• 제목/요약/키워드: Marginal Fitness

검색결과 56건 처리시간 0.024초

도재용 금합금 재사용에 따른 변연 적합도에 관한 연구 (A study on the marginal fitness to reuse with a Au-Pt-Pd alloy for porcelain fused to metal crown)

  • 문희경
    • 대한치과기공학회지
    • /
    • 제32권1호
    • /
    • pp.17-21
    • /
    • 2010
  • This experimental study was to determine the fitness in each cervical margin of reusing porcelain gold alloy. The gold alloy used in this experimental study was a Au-Pt-Pd alloy (BDCG-898, Bukwang Inc, Korea) for the fabrication of porcelain fused to metal crown. Twenty-five copings were divided into the five groups. And the group A, B, C, D and E were cording successively according to the frequency of reuse to five times. Each specimen was reused without adding new metal. The experimental results were as follows: 1. The group A, B, C showed good fitness in each cervical margin. 2. The group D got good fitness in labio and linguo cervical margin, but the mesio and disto cervical margin showed more than $40{\mu}m$ 3. The group E showed worse fitness than the other groups in each cervical margin.

치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가 (An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system)

  • 한만소
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

수종의 CAD/CAM 시스템으로 제작한 지르코니아 코어에서 Replica Technique을 이용한 변연 및 내면 적합도 평가 (Evaluation using Replica Technique on the marginal and internal fitness of zirconia cores by several CAD/CAM systems)

  • 허중보;박청길;김하영;박찬경;신상완
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.135-142
    • /
    • 2010
  • 연구목적: 최근CAD/CAM으로 제작한 지르코니아 코어의 변연적합도에 관한 연구가 많이 진행되었지만, 여러 종의CAD/CAM 시스템의 변연 뿐만 아니라 내면적합도까지 상호 비교한 연구는 아직 미흡한 실정이다. 따라서 본 연구에서는 3종의CAD/CAM 시스템으로 제작한 전치부 단일 치아 지르코니아 코어의 변연 및 내면적합도를 Replica technique을 이용해 평가하고자 하였다. 연구 재료 및 방법:3종의CAD/CAM 시스템 (Cerasys $system^{(R)}$, KaVo $Everest^{(R)}$, $LAVA^{TM}$)을 이용하여, 시스템 별로 5개씩의 단일치아 지르코니아 코어를 제작하였다. 제작된 지르코니아 코어를 레플리카 테크닉 (Replica Technique)을 이용해 복제하고 복제된 시편을 협설, 근원심으로 정중앙을 절단하여 변연 및 내면의 간격을 측정하였다. Measuring microscope ($AXIO^{(R)}$)를 이용하여 50배 확대하여 촬영하고 $I-Solution^{(R)}$을 이용하여 측정하였고, ANOVA를 이용하여 통계적으로 분석하였다. 결과:지르코니아코어의 평균 변연간격은 $Cerasys^{(R)}$$84.74{\pm}27.57{\mu}m$, KaVo $Everest^{(R)}$$80.23{\pm}21.07{\mu}m$, $Lava^{TM}$$96.37{\pm}11.45{\mu}m$이었고 평균내면간격은각각 $Cerasys^{(R)}$$94.99{\pm}18.74{\mu}m$, KaVo $Everest^{(R)}$$92.31{\pm}25.18{\mu}m$, $LAVA^{TM}$$94.99{\pm}18.74{\mu}m$이었으며, 세 시스템간의 변연 및 내면간격의 평균적인 적합도에서 통계적 유의차는 없었다. 변연 및 내면간격의 비교에서는 KaVo $Everest^{(R)}$$LAVA^{TM}$보다 전반적으로 내면간격이 작은 것으로 보였다 (P< .05). 내면간격 중 절단부위의 간격은 세 시스템에서 공통적으로 다른 부위보다 크게 나타났다. 결론:본 연구에서 $Cerasys^{(R)}$, KaVo $Everest^{(R)}$, $LAVA^{TM}$시스템의 변연적합도는 차이가 없었고, 내면적합도는 KaVo $Everest^{(R)}$$LAVA^{TM}$ 보다 적었으나 세 시스템에서 공통적으로 절단부위 간격이 크게 나타났다. 세 시스템 모두 변연적합도 및 내면적합도가 임상적으로 허용범위 내에 있었다.

