• Title/Summary/Keyword: Manning coefficient

Search Result 83, Processing Time 0.027 seconds

Measurement of the Equivalent Resistance Coefficient for Multi-piers in Open Channel (개수로 다열기둥에 대한 상당저항계수의 측정)

  • Kwon, Kab Keun;Choi, Junwoo;Yoon, Sung Bum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6B
    • /
    • pp.635-642
    • /
    • 2008
  • The influence of unsubmerged resistance bodies in a channel turbulence flow on energy loss was investigated by hydraulic experiments. Square-shaped multi-piers were used for unsubmerged structure or rigid vegetation in an open channel. In experimental channel flows multi-piers were arranged in double or single row along the channel direction, and mean-concept uniform elevations were attained and measured with a set of discharges and channel slopes. Applying the experimental results to the Manning equation, the equivalent resistance coefficient n, which implicates flow resistance and energy loss due to bottom friction as well as drag, was evaluated with varying the interval of piers and the uniform water depth. And the experimentally evaluated n values were compared with the semi-theoretical formula of the equivalent resistance coefficient derived from momentum analysis including a drag interaction coefficient. From the comparisons it was found that the interaction effect of piers on flow resistance was significant for the overall energy losses in a channel flow. The n values decrease when the interval of piers in flow-direction is less than about 2.2 times of the pier width. And it was also found that the n values increase with the 2/3 power of water depth in the theoretical formula, since the drag interaction coefficient was found to be mostly dependent on the interval of piers.

Estimation of Average Roughness Coefficients of Bocheong Stream Basin (보청천 유역의 평균조도계수 산정)

  • Jeon, Min-Woo;Lee, Hyo-Sang;Ahn, Sang-Uk;Cho, Young-Soo;Jeon, Man-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1306-1310
    • /
    • 2009
  • The roughness coefficients were estimated by the Manning's equation for the measured stage and flow velocity of Bocheong stream basin in Kum river. The relationships between the estimated roughness coefficients and the geomorphologic factors were formulated by the linear, logarithmic, exponential and power type function, thereafter correlation equations were presented. The correlation analysis was performed between the measured stream length and the basin area of Bocheong stream basin by the linear, logarithmic, exponential and power type function, and correlation equation for the stream length was given. The roughness coefficient has strong correlationship with stream slope, but low correlation coefficients with stream length and basin area. For the correlationship with the roughness coefficients and the stream slope, the logarithmic type function has the smallest correlation coefficient, on the other hand, the exponential type function has the largest correlation coefficient. For the relationship between the stream length and the basin area, the correlation coefficient of the logarithmic type function shows the smallest value, linear type function shows the largest value.

  • PDF

Urban Flood Simulation Considering Buildings Resistance Coefficient Based on GIS: Focused on Samcheok City (건물 저항계수에 따른 GIS기반의 밀집 시가지 침수모의 -삼척시가지를 중심으로-)

  • Ji, Juong-Hwan;Kang, Sang-Hyeok
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.211-220
    • /
    • 2010
  • The objective of this paper presents the application of an "integrated urban flood modeling-runoff model, urban flood model and sewer system model-" in a highly urbanized area of Samcheok where is seriously inundated in 2002 and 2003. For this, we demonstrate how couple a 1-D hydrodynamic model of the river, a 2-D hydrodynamic model of the overland (surface) flow, and a sewer network model including each boundary conditions. In order to make data file for the model, topographic information like elevation and share rate of buildings are directly extracted from DEM or topographical source data without data exchange to avoid uncertainty errors. Furthermore, the research is to assess the impacts of Manning n and buildings influences to inundated depth by changing its share ratio from 10 % to 30 % in low-land urban area. As a results, we found out that the urban inundated depth was decreased by Manning n but increased by buildings ratio. The calculated results of inundation was similar with observed one in 2002 and 2003 flooding. Furthermore, the area was also inundated under not riverbank break case in 2002 flooding.

A Study on the Design of Artificial Stream for Riverbed Filtration in Multi-purpose Filtration Pond (다목적 여과저류지에서의 하상여과용 인공하천 설계연구)

  • Sohn, Dong-Hoon;Park, Jae-Young;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.536-543
    • /
    • 2011
  • In order to find the best design of artificial stream for the riverbed filtration in multi-purpose filtration pond, a mathematical model was developed employing the energy line and the Manning's formula and was analyzed by the Euler's technique. Various design factors were investigated through scenario analyses of the artificial stream using the model. Results showed that the appropriate slope of the stream bottom was 2/10,000 and the appropriate infiltration rate at the streambed was $2.5m^3/m^2-day$ for the pond with the area of 100 ha, and that the Manning's roughness coefficient in this case was expected to be about 0.026 and the maximum water-depth was less than 1m. It was also shown that the longer the artificial stream the more advantageous it became for the riverbed filtration. Furthermore, results showed that it was not an efficient way to prevent clogging of the streambed by increasing the flow velocity of the stream and that the performance was higher near a weir with a large head drop.

