• 제목/요약/키워드: Mandibular premolar

검색결과 364건 처리시간 0.023초

표면처리가 다른 5종 임플랜트의 안정성에 관한 연구 (A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS)

  • 김선종;신상완;정성민;류재준
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

백악질 골화성 섬유종의 치과적 접근 : 증례보고 (DENTAL MANAGEMENT OF CEMENTO-OSSIFYING FIBROMA: A CASE REPORT)

  • 한지혜;백병주;양연미;이선영;김재곤
    • 대한소아치과학회지
    • /
    • 제32권2호
    • /
    • pp.200-206
    • /
    • 2005
  • 백악질 골화성 섬유종은 가장 흔히 발생하는 섬유 골성 병소(fibro-osseous lesion)로서, 경계가 분명하고, 느리게 성장하는 팽창성의 양성종양이다. 임상적으로 하악골의 소구치와 대구치 부위에서 발생하고, 여성에게서 2배 정도 호발하며, 주로 20대에서 30대 사이에서 발견된다. 백악질 골화성 섬유종은 섬유성 이형성증을 포함한 다른 섬유 골성 병소와 감별되어야 한다. 백악질 골화성 섬유종의 또 다른 형태인 유년형 골화성 섬유종은 15세 이하에서 발생하며, 빠르게 성장하고, 좀 더 골파괴적인 양상을 보인다. 치료는 병소의 크기 에 따른 절제술이고, 재발은 드물다고 알려져 있다. 본 증례는 우측 하악 견치의 미맹출을 주소로 내원한 12세 남자 어린이로, 백악질 골화성 섬유종으로 진단 후, 외과적 적출술을 시행하여 양호한 치유과정을 보이기에 보고하는 바이다.

  • PDF

임플란트 디자인이 식립 회전력과 응력에 미치는 영향에 관한 삼차원 유한요소 분석 (Effect of Implant Designs on Insertion Torque and Stress : Three-Dimensional Finite Element Analysis)

  • 김장응;최유성;임종화;조인호
    • 구강회복응용과학지
    • /
    • 제26권2호
    • /
    • pp.205-220
    • /
    • 2010
  • 본 연구에서는 임플란트 디자인이 주입회전력과 주변 응력에 미치는 영향을 알아보고자 삼차원 유한 요소 분석을 이용하여 유효 응력과 모멘트 그리고 축력을 측정, 비교 조사하였다. 나사형 임플란트 매식체의 디자인을 4종의 평행형과 7종의 근첨형으로 구분하였고 하악골 소구치 부위에 식립한 것으로 가정하여 유한 요소 모델을 제작하였다. 각각의 임플란트가 식립될 때 주변부에 발생하는 응력을 분석하였으며 그 결과 근첨형 임플란트가 평행형 임플란트에 비해 높은 식립 회전력을 보여 초기 고정력이 우수할 것으로 예상되었으나 응력 분산 측면에 있어서는 효율성이 낮은 양상을 나타내었다. 근첨형 임플란트에 비해 평행형 임플란트가 나사산의 높이에 따른 영향을 크게 받는 것으로 나타났으며 근첨형 임플란트는 임플란트 몸체의 경사도가 증가함에 따라 높은 응력이 발생되는 것이 관찰되었다.

나사유지형 임플란트 고정성 보철물의 적합도와 캔틸레버가 지지골조직의 응력분산에 미치는 영향 (The Effects of Screw Retained Prosthesis Misfit & Cantilever on Stress Distribution in Bone Around the Implant)

