• Title/Summary/Keyword: Mass Flow

Search Result 3,820, Processing Time 0.031 seconds

An Experimental Study on the Characteristics of Temperature Separation for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브에서의 형상 변화에 따른 온도 분리에 관한 실험적 연구(I))

  • 황승식;전운학;김종철;이희상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial temperature distribution and the radial temperature distribution in internal space of a tube. From the study, following conclusive remarks can be made. Average flow rate that flows into a tube is in proportion to square root of inlet pressure. As inlet pressure increases axial and radial temperature distribution in the inner space of vortex-tube increase. As mass flow rate ratio change, separation point moves.

  • PDF

Oxygen Transfer Characteristics of an Ejector Aeration System

  • Yang, Hei-Cheon;Park, Sang-Kyoo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.1
    • /
    • pp.10-17
    • /
    • 2012
  • The objective of this study was to investigate the oxygen transfer characteristics of an ejector aeration system. In order to evaluate the oxygen transfer performance of the ejector aeration system, a comparative experiment was conducted on a conventional blower aeration system. The effect of entrained air flow rate and aerating water temperature on the oxygen transfer efficiency was investigated. The dissolved oxygen concentration increased with increasing entrained air flow rate, but decreased with increasing aerating water temperature for two aeration systems. The volumetric mass transfer coefficient increased with increasing entrained air flow rate and with increasing aerating water temperature for both aeration systems. The average mass transfer coefficient for the ejector aeration system was about 20% and 42% higher than that of the blower aeration system within the experimental range of entrained air flow rates and aerating water temperatures.

Performance Prediction of a Gas Turbine Using CO2 as Working Fluid (CO2를 작동유체로 하는 가스터빈의 성능예측)

  • Yang, Hyun-Jun;Kang, Do-Won;Lee, Jong-Jun;Kim, Tong-Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • This study investigated the changes in performance and operating characteristics of an F-class gas turbine according to the change of working fluid from air to carbon dioxide. The revised gas turbine is the topping cycle of the semi-closed oxy-fuel combustion combined cycle. With the same turbine inlet temperature, the $CO_2$ gas turbine is expected to produce about 85% more power. The main contributor is the greater compressor mass flow and the added oxygen flow for the combustion. Compressor pressure ratio increases about 50%. However, the gas turbine efficiency reduces about 10 %. Modulation of inlet guide vane to reduce the compressor inlet mass flow, the major purpose of which is to reduce the compressor inlet Mach number, was also performed.

Study on the Flow and Mass Transfer in a PASB Arc Plasma Chamber (PASB 아크 플라즈마 챔버에서 발생하는 유동 및 물질전달에 관한 연구)

  • Lee, Jong-Chul;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.4
    • /
    • pp.7-13
    • /
    • 2008
  • The computational investigation is performed to find out the interaction of arc plasmas with surrounding materials and the thermal flow characteristics in a PASB (Puffer-Assisted Self-Blast) chamber, which is one of new breaking concepts in $SF_6$ switchgears. It is very important to define the flow and mass transfer happened during the full arcing history for further understanding complex physics inside the chamber. In this study, we have considered two diffusion processes by the hot arc plasma, one is PTFE nozzle ablation and the other is Cu electrode evaporation, simultaneously. It was found that the principle of the pressure-rise inside the chamber is confirmed by the computational results and the increase of the electrical conductivity of the residual gas near current zero is critical to the chamber design.

Numerical Analysis on Effects of Free-Stream Turbulence Intensity on the Three-dimensional Turbulent Flow Characteristics in a Turbine Cascade (자유유동 난류강도가 터빈 캐스케이드내 3차원 난류유동 특성에 미치는 영향에 관한 전산해석)

  • Yoon, Deok-Kyu;Lee, Wu-Sang;Kim, Dae-Hyun;Chung, Jin-Taek
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.371-374
    • /
    • 2006
  • The objective of this study is to determine the influence of free-stream turbulent intensity on the three-dimensional turbulent flow in a linear turbine cascade. The range of free-stream turbulence intensity considered is 0.7~10%. This study was performed numerically. The results show that the mass averaged loss coefficient increased according to the increase of free-stream turbulence intensity due to increased value of the mass averaged total pressure loss coefficient which was higher than the decreased value of the mass averaged secondary flow loss coefficient. The loss coefficient distribution was changed suddenly at a free-stream turbulence intensity of 10% while the loss coefficient distribution was rarely changed at a lower free-stream turbulence intensity of 5%.

