Dosimetric Analysis on the Effect of Target Motion in the Delivery of Conventional IMRT, RapidArc and Tomotherapy

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.164-170
    • /
    • 2017
  • One of the methods to consider the effect of respiratory motion of a tumor target in radiotherapy is to establish a treatment plan with the internal target volume (ITV) created based on an accurate analysis of the target motion displacement. When this method is applied to intensity modulated radiotherapy (IMRT), it is expected to yield a different treatment dose distribution under the motion condition according to the IMRT method. In this study, we prepared ITV-based IMRT plans with conventional IMRT using fixed gantry angle beams, RapidArc using volumetric modulated arc therapy, and tomotherapy using helical therapy. Then, the variation in dose distribution caused by the target motion was analyzed by the dose measurement in the actual motion condition. A delivery quality assurance plan was prepared for the established IMRT plan and the dose distribution in the actual motion condition was measured and analyzed using a two-dimensional diode detector placed on a moving phantom capable of simulating breathing movements. The dose measurement was performed considering only a uniform target shape and motion in the superior-inferior (SI) direction. In this condition, it was confirmed that the error of the dose distribution due to the target motion is minimum in tomotherapy. This is thought to be due to the characteristic of tomotherapy that treats the target sequentially by dividing it into several slices. When the target shape is uniform and the main target motion direction is SI, it is considered that tomotherapy for the ITV-based IMRT method has a characteristic which can reduce the dose difference compared with the plan dose under the target motion condition.

Facial Recognition Algorithm Based on Edge Detection and Discrete Wavelet Transform

  • Chang, Min-Hyuk;Oh, Mi-Suk;Lim, Chun-Hwan;Ahmad, Muhammad-Bilal;Park, Jong-An
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권4호
    • /
    • pp.283-288
    • /
    • 2001
  • In this paper, we proposed a method for extracting facial characteristics of human being in an image. Given a pair of gray level sample images taken with and without human being, the face of human being is segmented from the image. Noise in the input images is removed with the help of Gaussian filters. Edge maps are found of the two input images. The binary edge differential image is obtained from the difference of the two input edge maps. A mask for face detection is made from the process of erosion followed by dilation on the resulting binary edge differential image. This mask is used to extract the human being from the two input image sequences. Features of face are extracted from the segmented image. An effective recognition system using the discrete wave let transform (DWT) is used for recognition. For extracting the facial features, such as eyebrows, eyes, nose and mouth, edge detector is applied on the segmented face image. The area of eye and the center of face are found from horizontal and vertical components of the edge map of the segmented image. other facial features are obtained from edge information of the image. The characteristic vectors are extrated from DWT of the segmented face image. These characteristic vectors are normalized between +1 and -1, and are used as input vectors for the neural network. Simulation results show recognition rate of 100% on the learned system, and about 92% on the test images.

  • PDF

비디오 품질 향상 응용을 위한 오버레이 텍스트 그래픽 영역 검출 (Overlay Text Graphic Region Extraction for Video Quality Enhancement Application)

  • 이상희;박한성;안정일;온영상;조강현
    • 방송공학회논문지
    • /
    • 제18권4호
    • /
    • pp.559-571
    • /
    • 2013
  • 2차원 비디오를 3차원 스테레오 비디오로 변환할 때 기존 비디오에 삽입되어 있는 오버레이 텍스트(overlay text) 그래픽 영역으로 인해 발생하는 문제점을 이 논문에서 제시한다. 이를 해결하기 위한 방법으로 2차원 비디오를 오버레이 텍스트 그래픽 영역만 있는 영상과 오버레이 그래픽 영역이 추출되어 홀(hole)이 있는 영상으로 분리하여 처리하는 시나리오를 제안한다. 그리고 이 시나리오의 첫 번째 단계로 오버레이 텍스트 영역을 검색하고 추출하는 방법에 대해서만 이 논문에서 논한다. 비디오 시퀀스(sequence)가 입력되면 불필요한 연산 과정을 줄이기 위해 해리스 코너(Harris corner)로 얻어진 코너 밀도 맵을 이용하여 프레임 내 오버레이 텍스트의 존재 유무를 먼저 판단한다. 오버레이 텍스트가 있다면, 색(color) 정보와 움직임(motion) 정보를 결합하여 오버레이 텍스트 그래픽 영역을 검색하고 추출한다. 실험에서는 여러 가지 장르의 방송용 비디오에 대한 처리 결과를 보여주고 분석했다.

