• Title/Summary/Keyword: Mandibular fracture

Search Result 339, Processing Time 0.026 seconds

Retrieval of a separated nickel-titanium instrument using a modified 18-guage needle and cyanoacrylate glue: a case report

  • Andrabi, Syed Mukhtar-Un-Nisar;Kumar, Ashok;Iftekhar, Huma;Alam, Sharique
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.2
    • /
    • pp.93-97
    • /
    • 2013
  • During root canal preparation procedures, the potential for instrument breakage is always present. When instrument breakage occurs, it leads to anxiety of the clinician and as well as a metallic obstruction of the canal which hinders further cleaning and shaping. Separated instruments must always be attempted for retrieval and if retrieval is not possible bypass should be tried. With the increased use of nickel-titanium (NiTi) instruments the incidence of separated instruments has increased. A considerable amount of research has been done to understand the various factors related to the fracture of NiTi instruments to minimize its occurrence. This paper presents a review of the literature regarding the fracture of NiTi instruments and also describes a case report showing the use of a modified 18-guage needle and cyanoacrylate glue to retrieve a separated NiTi instrument from the mesiolingual canal of a mandibular first molar.

Retrospective clinical study of mandible fractures

  • Jung, Hai-Won;Lee, Baek-Soo;Kwon, Yong-Dae;Choi, Byung-Jun;Lee, Jung-Woo;Lee, Hyun-Woo;Moon, Chang-Sig;Ohe, Joo-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • Objectives: The purpose of this article is to analyze the incidence, demographic distribution, type, and etiology of mandible fractures that were treated by the Department of Oral and Maxillofacial Surgery in Kyung Hee University Dental Hospital from January 2002 to December 2012. Materials and Methods: This was a descriptive and analytic retrospective study that evaluated 735 patients that were treated for mandible fracture. Results: This study included 1,172 fractures in 735 patients. The ratio of male to female patients was 5.45 : 1; the maximum value was in patients between 20 and 29 years (38.1%) and the minimum in patients over 70 years old. The monthly distribution of facial fractures peaked in the fall and was lower during winter. No specific correlation was identified based on the annual fracture distribution. Among the 735 fracture patients, 1.59 fracture lines were observed per patient. The most frequent site was the symphysis, which accounted for a total of 431 fractures, followed by the angle (348), condyle (279), and body (95). The symphysis with angle was the most common site identified in combination with fracture and accounted for 22.4%, followed by symphysis with condyle (19.8%). The angle was the most frequent site of single fractures (20.8%). The major cause of injury was accidental trauma (43.4%), which was followed by other causes such as violence (33.9%), sports-related accidents (10.5%), and traffic accidents (10.1%). Fracture incidents correlated with alcohol consumption were reported between 10.0%-26.9% annually. Conclusion: Although mandible fracture pattern is similar to the previous researches, there is some changes in the etiologic factors.

Delayed Reduction of Facial Bone Fractures (정복 시기가 지난 안면골 골절의 수술적 교정)

  • Lee, Kyu-Seop;Park, Jae Beom;Song, Seung Han;Oh, Sang Ha;Kang, Nak Heon
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.2
    • /
    • pp.119-123
    • /
    • 2013
  • Except for special situations, it is generally agreed that best results in the treatment of facial fractures is expected if reduction is done within the first 2 or 3 weeks after injury. We reduced facial bone fractures at 4 to 7 weeks after trauma. A 44-year-old female patient underwent open reduction for her right zygomaticomaxillary complex fracture at 7 weeks after injury. A 59-year-old female patient underwent surgery for the right mandible body and left parasymphysis fractures at 4 weeks after injury. Using traditional approaches, granulation tissue and callus were removed from the fracture sites, and malunited fracture lines were separated by a small osteotome. We reduced the displaced fractured zygoma and mandible to their normal anatomical positions and fixed them using titanium plates. No complications such as asymmetry, malunion, malocclusion, or trismus were seen. Unfavorable asymmetric facial contours were corrected, and we obtained good occlusion with favorable bony alignment. The functional and aesthetic outcomes were satisfactory. Through removal the callus and limited osteotomy, a successful approach to the previously fractured line was possible, and an exact correction with symmetry was obtained. This method can be a good option for obtaining good mobility and clinical results in treating delayed facial bone fractures.

Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems

  • Ramyadharshini, Tamilkumaran;Sherwood, Inbaraj Anand;Vigneshwar, V Shanmugham;Prince, Prakasam Ernest;Vaanjay, Murugadoss
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.22.1-22.10
    • /
    • 2020
  • Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.

EFFECT OF ANCHORAGE SYSTEMS ON LOAD TRANSFER WITH MANDIBULAR IMPLANT OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS (하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향)

  • Kim Jin-Yeol;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.507-524
    • /
    • 2002
  • Load transfer of implant overdenture varies depending on anchorage systems that are the design of the superstructure and substructure and the choice of attachment. Overload by using improper anchorage system not only will cause fracture of the framework or screw but also may cause failure of osseointegration. Choosing anchorage system in making prosthesis, therefore, can be considered to be one of the most important factors that affect long-term success of implant treatment. In this study, in order to determine the effect of anchorage systems on load transfer in mandibular implant overdenture in which 4 implants were placed in the interforaminal region, patterns of stress distribution in implant supporting bone in case of unilateral vertical loading on mandibular left first molar were compared each other according to various types of anchorage system using three-dimensional photoelastic stress analysis. The five photoelastic overdenture models utilizing Hader bar without cantilever using clips(type 1), cantilevered Hader bar using clips(type 2), cantilevered Hader bar with milled surface using clips(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4), and Hader bar using clip and ERA attachments(type 5), and one cantilevered fixed-detachable prosthesis(type 6) model as control were fabricated. The following conclusions were drawn within the limitations of this study, 1. In all experimental models. the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. Maximum fringe orders on ipsilateral distal implant supporting bone in a ascending order is as follows: type 5, type 1, type 4, type 2 and type 3, and type 6. 3. Regardless of anchorage systems. more or less stresses were generated on the residual ridge under distal extension base of all overdenture models. To summarize the above mentioned results, in case of the patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant and unfavorable antero-posterior spread. selecting resilient type attachment or minimizing distal cantilever bar is considered to be appropriate methods to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

Evaluation of the course of the inferior alveolar canal in the mandibular ramus using cone beam computed tomography

  • Kwon, Kyung-Hwan;Sim, Kyu-Bong;Lee, Jae-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.231-239
    • /
    • 2012
  • Objectives: This study sought to provide guidelines in order to decrease the incidence of nerve injury during mandibular ramus bone harvesting, and to improve understanding of the anatomical structure of the inferior alveolar canal (IAC) to include its distance from the exterior buccal cortex. Materials and Methods: In January and February 2009, 20 patients who visited the Wonkwang University Department of Oral and Maxillofacial Surgery reporting various conditions underwent cone beam computed tomography and were included in this study. Patients with missing left or right mandibular first molars or incisors, or who had jaw fracture or bone pathologies, were excluded. The reference point (R point) was defined as the point where the occlusal plane reached the anterior ramus of the mandible. The position of the IAC in relation to the R point, the buccal bone width (BW), the alveolar crest distance (ACD), the distance from the alveolar crest to the occlusal plane (COD), and the distance from the IAC to the sagittal plane (CS) were determined using proprietary image analysis software which produced cross-sectional coronal and axial images. Results: The distance medially from the R point to the IAC along the axial plane was $6.19{\pm}1.21mm$. The HD from the R point, posteriorly to IAC, in the lateral view was $13.07{\pm}2.45mm$, the VD from the R point was $14.24{\pm}2.41mm$, and the ND from the R point was $10.12{\pm}1.76mm$. The pathway of the IAC was positioned almost in a straight line along a sagittal plane within $0.56{\pm}0.70mm$. The distance from the buccal bone surface to the IAC increased anteriorly from the R point. Conclusion: Marking osteotomy lines in the retromolar area in procedures involving bone harvesting should be discouraged due to the risk of damage to IAC structures. Our measurements indicated that the area from the R point in the ramus of the mandible to 10 mm anterior can be safely harvested for bone grafting purposes.

