• Title/Summary/Keyword: Mary

Search Result 3,192, Processing Time 0.032 seconds

Automated Versus Handheld Breast Ultrasound for Evaluating Axillary Lymph Nodes in Patients With Breast Cancer

  • Sun Mi Kim;Mijung Jang;Bo La Yun;Sung Ui Shin;Jiwon Rim;Eunyoung Kang;Eun-Kyu Kim;Hee-Chul Shin;So Yeon Park;Bohyoung Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Objective: Automated breast ultrasound (ABUS) is a relevant imaging technique for early breast cancer diagnosis and is increasingly being used as a supplementary tool for mammography. This study compared the performance of ABUS and handheld ultrasound (HHUS) in detecting and characterizing the axillary lymph nodes (LNs) in patients with breast cancer. Materials and Methods: We retrospectively reviewed the medical records of women with recently diagnosed early breast cancer (≤ T2) who underwent both ABUS and HHUS examinations for axilla (September 2017-May 2018). ABUS and HHUS findings were compared using pathological outcomes as reference standards. Diagnostic performance in predicting any axillary LN metastasis and heavy nodal-burden metastases (i.e., ≥ 3 LNs) was evaluated. The ABUS-HHUS agreement for visibility and US findings was calculated. Results: The study included 377 women (53.1 ± 11.1 years). Among 385 breast cancers in 377 patients, 101 had axillary LN metastases and 30 had heavy nodal burden metastases. ABUS identified benign-looking or suspicious axillary LNs (average, 1.4 ± 0.8) in 246 axillae (63.9%, 246/385). According to the per-breast analysis, the sensitivity, specificity, positive and negative predictive values, and accuracy of ABUS in predicting axillary LN metastases were 43.6% (44/101), 95.1% (270/284), 75.9% (44/58), 82.6% (270/327), and 81.6% (314/385), respectively. The corresponding results for HHUS were 41.6% (42/101), 95.1% (270/284), 75.0% (42/56), 82.1% (270/329), and 81.0% (312/385), respectively, which were not significantly different from those of ABUS (P ≥ 0.53). The performance results for heavy nodal-burden metastases were 70.0% (21/30), 89.6% (318/355), 36.2% (21/58), 97.3% (318/327), and 88.1% (339/385), respectively, for ABUS and 66.7% (20/30), 89.9% (319/355), 35.7% (20/56), 97.0% (319/329), and 88.1% (339/385), respectively, for HHUS, also not showing significant difference (P ≥ 0.57). The ABUS-HHUS agreement was 95.9% (236/246; Cohen's kappa = 0.883). Conclusion: Although ABUS showed limited sensitivity in diagnosing axillary LN metastasis in early breast cancer, it was still useful as the performance was comparable to that of HHUS.

Evaluation of Cerebral Blood Flow Using Arterial Spin Labeling in Patients with Chronic Kidney Disease (만성 콩팥병 환자들에서 동맥 스핀 표지 기법을 이용한 뇌 관류상태의 평가)

  • Se Won Oh;Samel Park;Nam-jun Cho;Hyo-Wook Gil;Eun Young Lee;Hyung Geun Oh;Sung-Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.912-919
    • /
    • 2020
  • Purpose This study aimed to compare the brain perfusion status of patients with chronic kidney disease to a normal control group to identify any significant differences. Materials and Methods The perfusion state of the brain was measured by MRI using the arterial spin labeling technique in 36 patients undergoing hemodialysis due to chronic kidney disease and 36 normal controls. Images were then analyzed in a voxel-wise manner to detect brain areas showing significant perfusion differences between the two groups. Results Patients with chronic kidney disease showed increased perfusion in the form of large clusters across the right fronto-parieto-temporal lobe and the left parieto-occipital lobe. In addition, perfusion increased in the bilateral thalami, midbrain, pons, and cerebellum (p < 0.01, familywise error corrected). Conclusion Brain perfusion appears to increase in patients with chronic kidney disease compared to normal controls. Uremic toxicity is thought to be the cause of this increase as it can cause damage to the microscopic blood vessels and their surrounding structures.

