• Title/Summary/Keyword: Mandible fracture

Search Result 223, Processing Time 0.028 seconds

Osteotomy and iliac bone graft for the treatment of malunion caused by failed mandibular fracture reduction

  • Hwang, Kun;Ma, Sung Hwan
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.6
    • /
    • pp.384-386
    • /
    • 2020
  • This report describes osteotomy and iliac bone graft for malunion caused by failed mandibular fracture reduction. A 27-year-old man was referred 3 months after a motor vehicle accident. At another hospital, two operations had been performed for symphyseal fracture using two resorbable plates. Malocclusion was noted, and panoramic radiography and computed tomography revealed a misaligned dental arch, with a 9.37-mm gap between the central and the lateral incisor of the left mandible. A wafer was made from the patient's dental model, and a maxillary arch bar was applied. Through a lower gingivolabial incision, osteotomy was performed between the malunited symphyseal fracture segments. Both segments were reduced to their original position using the wafer and fixed with titanium miniplates via intermaxillary fixation (IMF). The intersegmental gap was filled with cancellous bone from the iliac crest. The gingival defect was covered with a mucosal transposition flap from the gingivolabial sulcus. IMF and the wafer were maintained for 5 and 9 weeks, respectively. At postoperative week 13, the screws were removed from the mandible and satisfactory occlusion was noted. His mouth opening improved from 2.5 to 3 finger breadths (40 mm). This case demonstrates the need for sufficient IMF when using resorbable plates.

Retrospective clinical study of mandible fractures

  • Jung, Hai-Won;Lee, Baek-Soo;Kwon, Yong-Dae;Choi, Byung-Jun;Lee, Jung-Woo;Lee, Hyun-Woo;Moon, Chang-Sig;Ohe, Joo-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • Objectives: The purpose of this article is to analyze the incidence, demographic distribution, type, and etiology of mandible fractures that were treated by the Department of Oral and Maxillofacial Surgery in Kyung Hee University Dental Hospital from January 2002 to December 2012. Materials and Methods: This was a descriptive and analytic retrospective study that evaluated 735 patients that were treated for mandible fracture. Results: This study included 1,172 fractures in 735 patients. The ratio of male to female patients was 5.45 : 1; the maximum value was in patients between 20 and 29 years (38.1%) and the minimum in patients over 70 years old. The monthly distribution of facial fractures peaked in the fall and was lower during winter. No specific correlation was identified based on the annual fracture distribution. Among the 735 fracture patients, 1.59 fracture lines were observed per patient. The most frequent site was the symphysis, which accounted for a total of 431 fractures, followed by the angle (348), condyle (279), and body (95). The symphysis with angle was the most common site identified in combination with fracture and accounted for 22.4%, followed by symphysis with condyle (19.8%). The angle was the most frequent site of single fractures (20.8%). The major cause of injury was accidental trauma (43.4%), which was followed by other causes such as violence (33.9%), sports-related accidents (10.5%), and traffic accidents (10.1%). Fracture incidents correlated with alcohol consumption were reported between 10.0%-26.9% annually. Conclusion: Although mandible fracture pattern is similar to the previous researches, there is some changes in the etiologic factors.

Panfacial bone fracture: cephalic to caudal

  • Yun, Seonsik;Na, Youngcheon
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.1
    • /
    • pp.1-2
    • /
    • 2018
  • Theoretically, panfacial bone fractures involve all three areas of the face: frontal bone, midface, and mandible. In practice, when two out of these three areas are involved, the term "panfacial bone fracture" has been applied. We can use physical examination, simple radiologic examination, and computed tomography study for diagnosis. Linear fracture are treated by conservative treatment. But, most of panfacial bone fracture patients need to be treated by open reduction and internal fixation. Facial width is most important thing that we need to care during operation. There are many ways about sequence like "top to bottom," "bottom to top," "outside to inside," or "inside to outside" and the authors prefer "top to bottom" and "outside to inside" ways. The authors apply arch bar from the first of surgery and then, set frontal bone fracture, midface fracture and mandible fracture in sequence. Usually, we remove the stitches for 5 days after surgery and the intraoral stitch removed after 2 weeks. Usually arch bar is going to be removed 4 weeks after surgery. We could get acceptable results with the above way.

