• Title/Summary/Keyword: Mas1

Search Result 410, Processing Time 0.028 seconds

Development of medication adherence scale for the elderly with chronic disease (만성질환 노인의 약물이행 측정도구 개발)

  • Kang, Sook;Kim, Jeong sun
    • 한국노년학
    • /
    • v.41 no.1
    • /
    • pp.149-168
    • /
    • 2021
  • This study was to develop the Medication Adherence Scale in Elderly (MAS-E) with chronic disease and verify its reliability and validity. The MAS-E was developed in 5 steps: Configuration of conceptual frame by content analysis, preliminary items, pilot study, reliability and validity test, and development of final MAS-E with chronic disease. The questionnaires were collected from 345 adults with one-to-one interviews. Verification of its reliability and validity was divided into two phases. Reliability was tested using Cronbach's alpha, split-halves reliability, and test-retest. For validity tests, item analysis, factor analysis, total score-factor score correlation analysis, and criterion related validity were used. The developed scale consisted of 18 items and 4 factors - remember of taking medication (2 items), expectations for drug effects (5 items), practice taking medication according to instructions (8 items), communicating with health professionals (3 items), and explained 69.7% of total variance. The scale had significantly positive correlation (r = .72, p <.001) with the Morisky Medication Adherence Scale (MMAS-8). Cronbach's alpha was .91, Guttman split half coefficient was .80, and test-retest reliability was .912. Finding suggest that the MAS-E is a suitable scale to assess the status of medication adherence in elderly with chronic disease.

Characterization of Metakaolinite with Multiple Quantum MAS NMR

  • Han, Oc-Hee;Stefan Steuernagel
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.4 no.1
    • /
    • pp.12-18
    • /
    • 2000
  • Metakaolinite produced by thermal transformation from kaolinite was studied by 27Al multiple quantum magic angel spinning (MQMAS) NMR technique in addition to 1-dimensional 27Al and 29Si MAS NMR. Our results confirm that 4-, 5-, 6- coordinated aluminum sites co-exit with some distribution of isotropic chemical shifts. This is consistent with amorphous character of metakaolinite observed with X-ray diffraction. In addition, characterization with MQMAS is briefly discussed in comparison with other NMR techniques to identify different aluminum sites especially when peaks are severely overlapped in 1-dimensional 27Al MAS NMR spectra.

  • PDF

MAS NMR and XRD Study on the Vanadium Site pf Vanadium Silicate Mesoporous Molecular Sieve MCM-41

  • 박동호;Chi-Feng Cheng;Jacek Klinowski
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.70-75
    • /
    • 1997
  • A wide range (10 < Si/V) of mesoporous vanadium silicate molecular sieves with the MCM-41 structure have been synthesized using vanadyl sulfate as the source of vanadium and characterized by XRD, 51V MAS NMR and 29Si MAS NMR. The increase of the unit cell parameter and the decrease of Q3/Q4 ratio of 29Si spectra with the vanadium content suggest the incorporation of vanadium in the framework of MCM-41 structure. 51V MAS NMR demonstrates that vanadiums in as-synthesized V-MCM-41 are present in the chemical environment of octahedra and octahedral vanadium is decreased and tetrahedral vanadium is increased inversely with raising the calcination temperature. Though the thermal treatment in rotor of hydrated sample resulted in the change from tetrahedral environment to octahedral one and the steaming and the acid treatment affect to the chemical environment of vanadium, the spectrum similar to originally calcined sample is regenerated after recalcination. This indicates that the vanadium is belong to the framework in a relatively exposed site. The best quality XRD pattern of the product of Si/V=27 may be attributable to heterogeneous nucleation mechanism. V-MCM-41's having the Si/V ratio lower than 20 are completely collapsed after calcination.