Expert Opinions and Recommendations for the Clinical Use of Quantitative Analysis Software for MRI-Based Brain Volumetry (뇌 자기공명영상 뇌용적 분석 소프트웨어의 임상적 적용에 대한 전문가 의견과 권고안)

  • Ji Young Lee;Ji Eun Park;Mi Sun Chung;Se Won Oh;Won-Jin Moon;Aging and Neurodegeneration Imaging (ANDI) Study Group, Korean Society of Neuroradiology (KSNR)
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1124-1139
    • /
    • 2021
  • The objective assessment of atrophy and the measurement of brain volume is important in the early diagnosis of dementia and neurodegenerative diseases. Recently, several MR-based volumetry software have been developed. For their clinical application, several issues arise, including the standardization of image acquisition and their validation of software. Additionally, it is important to highlight the diagnostic performance of the volumetry software based on expert opinions. We instituted a task force within the Korean Society of Neuroradiology to develop guidelines for the clinical use of MR-based brain volumetry software. In this review, we introduce the commercially available software and compare their diagnostic performances. We suggest the need for a standard protocol for image acquisition, the validation of the software, and evaluations of the limitations of the software related to clinical practice. We present recommendations for the clinical applications of commercially available software for volumetry based on the expert opinions of the Korean Society of Neuroradiology.

Is the Mixed Use of Magnetic Resonance Enterography and Computed Tomography Enterography Adequate for Routine Periodic Follow-Up of Bowel Inflammation in Patients with Crohn's Disease?

  • Jiyeon Ha;Seong Ho Park;Jung Hee Son;Ji Hun Kang;Byong Duk Ye;So Hyun Park;Bohyun Kim;Sang Hyun Choi;Sang Hyoung Park;Suk-Kyun Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.30-41
    • /
    • 2022
  • Objective: Computed tomography enterography (CTE) and magnetic resonance enterography (MRE) are considered substitutes for each other for evaluating Crohn's disease (CD). However, the adequacy of mixing them for routine periodic follow-up for CD has not been established. This study aimed to compare MRE alone with the mixed use of CTE and MRE for the periodic follow-up of small bowel inflammation in patients with CD. Materials and Methods: We retrospectively compared two non-randomized groups, each comprising 96 patients with CD. One group underwent CTE and MRE (MRE followed by CTE or vice versa) for the follow-up of CD (interval, 13-27 months [median, 22 months]), and the other group underwent MRE alone (interval, 15-26 months [median, 21 months]). However, these two groups were similar in clinical characteristics. Three independent readers from three different institutions determined whether inflammation had decreased, remained unchanged, or increased within the entire small bowel and the terminal ileum based on sequential enterography of the patients after appropriate blinding. We compared the two groups for inter-reader agreement and accuracy (terminal ileum only) using endoscopy as the reference standard for enterographic interpretation. Results: The inter-reader agreement was greater in the MRE alone group for the entire small bowel (intraclass correlation coefficient [ICC]: 0.683 vs. 0.473; p = 0.005) and the terminal ileum (ICC: 0.656 vs. 0.490; p = 0.030). The interpretation accuracy was higher in the MRE alone group without statistical significance (70.9%-74.5% vs. 57.9%-64.9% in individual readers; adjusted odds ratio = 3.21; p = 0.077). Conclusion: The mixed use of CTE and MRE was inferior to MRE alone in terms of inter-reader reliability and could probably be less accurate than MRE alone for routine monitoring of small bowel inflammation in patients with CD. Therefore, the consistent use of MRE is favored for this purpose.

Automated Measurement of Native T1 and Extracellular Volume Fraction in Cardiac Magnetic Resonance Imaging Using a Commercially Available Deep Learning Algorithm

  • Suyon Chang;Kyunghwa Han;Suji Lee;Young Joong Yang;Pan Ki Kim;Byoung Wook Choi;Young Joo Suh
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1251-1259
    • /
    • 2022
  • Objective: T1 mapping provides valuable information regarding cardiomyopathies. Manual drawing is time consuming and prone to subjective errors. Therefore, this study aimed to test a DL algorithm for the automated measurement of native T1 and extracellular volume (ECV) fractions in cardiac magnetic resonance (CMR) imaging with a temporally separated dataset. Materials and Methods: CMR images obtained for 95 participants (mean age ± standard deviation, 54.5 ± 15.2 years), including 36 left ventricular hypertrophy (12 hypertrophic cardiomyopathy, 12 Fabry disease, and 12 amyloidosis), 32 dilated cardiomyopathy, and 27 healthy volunteers, were included. A commercial deep learning (DL) algorithm based on 2D U-net (Myomics-T1 software, version 1.0.0) was used for the automated analysis of T1 maps. Four radiologists, as study readers, performed manual analysis. The reference standard was the consensus result of the manual analysis by two additional expert readers. The segmentation performance of the DL algorithm and the correlation and agreement between the automated measurement and the reference standard were assessed. Interobserver agreement among the four radiologists was analyzed. Results: DL successfully segmented the myocardium in 99.3% of slices in the native T1 map and 89.8% of slices in the post-T1 map with Dice similarity coefficients of 0.86 ± 0.05 and 0.74 ± 0.17, respectively. Native T1 and ECV showed strong correlation and agreement between DL and the reference: for T1, r = 0.967 (95% confidence interval [CI], 0.951-0.978) and bias of 9.5 msec (95% limits of agreement [LOA], -23.6-42.6 msec); for ECV, r = 0.987 (95% CI, 0.980-0.991) and bias of 0.7% (95% LOA, -2.8%-4.2%) on per-subject basis. Agreements between DL and each of the four radiologists were excellent (intraclass correlation coefficient [ICC] of 0.98-0.99 for both native T1 and ECV), comparable to the pairwise agreement between the radiologists (ICC of 0.97-1.00 and 0.99-1.00 for native T1 and ECV, respectively). Conclusion: The DL algorithm allowed automated T1 and ECV measurements comparable to those of radiologists.

