• Title/Summary/Keyword: Mary

Search Result 3,114, Processing Time 0.026 seconds

Evaluation of health screening data for factors associated with peri-implant bone loss

  • Hyunjong Yoo;Jun-Beom Park;Youngkyung Ko
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.509-521
    • /
    • 2022
  • Purpose: Systemic health has a profound effect on dental treatment. The aim of this study was to evaluate peri-implant bone loss and health screening data to discover factors that may influence peri-implant diseases. Methods: This study analyzed the panoramic X-rays of patients undergoing health screenings at the Health Promotion Center at Seoul St. Mary's Hospital in 2018, to investigate the relationship between laboratory test results and dental data. The patients' physical data, such as height, weight, blood pressure, hematological and urine analysis data, smoking habits, number of remaining teeth, alveolar bone level, number of implants, and degree of bone loss around the implant, were analyzed for correlations. Their associations with glycated hemoglobin, glucose, blood urea nitrogen (BUN), creatinine, and severity of periodontitis were evaluated using univariate and multivariate regression analysis. Results: In total, 2,264 patients opted in for dental health examinations, of whom 752 (33.2%) had undergone dental implant treatment. These 752 patients had a total of 2,658 implants, and 129 (17.1%) had 1 or more implants with peri-implant bone loss of 2 mm or more. The number of these implants was 204 (7%). Body mass index and smoking were not correlated with peri-implant bone loss. Stepwise multivariate regression analysis revealed that the severity of periodontal bone loss (moderate bone loss: odds ratio [OR], 3.154; 95% confidence interval [CI], 1.175-8.475 and severe bone loss: OR, 7.751; 95% CI, 3.003-20) and BUN (OR, 1.082; 95% CI, 1.027-1.141) showed statistically significant predictive value. The severity of periodontitis showed greater predictive value than the biochemical parameters of blood glucose, renal function, and liver function. Conclusions: The results of this study showed that periodontal bone loss was a predictor of peri-implant bone loss, suggesting that periodontal disease should be controlled before dental treatment. Diligent maintenance care is recommended for patients with moderate to severe periodontal bone loss.

Comparative Study on the Clinical Trial of Acupotomy Treatment for Lumbar Disk Herniation

  • Beom Seok Kim;Ju Hyun Jeon;Tae Yong Park;Hong Kyoung Kim;Young Il Kim
    • Journal of Acupuncture Research
    • /
    • v.40 no.3
    • /
    • pp.252-264
    • /
    • 2023
  • Background: The primary aim of this study is to statistically analyze and compare the difference in treatment outcomes based on the frequency and duration of acupotomy treatment for lumbar disk herniation. Methods: The evaluation of efficacy and safety involved using visual analog scale (VAS), numeric rating scale (NRS), Roland Morris disability questionnaire (RMDQ), EuroQol 5-dimention (EQ-5D), and similar parameters. This was achieved through the establishment of a comparable cohort using propensity score matching. Group A comprised 46 patients who underwent 4 sessions of acupotomy treatment for 2 weeks, while Group B consisted of 15 patients who received 6 acupotomy sessions for 3 weeks. Results: For Group A, the average amount of change in VAS values at weeks 4 and 6 was significantly decreased. However, the average amount of change in RMDQ values was not significant. Notably, the average amount of change of EQ-5D values at week 6 increased significantly. As for Group B, the average amount of change of NRS values in weeks 2 and 3 was significantly decreased. Conversely, the average amount of change in RMDQ and EQ-5D values was not significant. In comparing the 2 groups at the final follow-up, the average amount of change in all evaluation values was not significant. Further, no significant interaction effect was observed in the changes over time in all evaluation values between the 2 groups. Conclusion: This study establishes that there was no statistically significant difference in pain reduction, functional impairment, and quality of life improvement between 2 group.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.