System Performance Improvement of IEEE 802.15.3a By Using Time Slot Synchronization In MAC Layer (UWB MAC의 Time Slot 동기를 통한 시스템 성능 개선)

  • Oh Dae-Gun;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.3 s.345
    • /
    • pp.84-94
    • /
    • 2006
  • In this paper, we propose the algorithm to reduce guard time of UWB MAC time slot for throughput gain. In the proposed draft by multiband ofdm alliance (MBOA), Guard time of each medium access slot (MAS) is composed of shortest inter-frame space (SIFS) and MaxDrift which is the time caused by maximum frequency offset among devices. In this paper, to reduceguard time means that we nearly eliminate MaxDrift term from guard time. Each device of a piconet computes relative frequency offset from the device initiating piconet using periodically consecutive transferred beacon frames. Each device add or subtract the calculated relative frequency offset to the estimated each MAS starting point in order to synchronize with calculated MAS starting point of the device initiating piconet. According to verification of simulations, if the frequency offset estimator is implemented with 8 decimal bit, the ratio of the wasted time to Superframe is always less than 0.0001.

PHDCM : Efficient Compression of Hangul Text in Parallel (PHDCM : 병렬 컴퓨터에서 한글 텍스트의 효율적인 축약)

  • Min, Yong-Sㅑk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.50-56
    • /
    • 1995
  • This paper describes an efficient coding method for Korean characters using a three-state transition graph. To our knowledge, this is the first achievement of its kind. This new method, called the Paralle Hangul Dynamic Coding Method(PHDCM), compresses about 3.5 bits per a Korean character, which is more than 1 bit shorter than the conventional codes introduced thus far to achieve extensive code compression. When we ran the method on a MasPar machine, which is on SIMD SM (EFEW-PRAM)., it achieved a 49.314-fold speedup with 64 processors having 10 million Korean characters.

  • PDF

Hydration properties of cement pastes containing high-volume mineral admixtures

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • v.7 no.1
    • /
    • pp.17-38
    • /
    • 2010
  • This research aimed to investigate the influence of high-volume mineral admixtures (MAs), i.e., fly ash and slag, on the hydration characteristics and microstructures of cement pastes. Degree of cement hydration was quantified by the loss-on-ignition technique and degree of pozzolanic reaction was determined by a selective dissolution method. The influence of MAs on the pore structure of paste was measured by mercury intrusion porosimetry. The results showed that the hydration properties of the blended pastes were a function of water to binder ratio, cement replacement level by MAs, and curing age. Pastes containing fly ash exhibited strongly reduced early strength, especially for mix with 45% fly ash. Moreover, at a similar cement replacement level, slag incorporated cement paste showed higher degrees of cement hydration and pozzolanic reaction than that of fly ash incorporated cement paste. Thus, the present study demonstrates that high substitution rates of slag for cement result in better effects on the short- and long-term hydration properties of cement pastes.

Surgical Extraction in Patient with McCune-Albright Syndrome: A Case Report

  • Dohee Kim;Jeong Joon Han;Hoon Myoung
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.99-103
    • /
    • 2023
  • McCune-Albright syndrome (MAS) is a disease with clinical features such as fibrous dysplasia in which normal bone tissue is replaced with abnormal fibrous tissue, abnormalities in the endocrine system, and cafe-au-lait spots on the skin. Although MAS patients are generally known to have reduced bone healing ability, postoperative healing after invasive surgical extraction is still not clearly known due to its relatively rare occurrence. In this report, a 25-year-old female patient, who had been diagnosed with MAS and had a history of abnormal bone healing after fractures of her extremities, underwent surgical extraction of the mandibular third molar with surrounding bone removal. Postoperatively, the patient showed favorable soft tissue and bone healing at the surgical site without abnormal findings such as newly developed fibro-osseous lesions, postoperative infection, or osteomyelitis.

