• Title/Summary/Keyword: Marginal Effect

Search Result 531, Processing Time 0.021 seconds

The Effect of Social Exclusion of Marginal Workers on Mental Health (비정규직 근로자의 사회적 배제가 정신건강에 미치는 영향 - 건설직 일용근로자의 우울을 중심으로 -)

  • Rho, Byeong-Il;Son, Jung-Hwan
    • Korean Journal of Social Welfare
    • /
    • v.63 no.1
    • /
    • pp.113-135
    • /
    • 2011
  • As intense economic competition has led to more flexibility in the labor market, marginal or atypical employment has rapidly grown. Although marginal work represents an important proportion of whole employment, it is still characterized by insecure and unfavorable working conditions. Therefore employees in marginal jobs are highly likely to be subject to social exclusion. In turn, social exclusion puts marginal workers in a high risk of mental health problems. One of major mental health symptoms has been depression. So far, however, little attention has been paid to the effect of social exclusion of marginal employees on mental health problems including depression. Hence this study examines empirically the effect of social exclusion of casual workers in the construction industry, a protype of marginal employees, on depression. Its results indicate that social exclusion has influence upon depression of marginal workers. This study is the first one to delve into the relationships between temporary employment, social exclusion, and depression of marginal employees. Yet much more empirical researches are needed in order to shed brighter light on these relationships.

  • PDF

Effect of cement space on the marginal and internal fit of zirconia restorations fabricated by CAD/CAM system (시멘트 공간이 캐드캠 시스템으로 제작한 지르코니아 수복물의 변연과 내부 적합도에 미치는 효과)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.39 no.4
    • /
    • pp.235-242
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of zirconia copings fabricated by CAD/CAM system and to research the effect of cement space on the fit of zirconia prosthesis. Methods: Zirconia copings were designed using 3shape software and then milled from presintered zirconia blocks by Kavo dental milling machine. The cement space was set at $0{\mu}m$ around the margins for all groups, and additional cement space appling 1 mm above the finish lines of tooth. The samples were classified into 4 groups according to the cement space setting(Cs-0, Cs-40, Cs-80, Cs-120). Replica technique used to investigate marginal and internal gap. The silicone film thickness was recorded using a optical microscope with image software analysis system at 75${\times}$magnification. The assessment performed on the six points in bucco-lingual and mesio-distal sections(4 groups, 10 copings per group, 12 measuring points per coping). The data were statistically analyzed with one-way ANOVA followed by pair-wise Tukey's post hoc tests(${\alpha}$<0.05). Results: Better marginal and internal fit values were exhibited by $80{\mu}m$ cement space. The results showed that different cement space values had statistically significant effect on the marginal and internal gap of zirconia copings(p<0.001). The gap of margin and axial wall area was smaller than that the gap of occlusal area in all groups(p<0.001). Conclusion : Effect of different cement spaces on the marginal and internal gap of zirconia copings.

The Effect of Abutment Inclined Angle on the Marginal Fit of Zirconia All-ceramic Crown (지대주 경사각이 지르코니아 전부도재관의 변연적합도에 미치는 영향)

  • Lee, Seo-Yeon;Chung, In-Sung;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.111-117
    • /
    • 2016
  • Purpose: The present study was performed to investigate the effect of abutment inclined angle on the marginal fit of zirconia all-ceramic crown. Methods: The Ti abutments with 3 different inclined angle($2^{\circ}$, $4^{\circ}$ and $6^{\circ}$) were fabricated. The zirconia copings were fabricated for each abutment by using dental CAD/CAM system. The manufactured zirconia copings were duplicated through silicone replica technique, and a replicated specimen was sectioned in the center of bucco-lingual and mesio-distal axial to measure the marginal fit by using a stereo microscope. The results were analyzed using a one-way ANOVA with SPSS 22.0 for Windows(${\alpha}=0.05$). Results: On the bucco-lingual axial, marginal fit was the RL3($41.5{\pm}3.4{\mu}m$), RL2($44.3{\pm}4.3{\mu}m$) and RL1($47.5{\pm}5.7{\mu}m$), respectively. On the mesio-distal axial, marginal fit was the RL3($41.1{\pm}3.7{\mu}m$), RL2($45.7{\pm}5.3{\mu}m$) and RL1($46.2{\pm}4.5{\mu}m$), respectively. One-way ANOVA showed statistically significant difference between groups for marginal fit(p<0.05). Conclusion: For marginal fit of the abutments inclined angle, RL3 specimen was superior. The abutment inclined angle had influence on marginal fit of the zirconia copings. The marginal fit of each group were within clinically acceptable range.

