• 제목/요약/키워드: Mandibular fracture

검색결과 340건 처리시간 0.032초

Postoperative malocclusion after maxillofacial fracture management: a retrospective case study

  • Kim, Sang-Yun;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.27.1-27.8
    • /
    • 2018
  • Purpose: Various complications occur when a maxillofacial fracture is malunionized or improperly resolved. Malocclusion is the most common complication, followed by facial deformity, temporomandibular joint disorder (TMD), and neurological symptoms. The purpose of this study was to evaluate the dental treatment of postoperative complications after maxillofacial fracture. Materials and methods: In this study, nine patients with a postoperative complication after maxillofacial fracture who had been performed the initial operation from other units and were referred to the authors' department had been included. Of the nine patients, six had mandibular fractures, one had maxillary fractures, one had maxillary and mandibular complex fractures, and one had multiple facial fractures. All the patients had tooth fractures, dislocations, displacements, and alveolar bone fractures at the time of trauma, but complications occurred because none of the patients underwent preoperative and postoperative dental treatment. Malocclusion and TMD are the most common complications, followed by dental problems (pulp necrosis, tooth extrusion, osteomyelitis, etc.) due to improper treatment of teeth and alveolar bone injuries. The patients were referred to the department of dentistry to undergo treatment for the complications. One of the nine patients underwent orthognathic surgery for a severe open bite. Another patient underwent bone reconstruction using an iliac bone graft and vestibuloplasty with extensive bone loss. The other patients, who complained of moderate occlusal abnormalities and TMDs such as mouth-opening limitation, underwent occlusal treatment by prosthodontic repair and temporomandibular joint treatment instead of surgery. Results: One patient who underwent orthognathic surgery had complete loss of open bite and TMD after surgery. One patient who underwent reconstruction using an iliac bone graft had a good healing process. Other patients were treated with splint, injection, and physical therapy for mouth-opening limitation and temporomandibular joint pain. After treatment, the TMDs were resolved, but the remaining occlusal abnormalities were resolved with prosthetic restoration. Conclusions: Considering the severity of malocclusion and TMJ symptom and the feasibillity of reoperation, nonsurgical methods such as orthodontic and prosthodontic treatments and splint therapy can be used to manage the dental and TMD complication after the trauma surgery. However, reoperation needs to be strongly considered for severe malocclusion and TMD problem.

섬유강화 포스트와 금속주조 포스트의 파절강도 밋 파절양상의 비교 (COMPARISON OF FRACTURE STRENGTH AND PATTERN OF ENDODONTICALLY TREATED TEETH RESTORED WITH FIBER POSTS AND METAL CAST POST)

  • 김미경;김석규
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.535-543
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the effect of two fiber post systems and one metal cast post system on the fracture strength and fracture pattern of crowned, endodontically treated teeth with 2 mm-height of the reamining tooth structure. Materials and methods: A total of 36 recently extracted sound human mandibular premolars were selected Each tooth structure of the crown portion except 2mm-height of the one above the cementoenamel junction was removed. After being endodontically treated, they were randomly distributed into 3 groups: group 1, restored with quarts fiber post(D.T. Light-Post), group 2, with glass fiber post(FRC Postec), and group 3, metal cast post and core. All teeth were fully covered with nonprecious metal crowns. Each specimen was embedded in an acrylic resin block and then secured in a universal load-testing machine. A compressive load was applied at a 130 degree angle to the long axis of the tooth until fractured, at a crosshead speed 20mm/min. The highest fracture loads were measured and recorded as the fracture strength of each specimen. Fracture areas were measured on the mid-buccal and mid-lingual point from the crown margins. One-way analysis of variance and Turkey test were used to determine the statistic significance of the different fracture loads and areas among the groups (p<0.05). Results: The mean fracture loads were $1391{\pm}$425N(group 1), $1458{\pm}476N$(group 2) and $1301{\pm}319N$(group 3). The fracture loads among the three groups had no statistically signifiant difference (p>.05). The mean fracture area of the fiber post was closer to the crown margin than that of the metal cast post and core(p<.05). The metal cast post showed unrestorable and catastrophic fracture patterns. Conclusion: Within the limitations of this study, fracture loads with any statistically significant difference were not recorded for endodontically treated teeth restored with two fiber posts and the metal cast post. But teeth restored with the fiber posts typically showed the fracture pattern close to the crown margin, which was almost restorable.

