• 제목/요약/키워드: Marine HVAC

검색결과 15건 처리시간 0.02초

선박 공조닥트의 특성분석에 관한 사례 연구 - 유지관리용 로봇의 이동 알고리즘 개발을 위한 분석 - (A Case Study on the Analysis of Characteristics of Marine HVAC Duct - For the Development of Maintenance Robot's Movement Algorithm -)

  • 황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.211-217
    • /
    • 2006
  • This study is focused on the analysis of the characteristics of marine HVAC duct. These results will be applied to develope a robot which is for maintaining a cabin comfort, convenience and healthy through HVAC duct. The followings are the results of this study. (1) The evaluated items which proposed by at the view point of robot's function can be adapted to other vessels for the same purpose, (2) For the case of round type duct. the maximized conditions which robot has to have are straight length of 40.152mm, inclination of $45^{\circ}$. horizontal bending of $90^{\circ}$. increasing diameter of 1.28 times, and 0.625 times decreasing diameter in branch. (3) For the case of rectangular type duct. the maximized conditions are straight length of 15.987mm. aspect ratio of 4.17:1, inclination of $18.92^{\circ}$. horizontal bending of $90^{\circ}$, and 0.65 times decreasing diameter in branch.

WORK BARGE 선의 냉동.공조 SYSTEM (HVAC & Refrigeration System for Work Barge Vessel)

  • 남임우;정재천;김봉제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.583-590
    • /
    • 2008
  • 최근 작업자 숙소 및 이송용 외에 작업용으로 사용 가능한 Barge선의 일종인 Accommodation Work Barge 선의 건조량이 증가 추세인 바 현재 중국에서 건조 중인 해당 선박의 HVAC & Refrigeration system에 대하여 정리하였다. 본 시스템은 R404A Direct expansion 냉각방식 (직접팽창방식)이 적용되었으며 HVAC system 중 Air conditioning 부분에 대해서는 선박의 각 Deck 기준으로 Zoning 하여 개별적인 Air handling unit와 Condensing unit를 구성하였으며 (각 unit의 용량은 필요용량의 100%), 냉동 창고의 Refrigeration system은 해당 격실 (육고, 어고, 야채고)에 각각 Unit cooler를 설치하고, Condensing unit를 기계실에 설치하였다. 장비는 전체 용량 100%에 대하여 항시 운전하는 100% 용량의 장비와 비상시에 운전하는 100% 용량의 예비 장비로 구성된다. 냉동 창고에 인접한 Dry provision store는 냉동 창고와는 별개로 중앙 공조기로부터의 냉각 공기를 이용하여 Spot cooling하였다. 본 System의 구성에 대한 장점 및 단점은 아래와 같다. 1. Air conditioning system이 각 Zone에 대하여 구성되므로 각 Zone에 대하여 제어가 가능하다. 2. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 냉매 배관의 길이가 짧다. 3. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 실내의 Maintenance space 상에 여유가 없다.

  • PDF

신조 운항실습선의 봄철 실내 온열환경 실측평가 (A Measurement and Evaluation on the Indoor Thermal Conditions in Spring of a New Training ship)

  • 신동걸;이진욱;이형기;박윤철;황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.939-946
    • /
    • 2007
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.

신조 운항실습선의 여름철 실내 온열환경 실측평가 (A Measurement and Evaluation on the Indoor Thermal Conditions in Summer of a New Training ship)

  • 신동걸;이진욱;이형기;황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.276-283
    • /
    • 2008
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those which are supplied and controlled by marine HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured like previous report on a newly-launched training ship during 25th through 27th of July, 2007. Followings are the results of this study. (1)The air supply volumes to each cabins are measured 250CMH(Recreation room), 800CMH(Conference room), 1.000CMH(Bridge), 5,100CMH(Lecture room) respectively. (2)The temperatures are maintained at $21{\sim}27^{\circ}C$ in almost cabins through measuring period, but the temperatures are fluctuated over ${\pm}4^{\circ}C$ at the bridge and conference room. (3)The relative humidities are shown between $40{\sim}60%$ known as comfort conditions, but the conference room is needed to dehumidified because of over 70% humidity. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of temperature diversities, only 32% among the measured data are satisfied with the comfort standard range proposed by ASHREA.

