• 제목/요약/키워드: Markus

검색결과 104건 처리시간 0.036초

Mastectomy in female-to-male transgender patients: A single-center 24-year retrospective analysis

  • Kuhn, Shafreena;Keval, Seirah;Sader, Robert;Kuenzlen, Lara;Kiehlmann, Marcus;Djedovic, Gabriel;Bozkurt, Ahmet;Rieger, Ulrich Michael
    • Archives of Plastic Surgery
    • /
    • 제46권5호
    • /
    • pp.433-440
    • /
    • 2019
  • Background Mastectomy in male transgender patients is an important (and often the first) step toward physical manhood. At our department, mastectomies in transgender patients have been performed for several decades. Methods Recorded data were collected and analyzed for all male transgender patients undergoing mastectomy over a period of 24 years at our department. Results In total, 268 gender-reassigning mastectomies were performed. Several different mastectomy techniques (areolar incision, n=172; sub-mammary incision, n=96) were used according to patients' habitus and breast features. Corresponding to algorithms presented in the current literature, certain breast qualities were matched with a particular mastectomy technique. Overall, small breasts with marginal ptosis and good skin elasticity allowed small areolar incisions as a method of access for glandular removal. In contrast, large breasts and those with heavy ptosis or poor skin elasticity often required larger incisions for breast amputation. The secondary correction rate (38%) was high for gender reassignment mastectomy, as is also reflected by data in the current literature. Secondary correction frequently involved revision of chest wall recontouring, suggesting inadequate removal of the mammary tissue, as well as scar revision, which may reflect intense traction during wound healing (36%). Secondary corrections were performed more often after using small areolar incision techniques (48%) than after using large sub-mammary incisions (21%). Conclusions Choosing the suitable mastectomy technique for each patient requires careful individual evaluation of breast features such as size, degree of ptosis, and skin elasticity in order to maximize patient satisfaction and minimize secondary revisions.

전자선 선질 R50=1.0과 1.4 g/cm2에 대한 PTW-Markus 전리함의 선질보정인자 결정에 관한 연구 (Determination of Beam Quality Correction Factors for the PTW-Markus Chamber for Electron Beam Qualities R50=1.0 and 1.4 g/cm2)

  • 김미영;이동주;문영민;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.178-184
    • /
    • 2015
  • 마커스 전리함은 치료용 전자선의 흡수선량 측정에 널리 사용되는 소형 평행 평판형 전리함이다. 특히 TRS-398 프로토콜에서는 $R_{50}<4.0g/cm^2$ (약 10 MeV 이하)에서 평행 평판형 전리함의 사용을 권고하고 있다. 그러나 TRS-398 프로토콜에서 $R_{50}<2.0g/cm^2$ (약 4 MeV 이하)에 대한 선질보정인자($k_{Q,Q_0}$)가 없어 낮은 에너지에 대한 선량측정이 필요한 경우에 마커스 전리함을 사용할 수 없다. 본 연구에서는 몬테칼로 계산(DOSRZnrc/EGSnrc)과 선량학적 계산을 이용하여 전자선 선질 $R_{50}=1.0$, 1.4, 2.0, 2.5, 3.0, $5.0g/cm^2$에 대하여 마커스 전리함(PTW-M34045)에 대한 $k_{Q,Q_0}$를 결정하였다. 본 연구에서는 결정된 $k_{Q,Q_0}$에 대해 TRS-398 및 TG-51 프로토콜의 자료와 알려진 자료들을 이용하여 평가하였다.

연약지반 TBM 터널 막장지보 계산방법 해설 (Commentary on Soft Ground TBM Tunnel Face Support Calculation Methods)

  • 지왕률;유정현
    • 터널과지하공간
    • /
    • 제28권2호
    • /
    • pp.186-192
    • /
    • 2018
  • 최근에 독일터널위원회(German Tunnelling Committee DAUB)에서 TBM 막장지보의 새로운 계산법을 발표하였다. 이에 따라 보쿰시에 위치한 Ruhr 대학의 Zdenek Zizka와 Markus Thewes가 새로운 방법에 대해 활발한 논의를 하였다. 이러한 권유사항은 다양한 터널막장 지보 계산방법에서 지반조건에 따라 가장 적절한 계산법을 선정하는데 도움이 된다.또한, 막장에 적용되는 지반압 혹은 지하수압에 따른 막장안정 계산법들을 논하였다. 이 보고서에는 Zdenek Zizak and Markus Thewes의 터널 막장지보 계산법에 대한 기술적 논의를 구체적으로 설명하는 것이 목적이다.