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

  • Elshiyab, Shareen H;Nawafleh, Noor;Ochsner, Andreas;George, Roy
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.65-72
    • /
    • 2018
  • PURPOSE. The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS. Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between $5^{\circ}C$ and $55^{\circ}C$. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS. All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION. When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.

Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions

  • Choi, Sulki;Yoon, Hyung-In;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.423-431
    • /
    • 2017
  • PURPOSE. The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS. Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS. The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION. The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness.

Influence of modification in core building procedure on fracture strength and failure patterns of premolars restored with fiber post and composite core

  • Kim, Young-Hoi;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.37-42
    • /
    • 2012
  • PURPOSE. The influence of the modified process in the fiber-reinforced post and resin core foundation treatment on the fracture resistance and failure pattern of premolar was tested in this study. MATERIALS AND METHODS. Thirty-six human mandibular premolars were divided into 4 groups (n = 9). In group DCT, the quartz fibre post (D.T. Light-post) was cemented with resin cement (DUO-LINK) and a core foundation was formed with composite resin (LIGHT-CORE). In group DMO and DMT, resin cement (DUO-LINK) was used for post (D.T. Lightpost) cementation and core foundation; in group DMO, these procedures were performed simultaneously in one step, while DMT group was accomplished in separated two steps. In group LCT, the glass fiber post (LuxaPost) cementation and core foundation was accomplished with composite resin (LuxaCore-Dual) in separated procedures. Tooth were prepared with 2 mm ferrule and restored with nickel-chromium crowns. A static loading test was carried out and loads were applied to the buccal surface of the buccal cusp at a 45 degree inclination to the long axis of the tooth until failure occurred. The data were analyzed with MANOVA (${\alpha}$= .05). The failure pattern was observed and classified as either favorable (allowing repair) or unfavorable (not allowing repair). RESULTS. The mean fracture strength was highest in group DCT followed in descending order by groups DMO, DMT, and LCT. However, there were no significant differences in fracture strength between the groups. A higher prevalence of favorable fractures was detected in group DMT but there were no significant differences between the groups. CONCLUSION. The change of post or core foundation method does not appear to influence the fracture strength and failure patterns.

안면골 골절 후 시신경 손상에 관한 고찰 (THE CLINICAL STUDY OF THE OPTIC NERVE INJURY AFTER FACIAL TRAUMA)

  • 박재억;윤경인
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권6호
    • /
    • pp.677-680
    • /
    • 2000
  • Orbital injuries are common with facial trauma. Direct injuries to the globe are not rare but it can result in complications such as chemosis, subconjunctival hemorrhage and hyphema. Periorbital trauma or injuries to the extraocular muscles and blow-out fracture may result in lid edema, ecchymosis & ptosis and diplopia or limitation of ocular motion respectively. Indirect injuries to the optic nerve come up without any injuries but its complication is irreversible and severe such as loss of vision. The aim of this study is to review the literature on blindness or ptosis following facial trauma and present the cases of blindness after facial trauma and ptosis after mandibular fracture without specific clinical findings.

