• Title/Summary/Keyword: Management Monitoring Standards

Search Result 180, Processing Time 0.03 seconds

Application of Risk Management Standards for Product Safety Management Program (리스크 관리규격의 제품안전경영프로그램에 대한 적용)

  • 이동하;나윤균;김명수
    • Journal of Applied Reliability
    • /
    • v.1 no.2
    • /
    • pp.109-120
    • /
    • 2001
  • This study reviewed the national standards for risk management to judge whether they are suitable for a product safety management program. Among the standards issued from Australia, New Zealand, Canada, Japan, and UK, the risk management guideline (AS/NZS 4360: 2000) issued jointly from both Australia and New Zealand have better features for product safety management program than any other risk management standards in view point of broad definition of risk concept including opportunities of loss and gain, stepwise composition of management processes applicable iteratively, and integrable form of structure addible to existing management practice. Comparing the three product safety management programs suggested by several authors yielded common features of product safety management program model: (1) organization for product safety, (2) risk identification, (3) risk evaluation, (4) risk treatment, (5) monitoring/communication, and (6) documentation. All of these activities can be performed within risk management framework proposed by AS/NZS 4360.

  • PDF

Power Quality Monitoring System Using DWB on Distribution Automation System (DWB를 이용한 배전자동화 기반의 전기품질 모니터링 시스템 구축)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.86-93
    • /
    • 2011
  • The necessity of Power Quality(PQ) Management grow bigger because the disturbance strength in power system is increasing, on the other hand, the tolerance of electrical components is reducing with widely use of the IT and digital equipments. The domestic management standards on power quality are enacted based on the IEC standards in recent. Since the IEC standards defines the measurement and evaluation point on PQ as PCC(Point of Common Coupling) which is normally the point of penetration between customer and power company, the PQ monitoring system(PQMS) should be made to measure and manage the PQ of custom effectively. In this paper, therefore, the economical construction plan on PQMS using the wireless communication channel in distribution automation system is suggested, and the usefulness of the PQMS are shown by analyzing the PQM data with IEC standards.

Establishment of Maintenance and Monitoring Standards for Shield and TBM Tunnels (Shield 및 TBM 터널의 유지관리계측 관리기준 설정에 관한 연구)

  • Jong-Tae Woo
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 2024
  • Purpose: The objective of this study was to improve the tunnel maintenance and monitoring technology by establishing the maintenance, management, and monitoring standards for shield and TBM tunnels, which had been applied more in recent years. Method: This study comprehensively analyzed and compared the data and model simulations of Seoul Subway Lines 7 and 9 and Bundang Line, shield and TBM tunnels in South Korea, tunnels in France and Japan, and Channel Tunnel in the UK. Result: This study set maintenance and monitoring standards when there was no design estimate based on numerical analyses such as section design and section analysis regarding the maintenance and monitoring section of shield and TBM tunnels. Conclusion: It is necessary to determine safety by comprehensively considering not only each monitoring item but also the changing trend and correlation of all items and compensation of the tunnel.

Risk Management Standards As a Product Safety Management Program (제품안전경영프로그램으로서의 리스크 관리규격)

  • 이동하
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.376-383
    • /
    • 2001
  • This study reviewed the national standards for risk management to judge whether they are suitable for a product safety management program. Among the standards issued from Australia, New Zealand, Canada, Japan, and UK, the risk management guideline (AS/NZS 4360: 2000) issued jointly from both Australia and New Zealand have better features of product safety management program such as a broad definition of risk concept including opportunities of loss and gain, stepwise composition of processes applicable iteratively, and integrable composition of processes for the existing other management practice. Comparing the three product safety management programs suggested by several authors yielded common features of product safety management program model: (1) organization for product safety, (2) risk identification, (3) risk evaluation, (4) risk treatment, (5) monitoring/communication, and (6) documentation. All of these activities can be performed within risk management framework.

  • PDF

Problems and Improvements in the Quality Control of the Air Monitoring Network (대기오염측정망 정도관리의 문제점과 개선방향)

  • Kim, Duck-Sung;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

IEC 61968/61970 based Distribution Management System Suggestion (IEC 61968과 61970 기반의 배전운영 시스템 제안)

  • Kim, Taw-Wan;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Kwon, Sung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.231-238
    • /
    • 2011
  • A role of Distribution Automation System(DAS) is required to be changed from observing and control to complex and various new system including functions which monitoring, control, prediction, operation and management of EMS type according to be gradually Smart Grid of distribution operation system for development of further power system industrial. IEC(International Electrotechnical Commission) published communication standards which interface and data model of distribution operation system to IEC 61968 and of host system like EMS(Energy Management System) to IEC 61970. So far, each standards are emphasizing themselves, but if they are applied by designed integration of the standards, it could be more efficiency system. So, in this paper, integration application of IEC standards and structure of further distribution operation system to use them are proposed by gradually increasing importance of communication protocols, functions and roles in further distribution management system considering Smart Grid.