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.

FINITE ELEMENT ANALYSIS OF RECONSTRUCTION OF MANDIBULAR SYMPHYSIS DEFECTS USING RECONSTRUCTION PLATES (유한 요소법을 이용한 하악골 이부 결손수복에 사용된 재건용 금속판의 응력분포에 관한 연구)

  • Oh, Jung-Hwan;Han, Jung-Soo;Min, Jee-Hyun;Mun, Sung-Jun;Lee, Baek-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.513-517
    • /
    • 2008
  • Purpose: This study aimed to evaluate distribution and maximal value of mechanical stresses on the reconstruction plate, bridging mandibular symphysis defect, and to optimize the most appropriate locations of the plate to distribute the stress causing the fracture of the plate. Materials and methods: Four types of reconstruction were constructed by different number and location of the reconstruction plates on the 3 D finite element model (FEM) of a human edentulous mandible; Type I: one plate on the inferior border of the anterior mandible, Type II: one plate on the middle of the anterior mandible, Type III: one plate on the superior border of the anterior mandible, and Type IV: two plates on the inferior and superior border of the anterior mandible. Results: The results showed that the maximal stress of type I (234.29 Mpa) was lower than that of type II (260.91 Mpa) and type III (247.37 Mpa), but higher than that of type IV (186.64 Mpa). We could also observe that the stresses are tending to focus on the inner side and inferior part of the plate which connected proximal segment from the vertical load. Conclusions: On the basis of the findings, it was concluded that using a plate on the inferior border of mandible or two plates on the inferior and superior border of mandible are more favorable to distribute mechanical stresses, which could reduce the fracture of the plate.

A RETROSPECTIVE CLINICAL STUDY OF CONDYLAR FRACTURES OF THE MANDIBLE IN A 4-YEAR PERIOD (하악 과두 골절에 대한 4년간의 후향적 임상연구)

  • Ryu, Jae-Young;Kim, Hyun-Syeob;Park, Chung-Youl;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.388-397
    • /
    • 2008
  • The present study was performed to evaluate the function of the mandible according to the pattern of fracture and treatment methods of condylar fractures of the mandible and help operators in making a treatment plan. Sixty patients (average follow-up period was $7.8{\pm}9.4$ months) who were treated for condylar fracture from June, 2002 to May, 2006 at the Department of Oral and Maxillofacial surgery, Chonnam National University Hospital were reviewed. The common causes of the condylar fracture were traffic accident and fall-down (35.0%). In concomitant injuries, laceration was 46.7% and the fracture of the mandibular symphysis was highest incidence (60.0%). The common site of the fracture was the condylar head (47.8%), followed by subcondyle (36.2%) and condylar neck (15.9%). Under 15 years old patients, the closed reduction was performed in 87.5% out of the patients. All of the condylar fragments were fixed to the mandible with titanium miniplates in cases of open reduction. The mean period of intermaxillary fixation (IMF) was $14.2{\pm}6.5$ days in closed reduction and $10.0{\pm}4.2$ days in open reduction. The old patient with bilateral condylar head fractures, who were treated by closed reduction with IMF for 3 weeks, showed the limitation of mandibular movements. But, there was no significant different results between open reduction and closed reduction with the respect of the Helkimo's mandibular mobility index and clinical dysfunction index (DI). Complications, such as fibrous ankylosis and resorption of the mandibular condyle, were not observed in all patients. These results suggest that the good results can be obtained by closed reduction with proper IMF periods and functional exercise in most condylar fractures of the mandible except severely displaced extracapsular fractures.