Marker-Assisted Selection for Monoecy in Chamoe (Cucumis melo L.) (성발현 연관 분자마커를 이용한 단성화 참외 선발)

  • Bang, Sun-Woong;Song, Kihwan;Sim, Sung Chur;Chung, Sang Min
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.134-141
    • /
    • 2016
  • The DNA marker T1ex, originally developed from melon (Cucumis melo L.) for monoecy, was employed in chamoe, which is referred to as oriental melon. This marker shows size variations in monoecious melon. However, in chamoe, no such detrimental size variation was found in monoecious chamoe, and 99% association between flower phenotypes and genotypes of the T1ex marker was observed in 106 lines of chamoe. To evaluate the efficacy of the T1ex marker for marker-assisted selection (MAS), a total of 240 plants of chamoe breeding lines were screened using the T1ex marker. Among these, 98 varieties were selected. Although the T1ex marker might not be useful for MAS in melon, we found 100% concordance between genotypes and phenotypes for sex expression in chamoe. These results suggest that the T1ex marker will be a useful resource for MAS for monoecy in chamoe.

Effect of Bee-venom Acupuncture on Upper Limb Spasticity of Stroke Patients (중풍 환자의 상지 경직에 대한 봉약침의 효과)

  • Noh, Ju-Hwan;Park, Jung-Ah;Cho, Sung-Woo;Youn, Hyoun-Min;Jang, Kyung-Jeon;Song, Choon-Ho;Ahn, Chang-Beohm;Kim, Cheol-Hong
    • Journal of Acupuncture Research
    • /
    • v.27 no.4
    • /
    • pp.115-125
    • /
    • 2010
  • Objectives : The purpose of this study is to determine the effect of Bee-venom Acupuncture on upper limb spasticity control in stroke patients. Methods : Ten stroke patients with upper limb spasticity were randomly divided into two groups, a Bee-Venom Acupuncture group(group I) and a normal saline group(group II). After 1 week resting phase, this trial was used a cross-over trial. The numbers of Pharmacopuncture treatment were 3 times a week for 3 weeks. Modified Ashworth Scale(MAS), WMFT(Wolf Motor Function Test), The 10-second Test were used for evaluation of spasticity control before experiment, after 1 week, 2 weeks, 3 weeks. Results : Group I showed significant improvement(p<.05) in MAS, WMFT, The 10-second Test. But Group II showed no significant improvement(p<.05) in MAS, WMFT, The 10-second Test. The results showed significant difference in WMFT, The 10-second Test, but no significant difference in MAS between two groups. Conclusions : These results showed that Bee-venom Acupuncture might decrease upper limb spasticity and increase arm motor function in stroke patients. Further studies will be required to examine more cases in the long period for the effect on upper limb in spasticity by Bee-Venom Acupuncture.

Inter-Rater and Intra-Rater Reliability of the Modified Ashworth Scale and the Modified Tardieu Scale: A Comparison Study (수정된 Ashworth 척도와 수정된 Tardieu 척도의 검사자간, 검사자내 신뢰도 비교 연구)

  • Choi, Yul-Jung;Lee, Jung-Ah;Shin, Hwa-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.4
    • /
    • pp.29-33
    • /
    • 2010
  • Purpose: The purpose of this study was to assess and compare the reliability of the Modified Tardieu Scale (MTS) with the Modified Ashworth Scale (MAS) in patients with hemiplegia. Methods: Two experienced physical therapists examined twenty six patients (17 male and 9 female) with an age range of 19-83 years (mean=51.9 SD=15.2). They assessed the elbow flexor/extensor muscle spasticity in the affected side. Interand intra-rater reliability of the MAS and the MTS were calculated using kappa statistics. Intraclass correlation coefficient (ICC) was calculated to determine the inter- and intra-rater reliability of the angle of muscle reactions (R2-R1). Results: The intra-rater reliability of the MAS (K=0.39-0.55) and MTS (K=0.33-0.55) was fair to moderate. The inter-rater reliability was significantly higheras measured with MTS (K=0.54-0.66) in comparison with MAS (K=0.52). Intra-rater reliability of R2-R1 was moderate to almost perfect (ICC=0.52-0.86), and inter-rater reliability was substantial (ICC=0.74-0.76). Conclusion: The MTS provides higher inter-rater reliability compared with the MAS in hemiplegia patient analysis, but intra-rater reliability of both scales was not significantly different. Thus further research is needed to examine not only reliability, but also validity of these measurement systems.