• 제목/요약/키워드: Marginal configuration

검색결과 15건 처리시간 0.028초

경사진 상부 형태(sloped marginal configuration)를 가진 임플란트의 특징과 임상적 의미 (Characteristics and clinical meanings of the implant with a sloped marginal configuration)

  • 김태형
    • 대한치과의사협회지
    • /
    • 제54권5호
    • /
    • pp.328-341
    • /
    • 2016
  • An overall reduction in the horizontal and vertical dimensions occurs following tooth extraction and the resorption of the buccal part of the ridge is more pronounced than the lingual part. Thus, the resulting morphology of the healed alveolar ridge is often presenting with a discrepancy in bone height between the buccal and lingual aspects of the ridge. The implant with a sloped marginal configuration that is designed to match the sloped contour of the alveolar ridge provides the opportunity to maintain the buccal-lingual bone discrepancy and soft tissue around the implant. This paper introduces the OsseoSpeed TX Profile implants with sloped marginal configuration and explains the characteristics and clinical meanings of those implants.

  • PDF

와동형태가 5급 와동 수복물의 변연누출에 미치는 영향 (THE EFFECT OF CAVITY CONFIGURATION ON MARGINAL LEAKAGE OF CLASS 5 RESTORATION)

  • 박정길;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.162-170
    • /
    • 2001
  • The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).

  • PDF

Semiflexible Polymer Brushes: Most Probable Configuration Approach Based on Cotinuous Chain Model

  • 김광규;차국헌
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권9호
    • /
    • pp.1026-1030
    • /
    • 1999
  • The properties of semiflexible polymer brushes are studied by applying the classical limit of mean-field approach for chains with marginal chain stiffness. Using the mean-spherical Gaussian model, the most probable configuration for semiflexible chains is obtained, which reduces to the parabolic brush of Milner et al. [Mac-romolecules 1988, 21, 2610] in the flexible limit. From this configuration, equilibrium brush height as well as interactions between semiflexible brushes are estimated.

Collarless도재소부전장금관의 제작방법에 따른 치경부 변연적합도에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE CERVICAL MARGIN FITNESS IN THE COLLARLESS METAL CERAMIC CROWNS FORMED BY DIFFERENT TECHNIQUES)

  • 이재혁
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.203-216
    • /
    • 1990
  • The purpose of this study was to evaluate the cervical margin fitness in the collarless metal ceramic crowns formed by different techniques. Specimens were divided as follows : the metal ceramic crowns with metal butt margin as group I, the collarless metal ceramic crowns formed with resin binder technique as group II, and the collarless metal ceramic crowns formed with shoulder powder mixed with phosphate-bonded investment liquids on a refractory die as group III. Each group was made of five specimens, and their marginal fitness on each epoxy die was evaluated under scanning electron microscope of x200 magnification at three measuring points : mesial, central, distal. The following results were obtained. 1. The metal ceramic crowns with metal butt margin exhibited significantly better marginal fitness than the collarless metal ceramic crowns. The marginal fitness in descending order was group I, III, II. 2. The collarless metal ceramic crown formed with resin binder technique had the worst marginal fitness & showed cervical color variation and dermacation between the corrected porcelain & the dentin porcelain. 3. The collarless metal ceramic crowns formed with shoulder powder mixed with phosphate-bonded investment liquids on a refractory die exhibited significantly better marginal fitness & sharper marginal configuration than the other collarless group.

  • PDF

Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown

  • Ji, Min-Kyung;Park, Ji-Hee;Park, Sang-Won;Yun, Kwi-Dug;Oh, Gye-Jeong;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.271-277
    • /
    • 2015
  • PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau$^{(R)}$Zirconia and ZENOSTAR$^{(R)}$ZR translucent) and lithium disilicate glass ceramic (IPS e.max$^{(R)}$press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max$^{(R)}$press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR$^{(R)}$ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) had overextended margins.