  • PDF

Numerical Evaluation of Dynamic Transfer Matrix and Unsteady Cavitation Characteristics of an Inducer

  • Yonezawa, Koichi;Aono, Jun;Kang, Donghyuk;Horiguchi, Hironori;Kawata, Yutaka;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.3
    • /
    • pp.126-133
    • /
    • 2012
  • The transfer matrix and unsteady cavitation characteristics, cavitation compliance and mass flow gain factor, of cavitating inducer were evaluated by CFD using commercial software. Quasi-steady values of cavitation compliance and mass flow gain factor were obtained first by using steady calculations at various flow rate and inlet cavitation number. Then unsteady calculations were made to determine the transfer matrix and the cavitation characteristics. The results are compared with experiments to show the validity of calculations.

Hydrodynamic Mass and Damping of Tube Bundles in Two-Phase Cross-Flow (2상 횡유동을 받는 튜브집합체의 추가질량과 감쇠)

  • 김범식;손갑헌;김병구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.6
    • /
    • pp.1128-1146
    • /
    • 1989
  • 본 논문에서는 2상 횡유동의 진동 메카니즘을 규명하기 위한 실험계획의 일환으로 실시된 실험으로 부터 튜브집합체의 추가질량(hydrodynamic mass)과 감쇠 (damping)에 대해 고찰하였다. 실험은 튜브배열과 피치 대 직경비(pitch-over-di- ameter:.rho./d)가 상이한 튜브집합체에 대해 2상 유체를 모의한 공기-물(air-water) 혼합물에서 수행하였다. 액체상태로부터 99%의 보이드율까지 변화된 2상 유체의 유량은 튜브가 유체탄성 불안정성 (fluidelastic instability)에 도달할 때까지 점진적으로 증가하였다.

Performance Test for a Centrifugal Air Compressor (원심형 공기압축기 성능시험)

  • 신유환;안이기;김광호;손병진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1964-1971
    • /
    • 1995
  • In the present study, the performance characteristics of a centrifugal air compressor were investigated experimentally. The PC controlled performance test facility for a centrifugal air compressor driven by an electric motor with a gear box to achieve higher compressor rotating speed was set up in the present study. The performance test for a turbocharger compressor of a diesel engine was conducted, and in a case of 34,800 rpm, pressure ratio 1.18, flow rate 0.09kg/s, compressor efficiency 61% were investigated. Adiabatic power for a tested compressor showed maximum value at mass flow ratio 0.8. The value of mass flow ratio of maximum efficiency was about 0.37, it was independent of compressor rotating speed.

Water Masses and Flow Fields of the Southern Ocean Measured by Autonomous Profiling Floats (Argo floats)

  • Park, Young-Gyu;Oh, Kyung-Hee;Suk, Moon-Sik
    • Ocean and Polar Research
    • /
    • v.27 no.2
    • /
    • pp.183-188
    • /
    • 2005
  • Using data from Argo floats collected in the Southern Ocean, we describe water mass prop erties and flow fields at intermediate levels (1000m and 2000m levels). Water mass properties from Argo floats, which are consistent with those from previous hydrographic surveys, reflect the movement of the floats well even without quality control on the Argo data. Since the flow fields from the Argo floats do not cover the entire Southern Ocean, we could not obtain a general circulation pattern, especially at the 2000m level. We, however, can confirm the general eastward tendency due to ACC largely following the topography.

Optimum Design of Surface Aerator Using Response Surface Method (반응표면 기법을 이용한 생물반응조 표면포기기 최적설계)

  • Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.47-55
    • /
    • 2010
  • In this study, we optimized the shape of the surface aerator that will be installed in a biological reactor using the response surface method. Response surfaces of mass flow rate, impeller torque, mass flow rate per impeller torque are generated and used to track the optimum shape of the aerator. MOGA(Multi-Objective Genetic Algorithm)method is adopted to find the optimum results. By increasing the mass flow rate per impeller torque, increase of oxygen supply efficiency to a reactor is anticipated. To verify the usability of the surface aerator, PIV measurements on flow fields inside a scale-downed biological reactor model are carried out.