• Title/Summary/Keyword: Mary

Search Result 3,068, Processing Time 0.032 seconds

Safety and tolerability of Korean Red Ginseng in healthy adults: a multicenter, double-blind, randomized, placebo-controlled trial

  • Song, Sang-Wook;Kim, Ha-Na;Shim, Jae-Yong;Yoo, Byeong-Yeon;Kim, Dae-Hyun;Lee, Sang-Hyun;Park, Joo-Sung;Kim, Moon-Jong;Yoo, Jun-Hyun;Cho, BeLong;Kang, Hee-Cheol;Kim, Kwang-Min;Kim, Sung-Soo;Kim, Kyung-Soo
    • Journal of Ginseng Research
    • /
    • v.42 no.4
    • /
    • pp.571-576
    • /
    • 2018
  • Background: Korean Red Ginseng (KRG) has been used in Asia for its various biological effects, but no studies have investigated the safety of its long-term intake. Therefore, the present study evaluated the safety of KRG intake for 24 weeks. Methods: We randomized 1,000 participants in a 1:1 ratio into two groups, which were treated daily with 2 g of KRG or a placebo for 24 weeks. The primary endpoint was all adverse events and adverse drug reactions (ADRs) that occurred after KRG or placebo administration, which were reported at week 4, 12, and 24 after the baseline visit. Results: In total, 192 and 211 participants experienced adverse events in the KRG and placebo groups (39.2% and 42.0%, respectively; p = 0.361), and 59 and 57 KRG- and placebo-treated individuals reported ADRs (12.0% and 11.4%, respectively; p = 0.737). The frequently occurring ADRs were pruritus (2.0%), headache (1.6%), diarrhea (1.4%), and dizziness (1.2%) in the KRG group and pruritus (2.0%), headache (1.8%), dizziness (1.6%), rash (1.4%), and diarrhea (1.2%) in the placebo group. Discontinuation of drug administration due to ADRs was reported in 13 participants, six (1.2%) and seven (1.4%) in the KRG and placebo groups, respectively (p = 0.814). No significant abnormal changes were revealed by anthropometric, laboratory, and vital sign measurements in the KRG group compared with those in the placebo group. Conclusion: The present study confirms the safety and tolerability of daily intake of 2 g of KRG for 24 weeks by healthy adults.

Differences in muscle activity by IASTM between a tool made of PLA made with a 3D printer and a ready-made tool made of stainless steel (3D프린터로 제작된 PLA재질의 도구와 기성품인 스테인리스 스틸 재질의 도구 사이의 연부조직 가동술에 의한 근활성도 차이)

  • Kim, Chung-Yoo;Kang, Jong-Ho;Tae, Won-Kyu
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.218-223
    • /
    • 2020
  • This study was conducted to observe the difference in muscle activity by IASTM between a tool made of PLA made with a 3D printer and a tool made of ready-made stainless steel. This study was attended by 10 adults in their twenties, and all subjects participated in both the PLA group and the Stainless group, received IASTM. %MVIC was measured by measuring muscle activity after intervention, and this was verified through comparison between groups through the Mann-Whitney U test. The results of this study showed that there was no significant difference between the two groups in the %MVIC value of the biceps brachii after intervention. Therefore, in the application of IASTM, there was no difference in muscle activity depending on the material of the tool, which seems to be that the IASTM tool made of PLA made with a 3D printer produced similar results in the ability to control neuromuscular muscles and the ready-made product made of stainless steel. Therefore, in a future study, the effectiveness of the tool will be verified for the various patient group.

The status of Healthcare-associated Infection Control among Healthcare Facilities in Korea (국내 의료기관의 의료관련감염 관리 실태)

  • Jeong, Sun-Young;Kim, Og Son;Lee, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.5
    • /
    • pp.353-366
    • /
    • 2014
  • The purpose was to describe the state of healthcare-associated infection(HAI) control. Data were collected from 134 hospitals. The questionnaire developed by Kang[8] were modified. The mean of hospital beds was 556.4, 26.9% of hospitals were less than 300 beds. 99.3% of hospitals had infection control committee(ICC). ICC met 3.4 times a year. 54.5% of hospitals had one infection control practitioner(ICP). 95.5% of ICPs were nurse, 48.7% of ICPs had more than master's degree. Hospital experience of ICPs was 13.5 years. ICP experience was 3.2 years. 30.8% of ICPs worked for less than 1 year. All hospitals investigated HAI, 75.4% performed improvement activities. There are significant differences in existence of ICD, negative pressure room, computer program, numbers of ICPs according to hospital size. Manpower, organization, and facilities lacked in less than 300 beds. This conclusions will give baseline data to establish infection control system, manpower and practice in small-medium hospitals.