Effects of Breathing Exercise Interventions on Lung Function in COVID-19 Survivors (호흡운동 중재방법이 COVID-19 생존자의 폐기능에 미치는 영향)

  • Chung-Yoo Kim;Hyeon-Su Kim;Yeon-Su Kim;Ki-Jeoung Ahn
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.133-140
    • /
    • 2024
  • Purpose : People who have suffered from COVID-19 suffer from decreased pulmonary function and various side effects. This study aims to present three respiratory exercise intervention methods to improve pulmonary function in COVID-19 survivors. Therefore, the purpose of this study will investigate the effects of breathing exercise interventions (aerobic exercise, diaphragm breathe exercise, and inspiratory muscle training on resistance) on pulmonary function in COVID-19 survivors. Methods : The subjects who participated in this study were 35 male and female college students confirmed with COVID-19. All subjects were randomly assigned to A, D, and I groups according to breathing exercise intervention method. Groups A, D, and I each performed aerobic exercise, diaphragm breathing exercise, and inspiratory muscle training on resistance, 3 times a week for 6 weeks. Pulmonary function was measured using a spirometer, and FVC (forced vital capacity), FEV1 (forced expiratory volume in one second), FEV1/FVC % (forced expiratory volume in one second / forced vital capacity ratio), and PEF (peak expiratory flow) were measured at 0, 3, and 6 weeks. Data analysis was compared by repeated measures analysis of variance, and post hoc tests for time were compared and analyzed using paired t-tests. Results : In the results of this study, FVC values showed statistically significant improvement in all groups. FEV1 values also showed statistically significant improvement in all groups. And the FEV1/FVC % value also showed statistically significant improvement in all groups. And the PEF values also showed statistically significant improvement in all groups. Conclusion : The results of this study reported that aerobic exercise, diaphragm breathing exercise, and resistance inspiratory muscle training were all effective in improving pulmonary function in COVID-19 survivors. Therefore, application of the three breathing exercise intervention methods presented in this study will help improve pulmonary function in COVID-19 survivors.

GRIM-19 Ameliorates Multiple Sclerosis in a Mouse Model of Experimental Autoimmune Encephalomyelitis with Reciprocal Regulation of IFNγ/Th1 and IL-17A/Th17 Cells

  • Jeonghyeon Moon;Seung Hoon Lee;Seon-yeong Lee;Jaeyoon Ryu;Jooyeon Jhun;JeongWon Choi;Gyoung Nyun Kim;Sangho Roh;Sung-Hwan Park;Mi-La Cho
    • IMMUNE NETWORK
    • /
    • v.20 no.5
    • /
    • pp.40.1-40.15
    • /
    • 2020
  • The protein encoded by the Gene Associated with Retinoid-Interferon-Induced Mortality-19 (GRIM-19) is located in the mitochondrial inner membrane and is homologous to the NADH dehydrogenase 1-alpha subcomplex subunit 13 of the electron transport chain. Multiple sclerosis (MS) is a demyelinating disease that damages the brain and spinal cord. Although both the cause and mechanism of MS progression remain unclear, it is accepted that an immune disorder is involved. We explored whether GRIM-19 ameliorated MS by increasing the levels of inflammatory cytokines and immune cells; we used a mouse model of experimental autoimmune encephalomyelitis (EAE) to this end. Six-to-eight-week-old male C57BL/6, IFNγ-knockout (KO), and GRIM-19 transgenic mice were used; EAE was induced in all strains. A GRIM-19 overexpression vector (GRIM19 OVN) was electrophoretically injected intravenously. The levels of Th1 and Th17 cells were measured via flow cytometry, immunofluorescence, and immunohistochemical analysis. IL-17A and IFNγ expression levels were assessed via ELISA and quantitative PCR. IL-17A expression decreased and IFNγ expression increased in EAE mice that received injections of the GRIM-19 OVN. GRIM19 transgenic mice expressed more IFNγ than did wild-type mice; this inhibited EAE development. However, the effect of GRIM-19 overexpression on the EAE of IFNγ-KO mice did not differ from that of the empty vector. GRIM-19 expression was therapeutic for EAE mice, elevating the IFNγ level. GRIM-19 regulated the Th17/Treg cell balance.