  • 이재인;김태영;조혜원
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.224-235
    • /
    • 2013
  • 임플란트의 장기적인 성공을 위해 고정체의 형태, 외과적 술식, 골조직의 조건, 보철물 적합성, 주기적인 검사, 환자의 구강 위생 등에 많은 주의가 필요하다. 많은 연구에서 임플란트 지지 보철물의 적합도에 따른 임플란트의 예후에 관해 보고되었다. 보철물이 수동 적합되어야 임플란트의 상부구조및 하부구조에 해로운 응력을 야기하지 않는다고 보고되고 있으나 현재의 임플란트 보철물의 제작과정으로 진정한 수동 적합을 얻는 수 없다고 인정된다. 임상과정과 기공과정을 포함하여 임플란트 치료의 전 과정에서 오차가 발생하며, 이는 보철물을 변형을 야기하고 이는 임플란트 상부 보철물과 지대주 사이의 오차를 발생시킨다. 이러한 오차는 보철물 장착 후 보철물의 파절, 나사의 헐거움(screw loosening), 골소실, 골유착 실패와 같은 문제를 야기한다. 이런 오차에 의한 문제점은 cantilever의 존재, 과도한 교합력이 존재할 경우 더욱 증가된다고 보고되고 있다. 본 연구에서는 ITI 임플란트를 하악골의 견치후방의 무치악부에 3개를 식립하고 4-unit 캔틸레버 고정성 국소의치를 다양한 위치의 $100{\mu}m$ gap을 생성한 후 제작하고 gap을 생성하지 않은 고정성 국소의치와 30 lb의 하중하에서 광탄성 응력분석을 시행하여 응력분포 양상과상대적인 응력의 크기를 비교분석하였다.

Development of animal experimental periodontitis models

  • Do, Min-Jae;Kim, Kyuri;Lee, Haeshin;Cha, Seho;Seo, Taegun;Park, Hee-Jung;Lee, Jeong-Soon;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제43권4호
    • /
    • pp.147-152
    • /
    • 2013
  • Purpose: An animal periodontitis model is essential for research on the pathogenesis and treatment of periodontal disease. In this study, we have introduced a lipopolysaccharide (LPS) of a periodontal pathogen to the alveolar bone defect of experimental animals and investigated its suitability as a periodontitis model. Methods: Alveolar bone defects were made in both sides of the mandibular third premolar region of nine beagle dogs. Then, the animals were divided into the following groups: silk ligature tied on the cervical region of tooth group, Porphyromonas gingivalis LPS (P.g. LPS)-saturated collagen with silk ligature group, and no ligature or P.g. LPS application group as the control. The plaque index and gingival index were measured at 0 and 4 weeks postoperatively. The animals were then euthanized and prepared for histologic evaluation. Results: The silk ligature group and P.g. LPS with silk ligature group showed a significantly higher plaque index at 4 weeks compared to the control (P<0.05). No significant difference was found in the plaque index between the silk ligature group and P.g. LPS with silk ligature group. The P.g. LPS with silk ligature group showed a significantly higher gingival index compared to the silk ligature group or the control at 4 weeks (P<0.05). Histologic examination presented increased inflammatory cell infiltration in the gingival tissue and alveolar bone of the P.g. LPS with silk ligature group. Conclusions: An additional P.g. LPS-saturated collagen with silk ligature ensured periodontal inflammation at 4 weeks. Therefore, P.g. LPS with silk ligature application to surgically created alveolar bone defects may be a candidate model for experimental periodontitis.

하악골에 발생한 거대한 cemento-ossifying fibroma의 치험례 (A CASE REPORT OF THE HUGE CEMENTO-OSSIFYING FIBROMA OF THE MANDIBLE)

  • 이상철;김여갑;류동목;이백수;권용대;박종오
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제22권1호
    • /
    • pp.70-75
    • /
    • 2000
  • 본과에서는 하악에서 발생한 거대한 백악질-골성 섬유종에서 원발병소부위에 대한 광범위한 외과적 적출술 및 후방 장골이식을 통해 환자의 심미적, 기능적 안정성을 이루었으며 이환치아의 발거와 함께 술후 악간고정을 통하여 얇아진 하악하연부의 병적골절을 방지하였다. 현재까지 병소의 재발은 없고 양호한 결과를 보이고 있으며 향후 보철수복과 함께 지속적인 평가를 요할 것으로 사료된다.