Study on The Influence of Road Capital to Industry and Productivity Growth in South Korea (한국 도로 자본이 산업에 미친 영향과 생산성 분석)

  • Kook, Woo Kag
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.169-181
    • /
    • 2013
  • PURPOSES : This study is to suggest the Influence of road capital to industry and productivity growth in South Korea. METHODS : Based on the literature review, The relevant policy questions addressed in this report are : cost reduction and Scale elasticities of road, effect of road capital stock on demand for labor, capital and materials, marginal effect of road, industry TFP growth decomposition. RESULTS : The marginal benefits of the road capital at the industry level were calculated using the estimated cost elasticities. Demand for the road capital services varies across industries as do the marginal effects. The marginal benefits are positive for the principal industries. This suggests that for these industries the existing stock of road capital may be under supplied. The contribution of road capital to TFP growth is positive in principal industries. The main contribution of road capital is in the manufacturing industries ; the magnitudes of contribution varies among industries. These results indicate that growth in exogenous demand is most important contributor to TFP growth. CONCLUSIONS : The road capital have a significant effect on employment, private capital and demand for materials inputs in all industries. At a given level of output, an increase in road capital lead to variety to demand for all inputs in all industries.

Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using stereomicroscopy as gold standard

  • Rastogi, Abhishek;Kamble, Vikas
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.69-75
    • /
    • 2011
  • This study assessed the effect of preparation design on marginal adaptation and also compared the sensitivity and specificity of clinical evaluation techniques for marginal accuracy of cast restorations to stereomicroscopy. MATERIALS AND METHODS. Three Ivorine molar teeth of different designs were prepared. (A)-A complete crown preparation with buccal shoulder and beveled finish line. (B)-A complete crown preparation with chamfer finish line. (C)-A three-quarter crown preparation with proximal boxes and beveled finish line. Twenty four castings were prepared with eight castings for each design respectively. Each casting underwent examination with an explorer, disclosing media, and a stereomicroscope. Stereomicroscopy at a value less than or equal to 30 microns was used as a gold standard to evaluate the significance of different designs on marginal adaptation. Chi-square tests of independence and Kruskal-Wallis were used to evaluate the effect of preparation design and compare the agreement between examination methods for detection of marginal gap size of greater than or equal to 30 microns (${\alpha}$=.05). Sensitivity and specificity for explorer and disclosing media as compared to stereomicroscope was calculated using statistical formula given by Park. RESULTS. The preparation design did not significantly affect overall marginal adaptation. Examination by explorer and disclosing media at $30 \;{mu}m$ revealed 39% and 10.06% sensitivity and 91% and 82% specificity respectively. CONCLUSION. Preparation designs examined in this study did not significantly affect the marginal adaptation of the castings. Commonly used clinical evaluation techniques using explorer and disclosing media appeared to be inadequate for assessment of marginal accuracy.

How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materials

  • Hasanzade, Mahya;Moharrami, Mohammad;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.344-350
    • /
    • 2020
  • PURPOSE. Recently introduced hybrid and reinforced glass ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials have been used for full-coverage restorations. However; the effect of adjustment and type of materials on internal and marginal adaptation are unknown. This study aimed to evaluate and compare the marginal and internal adaptations of crowns made of three different CAD/CAM materials before and after adjustment. MATERIALS AND METHODS. One acrylic resin maxillary first molar was prepared and served as the master die. Thirty-six restorations were fabricated using CAD/CAM system (CEREC Omnicam, MCXL) with three materials including lithium disilicate (IPS e.max CAD), zirconia-reinforced lithium silicate (Suprinity), and hybrid ceramic (Enamic). Internal and marginal adaptations were evaluated with the reference point matching technique before and after adjustment. The data were analyzed using mixed ANOVA considering α=.05 as the significance level. RESULTS. The effect of adjustment and its interaction with the restoration material were significant for marginal, absolute marginal, and occlusal discrepancies (P<.05). Before adjustment, Suprinity had lower marginal discrepancies than IPS e.max CAD (P=.18) and Enamic (P=.021); though no significant differences existed after adjustment. CONCLUSION. Within the limitations of this study, crowns fabricated from IPS e.max CAD and Suprinity resulted in slightly better adaptation compared with Enamic crowns before adjustment. However, marginal, axial, and occlusal discrepancies were similar among all materials after the adjustment.