The Effect of Posture Holding Band on Muscle Activity of Quadriceps Femoris and Weight Distribution during Squat Exercise (자세유지밴드가 스쿼트 운동 시 넙다리네갈래근의 근활성도와 체중분포에 미치는 영향)

  • Chung-Yoo Kim;Won-Sik Bae;Sung-Ha Yu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.91-98
    • /
    • 2023
  • Purpose : The purpose of this study was to investigate the effect of the posture holding band on muscle activity of the rectus femoris, medial vastus, and vastus lateralis muscles and weight distribution during squat exercise. Methods : This study was conducted with 30 healthy adult men and women in their 20s, and all subjects were randomly assigned to the experimental group and the control group. Squat exercise was performed for 6 weeks. The experimental group received squat exercise while wearing a posture holding band, and the control group applied without wearing a posture holding band. Muscle activity of the quadriceps femoris (rectus femoris, vastus medialis, and vastus lateralis) and weight distribution (knee flexion 0 °, 30 °, 60 °, and 90 °) was measured. Results : According to the results of this study, all three muscles showed a main effect on time and group, and a significant interaction was shown only in the vastus lateralis. In addition, the value of the weight distribution difference according to the knee flexion angle did not show a main effect according to time and group at 30 ° of knee flexion, but showed an interaction. Conclusion : It was confirmed that the application of the posture holding band during squat exercise increased the muscle activity of the quadriceps muscle, and showed greater changes in the vastus lateralis muscle. In addition, it was confirmed that the difference in weight distribution was reduced in the knee flexion, and in particular, a greater change was shown in reducing the difference in weight distribution in the knee flexion of 30 °. Therefore, it is considered that the effect of the exercise can be further enhanced if the unnecessary movement of the trunk is controlled by using equipment such as a posture holding band during squat exercise.

Description of Vishniacozyma terrae sp. nov. and Dioszegia terrae sp. nov., Two Novel Basidiomycetous Yeast Species Isolated from Soil in Korea

  • Soohyun Maeng;Yuna Park;Gi-Ho Sung;Hyang Burm Lee;Myung Kyum Kim;Sathiyaraj Srinivasan
    • Mycobiology
    • /
    • v.50 no.6
    • /
    • pp.439-447
    • /
    • 2022
  • Two strains, YP344 and YP579 were isolated from soil samples in Pocheon City, Gyeonggi Province, South Korea. The strains YP344 and YP579 belong to the genus Vishniacozyma and Dioszegia, respectively. The molecular phylogenetic analysis showed that the strain YP344 was closely related to Vishniacozyma peneaus. Strain YP344T differed by four nucleotide substitutions with no gap (0.70%) in the D1/D2 domain of the LSU rRNA gene and 16 nucleotide substitutions with 8 gaps (5.76%) in the ITS region. On the other hand, the strain YP579T varied from the type strain of the most closely related species, Dioszegia zsoltii var. zsoltii, by 6 nucleotide substitutions with four gaps (1.64%) in the D1/D2 domain of LSU rRNA gene and 26 nucleotide substitutions with 14 gaps (8.16%) in the ITS region. Therefore, the name Vishniacozyma terrae sp. nov. and Dioszegia terrae sp. nov. are proposed, with type strains YP344T (KCTC27988T) and YP579T (KCTC 27998T), respectively.

Investigation and Standardization on Current Practice of Renal Transplant Pathology in Korea

  • Cho, Uiju;Suh, Kwang Sun;Kie, Jeong Hae;Choi, Yeong Jin;Renal Pathology Study Group of Korean Society of Pathologists,
    • Korean Journal of Transplantation
    • /
    • v.31 no.4
    • /
    • pp.170-176
    • /
    • 2017
  • We need to establish an informative guideline to increase inter-institutional and inter-observer reproducibility of renal transplant diagnosis, and to improve the diagnostic ability of pathologists in Korea. A first nation-wide survey for renal transplant pathology was conducted by Renal Pathology Study Group of the Korean Society of Pathologists in 2016, to provide the continued excellence in the transplantation pathology laboratory, and to improve the diagnostic ability for the best treatment of transplant patients. This survey revealed the significant variations in scale, work load and biopsy indications for the renal transplant pathology in various institutions in Korea. The Banff classification were used by all institutions for the diagnosis of renal transplant pathology, but different formats were used: most institutions (70%) used the "2013 Banff classification" while the others were using "2007 Banff classification" (20%) or even older formats. In daily diagnostic practice of the renal allografts, difficulties that pathologists encounter were quite diverse due to different environments they work in. Most respondents agreed that standardized diagnostic practice guidelines, regular education on renal transplant pathology and convenient ways of consultation are further needed. We are currently working toward the enhancement of the expertise of renal pathologists and to increase inter-institutional and inter-observer reproducibility by 1) development of a set of virtual slides of renal allograft biopsies for the training, 2) validation and gathering expert's consensus on the core variables of rejection diagnosis by using virtual slides, and 3) continued education by the developed virtual slide atlas.