Effect of Different Surface Treatment on the Shear Bond Strength between Yttria-Tetragonal Zirconia Polycrystal and Non-10-Methacryloyloxydecyl Dihydrogen Phosphate-Containing Resin Cement

  • Lee, Yoon;Yi, Young-Ah;Kim, Sin-Young;Seo, Deog-Gyu
    • Journal of Korean Dental Science
    • /
    • v.7 no.2
    • /
    • pp.49-57
    • /
    • 2014
  • Purpose: To evaluate the effect of different surface treatment methods (yttria-tetragonal zirconia polycrystal [Y-TZP] primers, air-abrasion, and tribochemical surface treatment) on the shear bond strength between (Y-TZP) ceramics and etch-and-rinse non-10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing resin cements. Materials and Methods: Y-TZP ceramic surfaces were ground flat with 600-grit silicone carbide abrasives paper and then divided into seven groups of ten. They were treated as the following: untreated (control), Monobond Plus (IvoclarVivadent), Z-PRIME Plus (Bisco Inc.), ESPE Sil with CoJet (3M ESPE), air-abrasion, Monobond Plus with air-abrasion, and Z-PRIME Plus with air-abrasion. The surface of Y-TZP specimens was analyzed under a scanning electron microscope (SEM). Non-MDP-containing cements were placed on the surface-treated Y-TZP specimens. After thermocycling, shear bond strength test was performed. Bond strength values were statistically analyzed using one-way analysis of variance and Student-Newman-Keuls multiple comparison test (P<0.05). Result: The Z-PRIME Plus treatment in combination with air-abrasion produced the highest bond strength ($14.94{\pm}1.70MPa$) followed by Monobond Plus combined with air-abrasion ($10.70{\pm}1.71MPa$), air-abrasion ($10.47{\pm}1.60MPa$), ESPE Sil after CoJet treatment ($10.38{\pm}0.87MPa$), Z-PRIME Plus application ($10.00{\pm}1.70MPa$), and then Monobond Plus application ($9.25{\pm}0.86MPa$). The control ($6.70{\pm}1.49MPa$) indicated the lowest results (P<0.05). The SEM results showed different surface morphologies according to surface treatment methods compared with the Y-TZP control. Conclusion: The shear bond strength between the Y-TZP ceramic and the non-MDP-containing resin cement was the greatest when the surface was treated with air-abrasion and MDP-containing Z-PRIME Plus primer.

Accuracy of Temperature Measurements, Nursing Time for Measuring Temperature and the Validity of Fever Detection (체온측정방법의 정확도와 간호시간 및 발열감별 타당도 비교)

