• Title/Summary/Keyword: Manganese porphyrins

Search Result 2, Processing Time 0.014 seconds

An Isothermal Titration Microcalorimetric Study on the Interaction of Three Water-Soluble Porphyrins with Histone H2B

  • Bordbar, A.K.;Ghaderi, A.R.;Safaei, E.;Tangestaninejad, S.;Eslami, A.;Saboury, A.A.;Moosavi Movahedi, A.A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.547-551
    • /
    • 2003
  • In the present work, the interaction of three water soluble porphyrins, tetra(p-trimethyle) ammonium phenyl porphyrin iodide (TAPP) as a cationic porphyrin, tetra sodium meso-tetrakis (p-sulphonato phenyle) porphyrin (TSPP) as an anionic porphyrin and manganese tetrakis (p-sulphonato phenyl) porphinato acetate (MnTSPP) as a metal porphyrin, with histone H₂B have been studied by isothermal titration microcalorimetry at 8 mM phosphate buffer, pH 6.8 and 27 °C. The values of binding constant, entropy, enthalpy and Gibbs free energy changes for binding of the first MnTSPP, and first and second TSPP and TAPP molecules were estimated from microcalorimetric data analysis. The results represent that the process is both entropy and enthalpy driven and histone induces self-aggregation of the porphyrins. The results indicate that both columbic and hydrophobic interactions act as self-aggregation driving forces for the formation of aggregates around histone.

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.