THE STUDY BY USING THE COMPUTERIZED TOMOGRAPHY IMAGING IN ORDER TO ACCESS TO MANDIBULAR FORAMEN WHILE INFERIOR ALVEOLAR NERVE ANESTHESIA (하치조신경 마취시 하악공으로의 접근을 위한 전산화단층촬영을 통한 방사선적 연구)

  • Kim, Ji-Kwang;Gu, Hong;An, Jin-Suk;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Cho, Jin-Hyoung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.566-574
    • /
    • 2006
  • Purpose : This study was performed to provide an anatomical information of the mandibular ramus for the successful inferior alveolar nerve block. Three dimensional images were reconstructed from the computerized tomography (CT) and the anatomical evaluation of the mandibular ramus was done. Materials and methods : Sixty-four patients who had been taken the facial CT scans from 2000, Jan to 2003, June was selected. The patients who had the anterior or posterior teeth misssing, edentulous ridge, and jaw fracture were excepted. In the occulusal plane, the lingual surface angle (LSA) between the mid-sagittal plane and the mandibular molar lingual surface from the 2nd premolar to the 2nd molar, the inner ramal surface angle (IRSA), the maximum inner ramal surface angle (MxIRSA), and the outer ramal surface angle (ORSA) to the-mid sagittal plane were measured. The inner ramal surface angle in the ligular tip level (IRSA-L) and the outer ramal surface angle in the ligular tip level (ORSA-L), the ramal length (RL), and the anterior ramal length (ARL) were also measured in the lingular tip level. Results : In the lingular tip level, the mean IRSA-L and ORSA-L were $28.6{\pm}6.3^{\circ}$ and $17.9{\pm}4.9^{\circ}$ respectively. The larger was the IRSA, the larger was the ORSA. In the lingular tip level, the mean ramal length was 35.8${\pm}$3.4 mm. The larger was the IRSA-L, the shorter was the ramal length. On the lingular tip level, the mean anterior ramal length from anterior ramus to lingular tip was 19.6${\pm}$3.3 mm. when the ramal length was longer, the anterior ramal length was also longer. On the lingular tip level, there was positive correlation vetween the IRSA and the ORSA, negative correlation between the IRSA and the ramal length, and positive correlation between the ramal length and the lingular tip level to the anterior ramus. There was no statistical meaning of data between sex and age. Conclusion : In the clinical view of the results so far achieved, if the direction of needle is closer to posterior it is able to contact bone on lingular tip when the internal surface of ramus is wided outer.

Open versus closed reduction of mandibular condyle fractures : A systematic review of comparative studies

  • Kim, Jong-Sik;Seo, Hyun-Soo;Kim, Ki-Young;Song, Yun-Jung;Kim, Seon-Ah;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.1
    • /
    • pp.99-107
    • /
    • 2008
  • Objective : The objective of this review was to provide reliable comparative results regarding the effectiveness of any interventions either open or closed that can be used in the management of fractured mandibular condyle Patients and Methods : Research of studies from MEDLINE and Cochrane since 1990 was done. Controlled vocabulary terms were used. MeSH Terms were "Mandibular condyle" AND "Fractures, bone". Only comparative study were considered in this review using the "limit" function. According to the criteria, two review authors independently assessed the abstracts of studies resulting from the searches. The studies were divided according to some criteria, and following were measured: Ramus height, condyle sagittal displacement, condyle Towns's image displacement, Maximum open length, Protrusion & Lateral excursion, TMJ pain, Malocclusion, and TMJ disorder. Results : Many studies were analyzed to review the post-operative result of the two methods of treatment. Ramus height decreased more in when treated by closed reduction as opposed to open reduction. Sagittal condyle displacement was shown to be greater in closed reduction. Condyle Town's image condyle displacement had greater values in closed reduction. Maximum open length showed lower values in closed reduction. In protrusive and lateral movement, closed reduction was less than ORIF. Closed reduction showed greater occurrence of malocclusion than ORIF. However, post-operative pain and discomfort was greater in ORIF. Conclusion : In almost all categories, ORIF showed better results than CRIF. However, the use of the open reduction method should be considered due to the potential surgical morbidity and increased hospitalization time and cost. To these days, Endoscopic surgical techniques for ORIF (EORIF) are now in their infancy with the specific aims of eliminating concern for damage to the facial nerve and of reducing or eliminating facial scars. Before performing any types of treatment, patients must be understood of both of the treatment methods, and the best treatment method should be taken on permission.

