the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.