고에너지 전자선에 대한 표준측정법간의 비교 (Comparison of Dosimetry Protocols in High Energy Electron Beams)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.267-276
    • /
    • 1998
  • 팬톰내에 삽입되는 전리함은 전자 플루언스의 교란을 최소화하는 기하학적 구조를 갖는 것이 바람직한데 평행평판형 전리함은 다른 어떤 전리함보다도 이러한 조건을 잘 만족시킨다. 이러한 이유로 IAEA 표준측정법에서는 표면 평균 에너지가 10 MeV 이하인 전자선 측정시 평행평판형 전리함의 사용을 권고하고 있으나 일반적으로 편의상 원통형 전리함을 많이 사용하고 있는 실정이다. 본 연구에서는 네 가지 다른 표준 측정법 즉 1)원통형 전리함을 사용한 IAEA 표준 측정법 2)원통형 전리함을 사용한 TG-21 표준 측정법 3)평행평판형 전리함을 사용한 Markus 측정법 4)평행평판형 전리함을 원통형 전리함에 대하여 교정한 TG 39 측정법을 사용하여 서로 다른 측정법과 전리함의 차이에 의한 선량 값의 변화를 알아보고자 한다. Siemens KD-2 선형가속기에서 발생하는 고에너지 전자선(6,9,12,15,18 MeV)을 이용하여 3차원 전산화 물팬톰과 0.125 cc 전리함을 사용하여 각 에너지별로 l0$\times$10 $cm^2$ cone size의 심부선량백분율을 구하였다. 고체 물팬톰내에서 Farmer type 0.6cc 원통형 전리함을 사용하여 IAEA 표준 측정법과 TG-21 표준 측정법에 의해서 각 에너지별로 흡수선량을 측정하였다. 평행평판형 전리함(Markus Chamber)을 사용하여 Markus 측정법에 의해서 각 에너지별로 흡수선량을 측정하였다. 전자선 에너지 18 MeV를 사용하여 원통형 전리함에 대한 평행평판형 전리함의 교정계수를 얻고 TG 39 측정법에 의해서 각 에너지별로 흡수선량을 측정하였다. Cone size 는 l0$\times$10 $cm^2$ 이었고 측정점의 깊이는 d$_{max}$ 이었다. IAEA 표준 측정법과 TG 21 표준 측정법은 18 MeV 에 대하여 0.9 % 의 차이가 나타났고 그 외의 에너지 영역에서 0.7% 이내로 비교적 잘 일치하였다. Markus 측정법과 TG 39 측정법은 18 MeV 와 6 MeV 에 대하여 각각 $\pm$0.8 % 의 차이가 나타났고 그 외의 에너지 영역에서 0.5 % 이내로 잘 일치하였다. 원통형 전리함과 평행평판형 전리함을 이용한 측정법간의 차이는 18 MeV 에서 1.6 % 까지 나타나므로 주의를 요하며 TG 39 측정법에서 제시한 다른 측정방법을 사용하여 측정을 하여 교정계수를 얻을 필요가 있을 것으로 생각된다.다.

  • PDF

유한요소법을 이용한 샌드위치형 감쇠 보구조물의 진동해석 (Vibration Analysis of Damped Sandwich Beam Using Finite Element Method)

  • 서영수;정의봉;신준엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.978-981
    • /
    • 2005
  • The vibration analysis of damped sandwich beam is conducted using finite element method. The equation of motion presented by Mead and Markus is used to formulate FEM. Also as the thickness of the core in the damped sandwich beam goes to zero, conventional beam theory based on the transformed-section method and the equation of Mead and Markus are compared. According to the change of thickness and loss factor of the core, the forced frequency response of beam is calculated and discussed. And then using the half-power band width method, the damping ratio of each mode is calculated and discussed about each case.