AN EXPERIMENTAL STUDY ON THE EFFECT OF THE GALVANIC CURRENT ON THE MANDIBULAR GROWTH IN RAT (Galvani전류가 백서의 하악골 성장에 미치는 영향에 관한 실험적 연구)

  • Yang, Sang-Duk;Suhr, Cheng Hoon
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.189-207
    • /
    • 1988
  • In almost all biologic systems, mechanically induced electric charge separation is a fundamental phenomenon. Since the hypothesis was established that the generation of electric potentials in bone by mechanical stress including muscular force might control the activity in bone by mechanical stress including muscular force might control the activity of osseous cells and their biopolymeric byproduct, the concept of electrically mediate growth mechanism, which involves biological growth and bone remodeling by any means, in living systems has been applied clinically and experimentally to orthopedic fracture repair, the regulation of orthodontic tooth movement, epiphyseal cartilage regeneration, etc. On the other hand, recent numerous research data available show apparently that the mandibular condyle has the characteristics of growth center as well as growth site. In addition, there exists a considerable difference of opinion as to the role of external pterygoid muscle in condylar growth. In view of these evidences, this. experiment was performed to investigate the effect of the galavic current on the growth of the mandible and condyle for elucidating the nature of condylar growth. The bimetallic device was composed of silver and platinum electrode connected with resistor (3.9 Mohm), which was expected to produce galvanic current of 23.6 nA according to the galvanic principle. The 25 Sprague-Dawley rats were divided into two group, 2 week group comprising 8 animals exposed to satanic current for 2 weeks and 3 control animals not exposed for 2 weeks, 4 week group comprising 10 animals in experimental group and 4 animals in control group applied for 4 weeks respectively. The experimental rats were subjected to application of the galvanic current invasively to codylar head surface and the control groups with sham electrode. On the basis of anatomic and histologic data from the mandibular condyle of experimental and control group, the following results were obtained. 1. After 2 weeks, there was no increase of mandibular size in experimental group over that of the control group. 2. After 4 weeks, the size of the condylar head was larger in experimental group than that of the control. 3. In 2 week group, the thickness of the mitotic compartment and hypertrophic chondroblastic layer was increased in experimental group. 4. In 4 week group, the number and the size of the hypertrophic chondroblasts were increased significantly on experimental group over that of the control group. 5. The application of the satanic current caused an increase in chondrocytic hypertrophy and intercellular matrix in both groups.

  • PDF

The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns (다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향)

  • Abukabbos, Layla;Park, Je Uk;Lee, Wonsup
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.135-142
    • /
    • 2022
  • Purpose. This study aims to evaluate the combined effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns. Materials and methods. Seven nickel-chromium dies were generated from a 3D model of mandibular first molar using the digital scanner with the following geometries: 1.5 mm occlusal reduction, 1.0 mm deep chamfer. Based on the abutment model, Zirconia blocks (Luxen Zirconia) were selected to fabricate Sixty-three zirconia crowns with occlusal thicknesses of 0.3 mm, 0.5 mm, and 1.5 mm, and different axial thicknesses of 0.3 mm, 0.5 mm, and 1.0 mm. All crowns were cemented by resin cement. Next, the crowns were subjected to load-to-fracture test until fracture using an electronic universal testing machine. In addition, fracture patterns were observed with a scanning electron microscope (SEM). Two-way ANOVA and the Tuckey HSD test for post hoc analysis were used for statistical analysis (P < .05). Results. The mean values of fracture resistancerecorded was higher than the average biting force in the posterior region. The two-way ANOVA showed that the occlusal and axial thickness affected the fracture resistance significantly (P < .05). However, the effect of axial thickness on fracture resistance did not show a statistical difference when thicker than 0.5 mm. The observed failure modes were partial or complete fracture depending on the severity of crack propagation. Conclusion. Within the limitations of the present study, the CAD-CAM monolithic zirconia crown with extremely reduced thickness showed adequate fracture resistance to withstand occlusal load in molar regions. In addition, both occlusal and axial thickness affected the fracture resistance of the zirconia crown and showed different results as combined.