  • PDF

편측성 후방연장 국소의치의 의치상에 이탈력이 가해질 때 간접유지장치가 장착된 치아 주위조직에 발생하는 응력에 관한 광탄성 분석 (A PHOTOELASTIC STRESS ANLYSIS IN THE SURROUNDING TISSUES OF TEETH SEATED BY INDIRECT RETAINERS WHEN APPLIED DISLODGING FORCES ON UNILATERAL DISTRAL EXTENTION PARTIAL DENTURES)

  • 손지영;이청희;조광헌
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.415-430
    • /
    • 1996
  • 하악좌측 제1대구치와 하악 좌측 제2대구치, 하악우측 제2소구치를 주지대치로 사용하고 하악우측 제1대구치와 하악 우측 제2대구치가 상실된 Kennedy 분류 II급 후방연장 국소의치에서 하악좌측 측절치에 incisal hook rest를 간접유지장치로 가지는 경운(Model I), 하악좌측 견치에 cingulum rest를 간접유지장치로 가지는 경우(Model II), 하악좌측 제1소구치에 근심교합면 레스트를 간접유지장치로 가지는 경우(Model III)의 모형에서, 상실된 하악우측제2대구치의 원심 변연융선에 해당하는 부위에 고리를 형성하여 교합평면에서 전상방 $45^{\circ}$ 각도로 860gm의 이탈력을 가하여 간접유지장치가 장착된 지대치와 양쪽 인접치 주위조직에 발생하는 응력을 비교분석한 바 다음과 같은 결론를 얻었다. 3가지 모형 모두에서 지대치의 치근단 부위보다는 치경부의 협측부위와 근원심 부위에 압축응력이 나타났다. 지대치의 설측 치경부에는 3가지 모형 모두에서 약한 인장응력이 나타났다. 협측부위의 압축응력의 크기는 Model I이 가장 컸고, Model II, Model III순으로 나타났다. Model I과 Model II에서 지대치의 근심과 원심 치경부에 압축응력이 나타났으며, 압축응력의 크기는 Model I이 Model II보다 더 컸다. Model III에서는 지대치의 근심치경부에서만 압축응력이 나타났다. 전반적으로 압축응력의 크기는 Model I이 가장 컸고, Model II, Model III의 순으로 나타났다.

  • PDF

상아질 접착제의 두께가 치아와 복합레진 경계의 응력발생에 미치는 영향에 관한 유한요소법 연구 (THE EFFECTS OF DENTIN BONDING AGENT THICKNESS ON STRESS DISTRIBUTION OF COMPOSITE-TOOTH INTERFACE : FINITE ELEMENT METHOD)

  • 박상일;김예미;노병덕
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.442-449
    • /
    • 2009
  • 이 연구의 목적은 5급 와동의 복합레진 수복에서 상아질 접착제를 비교적 두껍게 도포하거나 낮은 탄성계수(low elastic modulus)를 가진 복합레진을 선택하는 방법을 택하여 수복물의 탄성율의 차이에 따른 치아와 복합레진 경계에서 발생하는 응력의 차이를 알아보는 것이었다. abfraction 병소가 있는 하악 제 1소구치를 유한요소법을 이용하여 모델로 만들었다. 병소는 상아질 접착제의 두께 ($50{\mu}m$, $100{\mu}m$, $150{\mu}m$) 및 복합레진의 종류를 달리하며 수복되었다. 170N의 교합압을 협측 또는 설측에서 가하여 상아질 접착제와 치아면에서의 Von Mises stress를 측정하였다. 상아질 접착제의 두께가 두꺼울수록 상아질 접착제면에 가해지는 Von Mises stresss 는 감소하였다. 낮은 탄성계수 값을 가진 복합레진에서 Von Mises stress가 더 작았다. 치근상아질 경계 (margin)가 법랑질 경계에서보다 더 큰 응력이 발생하였다. 상아질 접착제면에 작용하는 교합압의 영 향을 감소시키기 위해 상아질 접착제를 두껍게 바르거나 낮은 탄성계수 값을 가진 복합레진을 사용하는 것이 추천된다.