A Seasonal Indoor Thermal Conditions of a Newly-launched Training Ship

  • Hwang, Kwang-Il;Shin, Dong-Keol;Lee, Jin-Uk;Lee, Sang-Il
    • 한국항해항만학회지
    • /
    • 제33권4호
    • /
    • pp.289-294
    • /
    • 2009
  • The living performances of crews and passengers in cabins have been less received attention, while Korea is a top leading country in ship building industry. To develop a high value added ships like 5-star cruisers, researches on the comfort and productivity in cabins should be carried out with urgent. The purpose of this study is to measure and analyze of the ship's indoor thermal conditions in spring, summer and winter, and also to compare the seasonal differences, of which conditions are supplied from and controlled by marine HVAC The temperature, humidity and air supply volume of 5 different needs of cabins on a training ship were measured through a year, which was launched at Dec. 2005 and totally 246 crews can go on board for education. The following results were obtained: (1)In the spring, the temperature in cabins was measured as $20{\sim}25^{\circ}C$ and humidity was below 30%. (2)In the summer, the temperatures was controlled at $21{\sim}27^{\circ}C$ in almost cabins and humidity was between $40{\sim}60%$ which is known as comfort conditions. (3)In the winter, temperature and humidity was maintained between $19{\sim}26^{\circ}C$, and humidity was between $10{\sim}50%$. (4)It is clear that the humidity conditions in cabins are not properly controlled at all through a year to satisfy the Comfort Standards provided by ASHRAE and/or ISO, In conclusion, humidification and dehumidification of cabins must be treated with importance for more comfort living and working environments for crews and passengers.

빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발 (Development of control and monitoring board for building energy saving valve)

  • 오진석;강영민;장재희
    • 한국정보통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.895-902
    • /
    • 2018
  • 건물에 의한 에너지 소비량은 미국 및 일본 등 선진국에서는 전체 국가 에너지 소비량의 40%에 육박하고 있으며, 우리나라에서도 전체 에너지 소비량의 24%를 차지하고 있는 것으로 보고되고 있다. 빌딩에서 HVAC (Heating, Ventilation, and Air conditioning)은 필요 열량에 따라 냉각 유량을 자유롭게 제어할 수 없기 때문에 에너지가 효율적으로 사용되지 않고 있다. 따라서 에너지 절감 밸브를 사용함으로써 유량을 필요한 열량만큼 제어하여 에너지를 절감할 수 있다. 본 논문에서는 에너지 절감 밸브를 개발하기 위한 기본적인 상태를 정의하고 저전력, 고 가성비의 PIC 프로세서 기반의 빌딩 에너지 절감 밸브용 제어 및 감시 보드를 개발한다. 설계된 보드는 온도차 측정을 위한 2개의 온도 값과 유량 값 및 계산된 열량에 관한 정보를 실시간으로 디스플레이 및 전송한다. 개발된 제어 감시 보드는 향후 밸브의 상태를 실시간으로 파악하거나 해상용 밸브 등을 개발하는 데 유용하게 사용될 것이다.

590인승 Ro-Pax형(型) 연안여객선의 선실 내 봄철 온열환경 측정평가 (A Measurement and Evaluation of Indoor Thermal Conditions in Spring of a Coastal Passenger Ship - 590-Passenger Ro-Pax Type)

  • 황광일;신동걸;김은수;도요한;최윤석;최정열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1170-1177
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions in the spring of a korean coastal passenger ship which is 590-passenger Ro-Pax type built at 1997. Especially this study has focussed on the relations between the diffuser open ratio, which can be controlled by 12 steps, and the comfort. Followings are the results of this study. (1) The supply air volume to cabins are maximum 4.3 and 2 times more than design quantity when the diffusers in cabins are open 100% and 50%, respectively. (2) Regardless of diffuser open ratio, the supply air maintains constantly high temperature and below 10% of relative humidity through the experimental days. (3) All the cabins are not satisfied with the ASHRAE comfort criterion at the condition of 100% and 50% of diffuser open ratio, because of high temperature and low relative humidity. (4) At a low diffuser open ratio, number of cabins which satisfy the ASHRAE comfort criterion are increased. (5) Humidifying and dehumidifying, and hvac control system of each cabin must be reviewed and studied at the view of passengers to service more comfort environments.