주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구 (THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS)

  • 오수연;방몽숙;양홍서;박상원;박하옥
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

완전 도재관을 위한 지대치 형성시 변연 형태에 따른 응력 분포의 유한요소법적 비교 (FEA estimates of margin design in all ceramic crowns)

  • 한상현;조정현;이은정;정숙인;오남식
    • 대한치과보철학회지
    • /
    • 제46권1호
    • /
    • pp.1-11
    • /
    • 2008
  • 현대 치의학에서는 환자의 심미적 만족을 충족시키기 위한 지속적인 관심으로 완전 도재관의 발전을 가져왔다. 최근의 연구 결과들은 완전 도재관의 물리적 성질과 마모 저항성, 색조의 안정성 등을 보고하고 있다. 이와 같이 여러 장점이 많음에도 불구하고 아직 파절에 대한 저항성에는 많은 의문점을 내포하고 있다. 구강 내에서 기능적인 교합력은 수복물의 변연에 응력을 주게된다. 이러한 응력은 주변 조직으로 잘 분산되어져야 하는데, 수복물의 변연 형태에 따라 다른 양상을 보여주게 된다. 변연 형태는 수복물의 부피와 모양, 그리고 변연에서의 적합도에도 영향을 주게 된다. 본 연구에서는 완전 도재관에서의 변연 형태에 따른 응력 분포를 3차원 유한 요소 분석법을 이용하여 조사하였다. 상악 중절치가 기본 모델로 사용되었고, 완전 도재관을 재현하였다. 변연 형태로는 $90^{\circ}$ shoulder, $110^{\circ}$ shoulder, $135^{\circ}$ shoulder형태를 부여하고, 100N의 힘을 치축에 $45^{\circ}$ 방향으로 가하였다. 그 결과 도재 내부의 응력 분포는 $90^{\circ}$, $110^{\circ}$ 모델에 비해 변연 각도가 $135^{\circ}$인 모델의 경우가 응력의 분포가 고르게 나타났다. 그러나 변연에서는 $90^{\circ}$$110^{\circ}$ 모델의 응력보다 조금 더 집중되었다. $90^{\circ}$$110^{\circ}$ 모델의 비교시는 대체로 비슷했다. 알루미나 코아 내부의 응력 분포에서도 또한 $135^{\circ}$인 모델이 $90^{\circ}$$110^{\circ}$ 모델의 응력분포보다 더 잘 분포되었다. $90^{\circ}$$110^{\circ}$ 모델의 비교시는 $110^{\circ}$$90^{\circ}$ 모델에 비해 더 좋은 응력분포를 보였다. 알루미나 코아와 접착제 사이의 계면에서는 응력이 변연으로 갈수록 감소하고, 알루미나 코아와 도재 사이의 계면에서는 변연으로 갈수록 응력이 점차 증가하였다. $135^{\circ}$ shoulder는 고른 응력분포임에도 변연에서의 응력 집중이 나타나므로 완전 도재관의 변연으로는 적절하지 못하며, $90^{\circ}$ shoulder보다 상대적으로 좋은 응력분포와 변연 형성의 용이성이 우세한 $110^{\circ}$ shoulder가 완전 도재관의 변연에 추천될 수 있겠다.

두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study) (Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study)

