• Title/Summary/Keyword: Margins

Search Result 1,075, Processing Time 0.023 seconds

Effect of 38% carbamide peroxide on the microleakage of silorane-based versus methacrylate-based composite restorations

  • Hashemi Kamangar, Sedighe Sadat;Ghavam, Maryam;Mahinfar, Nazanin;Pourhashemi, Seyed Jalal
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.172-179
    • /
    • 2014
  • Objectives: This study aimed to assess the effect of 38% carbamide peroxide on the microleakage of class V cavities restored with either a silorane-based composite or two methacrylate-based composites. Materials and Methods: A total of 96 class V cavities were prepared on the buccal surface of extracted human teeth with both enamel and dentin margins and were randomly assigned into three groups of Filtek P90 (3M-ESPE) + P90 system adhesive (3M-ESPE)(group A), Filtek Z250 (3M-ESPE) + Adper Prompt L-Pop (3M-ESPE)(group B) and Filtek Z350XT (3M-ESPE) + Adper Prompt L-Pop (group C). Half of the teeth were randomly underwent bleaching (38% carbamide peroxide, Day White, Discus Dental, applying for 15 min, twice a day for 14 day) while the remaining half (control) were not bleached. Dye penetration was measured following immersion in basic fuchsine. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests at a level of 0.05. Results: No significant differences were found between composites in the control groups in enamel (p = 0.171) or dentin (p = 0.094) margins. After bleaching, microleakage of Z250 (in enamel [p = 0.867] or dentin [p = 0.590] margins) and Z350 (in enamel [p = 0.445] or dentin [p = 0.591]margins) did not change significantly, but the microleakage of P90 significantly increased in both enamel (p = 0.042) and dentin (p = 0.002) margins. Conclusions: No significant differences were noted between the bleached and control subgroups of two methacrylate-based composites in enamel or dentin margins. Microleakage of silorane-based composite significantly increased after bleaching.

The delay margin of the LQG regulator

  • Kim, Sang-Woo;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.749-752
    • /
    • 1988
  • In this paper, the delay margins of the LQ and the LQG regulators are obtained in the time domain. These margins are represented in terms of the singular values of system matrices and the solutions of a Riccati equation and a Lyapunov one. And their asymptotical properties when gains tend to infinity are investigated.

  • PDF

Comparative Study of Indocyanine Green Intravenous Injection and the Inflation-Deflation Method for Assessing Resection Margins in Segmentectomy for Lung Cancer: A Single-Center Retrospective Study

  • Seon Yong Bae;Taeyoung Yun;Ji Hyeon Park;Bubse Na;Kwon Joong Na;Samina Park;Hyun Joo, Lee;In Kyu Park;Chang Hyun Kang;Young Tae Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.5
    • /
    • pp.450-457
    • /
    • 2024
  • Background: The inflation-deflation (ID) method has long been the standard for intraoperative margin assessment in segmentectomy. However, with advancements in vision technology, the use of near-infrared mapping with indocyanine green (ICG) has become increasingly common. This study was conducted to compare the perioperative outcomes and resection margins achieved using these methods. Methods: This retrospective study included patients who underwent direct segmentectomy for clinical stage I lung cancer between January 2018 and September 2022. We compared perioperative factors, including bronchial and parenchymal resection margins, according to the margin assessment method and the type of segmentectomy performed. Since the ICG approach was adopted in April 2021, we also examined a recent subgroup of patients treated from then onward. Results: A total of 319 segmentectomies were performed. ID and ICG were utilized for 261 (81.8%) and 58 (18.2%) patients, respectively. Following April 2021, 61 patients (51.3%) were treated with ID, while 58 (48.7%) received ICG. We observed no significant difference in resection margins between ID and ICG for bronchial (2.7 cm vs. 2.3 cm, p=0.07) or parenchymal (2.5 cm vs. 2.3 cm, p=0.46) margins. Additionally, the length of hospitalization and the complication rate were comparable between groups. Analysis of the recent subgroup confirmed these findings, showing no significant differences in resection margins (bronchial: 2.6 cm vs. 2.3 cm, p=0.25; parenchymal: 2.4 cm vs. 2.3 cm, p=0.75), length of hospitalization, or complication rate. Conclusion: The perioperative outcomes and resection margins achieved using ID and ICG were comparable, suggesting that both methods can safely guide segmentectomy procedures.

