• Title/Summary/Keyword: Manual count

Search Result 26, Processing Time 0.047 seconds

The Effectiveness and Safety of Dokwhalkisaeng-tang Combined with the Medication on Rheumatoid Arthritis: A Study Protocol for Systematic Review and Meta-analysis (류마티스 관절염 치료제와 병용한 독활기생탕의 효과 및 안전성: 체계적 문헌고찰 및 메타분석 프로토콜)

  • Chae, Soo-Yeon;Jung, Chan-Yung;Kim, Joo-Hee;Kim, Eun-Jung;Seo, Byung-Kwan;Hwang, Min-Seop;Park, Seong-Sik;Kim, Kyung-Ho;Yoon, Jong-hwa;Sung, Won-Suk
    • Herbal Formula Science
    • /
    • v.30 no.2
    • /
    • pp.95-100
    • /
    • 2022
  • Objectives : Recent studies reported that Dokwhalkisaeng-tang (DHJST) could relieve the clinical rheumatoid arthritis (RA) symptoms and the level of RA-related blood test. However, evidence-based review on effectiveness and safety of DHJST with medication on RA was not yet provided. Methods : Searching randomized controlled trials on the use of DHJST for RA will be performed using multiple electronic databases, manual search, and contact to author. Studies will be selected according to the pre-defined criteria and collected data on study participants, interventions, control groups, outcome measurements, the results, adverse events, and risk of bias will be summarized. Primary outcome will be the disease activity score (including effective rate, swollen joint count, tender joint count, and morning stiffness), and the secondary outcomes will be RA-related blood test and adverse events. We will use Review Manager software to perform a meta-analysis, Cochrane Collaboration "risk of bias" tool for assessing the risk of bias, and Grades of Recommendation, Assessment, Development and Evaluation for the determination of quality of evidence. Results : We are going to investigate the effectiveness and safety of DHJST with medication for RA. Conclusion : This study will provide reliable evidence on whether DHJST combined with medicine is more effective on RA than medicine monotherapy.

CNN Classifier Based Energy Monitoring System for Production Tracking of Sewing Process Line (봉제공정라인 생산 추적을 위한 CNN분류기 기반 에너지 모니터링 시스템)

  • Kim, Thomas J.Y.;Kim, Hyungjung;Jung, Woo-Kyun;Lee, Jae Won;Park, Young Chul;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.5 no.2
    • /
    • pp.70-81
    • /
    • 2019
  • The garment industry is one of the most labor-intensive manufacturing industries, with its sewing process relying almost entirely on manual labor. Its costs highly depend on the efficiency of this production line and thus is crucial to determine the production rate in real-time for line balancing. However, current production tracking methods are costly and make it difficult for many Small and Medium-sized Enterprises (SMEs) to implement them. As a result, their reliance on manual counting of finished products is both time consuming and prone to error, leading to high manufacturing costs and inefficiencies. In this paper, a production tracking system that uses the sewing machines' energy consumption data to track and count the total number of sewing tasks completed through Convolutional Neural Network (CNN) classifiers is proposed. This system was tested on two target sewing tasks, with a resulting maximum classification accuracy of 98.6%; all sewing tasks were detected. In the developing countries, the garment sewing industry is a very important industry, but the use of a lot of capital is very limited, such as applying expensive high technology to solve the above problem. Applied with the appropriate technology, this system is expected to be of great help to the garment industry in developing countries.

Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel (스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가)

  • Park, Eunjung;Kim, Subin;Cho, Myoung-Ock;Kim, Kyunghoon;Shourav, Mohiuddin Khan;Kim, Sunwook;Lee, Jeonghoon;Kim, Jung Kyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.19-28
    • /
    • 2015
  • With the aim of developing a smartphone-based point-of-care device that is small, inexpensive, and easy to handle by non-expert, we designed a fluorescence smartscope for counting particles and a DC motor-controlled particle positioning system. Our smartscope can count the number of fluorescent particles and fluorescently-stained white blood cells through a phone camera with an adaptor containing a LED, a ball lens and optical filters and an application running on a smartphone. The motor was controlled wirelessly via Bluetooth with an Android smartphone. We found that axial spinning of a helical microfluidic channel allows arrangement of particles having size similar to the white blood cells. The motor-controlled particle positioning system can minimize time-consuming manual processes and automate sample preparation process and thus, if integrated with the smartscope, it can be used for a point-of-care testing device based on a smartphone.

A Study on Hybrid Fuzzing using Dynamic Analysis for Automatic Binary Vulnerability Detection (바이너리 취약점의 자동 탐색을 위한 동적분석 정보 기반 하이브리드 퍼징 연구)

  • Kim, Taeeun;Jurn, Jeesoo;Jung, Yong Hoon;Jun, Moon-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.541-547
    • /
    • 2019
  • Recent developments in hacking technology are continuing to increase the number of new security vulnerabilities. Approximately 80,000 new vulnerabilities have been registered in the Common Vulnerability Enumeration (CVE) database, which is a representative vulnerability database, from 2010 to 2015, and the trend is gradually increasing in recent years. While security vulnerabilities are growing at a rapid pace, responses to security vulnerabilities are slow to respond because they rely on manual analysis. To solve this problem, there is a need for a technology that can automatically detect and patch security vulnerabilities and respond to security vulnerabilities in advance. In this paper, we propose the technology to extract the features of the vulnerability-discovery target binary through complexity analysis, and select a vulnerability-discovery strategy suitable for the feature and automatically explore the vulnerability. The proposed technology was compared to the AFL, ANGR, and Driller tools, with about 6% improvement in code coverage, about 2.4 times increase in crash count, and about 11% improvement in crash incidence.