  • Sohng Kyeong-Yae;Kang Sung-Sil;Hwang Jin-Soon;Kim Myung-Ja
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.33-45
    • /
    • 1998
  • The aim of this study was to investigate what is the most accurate and quick temperature measurement among rectal, auxiliary and tympanic routes. The body temperatures of 86 preform infants in incubators, a controlled environment, were measured at three different sites. The measurements were taken to examine the accuracy of the temperatures, proper nursing time for measuring the temperatures and the validity of fever detection. The results were as follows : 1. The mean temperature was significantly lower in the auxiliary site($36.71^{\circ}C$) and higher in the tympanic site($37.27^{\circ}C$) than in the rectal site($37.03^{\circ}C$). 2. The mean nursing time for measuring body temperature was significantly longer in the auxiliary site(171.65 seconds) and shorter in the tympanic site(17.70 seconds) than in the rectal site(83.33 seconds). 3. The nursing time for measuring body temperature included the time needed for preparation, measuring, as well as the post-measuring time. It was found that the time required to prepare for measuring the temperature of the rectal site was significantly longer than for other sites. In addition, the time needed to measure the temperature of the auxiliary site was significantly longer than in the other sites. Finally, the nursing time needed for measuring the auxiliary temperature(171.65 seconds) was the longest among the three sites whereas the nursing time for the tympanic site was the shortest(17.70 seconds). 4. Rectal temperature was significantly correlated to the tympanic(r=0.67) and auxiliary temperatures(r=0.69). Tympanic temperature was also significantly correlated to the auxiliary temperature(r=0.74). 5. The sensitivity, specificity, positive and negative predictive values of tympanic temperatures for detecting fever were 1.00, 0.80, 0.24, and 1.00, respectively. Those for the auxiliary temperatures were 0.00, 0.99, 0.00, and 0.94, respectively. Thus the level of fever detection was lower in the auxiliary temperatures than in tympanic temperatures. The above findings indicate that the tympanic method of temperature measurement offers a useful alternative to conventional methods.

  • PDF

Behavior of Retinal Pigment Epithelial Cells Cultured on Silk Films (실크필름에 배양한 망막색소상피세포의 거동)

  • Lee, So Jin;Kim, Hye Yun;Kim, Seul Ji;Yang, Jaewon;Lee, Seon Ui;Park, Chan Hum;Joo, Choun-Ki;Khang, Gilson
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.364-370
    • /
    • 2014
  • The retinal pigment epithelium (RPE) plays an important role in maintaining a healthy retina and the degeneration of RPE caused a number of retinal diseases. The transplantation of RPE has recently become a possible therapeutic modality for retinal degeneration. To transplant RPE cells securely, substrates are essential, and then as a substrate, we fabricated films using silk that has unique mechanical properties and biocompatibility. After the FTIR spectra, contact angle and biodegradation of silk films were confirmed, RPE cells were seeded and the influence of RPE cells on silk films was examined. We measured the cell adhesion, cell viability, morphology and specific mRNA expression by MTT assay, SEM, immunofluorescence and RT-PCR. In this study, we confirmed that attachment, proliferation and phenotype maintenance of RPE cells cultured on silk films were great, and thereby we were able to confirm the potential applications of silk films as tissue engineering carrier for regeneration of retina.

Factors Affecting Health Promotion Behavior of Apheresis Blood-Donors (성분헌혈자의 건강증진행위에 영향을 미치는 요인)

  • Hong Kyong Hee;Park Ho Ran
    • Journal of Korean Public Health Nursing
    • /
    • v.19 no.1
    • /
    • pp.41-52
    • /
    • 2005
  • This study was designed to provide a base for nursing intervention to help apheresis blood-donors to perform health promotion behavior effectively by surveying their health promotion behavior and by analyzing the critical factors. The study subjects were 468 participants in platelet donation at a university hospital apheresis unit in Seoul. The data for this study were collected between May and June. 2002. by questionnaire. Data were analyzed by t-test, ANOVA. Scheffe test, Pearson correlation coefficient. and stepwise multiple regression. The results were as follows. 1. The degree of performance of health promotion behavior of the subjects was a total average score of $152.9\pm21.5$ points and a mean score of 2.7 points. The highest score was 'I have a good relationship with others' in the factor of self-actualization and interpersonal support. The lowest score was 'I have my blood pressure checked regularly' in the factor of health responsibility. 2. Considering the classification according to the subjects' general characteristics. the health promotion behavior score was significantly higher for soldiers than high school students, for religious believers than atheists. and for high class economic status than mid and low class economic status. Also the health promotion behavior score was higher for those who had made more than five blood donations than those who had made zero or one donation. and for those who had made more than four blood donations than for those who had made less than four blood donations in the previous times of apheresis blood donation. The score was also higher for those not having a relationship with recipient than those having a relationship. 3. The self-efficacy related to donation. general self-efficacy and self-esteem had a significant correlation with the performance in health promotion behavior. 4. The critical factors that influenced the health promotion behavior were explained by $35.6\%$ of the general self-efficacy and by $40.2\%$ of the total of self-efficacy related to donation, and previous times of apheresis blood donation. The health promotion behavior score of apheresis blood-donors differed according to job, religion, economic status, previous times of whole blood donation, previous times of apheresis blood donation, and relationship with recipient. The health promotion behavior and self-efficacy related to donation, general self-efficacy, and self-esteem showed significant positive correlation with one another. The general self-efficacy, self-efficacy related to donation, and previous times of apheresis blood donation appeared to be the significant predictive factors of health promotion behavior. Therefore, from these study results, it is necessary to establish more effective and organized nursing intervention strategies for the health promotion behavior of apheresis blood-donors.