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.

Exploring Factors of Corporate Entrepreneurship within Medical Institutions : Focusing on the Perspective of Participants in the In-house Innovation & Start-up Contest (의료기관 내 사내기업가정신 확산 요인에 대한 탐색 : 사내 혁신·창업 공모전 참가자의 관점에서)

  • Jae-hoon, Han;Byeung-tae, Park;Byung-jin, Park
    • Korea Journal of Hospital Management
    • /
    • v.27 no.4
    • /
    • pp.36-55
    • /
    • 2022
  • Purpose: This study explores the diffusion factors of corporate entrepreneurship among members of medical institutions. Methodology/Approach: The study explores the case of Granum Sinapis Center at Seoul St. Mary's Hospital, the first medical institution to establish a support organization for "innovation and start-up" as well as examines the changes in individual perceptions of participants in the institution's in-house contest. Among the 140 participants in the 2nd Contest held in 2022, seven participants were selected for interview in consideration of their job occupation and years of service. In-depth interviews were conducted for each individual. Findings: The participants applied for the contest under the direct and indirect influence of co-workers as well as compensatory factors. An individual's corporate entrepreneurial characteristics can be innate or acquired. The participants of the in-house contest had a positive experience in contrast to the existing organizational culture. The results reveal that emotional support from top and middle managers, along with the role of dedicated departments, can affect innovative behavior. Practical Implications: Contest participants reported personal growth, improved job satisfaction, and a change in perception of the organizational culture; they expressed their willingness to recommend. The results confirm the need to support such systems and shift focus to managerial (emotional) support and dedicated resources for developing individual entrepreneurship.

Comparative Analysis of Machine Learning Techniques for IoT Anomaly Detection Using the NSL-KDD Dataset

  • Zaryn, Good;Waleed, Farag;Xin-Wen, Wu;Soundararajan, Ezekiel;Maria, Balega;Franklin, May;Alicia, Deak
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.1
    • /
    • pp.46-52
    • /
    • 2023
  • With billions of IoT (Internet of Things) devices populating various emerging applications across the world, detecting anomalies on these devices has become incredibly important. Advanced Intrusion Detection Systems (IDS) are trained to detect abnormal network traffic, and Machine Learning (ML) algorithms are used to create detection models. In this paper, the NSL-KDD dataset was adopted to comparatively study the performance and efficiency of IoT anomaly detection models. The dataset was developed for various research purposes and is especially useful for anomaly detection. This data was used with typical machine learning algorithms including eXtreme Gradient Boosting (XGBoost), Support Vector Machines (SVM), and Deep Convolutional Neural Networks (DCNN) to identify and classify any anomalies present within the IoT applications. Our research results show that the XGBoost algorithm outperformed both the SVM and DCNN algorithms achieving the highest accuracy. In our research, each algorithm was assessed based on accuracy, precision, recall, and F1 score. Furthermore, we obtained interesting results on the execution time taken for each algorithm when running the anomaly detection. Precisely, the XGBoost algorithm was 425.53% faster when compared to the SVM algorithm and 2,075.49% faster than the DCNN algorithm. According to our experimental testing, XGBoost is the most accurate and efficient method.

Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology (3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발)

  • Jeong-Wan Kim;Youl-Hun Seoung
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.