A Study on the Early Computer Utilization in Korean Broadcasting: Focusing on the History of Election Broadcasting(1985-1992) (한국 방송에서 초기 컴퓨터 활용에 관한 연구: 선거 개표방송 변천사를 중심으로(1985년-1992년))

  • Nah, So-Mi
    • Journal of Digital Convergence
    • /
    • v.20 no.1
    • /
    • pp.301-307
    • /
    • 2022
  • Today, each broadcasting station makes the best use of CG (computer Graphics), which is the latest technology in election broadcasting, and competes to attract the eyes of viewers. This paper investigated the history of CG technology and design transitions in election ballot counting broadcasts from the perspective of CG designers. From the 1980s, when computer-based election ballot counting began, to the full-scale use of virtual studios, the image and technology produced by CG while watching the ballot-counting broadcast video of general elections, presidential elections, and local elections. We analyzed the utilization from various angles. In Korea, we started with the EDDS (Election Data Display System) developed in-house, created a database using a computer, and introduced manual animation CG every day from that time. After that, broadcasting stations focused on diverse and gorgeous CG image competition, and CG images were expanded from 2D to 3D while technology and design developed together. From 1985 to 1992, Korean broadcasting can be seen as a transitional period in which the image changes due to the emphasis on information power while utilizing digital technology.

Configurable Smart Contracts Automation for EVM based Blockchains

  • ZAIN UL ABEDIN;Muhammad Shujat Ali;Ashraf Ali;Sana Ejaz
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.10
    • /
    • pp.147-156
    • /
    • 2023
  • Electronic voting machines (EVMs) are replacing research ballots due to the errors involved in the manual counting process and the lengthy time required to count the votes. Even though these digital recording electronic systems are advancements, they are vulnerable to tampering and electoral fraud. The suspected vulnerabilities in EVMs are the possibility of tampering with the EVM's memory chip or replacing it with a fake one, their simplicity, which allows them to be tampered with without requiring much skill, and the possibility of double voting. The vote data is shared among all network devices, and peer-to-peer verification is performed to ensure the vote data's authenticity. To successfully tamper with the system, all of the data stored in the nodes must be changed. This improves the proposed system's efficiency and dependability. Elections and voting are fundamental components of a democratic system. Various attempts have been made to make modern elections more flexible by utilizing digital technologies. The fundamental characteristics of free and fair elections are intractability, immutability, transparency, and the privacy of the actors involved. This corresponds to a few of the many characteristics of blockchain-like decentralized ownership, such as chain immutability, anonymity, and distributed ledger. This working research attempts to conduct a comparative analysis of various blockchain technologies in development and propose a 'Blockchain-based Electronic Voting System' solution by weighing these technologies based on the need for the proposed solution. The primary goal of this research is to present a robust blockchain-based election mechanism that is not only reliable but also adaptable to current needs.

Change in the Microbial Profiles of Commercial Kimchi during Fermentation (국내 시판김치의 김치담금부터 숙성까지의 미생물 균총 변화)

  • Chang, Ji-Yoon;Choi, Yu-Ri;Chang, Hae-Choon
    • Food Science and Preservation
    • /
    • v.18 no.5
    • /
    • pp.786-794
    • /
    • 2011
  • To investigate the sanitary-quality level of commercial kimchi in South Korea, the pH, acidity, and microbial-flora changes in the kimchi were determined. Samples of kimchi produced by three different manufacturers (a small grocery store, a small/medium-sized enterprise, and a large food company) were collected. Freshly made kimchi was purchased and fermented at $10^{\circ}C$ for 10 days. The pH of the commercial kimchi on the purchased day was approximately pH 5.8, and that on the $10^{th}$ day of fermentation was ${\simeq}pH$ 4.1. The kimchi purchased from a large company showed a more rapid decline in pH level during fermentation. The saltiness of the kimchi purchased from a medium-sized company was slightly higher than those of the other commercial kimchi samples. The saccharinity index of the kimchi produced by a small grocery store was higher than those of the other samples, and its value deviation was also higher than those of the other commercial kimchi samples. A higher total viable-cell count and a higher lactic-acid bacteria (LAB) count were detected in the kimchi from the large food company at the beginning of fermentation compared to the samples of the two other kimchi manufacturers. The highest cell numbers of gram-positive bacteria (except LAB) and coliform bacteria were detected from the small-grocery-store kimchi, but the coliform bacteria count gradually decreased during fermentation although such bacteria were still detected until the $10^{th}$ day of fermentation. In contrast, coliform bacteria were not detected in the samples from the medium-sized and large food companies. Yeast, which is detected in over-ripened kimchi, was detected in the unfermented kimchi from the small grocery store, which had a below-0.36% acidity level. The gram-positive bacteria (except LAB) that were detected in all the tested commercial kimchi samples were determined to be Bacillus spp., and the gram-negative bacteria were determined to be Escherichia coli, Enterobacter spp., Sphingomonase spp., and Strenophomonas spp. The proportions of all the aforementioned bacteria in the kimchi samples, however, were different depending on the samples that were taken. These results indicate that a more sanitary kimchi production process and a more systematic kimchi production manual should be developed to industrialize and globalize kimchi.