  • PDF

Characteristics of Breast Cancer Patients, their Understandings and Attitude towards the Disease (유암환자의 제 특징 및 유암에 관한 태도와 그 인식도)

  • 노유자
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.1
    • /
    • pp.30-38
    • /
    • 1977
  • Breast cancer is one of the most feared health problems in women ; Recent studies revealed that it had come up to be the second most in this country and high prevalent disease in the western countries among breast disease in women. However, early detection of the cancer mass is known to be easier than in many other malignancies. This study was performed to investigate the various characteristics of patients of breast cancer ; by the structural variables, menstrual, marital, and child bearing, and also their understandings and attitude towards the disease. A hundred any in- and out- patients of 51. Mary's Hospital and National Atomic Institute, Seoul were sampled. Data were gathered through direct interview by the researcher from February 1976 to January 1977 and the clinical records were used as references. Results are as follows ; 1. Breast cancer revealed to be most prevalent in the forties ; average age of 45.2 years. 2. The average age of menarche revealed to be 15.4 years ; the largest group were the 16-20 years (N=75, 68.2%). In 55 cases (50%) menstruation were normal, 38 (34.5%) postmenopausal and only in 17 (15.5%), menstruation revealed irregularity. 3. The average marital age revealed to be 22.3 years ; the largest group were 21-25 group (N=43, 39.1%). The average duration of marital life revealed to be 24.7 years ; 11-20 years group were the largest (M=34, 30.9%). 4. Most of the patients revealed to have pregnancy experiences(N=100, 90.9%) ; the average rate of experience were 5, 3 times the largest group were 3.4 times group(N= 32, 29.1%). 54 patients (49.1%) revealed to have had abortion experience ; the average were 3.4 times. 5. The largest group(N=77, 70%) had been breast feeding : followed by mixed feeding (N=12, 10.9%) and artificial feeding(N=10, 9.1%). 6. Personal health history revealed that in 20 patients (18.2%) revealed to have the past history of Purulent mastitis, 5 patients(4.5%) of breast cancer and 3 patients(2.7%) of uttering cancer family history. 7. In the one half (N=56, 50.9%, they had some information about breast cancer :27 (24.5%) by mass media, 12 (10.9%) through personal contacts and 17 (15.5%) were not able to classify the source of information. 8. In 55 cases (50%) the canoe, mass were discovered incidentally, in 39 cases (35.5%) by manual detection by self, in 10 cases (9%) by others and in 6 cases(5.5%) by observing subjective symptoms. 9. The average duration lapsed between the discovery of cancer mass and the visit to the hospital revealed to be 9.4 month. Chief reason for the delay revealed to be the non-chaplaincy due to the absence of pain(N=50, 45.5 %) followed by the administration of herb and commercial medication (N=19, 17.3%). 10. The left side breast was more affected than the right side breast, represent by 60 cases in the left and 39 cases in the right. The most frequent site of the breast cancer was the upper- outer quadrant in 53 cases (47.7%), and followed by the center in 20 cases(18 %), and the upper inner quadrant, in 19 cases (17.1%). There was / cases of bilateral carcinoma. The most prominent symptom was painless mass.