Comparison of Two Nondestructive Methods of Leaf Area Estimation

  • Woo, Hyo-Jin;Park, Yong-Mok
    • Journal of Ecology and Environment
    • /
    • v.32 no.1
    • /
    • pp.61-65
    • /
    • 2009
  • We compared two nondestructive methods for leaf area estimation using leaves of 16 common plant species classified into six types depending on leaf shape. Relatively good linear relationships between actual leaf area (LA) and leaf length (L), width (W), or the product of length and width (LW) were found for ordinary leaves with lanceolate, oblanceolate, linear and sagitttate shapes with entire margins, serrate margins, mixed margins with a entire form and shallow lobes, and ordinary incised margins. LA was better correlated with LW than L or W, with $R^2$ > 0.91. However, for deeply incised lobes, LA estimation using LW showed low correlation coefficient values, indicating low accuracy. On the other hand, a method using photographic paper showed a good correlation between estimates of area based on the mass of a cut-out leaf image on a photographic sheet (PW) and actual leaf area for all types of leaf shape. Thus, the PW method for LA estimation can be applied to all shapes of leaf with high accuracy. The PW method takes a little more time and has a higher cost than leaf estimation methods using LW based on leaf dimensions. These results indicate that researchers should choose their nondestructive LA estimation method according to their research goals.

AN IN VITRO STUDY ON MARGINAL LEAKAGE PREVENTION WITH AN ADHESIVE SEALANT (NUVA-SEAL) (변연누출방지(邊緣漏出防止)를 위한 전색재(塡塞材)[NUVA-SEAL]의 이용(利用)에 관(關)한 실험적(實驗的) 고찰(考察))

  • Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.3 no.1
    • /
    • pp.33-39
    • /
    • 1976
  • The present in vitro study was undertaken to evaluate the initial marginal sealing ability of the sealant known as Nuva-Seal to seal cavity margins when used in conjunction with Adaptic and Nuva-Fil restorative materials. The results were as follows; 1. Where each Adaptic and Nuva-Fil restorative material was filled, showed the greatest degree of marginal leakage. 2. Where Adaptic and Nuva-Fil restorative materials were filled after acid etched surrrounding enamel surface adjoining the cavity margins, showed some degree of marginal leakage. 3. Where the Nuva-Seal was applied after acid etching a) to the cavity walls and the peripheral enamel surface adjoining the cavity margins, b) only to the surrounding enamel surface adjoining the cavity margins, and c) over the restorations and the peripheral enamel surface, showed complete absence of marginal leakage of Adaptic and Nuva-Fil restorative materials. 4. Where the Nuva-Seal was applied with the same methods as above, and restorations were placed on thermal stress also showed complete absence of marginal leakage of Adaptic and Nuva-Fil restorative materials.

  • PDF

ON THE MARGINAL FIDELITY OF ALL-CERAMIC CORE USING CAD/CAM SYSTEM (CAD/CAM을 이용하여 제작한 All-ceramic core의 변연 적합도)

  • Kim Dong-Keun;Cho In-Ho;Lim Ju-Hwan;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.20-34
    • /
    • 2003
  • Novel methods producing supplementary and prosthetic material by cutting or discharge processing via computer design have been proposed as alternatives for traditional casting methods and are being utilized for commercial purposes. The CAD/CAM system used in dentistry can be classified into three-dimensional input of target values, restoration design, and material processing. The marginal fidelity in production of In-Ceram core has important clinical implications and is a key consideration issue in CAD/CAM production as well. Through this research, the author arrived at the following conclusion aaer conducting comparison analysis of marginal fidelities between the In-Ceram core produced via CAD/CAM and that produced through the traditional method ; 1. In the cases of mesial, distal, and lingual margins, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 2. In the case of labial flange, the core margins via CAD/CAM produced lower values than those via the traditional method and the differences were found to be statistically significant. (p<0.05) 3. In comparision with overall marginal fidelity, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 4. Among the core margins produced via the traditional method did not have statistically significant differences but fir those produced via CAD/CAM had statistically significant differences between labial and lingual sides and between labial and mesial sides. (p <0.05).

AN EXPERIMENTAL STUDY FOR THE EFFECT OF ALL-BOND 2, GLUMA, SCOTCH BOND MULTI-PURPOSE (수종 상아질 접착제의 제 V급 와동에서의 미세 변연누출에 관한 비교연구)