The effect of vent on the marginal discrepancy of the PFM base metal castings (Vent의 형성이 도재전장 비귀금속합금 주조체의 변연부 적합도에 미치는 영향)

  • Kim, Tae-Suk;Lee, Sung-Uk;Oh, Sae-Yoon;Kim, Woong-Chul;Kim, Ji-Hwan;Yoo, Jin-Ho
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.45-53
    • /
    • 2001
  • This study was performed to investigate the effect of vent on the marginal discrepancy of PFM base metal castings. Eighteen identical wax patterns of a maxillary 3 unit anterior bridge were fabricated. Nine cases out of them were vented with $\phi$2.5mm sprue wax, for direct comparison as to the marginal discrepancy of the castings with the other non vented 9 ones. The mean value of marginal discrepancies of the vented castings was $85.02{\pm}25.57{\mu}m$, and that of the non vented was $163.21{\pm}69.88{\mu}m$ respectively. Statistical analysis revealed that marginal discrepancy of the vented casting was significantly reduced(p<0.05).

  • PDF

THE EFFECT OF DENTIN BONDING AGENTS ON MARGINAL LEAKAGE FOLLOWING RESTORATION ON THE CERVICAL ABRASION (치경부 마모증 수복시 상아질 접착제가 변연누출에 미치는 영향)

  • Koo, Bon-Wook;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.2
    • /
    • pp.55-63
    • /
    • 1987
  • The purpose of this study is to evaluate the effect of dentin bonding agents on marginal leakage. V-shaped cavities were prepared on the faciocervical area of 140 extracted human teeth. In Groups of twenty cavities, they were restored as follow: Group 1 with enamel bonding resin and Silux, Group 2 Scotchbond and Silux, Group 3 enamel bonding resin and Heliomolar, Group 4 Dentin Adhesit and Heliomolar, Group 5 enamel bonding resin and Durafill, Group 6 Dentin Adhesive and Durafill, Group 7 Chembond. All specimens were thermocycled alternatively at $4^{\circ}C$ and $60^{\circ}C$ of 2% methylene blue dye solution, and sectioned faciolingually with diamond disk under water spray. The sectioned specimens observed with stereo microscope. Following results were obtained: 1. The groups filled with Scotchbond-Silux or Dentin Adhesit-Heliomolar had appeared lesser marginal leakage compared with the groups with enamel bonding resin-Silux or enamel bonding resin-Helimolar. 2. The group filled with Dentin Adhesive-Durafill did not show the reduction of the marginal leakage compared with the group with enamel bonding resin-Durafill. 3. There was significant difference among the four dentin bonding agents. Scotchbond showed the greatest marginal sealing ability, and Dentin Adhesit was the next. The marginal sealing ability of Dentin Adhesive was the worst.

  • PDF

THE EFFECT OF CAVITY CONFIGURATION ON MARGINAL LEAKAGE OF CLASS 5 RESTORATION (와동형태가 5급 와동 수복물의 변연누출에 미치는 영향)

  • Park, Jeong-Kil;Hur, Bock;Lee, Hee-Ju
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.162-170
    • /
    • 2001
  • The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).

  • PDF

A STUDY ON MARGINAL FIDELITY OF CERAMIC METAL COPINGS TREATED BY VARIOUS METHODS (도재용 금속 코핑의 처리 방법에 따른 변연 적합도에 관한 연구)

  • Koo, Bum-Mo;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.265-276
    • /
    • 1997
  • The effect of thermocycling and surface finishing on the marginal fidelity of copings for a metal ceramic crown was examined. Methods for minimizing the loss of marginal fidelity were evaluated. The results were as follows ; 1. Thermocycling of ceramic metal copings resulted in increased marginal gap. 2. The greatest marginal gap occurred during the first thermocycling of the copings. 3. No additional distortion of marginal fidelity occurred when surface finishing and second thermocycling were completed after initial thermocycling. 4. The gap increases according to various treatment methods showed group 1 to be the highest values. 5. There was no significant difference between group 2 and group 3(p>0.05) 6. There was significant difference between group 1 and group 2, 3(p<0.05). 7. There was no significant difference among the measurement sites.

  • PDF