New Wall Impaction Model for Diesel Spray (디젤분무의 새로운 벽면충돌모델)

  • Park K.
    • Journal of computational fluids engineering
    • /
    • v.2 no.2
    • /
    • pp.80-88
    • /
    • 1997
  • A new wall impaction model for diesel spray is described in this paper. The gas phase is modelled in terms of the Eulerian continuum conservation equations of mass, momentum, energy and fuel vapour fraction. The liquid phase is modelled following the discrete droplet model approach. The droplet parcel contains many thousands of drops assumed to have the same size, temperature and velocity components. The droplet parcel equations of trajectory, momentum, mass and energy are written in Lagrangian form. The new drop-wall interaction model is proposed, which is based on experimental investigations on individual drops, and it is applied for the general non-orthogonal grid. The model is then assessed through comparison with experiments over a wide range of test conditions of sprays. The results are in good agreement with experimental data.

  • PDF

Numerical Simulation of a Reciprocating Compressor (왕복동 압축기의 성능해석 시뮬레이션)

  • 김정우;김현진;박희용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.475-483
    • /
    • 1993
  • A computer simulation model of a hermetic reciprocating type of refrigeration compressor has been developed. The compressor simulation model constitutes 6 control volumes, to each of which conservation laws of mass and energy are applied to yield full description of the refrigerant state along its passage. Instead of ideal gas assumption. real gas equation is employed. Some of valve-related input data required for the simulation are acquired from test bench experiments. The refrigerant states such as pressure and temperature, etc., mass flow rates, and valve motions can be predicted by the simulation. The calculated P-V diagram shows a good agreement with experimental result.

Performance Analysis for CO2 System with Sub-cooling loop (과냉 회로를 갖는 이산화탄소 냉동시스템에 대한 성능 해석)

  • Kim, Jin-Man;Ko, Sung-Gyu;Kim, Moo-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.723-728
    • /
    • 2007
  • In order to evaluate the performance of carbon dioxide cycle with a sub-cooling loop. a simulation system was developed to predict the steady state of $CO_2$ trans-critical cycle. Mathematical models are derived to describe the relationships between the system's coefficient of performance and other operating parameters The mathematical models are based entirely on the basic mass and energy conservation law and thermodynamic and transport properties of carbon dioxide A parametric study has been conducted in order to investigate the effect of sub-cooling loop and various operating conditions on the cycle performance. An optimal mass fraction of a refrigerant flowing through sub-cooling cycle existed for the given evaporating temperature, high pressure and air inlet temperature through gas cooler.

Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions (가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석)

  • 박홍희;박윤철;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF

Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber (공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법)

  • Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

NUMERICAL SOLUTION FOR WOOD DRYING ON ONE-DIMENSIONAL GRID

  • Lee, Yong-Hun;Kang, Wook;Chung, Woo-Yang
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.11 no.1
    • /
    • pp.95-105
    • /
    • 2007
  • A mathematical modeling for the drying process of hygroscopic porous media, such as wood, has been developed in the past decades. The governing equations for wood drying consist of three conservation equations with respect to the three state variables, moisture content, temperature and air density. They are involving simultaneous, highly coupled heat and mass transfer phenomena. In recent, the equations were extended to account for material heterogeneity through the density of the wood and via the density variation of the material process, capillary pressure, absolute permeability, bound water diffusivity and effective thermal conductivity. In this paper, we investigate the drying behavior for the three primary variables of the drying process in terms of control volume finite element method to the heterogeneous transport model on one-dimensional grid.

  • PDF

Development and Assessment of Wall Spray Impaction Model (벽면분무충돌모델의 개발과 평가)

  • Park K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.137-142
    • /
    • 1996
  • A new wall impaction model for spray and its assessment are described in this paper. The gas phase is modelled in terms of the Eulerian continuum conservation equations of mass, momentum, energy and fuel vapour fraction. The liquid phase is modelled following the discrete droplet model approach. The droplet parcel contains many thousands of drops assumed to have the same size, temperature and velocity components. The droplet parcel equations of trajectory, momentum, mass and energy are written in Lagrangian form. The new drop-wall interaction model is proposed, which is based on experimental investigations on individual drops, and it is applied for the general non-orthogonal gird. The model is then assessed through comparison with experiments over a wide range of test conditions of sprays. The results are in good agreement with experimental data.

  • PDF

COMPUTATIONAL STUDY ON TWO DIMENSIONAL DAM BREAKING SIMULATION USING LATTICE BOLTZMANN METHOD (LBM을 이용한 Dam Breaking 수치해석 연구)

  • Jung, Rho-Taek;Hasan, Md. Kamrul
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.54-57
    • /
    • 2011
  • In this paper we present an algorithm about how to simulate two dimensional dam breaking with lattice Boltzmann method (LBM). LBM considers a typical volume element of fluid to be composed of a collection of particles that represented by a particle velocity distribution function for each fluid component at each grid point. We use the modified Lattice Boltzmann Method for incompressible fluid. This paper will represent detailed information on single phase flow which considers only the water instead of both air and water. Interface treatment and conservation of mass are the most important things in simulating free surface where the Interface is treated by mass exchange with the water region. We consider the surface tension on the interface and also bounce back boundary condition for the treatment of solid obstacles. We will compare the results of the simulation with some methods and experimental results.

  • PDF

Dynamic Analysis of Evaporator for Optimum Control in Refrigeration System (냉동사이클의 최적 제어를 위한 증발기 동특성 해석)

  • Jeong, S.K.;Hua, Li;Choi, K.H.;Yoon, J.I.;Kim, E.P.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-88
    • /
    • 2005
  • This paper presents numerical study on dynamic characteristics of evaporator to control evaporator superheat and compressor capacity with optimum condition in refrigeration system. It is very important to reduce energy consumption and to keep room temperature within a very restricted range with minimum oscillation in some special applications of the refrigeration system. Heat exchange is mainly happened in the evaporator. So, making mathematical model of evaporator and analyzing evaporator characteristics are necessary in order to control the superheat and the capacity of the system. A mathematical model based on the one dimensional partial differential equations representing mass and energy conservation and a tube-wall energy is described. A set of ordinary differential equation is formulated by integrating separately over the two regions(two-phase and vapor) generally presented in a heat exchanger.

  • PDF

Characteristics and pathogenicity of the Entomopathogenic Fungus Beauveria bassiana101AA on the silkworm (Bombyx mori) (백강균(Beauveria bassiana)101A의 특성 및 가잠(Bombyx mori)에 대한 병원성 검정)

  • 정이연;남성희;조세연
    • Journal of Sericultural and Entomological Science
    • /
    • v.42 no.2
    • /
    • pp.99-103
    • /
    • 2000
  • This study was carried out to investigate incubating characteristics, LTSEM observation, nature of a disease of infected silkworms(bombyx mori), LD$\_$50/, optimum infective condition for mass production and infection percentage(%) on conservation periods. On the V8 media, the colony was 0.5∼2.0cm/8 days in diameter and white or slighty colored with a white fluffy to powdery appearance. The conidia was subglobos in shape, zig-zag appearance, 1-celled, hyaline and 3.2$\times$2.4 ㎛ in size on the average. The conidiophore was irregular grouped, hyaline, rounded or flask-shaped. The LD$\_$50/ values of the 2nd and 4th silkworms were each other 6.6142(Log) in natural temperature and humidity (25$\^{C}$, 65%). On optimum infective condition for mass production, all of preservation time(hr.) postinoculation in 1.0$\times$10$\^$8/ conidia/㎖ was over 97% and only 20 hr in 1.0$\times$10$\^$7/ condia/㎖ was over 90%.

  • PDF