하악 부분 무치악 환자에서 디지털 가이드 수술을 이용한 임플란트 융합 가철성 국소의치 수복 증례 (Implant-assisted removable partial denture using digital guide surgery in partially edentulous mandible: A case report)

  • 김태훈;정창모;윤미정;이소현;이현종;허중보
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.88-96
    • /
    • 2021
  • 다수 치아가 상실된 부분 무치악 환자에서 고정성 임플란트 보철, 가철성 국소의치를 이용한 치료와 더불어 최근에는 임플란트를 보조적으로 이용한 임플란트 융합 국소의치 또한 많이 이용되고 있다. 이중 부착 장치와 서베이드 고정성 보철물을 함께 이용하는 임플란트 융합 국소의치의 경우, 부착 장치와 국소의치가 동일한 삽입로를 가지도록 하는 것이 중요하다. 본 증례의 환자는 하악 국소의치를 사용하던 중, 불편감을 주소로 내원하여 임플란트 서베이드 고정성 보철물을 활용한 임플란트 융합 국소의치를 제작하였다. 이후 추가적인 임플란트 식립 시, 기존의 임플란트 서베이드 고정성 보철물의 삽입로와 동일한 식립 방향을 설정하기 위하여 디지털 가이드 수술을 이용하였다. 임플란트 식립 후, 좌, 우측 소구치부에는 로케이터를 장착하고, 좌측 구치부에는 치유 지대주 상태로 국소의치의 지지를 부여하여 제작하였다. 이를 통해 심미적, 기능적으로 만족할 만한 결과를 얻었기에 보고하는 바이다.

최대교두감합위 및 하악 전방운동 시의 교합접촉 및 교합유도 양상에 관한 분석 (Analysis of occlusal contact and guidance pattern during maximal intercuspal position and protrusive movement)

  • 김지연;김강현;노관태;김형섭;우이형;배아란
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.199-207
    • /
    • 2013
  • 연구 목적: 저작 및 하악 운동시 발생되는 치아접촉은 치열의 보존, 하악의 안정과 보철 수복과정에 있어서 중요하다. 이에 한국인의 20-30대 성인을 대상으로 최대교두감합위에서의 치아접촉점의 위치 및 교합유도양상과 교합유도치의 분포를 분석하여 알아보고자 한다. 연구 대상 및 방법: 29명의 성인을 대상으로 하악의 최대교두감합위에서의 치아접촉점의 위치와 분포 및 전방운동시 교합접촉양상을 shimstock foil (Whaledent, Langenau, Germany), T-Scan III (Tekscan Inc., Boston, MA, USA), polyvinylsiloxane registration material (Genie Bite, Sultan Healthcare, Hackensack, NJ, USA)을 이용하여 측정하였다. 측정시 자세는 직립위로 Frankfurt horizontal plane과 지면이 수평이 되도록 앉게 하였으며 접촉이 재현될 때까지 수 차례 반복한 후 3회씩 측정하였다. 최대교두감합위에서 세가지 방법 간의 통계적 유의성을 비교하기 Fisher's Exact Test (R-General Public License, ver. 2.14.1)를 이용하였고, 전방 운동시 Pearson's Test를 통해 통계 검증하였다(${\alpha}=.05$). 결과: 최대교두감합위에서의 치아 접촉 양상을 shimstock foil, T-Scan III, polyvinylsiloxane registration material로 측정시 전치부, 소구치부, 구치부 모두에서 접촉하는 경우가 대부분이었으며, shimstock 사용시 약51%의 최대교두감합위는 전치부 접촉에서 일어났다. Shimstock foil과 T-Scan III를 사용하여 전방운동 측정시 중절치의 접촉이 가장 많이 일어났다. 결론: 최대교두감합위에서 실제 모든 치아의 접촉이 이루어지지 않는 경우가 있었으며 따라서 구치부에서 전치부를 보호해 주고 있음을 확인할 수 있었다. 또한, 전방운동 시 전치부의 치아접촉은 과도한 구치부의 치아접촉을 방지해 전치부가 구치부를 보호해 주고 있었다. 따라서 교합 재구성 시에는 이러한 상호 보호 교합에 대한 고려가 필요하다.