• Title/Summary/Keyword: Marine pump

Search Result 288, Processing Time 0.028 seconds

Heat Transfer Characteristics of Inclined Helical Coil Type Heat Exchanger (경사진 헬리컬 코일 열교환기의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Jeon, Min-Ju;Jang, Seong-Il;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.707-714
    • /
    • 2007
  • The heat transfer coefficient and Pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45mm inner diameter. The refrigerant mass fluxes were varied from 200 to $600[kg/m^2s]$ and the inlet Pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increases with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those Predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However, at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al. correlation. Therefore. various experiments in the inclined helical coil tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in the inclined helical coil tubes.

A Study on the Analysis of a Negative Pressure in the Seawater Line of a Main Centeral Cooler (MCC) for a Large LNG Ship (대형 LNG선 주냉각기 해수라인의 부압현상 해석에 관한 연구)

  • Jin, Chang-Fu;SaGong, Woon-Gon;Kim, Jong-Gyu;Kim, Chung-Sik;Song, Young-Ho;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.893-900
    • /
    • 2008
  • The heat exchangers in the ships have been changed from the conventional shell & tube type to the plate type due to some merits as a compactness, a high thermal efficiency and a light-weight. In recent. it is reported that the vacuum phenomena were occurred in the seawater outlet piping of a main central cooler (MCC) on the ships. From the viewpoints of a common sense, the vacuum pressure in the seawater piping is rare event and difficult to be convinced because the seawater is pumped into the piping by a seawater pump with a high discharge head. However, the occurrence of a vacuum pressure in the seawater line of an MCC is real situation and often gives a severe damage to a rubber gasket of an MCC with a plate type heat transfer area. In this study, we analyzed the vacuum pressure in the seawater line of an MCC by using the simpl Bernoulli's equation and found that the vacuum pressure in the seawater line of an MCC is inevitable untill the installation postion of an MCC is not lowered.

A Study on the Diffuser Inlet Shape of Thermocompressor for MED Desalination Plant (다중효용 담수설비용 열압축기의 디퓨져 입구부 형상에 관한 연구)

  • Jin, Chang-Fu;Song, Young-Ho;Kim, Kyung-Keun;Park, Gi-Tae;Chung, Han-Shik;Choi, Du-Youl
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.869-876
    • /
    • 2008
  • A thermocompressor is the equipment which compresses a vapor to a desired discharge pressure. Since it was first used as the evacuation pump for a surface condenser, it has been widely adopted for energy saving systems due to its high working confidence. In the present study, the geometrical analysis of the shape between the jet nozzle and the diffuser inlet, the drag force was calculated by means of the integrated equation of motion and the computational fluid dynamic (CFD) package called FLUENT. The computer simulations were performed to investigate the effects by the various suction flow rates, the distance from jet nozzle outlet to the diffuser inlet and the dimensions of the diffuser inlet section through the iterative calculation. In addition, the results from the CFD analysis on the thermocompressor and the experiments were compared for the verification of the CFD results. In the case of a jet nozzle, the results from the CFD analysis showed a good agreement with the experimental results. Furthermore, in this study, a special attention was paid on the performance of the thermocompressor by varying the diffuser convergence angle of $0.0^{\circ}$, $0.5^{\circ}$, $1.0^{\circ}$, $2.0^{\circ}$, $3.5^{\circ}$ and $4.5^{\circ}$. With the increase of the diffuser convergence angle. the suction capacity was improved up to the degree of $1.0^{\circ}$ while it was decreased over the degree of $1.0^{\circ}$.

A Study on the Release of Hatch Cover in Sand Carriers (모래운반선의 창구덮개 면제를 위한 시설기준에 관한 연구)

  • Jung, Chang-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.439-445
    • /
    • 2012
  • Only the sand carriers fitted with hopper doors can remove their hatch covers in current regulations. However, there is no sand carriers fitted with hopper doors in korea. Through the analysis of accidents, inspection of equipment installed on ships, and evaluation of stability and seakeeping performance concerning the sand carriers, it is expected that the current exemption requirement is modified for hatch covers for sand carriers. As the result, this paper proposed the removal of hatch covers and be fitted by tarpaulin instead to protect water ingress into the holds. This can be done by making the holds smaller designed to be filled full until the top of the hold without exceeding loadline. Also, the bilge pumps should have the sufficient capacity of pumping water out in the early stage of sand-water mixture to wetted condition in approximately 1 hour and be operationally ready in every voyage conditions.

Design and Implementation of Unmanned Surface Vehicle JEROS for Jellyfish Removal (해파리 퇴치용 자율 수상 로봇의 설계 및 구현)

  • Kim, Donghoon;Shin, Jae-Uk;Kim, Hyongjin;Kim, Hanguen;Lee, Donghwa;Lee, Seung-Mok;Myung, Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • Recently, the number of jellyfish has been rapidly grown because of the global warming, the increase of marine structures, pollution, and etc. The increased jellyfish is a threat to the marine ecosystem and induces a huge damage to fishery industries, seaside power plants, and beach industries. To overcome this problem, a manual jellyfish dissecting device and pump system for jellyfish removal have been developed by researchers. However, the systems need too many human operators and their benefit to cost is not so good. Thus, in this paper, the design, implementation, and experiments of autonomous jellyfish removal robot system, named JEROS, have been presented. The JEROS consists of an unmanned surface vehicle (USV), a device for jellyfish removal, an electrical control system, an autonomous navigation system, and a vision-based jellyfish detection system. The USV was designed as a twin hull-type ship, and a jellyfish removal device consists of a net for gathering jellyfish and a blades-equipped propeller for dissecting jellyfish. The autonomous navigation system starts by generating an efficient path for jellyfish removal when the location of jellyfish is received from a remote server or recognized by a vision system. The location of JEROS is estimated by IMU (Inertial Measurement Unit) and GPS, and jellyfish is eliminated while tracking the path. The performance of the vision-based jellyfish recognition, navigation, and jellyfish removal was demonstrated through field tests in the Masan and Jindong harbors in the southern coast of Korea.