Associations of chronotype and insomnia with menstrual problems in newly employed nurses at university hospitals in the Republic of Korea

  • Han-Na Jung;Dongwhan Suh;Woo Chul Jeong;Jia Ryu;Yu-Mi Kim;Seohyun Yoon;Hyunjoo Kim
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.30.1-30.13
    • /
    • 2023
  • Background: Dysmenorrhea and menstrual cycle changes occur in women working shifts. Circadian rhythm disruption and sleep disturbances associated with shift work leads to health problems. We identified chronotypes and the occurrence of insomnia among newly employed university hospital nurses and investigated the association of these factors with menstrual problems. Methods: We conducted pre-placement health examinations for shift workers using self-reported questionnaires between 2018 and 2020. A total of 463 nurses were included in the study. Sociodemographic data, shift work experience, and information on insomnia were collected from health examination data. In addition, details regarding chronotype, dysmenorrhea, irregular and abnormal menstrual cycles, amenorrhea, and contraceptive use were obtained from the questionnaire. Multiple logistic regression analysis was performed to study the association between chronotype, insomnia, and menstrual problems after controlling for age, body mass index, contraceptive use, amenorrhea, and prior shift work. Results: The prevalence rates of dysmenorrhea, irregular menstrual cycles, and longer menstrual cycles were 23.8%, 14.9%, and 4.1%, respectively. The risk of dysmenorrhea increased in the evening-type (odds ratio [OR]: 3.209; 95% confidence interval [CI]: 1.685-6.113) and those with insomnia (OR: 1.871; 95% CI: 1.074-3.261). Additionally, the risk of an irregular menstrual cycle (OR: 2.698; 95% CI: 1.167-6.237) increased in the evening-type, and the risk of a longer menstrual cycle (OR: 4.008; 95% CI: 1.354-11.864) increased in individuals with insomnia. Conclusions: Our findings suggest that dysmenorrhea is promoted in the evening-type and insomnia individuals. There may be an increased risk of irregular menstrual cycles among evening-type nurses and an increased risk of longer menstrual cycles among those with insomnia. Therefore, factors such as evening-type and insomnia should be considered for the prevention of menstrual problems in women performing shift work.

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

  • Kyung Hee Lee;Kun Young Lim;Young Joo Suh;Jin Hur;Dae Hee Han;Mi-Jin Kang;Ji Yung Choo;Cherry Kim;Jung Im Kim;Soon Ho Yoon;Woojoo Lee;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1300-1310
    • /
    • 2019
  • Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.

Requirement of β subunit for the reduced voltage-gated Na+ current of a Brugada syndrome patient having novel double missense mutation (p.A385T/R504T) of SCN5A

  • Na Kyeong Park;Seong Woo Choi;Soon-Jung Park;JooHan Woo;Hyun Jong Kim;Woo Kyung Kim;Sung-Hwan Moon;Hun-Jun Park;Sung Joon Kim
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.28 no.4
    • /
    • pp.313-322
    • /
    • 2024
  • Mutations within the SCN5A gene, which encodes the α-subunit 5 (NaV1.5) of the voltage-gated Na+ channel, have been linked to three distinct cardiac arrhythmia disorders: long QT syndrome type 3, Brugada syndrome (BrS), and cardiac conduction disorder. In this study, we have identified novel missense mutations (p.A385T/R504T) within SCN5A in a patient exhibiting overlap arrhythmia phenotypes. This study aims to elucidate the functional consequences of SCN5A mutants (p.A385T/R504T) to understand the clinical phenotypes. Whole-cell patch-clamp technique was used to analyze the NaV1.5 current (INa) in HEK293 cells transfected with the wild-type and mutant SCN5A with or without SCN1B co-expression. The amplitude of INa was not altered in mutant SCN5A (p.A385T/R504T) alone. Furthermore, a rightward shift of the voltage-dependent inactivation and faster recovery from inactivation was observed, suggesting a gain-of-function state. Intriguingly, the co-expression of SCN1B with p.A385T/R504T revealed significant reduction of INa and slower recovery from inactivation, consistent with the loss-of-function in Na+ channels. The SCN1B dependent reduction of INa was also observed in a single mutation p.R504T, but p.A385T co-expressed with SCN1B showed no reduction. In contrast, the slower recovery from inactivation with SCN1B was observed in A385T while not in R504T. The expression of SCN1B is indispensable for the electrophysiological phenotype of BrS with the novel double mutations; p.A385T and p.R504T contributed to the slower recovery from inactivation and reduced current density of NaV1.5, respectively.