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF

Analysis of Pathogenic Microorganism's Contamination on Cultivation Environment of Strawberry and Tomato in Korea

  • Oh, Soh-Young;Nam, Ki-Woong;Kim, Won-Il;Lee, Mun Haeng;Yoon, Deok-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.510-517
    • /
    • 2014
  • The purpose of this study was to analyze microbial hazards for cultivation environments and personal hygiene of strawberry and tomato farms at the growth and harvesting stage. Samples were collected from thirty strawberry farms and forty tomato farms located in Korea and tested for Staphylococcus aureus and Bacillus cereus. To investigate the change in the distribution of the S. aureus and B. cereus, a total of 4,284 samples including air born, soil or medium, mulching film, harvest basket, groves and irrigation water etc. were collected from eight strawberry farms and nine tomato farms for one year. As a result, total S. aureus and B. cereus in all samples were detected. Among the total bacteria of strawberry farms, S. aureus (glove: $0{\sim}2.1Log\;CFU/100cm^2$, harvest basket: $0{\sim}3.0Log\;CFU/100cm^2$, soil or culture media: 0~4.1 Log CFU/g, mulching film: $0{\sim}3.8Log\;CFU/100cm^2$), B. cereus (glove: $0{\sim}2.8Log\;CFU/100cm^2$, harvest basket: $0{\sim}4.8Log\;CFU/100cm^2$, soil or culture media: 0~5.3 Log CFU/g, mulching film: $0{\sim}4.5Log\;CFU/100cm^2$) were detected in all samples. The total bacteria of tomato farms, S. aureus (glove: $0{\sim}4.0Log\;CFU/100cm^2$, harvest basket: $0{\sim}5.0Log\;CFU/100cm^2$, soil or culture media: 0~6.1 Log CFU/g, mulching film: $0{\sim}4.0Log\;CFU/100cm^2$), B. cereus (glove: $0{\sim}4.0Log\;CFU/100cm^2$, harvest basket: $0{\sim}4.3Log\;CFU/100cm^2$, soil or culture media: 0~5.9 Log CFU/g, mulching film: $0{\sim}4.7Log\;CFU/100cm^2$) were detected in all samples. The contamination of S. aureus and B. cereus were detected in soil, mulching film and harvest basket from planting until harvest to processing, with the highest count recorded from the soil. But S. aureus and B. cereus were not detected in irrigation water samples. The incidence of S. aureus and B. cereus in hydroponics culture farm were less than those in soil culture. The amount of S. aureus and B. cereus detected in strawberry and tomato farms were less than the minimum amount required to produce a toxin that induces food poisoning. In this way, the degree of contamination of food poisoning bacteria was lower in the production environment of the Korea strawberry and tomato, but problems can be caused by post-harvest management method. These results will be used as fundamental data to create a manual for sanitary agricultural environment management, and post-harvest management should be performed to reduce the contamination of hazardous microorganisms.

Variation of Image Analysis Results for Determining the Characteristics of the Air-Void System on Hardened Concrete (콘크리트 공극구조 분석을 위한 화상분석결과의 변동성 분석)

  • Jeon, Sung-Il;An, Ji-Hwan;Lee, Jin-Beom;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.157-168
    • /
    • 2011
  • Recently, the cases of freeze-thaw distress on concrete pavement in domestic have been reported periodically. Hereupon, the necessity to establish the standard of spacing factor came to the fore. The test method for analyzing spacing factor is provided in the standard of ASTM C 457. Since researchers tend to judge study results subjectively, the results should be revised throughly. Image analysis program for determining the characteristics of air-void system on hardened concrete identify air void through the difference of a color. The pixel intensity values used in this program have a significant effect on the analysis results. This study compared the automated void count by varying pixel intensity values with the manual void count in order to determine the optimum range of pixel intensity values. Also, this study analyzed the air-void characteristics on eight kinds of concrete mixtures. In this study, it was confirmed that the variation of void counted manually was around 10% from the results of round robin test, and that the optimum range of pixel intensity values is around 80~90. And it was also confirmed that air content (as a whole) was increased generally and spacing factor was decreased by increasing air-entrainer content. But some concrete mixtures showed a tendency that air content was constant and spacing factor was decreased by increasing air-entrainer content. This causes the air entrained by air-entrainer has more influence on spacing factor than air content. Also, the deviation of spacing factor by cutting position of concrete specimen was about 30~100${\mu}m$ because of the limit of 2-D image analysis. The additional study about variation of spacing factor by cutting position of concrete specimen will be performed later.