Model Development of Aeration System using Small Wind Turbine (소형 풍력 터빈을 이용한 폭기시스템 모델 개발)

  • Kim, Myoung-Jun;Chea, Gyu-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • In recent years, the crisis of energy is growing seriously and also the contamination of ecology has been reverberated as international problem. The social concerns on energy crisis have been growing for the last several years and also the interests in new and renewable energy have been increased. Therefore, in order to solving these problems, as solution of one, this paper is investigated using the aeration system at the fish farm, etc from nature energy such as wind power. This study suggests the fundamental data of designing for these similar apparatus and examines the parameters of wind velocity and wind receiving area. Especially, the water outlet position was mainly investigated with optimum outlet angle of wind pump.

A Study of the High Efficiency Sea Water Cooling System for the Propulsion Diesel Engine of Warships (함정 추진디젤기관의 고효율 해수냉각시스템에 관한 연구)

  • Kang, Byoung-Soo;Lim, Young-Soo;Jo, Kwan-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.468-472
    • /
    • 2015
  • Recently, there has been increasing interest in the efficient use of energy due to policies related to the reduction of greenhouse gas. This paper suggests a highly efficient sea water cooling system for the load-dependent control of a seawater pump depending on the load, to improve energy efficiency of the warship. This study models the propulsion diesel engine and simulation reflecting the characteristics of the warship operation state that checked the performance of high efficiency sea water cooling system. The simulation results revealed the cooling system of high efficiency with energy savings of approximately 53% compared to the existing cooling systems. These results can be used to improve the performance of the cooling system of the warship propulsion diesel engine in the future.

Temperature Variation of Exhaust Gas in Diesel Generator for Low Pressure SCR (저압 SCR을 위한 디젤발전기 배기가스 온도 변화)

  • Hong, Chul Hyun;Lee, Chang Min;Lee, Sang Duk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.355-362
    • /
    • 2021
  • To facilitate low-pressure selective catalyst reduction (L.P SCR), a high exhaust-gas temperature of a four-stroke diesel engine for a ship's generator is required. This study aimed at reducing the exhaust-gas temperature by adjusting the valve open-close timing and fuel injection timing to satisfy the operating conditions of L.P SCR and prevent accidents associated with the generator engine due to high temperature. To lower exhaust-gas temperature, the angle of the camshaft was adjusted and the shim of the fuel injection pump was added. As a result, the maximum explosion pressure increased and the average of the turbocharger outlet temperature dropped. Considering the heat loss from the turbocharger outlet to the SCR inlet, the operation condition for L.P SCR was satisfied with 290 ℃. The study demonstrates that safe operation of a diesel generator can be achieved by lowering the exhaust-gas temperature.

A Study on Development of Hot Forged Component of Hot Tool Steel DH32 (열간공구강 DH32 소재의 열간단조품 개발에 관한 연구)

  • Jang, Jin-Hyung;Kim, Hyun-Su;Kim, Jong-Hyeon;Kim, Hyun-Pil;Kim, Young-Jo
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.39-44
    • /
    • 2012
  • Hot tool steel, in general, has not been used as a material in hot forging. However such a hot tool steel is recently applied to forging materials by recent forging technology. DH32 is known as a kind of hot tool steels, which is developed for characteristics of excellent strength and toughness in high temperature. Feasibility of DH32 to hot forging material has been researched to develop the hot forging technology of a plunger used for a large-sized marine fuel pump. Hot compression experimental works were performed to investigate the hot strain characteristic of DH32 and with the experimental results FE simulations were also conducted for the design of forging processes and preform. It is found out through the hot compression experimental works that DH32 has a hot brittleness at more than $1150^{\circ}C$.

  • PDF

Performance Improvement through the Remanufacturing Process Analysis of Industrial Hydraulic Pumps (산업용 유압펌프의 재제조 공정분석을 통한 성능개선)

  • Park, Sang Jin;Son, Woo Hyun;Lee, Kyu Chang;Mok, Hak Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.181-189
    • /
    • 2020
  • As production, distribution, consumption and processing increase with the development of industrial societies, the importance of resource depletion and environmental problems is increasing day by day. This has led to increased research and interest in remanufacturing that can satisfy both environmental and economic aspects. Currently, the remanufacturing industry is progressed in Korea with automobile parts with as the central figure, and it needs to be expanded into various areas. In this study, the failure type analysis and FMEA were performed on the hydraulic pumps used in construction and industrial sites for the development of the standard remanufacturing process plan, and the actual disassembly and reassembly process was carried out. Remanufacturing products were manufactured through the analysis contents and drawing process, performance tests were conducted in accordance with RS B1501 criteria to evaluate performance, and all of these products passed the test criteria.