광간섭단층영상기를 이용한 치과용 지르코니아 코어의 적합도 분석 (Analysis of the Marginal and Internal Fit of Dental Zirconia Core Using Optical Coherence Tomography(OCT))

  • 김재홍;김기백
    • 한국콘텐츠학회논문지
    • /
    • 제12권8호
    • /
    • pp.240-247
    • /
    • 2012
  • 보철물이 구강 내 제 기능을 하기 위해 가장 중요한 요소 중 하나는 적합도이다. 본 연구의 목적은 그 동안 시도되지 않았던 광간섭단층영상기를 이용하여 비파괴적인 방법으로 적합도를 측정해보고, 측정된 값을 기존의 방법으로 측정된 값과 비교하여 보고자 한다. 실험을 위해 상악 우측 중절치가 지대치인 석고모형 10개를 제작하고 치과용 캐드캠으로 각각의 모형에 해당하는 지르코니아 코어를 10개 제작하였다. 시편 당 5부위 씩 광간섭단층영상기로 적합도를 측정하고, 같은 부위를 기존의 방법인 실리 복제본 기술로 측정하였다. 두 집단 간의 평균 값에 유의한 차이가 있는지 알아보기 위해 독립표본 t-검정을 실시하였다(${\alpha}$=0.05). 그 결과 측정된 두 집단 간의 평균 값에는 유의한 차이를 보이지 않았고(P>0.05), 이러한 결과로 미루어 볼 때 앞으로 광간섭단층영상기를 이용한 보철물의 적합도 측정이 가능할 것으로 사료된다.

CAD/CAM으로 제작한 코누스내관의 변연적합 (MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM)

  • 김인섭;강동완
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.30-41
    • /
    • 2002
  • This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{\mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{\pm}43{\mu}m$, 28.9% of the specimen showed marginal gap over $100{\mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).

코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가 (Evaluation of fitness of metal-ceramic crown fabricated by cobalt-chrome alloy)

  • 김재홍;김원수;김기백
    • 한국치위생학회지
    • /
    • 제13권2호
    • /
    • pp.361-368
    • /
    • 2013
  • Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${\alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${\mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${\mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.

단일구조 지르코니아 크라운의 소결 후 추가 소성 과정이 변연 및 내면 적합도에 미치는 영향 (Effect of additional firing process after sintering of monolithic zirconia crown on marginal and internal fitness)

  • 신미선;이현종
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.321-327
    • /
    • 2019
  • 목적: 본 연구는 단일구조 지르코니아 크라운의 소결 후 소성 과정이 변연 및 내면 적합도에 미치는 영향에 대하여 3차원으로 평가해 보고자 하였다. 재료 및 방법: 타이타늄 지대치 모형을 제작하여 10개의 단일구조 지르코니아 크라운을 제작하였다. 제작된 단일구조 지르코니아 크라운을 소결 한 상태를 대조군으로, 소결 후 광택을 위해 추가적인 소성단계를 거친 후를 실험군으로 설정하였다. 각 군에서 triple-scan protocol을 이용하여 협설과 근원심으로 단면을 형성하고 변연 및 내면 적합도를 계측하여 통계 분석하였으며, 삼차원 표면 비교를 시행하였다 (${\alpha}=.05$). 결과: 변연과 내면 적합도를 분석한 결과 근심 축벽에서 대조군($32.0{\pm}24.3{\mu}m$)과 실험군 간($17.0{\pm}10.8{\mu}m$)의 통계적 유의한 차이가 있었고 (P < .020), 원심 축벽에서 대조군($60.2{\pm}24.3{\mu}m$)과 실험군($71.8{\pm}21.5{\mu}m$)간의 통계적으로 유의한 차이가 있었다 (P < .01). 나머지 측점지점에서는 통계적으로 유의한 차이가 없었다. 결론: 단일구조 지르코니아 크라운에서의 소결 후 추가적인 소성은 내면의 변형에 큰 영향을 미치지 않았고 임상적으로 허용 가능한 범위에 있었다.

치과보철물 제작에 사용되는 금속-도재용 합금, IPS - Empress, 지르코니아($ZrO_2$) 세라믹의 변연적합도에 관한 비교평가 (The comparative study on the marginal fit of a metal-ceramic alloy, IPS - Empress and a zirconia($ZrO_2$) ceramic used for fabrication of dental restoration)

  • 김철수
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.7-14
    • /
    • 2011
  • Purpose: As the demand and importance of aesthetic aspects in dental treatment become higher, much attention is paid to materials used for dental prostheses. Thus, the marginal fidelity of most-commonly used alloy, IPS - Empress and ZrO2 ceramic is compared. Methods: The alloy core made by casting, IPS - Empress core made by pressing and ZrO2 ceramic core made by CAD/CAM are used to make 10 samples respectively. For each core, three points were measures and the optical microscope (Axio Imager.Alm,Zeiss co., Oberkochen, Germany) was used to observe the cores with a magnification of 100. Results: As for alloy, IPS - Empress and ZrO2 ceramic, the average and deviation of their marginal distance are $29.91\;{\pm}11.93{\mu}m$ for alloy, $33.45\;{\pm}8.61{\mu}m$ for IPS - Empress, and $31.55\;{\pm}9.85{\mu}m$ for ZrO2. The one-way ANOVA test was conducted to compare them. However, there was no statistically significant difference among them. Conclusion: The study on marginal fidelity of alloy, IPS - Empress, and ZrO2 ceramic shows they have no marginal fidelity problem clinically. Therefore, if a system is selected based on the patient's condition or treatment method, there will be no problem.