  • 이지은;허성주;곽재영;김성균;한종현
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.169-174
    • /
    • 2008
  • 목적: 치과 임플랜트 주위의 변연골 변화는 임플랜트의 기능적인 유지 뿐만 아니라 심미적 성공을 위해서도 중요하다. 변연골의 유지를 위한 임플랜트 디자인이 연구되고 있다. 이번 예비 연구는 두 종류의 external hex implant 시스템에서 임플랜트의 상부 미세 나사산이 변연골 변화량에 미치는 영향을 평가하고자 한다. 재료 및 방법: 총 24명의 환자를 대상으로 $Br{{\aa}}nemark$ 임플랜트 식립군 (1군, 거친 표면 임플랜트, 20개)과 원플란트 임플랜트 식립군 (2군, 미세나사산을 가진 거친 표면 임플랜트, 20개)으로 분류하였다. 기준 시점 (임플랜트 부하)과 부하를 가한 1년 뒤 임상적, 방사선학적 검사를 시행하였다. UTHSCSA Image Tool을 이용하여 임플랜트-보철 경계부로부터 변연골 높이 변화량으로 계측하였다. 계측치는 SAS 프로그램을 이용하여 three-level ANCOVA로 통계처리 하였다. 결과: 기준 시점과 비교하여 1년 기능 후, 두 그룹 간의 변연골 소실 변화량에 있어서 통계학적으로 유의한 차이가 있었다 (P<0.05). 1군의 평균 변연골 높이 변화량은 $0.83{\pm}0.31mm$, 2군에 있어서는 $0.44{\pm}0.36mm$ 이었다. 미세나사산을 가진 거친 표면 임플랜트가 미세나 사산을 가지지 않은 거친 표면 임플랜트 보다 더 적은 변연골 소실 변화량을 보였다. 결론: 미세나사산을 가진 거친 표면 임플랜트가 기능적 부하 후 변연골 높이를 유지하는데 있어 더 유리한 디자인으로 보인다.

Non linear soil structure interaction of space frame-pile foundation-soil system

  • Chore, H.S.;Ingle, R.K.;Sawant, V.A.
    • Structural Engineering and Mechanics
    • /
    • 제49권1호
    • /
    • pp.95-110
    • /
    • 2014
  • The study deals with physical modeling of space frame-pile foundation and soil system using finite element models. The superstructure frame is analyzed using complete three-dimensional finite element method where the component of the frame such as slab, beam and columns are descretized using 20 node isoparametric continuum elements. Initially, the frame is analyzed assuming the fixed column bases. Later the pile foundation is worked out separately wherein the simplified models of finite elements such as beam and plate element are used for pile and pile cap, respectively. The non-linear behaviour of soil mass is incorporated by idealizing the soil as non-linear springs using p-y curve along the lines similar to that by Georgiadis et al. (1992). For analysis of pile foundation, the non-linearity of soil via p-y curve approach is incorporated using the incremental approach. The interaction analysis is conducted for the parametric study. The non-linearity of soil is further incorporated using iterative approach, i.e., secant modulus approach, in the interaction analysis. The effect the various parameters of the pile foundation such as spacing in a group and configuration of the pile group is evaluated on the response of superstructure owing to non-linearity of the soil. The response included the displacement at the top of the frame and bending moment in columns. The non-linearity of soil increases the top displacement in the range of 7.8%-16.7%. However, its effect is found very marginal on the absolute maximum moment in columns. The hogging moment decreases by 0.005% while sagging moment increases by 0.02%.

최단경로 라우팅을 이용한 효율적인 인터넷 트래픽 엔지니어링 (Efficient Internet Traffic Engineering based on Shortest Path Routing)

  • 이영석
    • 한국통신학회논문지
    • /
    • 제29권2B호
    • /
    • pp.183-191
    • /
    • 2004
  • 단일 최단경로 라우팅 알고리즘은 흔히 최대 링크 로드를 최소화하는 인터넷 트래픽 엔지니어링에 적합하지 않다고 알려져있다. 또한 여러 개의 최단경로들을 동시에 사용하여 트래픽을 나누어서 전송하는 방법은 전체 트래픽 디맨드를 고려하지 않기 때문에 최대링크로드를 반드시 최소화시키지는 못한다. 하지만, 여러 개의 최단경로들이 동일 송수신 노드 사이에 존재하면, 기존 라우팅 프로토콜에 변화를 주지 않고도 최대 링크 로드를 최소화시킬 수 있는 최단경로들의 집합을 선택하여 이용할 수 있다. 이러한 최단 경로들을 계산할 때에는 동일 목적지에 대해서는 송신자에 관계없이 동일한 넥스트-홉을 유지해야한다. 본 논문에서는 트래픽 엔지니어링을 위한 최단 경로 라우팅 알고리즘의 최적해를 구할 수 있는 ILP 문제를 제시하고, 근사해를 구하기 위한 휴리스틱 알고리즘을 제안하고 성능을 평가하였다.