Two-dimensional Numerical Modeling of Water Quality Variation by Gates Operation in the Seonakdong River (수문운영에 따른 서낙동강 수질변화에 관한 이차원 수치모의)

  • Lee, Namjoo;Kim, Young Do;Kwon, Jae Hyun;Shin, Chan Ki
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.101-112
    • /
    • 2007
  • This study has used RMA2 model and RMA4 model, which are depth-averaged two-dimensional flow and water-quality prediction models, to analyze the variation of the water-quality by the gates operation in the Seonakdong River. Sensitivity analysis is performed to get the Manning coefficient and the coefficient of eddy viscosity for RMA2 model, and to get the diffusion coefficient for RMA4 model. Since the numerical simulation using RMA2 and RMA4 models did not consider tributary pollutant load except for that of Joman River, it could make a little difference from the natural phenomenon. Nevertheless, the numerical simulation shows that the discharge of $30m^3/s$, which is the continuous inflow from the Daedong-gate, can make it possible to achieve the target water-quality (BOD 4.3mg/L) of Nakbon-N watershed about 10 days later if the Daejeo-gate could remain opened in connection with the Noksan-gate operation.

Roughness Coefficient of Collector Well Lateral in a Model Riverbed Filtration (하상여과 모형에서 수평집수관의 조도계수)

  • Kim, Woo-Chul;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.176-183
    • /
    • 2007
  • In order to analyze the experimental results obtained from the model riverbed filtration performed by Ahn et al. a mathematical model was developed to simulate the flow through the lateral. The discharge rates at each section of the lateral measured by Ahn et al. were compared with the model predictions, and they matched favorably. The Manning's roughness coefficients of all the laterals employed in the study of Ahn et al. were determined using the model. Results show that the roughness coefficient becomes larger with the increase in the entrance velocity to the collector well, and that the coefficient ranges from 0.012 to 0.015 under the normal operational conditions of the riverbed filtration. Results also show that the coefficient becomes smaller as the lateral diameter increases.

Application of Depth-averaged 2-D Numerical Model for the Evaluation of Hydraulic Effects in River with the Riparian Forest (하안림 영향 검토를 위한 수심평균 2차원 수치모형 적용)

  • Kim, Ji Sung;Kim, Won;Kim, Hyea Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2B
    • /
    • pp.165-173
    • /
    • 2011
  • In this study, FESWMS FST2DH model was used to analyze the change of flow characteristics after making the riparian forest. The additional flow resistance is calculated based on the drag-force concept acting on each tree and the lateral momentum transfer between planted and non-planted zone could be satisfactorily reproduced by parabolic turbulence model in this depth-averaged 2-D numerical model. For model validation, the simulated velocities were compared with the measured data, showing good agreement in both tree density cases of experiments. The previous method using a proper Manning's n coefficient gives reasonable solutions only to evaluate the conveyance, but the calculated approach velocity at each tree was different from realistic value. The proposed procedure could be widely used to evaluate hydraulic effects of riparian trees in practical engineering.

A Study on Trapping Efficiency of the Non-point Source Pollution in Cheongmi Stream Using VFSMOD-w (VFSMOD-w 모형을 이용한 청미천 유입 비점오염물 저감효율 연구)

  • Son, Minwoo;Byun, Jisun;Yoon, Hyun-Doug;Jung, Tae-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.140-150
    • /
    • 2016
  • This study aims to investigate the effect of vegetation type, length of vegetative filter strip, and rainfall on trapping efficiency of the non-point source water pollution. Numerical experiments are carried out using VFSMOD-w. It is known from this study that the vegetation having the same value of revised Manning roughness coefficient shows the similar trapping efficiency in VFSMOD-w. When the length of vegetative filter strip increases twice, the trapping efficiency increases negligibly small under the same condition of rainfall. From this finding, it is also known that most of sediment are removed within a certain length of vegetative filter strips. It is concluded that the installation of vegetative filter strip is determined under the consideration of the rainfall characteristics, space of vegetation, and length of vegetative filter strip.

Hydraulic Model for Real Time Forecasting of Inundation Risk (실시간 범람위험도 예측을 위한 수리학적 모형의 개발)

  • Han, Geon-Yeon;Son, In-Ho;Lee, Jae-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.3
    • /
    • pp.331-340
    • /
    • 2000
  • This study aims to develop a methodology of real time forecasting of mundation risk based on DAMBRK model and Kalman filter. The model is based on implicit, nonlinear finite difference approximatIons of the one-dimensional dynamic wave equations. The stochastic estimator uses on extended Kalman filter to provide optimal updating estimates. These are accomplished by combining the predictions of the determurustic model with real time observauons modified by the Kalman filter gain ractor. Inundation risks are also estimated by applying Monte Carlo simulation to consider the variability in cross section geometry and Manning's roughness coefficient. The model calibrated by applying to the floods ot South Han River on September, 1990 and August, 1995. The Kalman tilter model indicates that significant improvement compared to deteriministic analysis in flood routing predictions in the river. Overtopping risk of levee is also presented by comparing levee height with simulated flood level. level.

  • PDF

Estimation of Muskingum-Cunge Parameters for Natural Streams (자연하천에 대한 Muskingum-Cunge 모형의 매개변수 산정)

  • Kim, Jin-Soo;Jun, Kyung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.233-243
    • /
    • 2010
  • A method is proposed of estimating Muskingum-Cunge parameters for natural streams using cross-sectional and longitudinal channel geometry and roughness coefficient data. Firstly, for various water-surface levels at a cross section cross-sectional areas and hydraulic radii are calculated. Corresponding discharges are then calculated using Manning's equation. This procedure is repeated for all cross-sections in the reach. Finally, routing parameters are estimated from the calculated cross-sectional area and discharge value pairs by regression analysis. The procedures for estimating Muskingum-Cunge parameters are applied to the South Han River. Flows calculated by Muskingum-Cunge model with estimated parameters showed much better agreement with those by dynamic wave model in peak discharge, time to peak discharge, and normalized RMS errors than those calculated by the HEC-1 Muskingum-Cunge model.