복부대동맥의 3차원 표면모델링을 위한 가변형 능동모델의 적용 (Surface Rendering in Abdominal Aortic Aneurysm by Deformable Model)

  • 최석윤;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제9권6호
    • /
    • pp.266-274
    • /
    • 2009
  • 복부대동맥류는 주로 65-75세의 중년이후 남성과 흡연자에서 주로 발생한다. 가장 중요한 증세는 대동맥 파열로서 생명에 치명적이며, 혈관벽이 헐고 약해지고 파열되어 많은 양의 혈액이 복강 내로 쏟아지는 것을 의미한다. 복부대동맥박리를 치료하기 위해서는 3차원 영상 정보가 필요하고, 수술시 임상의사에게 많은 도움이 된다. 3차원 정보는 MDCT로부터 계산되고 3차원 모델은 2차원 CT영상의 분할로 계산된 좌표로부터 재구성된다. 따라서 3차원 영상의 질은 2차원 영상의 분할알고리듬에 의존적이다. 본 연구에서는 목적장기만을 모델링하기 위해서 가변형 능동모델을 제안한다. 가변형 능동모델은 외부힘에 의해서 에너지가 최소화되는 수렴하는 모델이다. 외부힘은 GVF로 불리며, 그레이레벨 또는 영상으로 부터의 이 진경계지도의 구배가 확산되는 것을 계산한다. 실험결과 복부대동맥박리에 적용해서 3차원 표면재구성을 성공했으며, 분할알고리듬의 특성으로 시각적 및 정량적인 평가도 성공했다.

서울지역 지하철역의 라돈농도 분포 특성 (Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations)

  • 전재식;김덕찬
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.588-595
    • /
    • 2006
  • 본 연구는 서울지역 지하철역 실내 공기 중 라돈분포를 조사하여 그 발생원을 추적 확인하기 위하여 수행되었다. 1998년부터 2004년까지 232개 역사를 대상으로 알파비적검출기를 사용하여 실내 공기 중 장기라돈을 측정하였으며 지하수중 라돈농도는 알파입자계수법에 의하여 측정하였다. 라돈의 주 발생원을 추적하기 위하여 8개 역사를 선정하여 각 역사의 승강장과 인접터널에 대한 공기 중 라돈농도를 조사하였다. 전체역사에 대한 라돈농도 분석결과 기하평균 및 산술평균은 각각 $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$였으며, 승강장과 매표소의 기하평균은 각각 $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$로 승강장에서의 라돈농도가 매표소의 농도보다 더 높게 나타났다. 지질구조와 지하역사의 라돈분포는 밀접한 상관성을 보였으며 터널내부와 지하수중의 라돈농도는 역사 승강장의 라돈농도에 크게 영향을 미치고 있었다. 또한 역사의 승강장이 위치하고 있는 깊이 정도에 따라 라돈농도의 차이를 보였다(p<0.05).

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

광역감시망 적용을 위한 HF 레이더 기반 선박 검출 및 추적 요소 기술 (Wide-area Surveillance Applicable Core Techniques on Ship Detection and Tracking Based on HF Radar Platform)