  • PDF

하악 우각부 미용 성형술 ; 임상적 응용과 병발증 (ESTHETIC MANDIBULAR ANGLE REDUCTION ; IST USE AND COMPLICATIONS)

  • 김창수;엄인웅;민병국;민성기;양윤석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제13권2호
    • /
    • pp.137-143
    • /
    • 1991
  • 악안면부의 기형은 기능 및 심미적인 매우 중요한 문제이며, 이러한 면에서 현대 악안면 영역의 성형술은 기능 및 사회심리적으로 많은 기여를 한다는 것은 사실이다. 악안면 성형술 중 하악 우각부에 대한 관심은 19 세기 후반부터 교근비대증 (Masseter Hypertrophy)으로 표현되었으며, 안모의 심미적인 영향에 대한 평가는 동양에서 하악골의 변형과 함께 비중있게 다루어지고 있다. 교근비대 또는 협부비대의 원인은 악성 및 양성종물, 악습관에 의한 생리적 비대, 감염, 선천적기형 등이 있을 수 있으나, 환자가 호소하는 주소는 안연의 비대칭 또는 사각형의 안모등이므로 이에 대한 수술의 주된 목적은 심미적인 면이 대부분을 차지한다고 볼 수 있다. 그러므로 안모개선 등 수술 후의 결과에 대한 깊은 관심이 요구되며, 따라서 혈종이나 감염, 하악골 골절, 개구장애 등과 같은 합병증과 후유증에 대한 올바른 이해와 최대한의 예방이 필요할 것으로 사료되어 문헌고찰과 함께 증례보고를 하는 바이다.

  • PDF

Comparison of intermaxillary fixation techniques for mandibular fractures with focus on patient experience

  • Kim, Young Geun;Yoon, Sung Ho;Oh, Jae Wook;Kim, Dae Hwan;Lee, Keun Cheol
    • 대한두개안면성형외과학회지
    • /
    • 제23권1호
    • /
    • pp.23-28
    • /
    • 2022
  • Background: Intermaxillary fixation (IMF) is a technique that allows for the reduction and stabilization of mandibular fractures. Several methods of IMF, such as self-tapping screws or arch bars, have been developed. This study aimed to validate the usefulness of IMF with a self-tapping screw compared to IMF with arch bars with focus on the patients' perspective. Methods: We retrospectively reviewed the medical records of all patients who were treated for mandibular fractures at our hospital between August 2014 and February 2021. A total of 57 patients were enrolled in this study. Thirteen patients were excluded from the analysis: three patients were lost to follow-up, and 10 patients did not undergo IMF. Finally, 44 patients were analyzed, of which 31 belonged to the arch bar group, and 13 belonged to the screw group. Patient discomfort and pain during IMF application and removal were analyzed using a patient self-assessment questionnaire. The surgeon also assessed oral hygiene, IMF stability, and occlusion. Results: We applied IMF to 34 men (77%) and 10 women (23%). The mean age of the patients was 37.3 years. The most common fracture site was the angle (30%), followed by the parasymphysis (25%), the body (23%), the condyle (11%), and the ramus (11%). Patient discomfort and oral hygiene were statistically favorable in the screw group. The IMF application time was statistically shorter in the screw group (p< 0.001). IMF stability was not statistically different between the two groups. The pain score during IMF removal was lower in the screw group (p< 0.001). Conclusion: Compared to arch bars, IMF screws provide more comfort during the IMF period, help maintain favorable oral hygiene, and have a shorter application time. From the patient's perspective, IMF screws are an excellent alternative to conventional arch bars when applicable.

생흡수성판을 이용한 하악골 골절의 치료 : 일차보고 (TREATMENT OF MANDIBLE FRACTURES USING BIOABSORBABLE PLATES: PRELIMINARY STUDY)

  • 김영균;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권6호
    • /
    • pp.570-575
    • /
    • 2001
  • This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Thirty-four fractures of the mandible in 27 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pre-tapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 5.3 days. Patients were evaluated for complications during the follow-up period, which ranged from 2 to 18 months. Five patients(18.5%) experienced complications. These included infection (four patients), and premature occlusal contact(one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures with the advantage that they do not need to be removed.

  • PDF