  • PDF

THE EFFECT OF VARIOUS SURFACE TREATMENT METHODS ON THE OSSEOINTEGRATION (임플랜트의 표면처리 방법이 골유착에 미치는 영향에 관한 연구)

  • Choi Jeong-Won;Kim Kwang-Nam;Heo Seong-Joo;Chang Ik-Tae;Han Chong-Hyun;Baek Hong-Gu;Choi Yong-Chang;Wennerberg Ann
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.71-83
    • /
    • 2001
  • The purpose of this study was to compare the effects of various surface treatments by measuring removal torque on bone healing around titanium implants. 40 Screw-shaped cp titanium implants with length of 4mm, outer diameter of 3.75mm, and pitch-height of 0.5mm were used Group 1 was left as machined(control), Group 2 was blasted with $50{\mu}m\;Al_2O_3$, group 3 was blasted and etched in etching solution($NH_4OH : H_2O_2:H_2O= 1 : 1 : 5$) at $90^{\circ}C$ for 1 minute group 4 was blasted and oxidated under pure oxygen at $800^{\circ}C$. The implant surface roughness was analyzed with SEM and CLSM(Confocal Laser Scanning Microscope) and implants were placed in proximal tibial metaphysis of 10 New Zealand White rabbits. After 3 months of healing period, removal torque of each implant was measured to compare bone healing around implant. The results obtained were as follows 1. In SEM view, blasting increased the roughness of the surface, but etching of that rough surface decreased the roughness due to the removal of the tip of the peak. Oxidation also decreased the roughness due to formation of needle-like oxide grains on the implant surface. 2. The Sa value from CLSM was least in the machined group($0.47{\mu}m$), greatest in blasted group($1.25{\mu}m$), and the value decreased after etching($0.91{\mu}m$) and oxidation($0.94{\mu}m$). 3. The removal torque of etched group(24.5Ncm) was greater than that of machined group(16.7Ncm) (P<0.05), and was greatest in the oxidated group(40.3Ncm) and the blasted group(34.7Ncm).

  • PDF

Prognostic Significance of Lymphatic and Perineural Invasions in Patients with Gastric Cancer Who Have No Lymph Node and Serosal Involvement (장막 침윤과 림프절 전이가 없는 위암에서 림프관 및 신경초 침윤의 의의)

  • Kim Wook;Park Cho Hyun;Park Seung Man;Park Woo Bai;Lim Keun Woo;Kim Seung Nam
    • Journal of Gastric Cancer
    • /
    • v.1 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • Purpose: The most important prognostic factors in gastric cancer are depth of invasion and lymph node metastasis. Therefore, the prognosis for serosa and lymph node negative gastric cancer is favorable. However, there is no general agreement on the prognostic factors in this subset of patients. This study was undertaken to evaluate the prognostic significances of venous invasion (VI), lymphatic invasion (LI), and perineural invasion (NI) in T1 and T2 gastric cancer without lymph node involvement. Materials and Methods: We retrospectively evaluated 206 patients with T1 and T2, lymph node negative gastric cancer who underwent a curative resection from 1989 to 1993 at Kangnam St. Mary's Hospital, Seoul, Korea. The Chi-square test was used to determine the statistical significance of differences, and the Kaplan-Meier method was used to calculate survival rates. Significant differences in the survival rates were assessed using the log-rank test, and the Cox regression method was used to evaluate independent prognostic significance. Results: The rate of VI, LI and NI correlated well with the depth of tumor invasion. The rates of VI (+) for T1 vs T2 was $0\%\;vs\;5.1\%$, of LI (+) was $5.6\%\;vs\;26.8\%$, and of NI (+) was $1.6\%\;vs\;26.8\%$ in NI (+). There were 13 recurrent cases, 10 cases out of the 13 were T2 gastric cancers, and the recurrence rate was higher in LI (+) and NI (+) cases than in LI (-) and NI (-) cases. The 5-year survival rates were $93.4\%$ in LI (-) cases, $77.4\%$ in LI (+) cases, $92.5\%$ in NI (-) cases, $74\%$ in NI(+) cases, $95.9\%$ in LI (-) NI (-) cases, and $73.9\%$ in LI (+) NI (+) cases. Multivariate analysis demonstrated that simultaneous LI and NI was the only significant factor influencing the prognosis. Conclusion: These results suggest that simultaneous lymphatic and perineural invasion may be an independent prognostic factor in patients with T1 and T2 gastric cancer without lymph node metastasis.

  • PDF