  • Kang, Chang-Seong;Park, Seong-Ho;Lee, Chong-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.261-274
    • /
    • 1995
  • This study aimed to evaluate the marginal microleakage of Class V cavities of All-bond 2 (Wet - bonding system), Gluma (Adhesion of resin to exposed collagen fibers), and Scotchbond Multi-purpose(Mild Etching System). Hundred extracted human teeth divided into a control and three experimental groups consisting of eight teeth. The experimental group was further subdivided into All- bond2, Gluma and Scotchbond MP groups, Vitrebond served as the control. The positive control group consisted of specimens filled with resin and with no etching, primer and bonding procesure. Polished specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ a thousand times. After thermocycling, speciemens were placed in 2 % methylene blue dye solution for 24 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a stereomicroscoped(*20). The following results were obtained. 1. Both the control and the experimental group showed a lower degree of dye penetration on enamel than on dentin margins(p<0.05) 2. Gluma exhibited a statistically significant lower degree of dye penetration than All-bond 2 on enamel margins(p<0.05) Scotchbond MP also exhibited a lower degree of dye penetration than All-bone 2 but was no statistically significant. Gluma and Scotchbond MP exhibited a similar degree of dye penetration. 3. The degree of dye penetration of All-bond 2, Gluma and Scotch bond MP showed no statistically singnificance on enamel margins but was significantly lower than in the control using Vitrebond. 4. All-bond 2 exhibited a statistically significant lower degree of dye penetration than Gluma on dentin margins. All- bond 2 and Scotchbond MP showed a similar degree of dye penetration. 5. The degree of dye penetration of All-bond 2, Gluma and Scotchbond MP showed no statistically significance on dentin margins. There was neither a statistical significance with the control.

  • PDF

Diversification, Industry Concentration, and Bank Margins: Empirical Evidence from an Emerging South Asian Economy

  • SARWAR, Bilal;MUHAMMAD, Noor;ZAMAN, Nadeem Uz
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.7
    • /
    • pp.349-360
    • /
    • 2020
  • The study aims to empirically examine the determinants of bank margins from Pakistan, an emerging South Asian economy. To elucidate the importance of the Pakistani banking sector, secondary data has been used, which was extracted from the annual accounts of twenty-four Pakistani scheduled commercial banks (20 conventional, four full-fledged Islamic) over a sample period of 2006 to 2017. The factors identified in the dealership model and the subsequent empirical developments in the dealership model categorized as bank-specific, diversification, regulatory, and industry concentration are analyzed by applying the most-common linear dynamic panel-data estimator, the Generalized Method of Moments (GMM) estimator, developed by Arellano and Bond (1991). The findings reveal that, among the bank-specific variables, funding cost, credit risk, managerial efficiency, market share, and operating cost are significant predictors of bank margins. For diversification variables employed in the study, both variables including net non-interest income and asset diversity are as well significant predictors of bank margins. It is also found that the market concentration variable proxied by the Herfindahl-Hirschman Index (HHI) is significantly predicting bank margins. Subsequently, one of the regulatory variables, the opportunity cost of holding reserves, and one bank-specific variable, the degree of risk aversion, are insignificant in the model.

MARGINAL ADAPTATION OF COMPOSITE RESIN USING GLASS IONOMER CEMENT BASES (Glass ionomer cement를 이장한 Composite resin의 변연 적합성에 관한 연구)

  • Han, Seung-Weon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.5-19
    • /
    • 1989
  • The purpose of this study was to observe the microleakage of composite resin filling using several glass ionomer cements. The Class V cavities of eighty noncarious human molars were prepared at the cementoenamel juction on the facial and lingual surfaces of each tooth with a No.330 carbide bur in a high speed handpiece. The cavity dimensions were $3.0{\pm}0.5mm$ wide, $2.0{\pm}0.5mm$ high, and $1.5{\pm}0.5mm$ deep and all enamel cavosurface margins were beveled with a No.558 carbide bur in low speed handpiece. The bevel was approximately $45^{\circ}$ and 0.5-1.0mm in width. A total of the 160 cavities was divided into four groups, and then 144 cavities among them were three experimental groups and remaining sixteen cavities were control group. All of the prepared cavities were restored as follows: group 1 : Preparations were restored with there three glass ionomer cements. group 2 : Preparations were restored with a composite resin with three glass ionomer cement bases placed $0.2{\pm}0.1mm$ short of the cavosurface margin. group 3 : Preparations were restored with a composite resin with three glass ionomer cement bases extened to the cavosurface margin. group 4 : As control group, preparations were restored with a composite resin, PALFIQUE. The specimens were then thermocycled in a range of $6^{\circ}C-60^{\circ}C$ and immersed in a bath of 2.0% aqueous basic fuchsin solution for 24 hours. Dye penetration was read on a scale of 0 to 4 by Tani and Buonocore's method. The following conclusions were derived from the results obtained; 1. All groups showed significantly more leakage at the gingival margins than at the occlusal margins(p<0.0005). 2. At the gingival margins, group 1 showed less leakage than group 3(p<0.01) and group 4(p<0.0005), while group 3 exhibited less leakage than group 2(p<0.01) and group 4(p<0.0005). 3. At the occlusal margins, group 4 showed less leakage than group 3(p<0.1) and group 1(p<0.005), while group 3 exhibited less leakage than group 2(p>0.1) and group 1(p<0.025).

  • PDF