The Result of Mandible Fracture Fixations with Biodegradable Materials (생체흡수성 재료를 이용한 하악골절 치료의 결과)

  • Wang, Jae Kwon;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: Traditionally, titanium miniplate has been used for rigid fixation of mandible fractures. However, the limitations of metal plate have been reported such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy, and so forth. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite of its lower strength. This study evaluated the usefulness and stability of biodegradable plate and screw for treatment of mandible fractures. Methods: In this study, 61 patients(92 areas) diagnosed as mandible fracture in the last 2 years have been reviewed. We used titanium plate and screw in 32 patients, and biodegradable plate and screw($INION^{(R)}$) in 29 patients. Stability of plates and screws, bony healing process and its side effects were observed by clinical and radiographic assessment. Results: In the titanium material group, one of malocclusion, two of mouth opening limitation, three of pain, three of palpation were shown. The plate of six patients involved in these complications were removed. In the biodegradable group, two of mouth opening limitation, two of pain, one of localized wound infection were shown and one plate was removed secondarily. Conclusion: There was no statistical difference between two groups in bony healing and complication rates. Biodegradable implants show efficient stability during initial bone healing and low side effects in long-term follow up periods.

Traumatic Internal Maxillary Artery Pseudoaneurysm Caused by Fracture of the Mandible Ramus: A Case Report (턱뼈가지의 골절로 인한 내상악동맥의 가성동맥류 1례)

  • Han, Chang Dok;Kim, Young Hyo;Kim, Kyu-Sung;Choi, Hoseok
    • Journal of Trauma and Injury
    • /
    • v.25 no.1
    • /
    • pp.32-35
    • /
    • 2012
  • Traumatic pseudoaneurysms in the head and neck region are very rare. Particularyly, pseudoaneurysms of the internal maxillary artery are known to be very rare. The authors report a 20-year old male who was diagnosed as having a pseudoaneurysm of the internal maxillary artery. The cause was assumed to be a mandible ramus fracture. When he visited our emergency room, we did not consider a pseudoaneurysm because of his other life-threatening conditions. Fortunately, he re-visited our hosipital before the aneurysm ruptured. He was diagnosed with angiography and was treated by using embolization with glue. The rupture of the pseudoaneurysm could have caused a life-threatening hemorrhage.

Facial Bone Fracture Patients Visiting Pusan National University Hospital in Busan and Yangsan: Trends and Risks

  • Kim, Hyo-Geon;Son, Yong-Hyun;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.140-145
    • /
    • 2014
  • Purpose: This study examined patients with facial bone fracture visiting Pusan National University Dental Hospital to understand the trends, and to enhance appropriate care and treatment for patients with facial bone fracture. Methods: We investigated 531 patients presenting with facial bone fracture in Yangsan and 802 patients in Busan from January 2010 to December 2013. We divided the patients by year, month, gender, age, site, and cause to compare with historic data and other studies. Results: The gender ratio was 3.58:1 in Yangsan and 4.31:1 in Busan. Patients aged in their 20s had the highest number of facial bone fractures in both Yangsan and Busan. The most frequent fracture site was the mandible, and the most frequent cause was slip down in both Yangsan and Busan. Conclusion: The investigation and comparison of patients with facial bone fracture who visited Pusan National University Hospital located at Yangsan and Busan from 2010 to 2013 found a difference in the total number of patients at each hospital, but the trends were not significantly different.

Study on the Fracture of the Condyle Head (하악두 골절에 관한 연구 II)

  • Kim, Soo-Kyung
    • The Journal of the Korean dental association
    • /
    • v.23 no.12 s.199
    • /
    • pp.1027-1030
    • /
    • 1985
  • Student male 16 years old fractures of mandible in symphysis and both condyle head, conservative treated intermaxillary wiring (Rubber bands elastic) 2 weeks, mandible movement fractured healed. Patient has practically normal masticatory function and no complaints after treated 10 months.

  • PDF