  • PDF

두경부암 치료를 위한 6MV X-선 산란판의 제작과 산란분포 측정 (Skin Dose Distributions with Spoiler of 6MV x-ray for Head and Neck Tumor)

  • 이호수;이종걸;이병준
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.176-184
    • /
    • 1995
  • It is very useful benefits to use the megavoltage photon beams in deep site tumor radiotherapy for skin sparing effects. But, In some cases of head and mock tumors, it is often necessary to use spoiler for rapid buildup on skin region. A spoiler with tissue equivalent material to be moved between the patients and the collimator can increase or control the skin dose and buildup region due to position and thickness of the spoiler was measured. Then, the effect of spoiler on skin dose and build up region in protruded tumor of head and neck was evaluated quantitatively. The measurements were abtained with PTW 2334 chamber (Markus type) on a polystylene phantom for 6MV x-ray from an accelerator.

  • PDF

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰 (Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays)

  • 이용하;박경란;이종영;이익재;박영우;이강규
    • Radiation Oncology Journal
    • /
    • 제21권4호
    • /
    • pp.322-329
    • /
    • 2003
  • 목적 .: 고에너지 X-선의 표면 선량과 선량보강(build-up) 영역에서의 선량 분포는 일반적으로 방사선 계측에 사용되는 전리함 측정기로는 정확한 선량 분포를 얻기가 매우 어렵다. 본 연구는 고에너지 X-선 선량 계측에 보편적으로 사용되고 있는 여러 측정기를 이용하여 팬톰 표면에서의 흡수선량과 최대 선량 지점(d$_{max}$)을 측정하여 측정기 사이의 정확성을 비교 분석하고, 각 치료 기관에서 보편적으로 사용되는 측정기 중 표면 선량 측정에 적절한 측정장치를 제안하고 그 유용성을 제시하고자 한다. 대상 및 방법 : 본 실험에서는 6 MV와 IS MV X-선에 대해 조사면이 10$\times$10 cm$^{2}$, SSD=100 cm에서 TLD, 팀블형전리함(thimble type ion chamber), 다이오드 검출기, 다이아몬드 검출기와 Markus 평행판 전리함 등을 이용하여 심부선량백분율(percent depth dose: PDD)을 측정하여, 표면 선량(suface dose)과 최대 선량 지점(dnu)을 비교 분석하고, 또한 TLD 측정 시와 동일 조건으로 Monte Cario 계산을 실행하여 TLD의 측정 결과와 비교하였다. 결과: 6 WV와 IS MV X-선에 대해 Markus 평행판 전리함을 이용하여 측정한 표면 선량은 각각 29.31$\%$와 23.36$\%$으로 측정되었으며, TLD는 37.17$\%$와 24.06$\%$, 다이아몬드 검출기는 34.78$\%$와 24.06$\%$, 다이오드 검출기는 38.18$\%$와 27.8$\%$, 팀블형 전리함은 47.92$\%$와 36.06$\%$ 였으며, Monte Cario 계산에 의한 표면 선량 값은 S MV X-선에 대해 TLD 측정 시와 동일한 조건으로 팬톰 내에 가상적인 TLD를 삽입한 경우 36.22$\%$로 실제 측정값 37.17$\%$와 유사하였다. 최대 선량 지점의 깊이는 모든 측정기에서 6 MV X-선에 대하여 14$\~$16 mm, IS MV X-선에서는 27$\~$29 mm사이의 측정기에 따라 작은 차이를 보였다. 결론 : 표면 선량의 경우에는 측정기에 따라 현저한 차이를 보였으며 Markus 평행판 전리함이 사용된 측정기 중가장 정확한 결과를 보였고, 팀블형 전리함의 경우 다른 측정기에 비해 약 10$\%$ 이상 높은 선량을 보여 피부 표면에 가까이 위치한 종양에 대한 방사선 치료 계뵉 시에는 임상에서 가장 보편적으로 사용되고 있는 팀블형 전리함의 선량 값을 그대로 사용하기에는 많은 오류가 발생하므로 가능한 표면 선량 측정에 적절한 측정기를 선택하여 사용하거나 측정기 특성을 고려한 보정이 필요할 것으로 생각된다. 최대 선량 지점(d$_{max}$)의 결과는 모든 측정기에서 비슷한 결과를 나타내고 있어 본 실험에서 사용한 모든 측정기는 그 특성에 상관없이 최대 선량 지점 측정에 사용이 가능함을 알 수 있었다.