  • 조철진;박상욱;이영로;이상호;고한석
    • 대한원격탐사학회지
    • /
    • 제34권2_2호
    • /
    • pp.313-326
    • /
    • 2018
  • 현재 국내 환경에서의 HF 레이더는 기본적으로 표층해류의 속도와 방위의 측정에 최적화 되어있는 상태이다. 따라서, 이러한 환경하에서 선박을 탐지하는 데에는 큰 환경 잡음과 다수의 오검출로 인하여 기존의 선박 검출 및 추적 기술로는 정밀도에 한계점이 있다. 특히, 국내의 지형환경에 적합한 콤팩트형 HF(High Frequency) 레이더를 선박의 감시에 적용했을 경우에 나타나는 문제점들인 잡음과 간섭으로 인한 원신호 왜곡과 다수의 오검출이 발생하여 성능에 영향을 미치는 것을 극복하기 위한 검출 및 추적 기술이 요구된다. 본 논문에서는 이러한 조건 하에서 적용이 가능한 선박 검출 및 추적 기술을 제안을 하며, 서해에서 운용되고 있는 콤팩트 HF 레이더 사이트에서 획득한 관측 데이터에 적용하여 성능을 평가하였다. 제안된 기법은 선박의 검출에 대한 부분과 검출 결과의 추적에 대한 부분으로 이루어져 있다. 선박의 검출은 CFAR(Constant False Alarm Rate) 기반의 검출기를 활용하였으며, 실제 환경에서 불규칙적으로 획득되는 잡음과 오검출 신호를 줄이기 위한 PCA(Principal Component Analysis) 기반의 부분공간 분리기법을 적용하였다. 또한, 긴 입력 획득 주기(Coherent Processing Interval) 동안에 발생하는 도플러 주파수 변화로 인하여 하나의 선박이 다수의 검출값을 생성하기도 하는데, 이를 결합하기 위한 군집화 기법을 적용하였다. 선박의 검출 결과는 검출에 실패하거나 오검출을 포함시키는 경우도 발생하는데, 이러한 오검출을 줄이기 위한 선박 추적 기법을 적용하였다. 실험 결과에 따르면 제안된 선박 검출 및 추적 기술을 통하여 콤팩트 HF 레이더가 일정 거리에서 선박의 검출 성공율이 우수하다는 것을 확인할 수 있다.

간암 환자의 세기조절방사선치료 시 호흡에 의한 움직임 조건에서 측정된 조사면 별 선량결과를 기반으로 재계산한 체내 선량분포 평가 (Evaluation of Dose Distributions Recalculated with Per-field Measurement Data under the Condition of Respiratory Motion during IMRT for Liver Cancer)

  • 송주영;김용협;정재욱;윤미선;안성자;정웅기;남택근
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.79-88
    • /
    • 2014
  • 내부표적체적을 기반으로 계획된 간암 환자의 세기조절방사선치료에서 호흡에 의한 장기의 움직임 영향을 적용하여 체내 실제 종양 부피와 중요 장기 부피에서의 선량분포를 재계산하고, 호흡동조 방식의 세기조절방사선치료 계획 결과와 비교를 통한 선량적 특성을 분석하였다. 내부표적체적은 MIM 프로그램을 사용하여 형성하였고, 호흡에 의한 장기 움직임을 모사할 수 있는 구동 팬텀을 사용하였다. 체내 선량분포는 세기조절방사선치료의 품질보증 과정에서 2차원 다이오드 검출기 배열 장치인 MapCHECK2로 측정한 조사면 별 측정 결과를 기반으로 3DVH 프로그램으로 재계산 하였다. 내부표적체적 기반의 세기조절방사선치료 수행 시 계획표적체적에 충분히 처방선량이 조사되었지만, 선량의 균일도는 호흡동조 방식의 세기조절방사선치료와 비교 시 열등한 결과를 보였다. 상대적으로 더 큰 조사면을 사용하는 내부표적체적 기반의 세기조절방사선치료에서 손상위험장기체적에 더 높은 선량이 조사됨을 확인할 수 있었지만, 척수에 증가된 선량은 부작용 발생확률에 큰 영향을 주지 않는 적은 양이었고, 정상 간이나 신장 부위의 증가된 선량도 최적화 과정에서 좀 더 선량감소 조건을 강화한다면 큰 영향이 없을 것으로 평가되었다. 호흡동조 방식의 세기조절방사선치료가 치료계획에서는 더 좋은 선량분포를 보이고 있으나, 실제 구현 과정에서 다엽콜리메이터의 움직임 오류로 인한 선량의 오차와 치료시간의 증가 측면의 단점이 있으므로, 환자 호흡 상태 및 손상위험장기의 선량제한 값에 대한 사전 분석을 통해 환자 별 최적의 세기조절방사선치료 기법을 선정하여 적용하는 것이 타당하다고 생각된다.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.