• 제목/요약/키워드: Marx Generator

검색결과 37건 처리시간 0.024초

배전용 변압기를 통한 저압전원선으로의 뇌서지 전파 (Propagation of Lightning Surges on Power AC Lines through Distribution Transformers)

  • 이복희;이수봉;이동문
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

펄스파워전원용 고전압 펄스변압기 (High voltage Pulse Transformer for Pulsed Power Supply)

  • 김종해;구치욱;최영욱;이홍식;임근희;고광철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1755-1757
    • /
    • 1998
  • Pulse transformers have been developed to apply for pulsed power technology as an alternative of a Marx generator. To obtain repetitive pulsed power generation, it is necessary to observe the rising time of output of pulse transformer. In this paper, using the equivalent circuit, The rising wave of output of pulse transformer is simulated for various input wave by using the Electromagnetic transient program(EMTP).

  • PDF

500 kV 다중 채널 다중 갭 자발 방전 개스 스위치 개발 (Developments of 500 kV Multi-Channel Multi-Gap Self Breakdown Switch)

  • 박성수;남상훈;김상희;허훈;김승환;박용정;손병학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2149-2152
    • /
    • 2005
  • 가속기 연구소에서 500kV 고전압 다중채널 다중갭(MGMC) 스위치를 개발하였다. 이 다중 채널 다중 갭 스위치는 개스를 채우는 방식으로 자발 방전전압을 증가 시킬 수 있는 10단의 갭으로 구성이 되어 있다. 멀티갭 스위치의 구조는 스위치의 자체 인덕턴스를 증가시키는 결과를 가져온다. 따라서 이러한 문제점을 해결하기 위하여 다중채널을 사용하여 인덕턴스를 줄이는 스위치로 구조를 설계하였다. 제작된 스위치는 500kV의 Marx generator를 사용하여 시험을 하였다. 본 논문에서는 개발된 스위치 선계 및 스위치의 특성에 대하여 알아보고자 한다.

  • PDF

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF

Characteristics of Lightning Overvoltages Coming in Low-Voltage Power Distribution Systems

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Su-Bong;Jeong, Dong-Cheol;Lee, Jae-Bok;Myung, Sung-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.91-98
    • /
    • 2003
  • The importance of improving the quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and systems. The transient over-voltages on low-voltage power distribution systems are induced by direct or indirect lightning return strokes. These can cause damage and/or malfunction of the utility systems for home automation, office automation, factory automation, medical automation, etc. The behaviors of lightning overvoltages transferred through the transformer to the low-voltage distribution systems using a Marx generator were experimentally investigated. Furthermore, the coupling mechanisms of lightning overvoltages transferred to the low-voltage systems were clearly illustrated through a theoretical simulation using a Pspice program. The overvoltages in low-voltage ac power systems are rarely limited by the application of the surge arrester to the primary side of the distribution transformer. A superior surge protection scheme is to install surge protection devices at the service entrance switchboard and/or at the load devices in TN power systems.

배전용 변압기를 통하여 저압 전원선으로 전파되는 뇌서지 (Lightning Surges Transferred to Low-voltage AC Power Lines through Distribution Transformers)

  • 이복희;이동문;이수봉
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.94-99
    • /
    • 2003
  • 정밀하고 소형화된 전자기기 사용의 증가로 인한 전원공급의 질적 향상에 대한 필요성이 강하게 증가하고 있다. 저압전원 배전계통에서의 과도 과전압은 직격 또는 유도뢰에 의해 유도되어지고, 가정, 사무실, 공장 등의 자동화시스템이나 병원설비와 같은 중요한 시스템의 손상이나 고장의 원인이 되고 있다. 본 논문에서는 임펄스 발생기를 이용하여 배전용 변압기를 거쳐 저압 전원시스템으로 이행되는 뇌과전압의 양상에 대하여 실험적으로 조사하였다. 배전용 변압기의 1차측에 설치한 피뢰기와 수용가측 추가접지는 저압 전원시스템으로 이행되는 뇌서지전압의 제한에는 크게 기여하지 않았다.

수중에 잠긴 접지전극 주변에서의 이온화에 의한 전위저감 및 에너지방출 (Potential Reduction and Energy Dispersion Due to Ionization Around the Submerged Ground Rod)

  • 최종혁;안상덕;양순만;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.92-99
    • /
    • 2009
  • 심매설 접지봉의 경우 장마철에 빗물이나 지하수와 접촉하는 경우가 발생한다. 수중에 잠겨있는 접지극에 서지 전압이 인가되면 접지극 주변에서 이온화 현상이 발생하게 된다. 지중이나 수중에서의 이온화 현상은 접지 시스템의 에너지적인 특성에 의해 영향을 받는다. 이 논문의 목적은 축소된 전해 수조를 이용하여 임펄스 전압에 의한 접지시스템의 과도특성을 파악하는데 있다. 매틀랩 프로그램을 활용하여 이온화에 의한 전위저감과 방출된 에너지를 측정하여 정량적인 분석을 수행하였다. 접지극 끝단의 최대 전압은 물의 저항률과 Marx형 전압발생장치의 충전전압에 따라 다양하게 나타났다. 접지극 끝단의 전위는 절연파괴전압에 이르기 전 인가전압에서 대략 절반까지 감소하였다. 또한 절연파괴가 발생하기 전 인가된 에너지의 절반 이상의 에너지가 이온화에 의해 접지극을 통하여 방출되었다.