선박용 대형 덕트의 소음 특성 전산해석 연구 (Computational Analysis on the Noise Characteristics of Ship Large Duct)

  • 송지훈;홍석윤;이이수;권현웅
    • 해양환경안전학회지
    • /
    • 제21권6호
    • /
    • pp.751-758
    • /
    • 2015
  • 공조시스템의 소음 예측은 주로 NEBB에서 제안한 경험적인 방법에 의해 수행된다. 그러나, NEBB에서 제안한 방법은 선박에만 있는 대형 덕트의 요소를 반영하지 못하므로 선박에 적용하는데 한계가 있다. 본 논문에서는 선박용 대형 덕트의 소음 예측을 위한 전산해석방법을 연구하였다. 경계요소법을 사용하여 대형 덕트의 단위 길이당 소음 감소량에 대한 추정식을 개발하였고, 경계요소법과 전산유체역학을 사용하여 보강재가 설치된 대형 덕트에서의 유동기인소음을 예측하였다. 유입 유속이 10m/s, 보강재의 종류가 200플랫 바인 경우 100 dB 이상의 큰 소음이 발생하는 것을 알 수 있었다. 또한, 경계요소법과 유한요소법을 사용하여 덕트 투과 소음을 예측하였다. 덕트 내부와 외부의 음압 값 차이는 대략 10~15 dB정도 인 것을 알 수 있었다. 이를 통해 조선소에서는 대형 덕트를 포함한 선박 HVAC 소음 예측을 할 수 있을 것으로 기대한다.

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

HVAC 덕트 내에 설치된 광촉매코팅 모듈의 형상이 압력강하에 미치는 영향 (A Numerical Analysis of the Pressure Drop according to the Shape of TiO2 Photocatalyst-coated Module in a HVAC Duct)

  • 황광일;구재혁;김다혜;이현인;최영국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1055-1062
    • /
    • 2011
  • 본 연구는 실내 환경오염물질 제거성능 향상을 목적으로 공조기 덕트 내에 착탈 가능한 광촉매코팅 모듈의 형상을 개발하는 것이다. 본 연구에서는 광촉매코팅 모듈로 적용 가능한 사각, 원, 마름모등 기둥형 세 가지와 마름모, 사각 등 휜부착형 두 가지 등 총 다섯 가지 형상의 모델을 개발하였다. 속도변화에 대한 수치해석결과, 대부분 모듈 전후 0.3m 범위 이내에서 속도변화가 발생하였지만, 마름모기둥형(Type A-3)의 경우에는 모듈 뒷부분 0.4m까지 속도가 변하였고 모듈 전후에서의 속도 변동 폭이 가장 컸다. 다섯 가지 형상 중 속도변화가 가장 안정적인 것은 마름모 휜부착형(Type B-1)으로 평가되었다. 또한 국부적인 압력강하에 대한 비교에서도 비슷한 결과가 도출되었다. 즉, 다른 형상에 비해 마름모기둥형(Type A-3)의 압력강하계수가 2.44로 가장 크게 나타났으며, 마름모 휜부착형(Type B-1)은 0.59로 가장 변화량이 적었다. 한편, 모듈 수 증가에 따른 덕트 내 유동해석에서는, 모듈 수 증가에 따라 기류 충돌이 발생하여 압력이 증가하였다. 특히 모듈 수가 3개 이상이 되면 모듈 뒷부분은 변화가 없지만 앞부분에서 압력이 상승함을 알 수 있었다.