Industry's Response to the Green Movement

  • Little, Barry F.P.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.1075-1078
    • /
    • 1995
  • This paper describes how industry has responded to the environmental challenge. Benefits include compliance with environmental legislation; genuine reductions to environmental impact; sustainable improvements to profitability in the face of increased competitive pressure. National and international Standards for environmental management offer security and direction for a company wishing to improve environmental performance and coupled with a waste minimisation strategy many financial and environmental benefits can be achieved. Introduction of new technical skills, techniques and worker understanding to aid motivation is an essential component of such a strategy. Monitoring and targeting has a key role to play in the establishment of improved environmental performance.

  • PDF

Hygiene Monitoring of Food for Children's Foodservice Using the IoT-based Smart Food Safety Management System (iMEAL) (사물인터넷(IoT) 기반 스마트 급식안전관리시스템(iMEAL) 개발 및 이를 적용한 어린이 급식소용 음식의 위생모니터링)

  • Eun-Jin Lee;Sang-Hyeok Seo;Hye-Kyung Moon
    • Journal of the Korean Dietetic Association
    • /
    • v.30 no.1
    • /
    • pp.61-73
    • /
    • 2024
  • This report was prepared to introduce the developed Internet of Things (IoT)-based Smart Food Safety Management System (iMEAL) for children's foodservices registered in the Center for Children's Foodservice Management and report the results of hygiene monitoring through microbial analysis of two foods simulated and distributed based on this system. The program consisted of three menu screens: a foodservice management and meal inspection function, a refrigerator/freezer monitoring function, and a sanitary/safety inspection log function. Data such as cooking temperature, refrigerator and freezer temperature, salinity, and chlorine concentration were collected using IoT sensors or terminals, and hygiene safety inspection diary results (recorded by cooks) were transmitted to the Internet and stored. The APCs (3.78±0.07 log CFU/g) and E. coli (not detected) in stir-fried pork teriyaki sauce and the heating process met cooking standards. Similarly, the APCs (4.05±0.05 log CFU/g) and E. coli (not detected) in cucumber/chomuchim, which was not heated, also met cooking standards. APCs increased over time when cooked food was left for 1 hour, 1.5 hours, or 2 hours but remained acceptedable. Based on hygiene monitoring results of these two foods, using the i-MEAL system resulted in the safe production and distribution of children's food.

Tritium( $^3$H) Activity Measurement by the Liquid Scintillation Counting Method

  • Hwang, Sun-Tae;Oh, Pil-Jae;Lee, Min-Kie;Kim, Wi-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.299-302
    • /
    • 1994
  • At a nuclear power plant, environmental radioactivity monitoring is routine work for the radiation safety management For the environmental monitoring of tritium($^3$H) activity in water sampled liquid scintillation counting( LSC) method is applied to measure low- energy beta activity from tritium in the samples. The $^3$H activity is measured using the BECKMAN 5801 system at the KRISS( Korea Research Institute of Standards and Science) for evaluating the lower limits of detection( LLD) of $^3$H measurement and the measuring capability of low-level $^3$H activity at four nuclear Power Plant sites. The LSC systems used for low-level $^3$H activity measurements at the nuclear Power Plants are confirmed to satisfy throughout an intercomparison study under the experimental arrangements by the KRISS.

  • PDF

Development of a Strategy and Guideline for Adopting Business Process Management Standards (BPM 표준의 도입 전략 및 활용 가이드라인의 개발)

  • Kim, Min-Soo;Lim, Tae-Soo;Kim, Dong-Soo
    • The Journal of Society for e-Business Studies
    • /
    • v.12 no.2
    • /
    • pp.249-267
    • /
    • 2007
  • A variety of BPM (Business Process Management) standards to achieve interoperability among heterogeneous systems have been released. Areas of BPM standards include business process modeling, process execution and management, and monitoring and controlling. The purpose of this research is to develop an adoption strategy and guideline for implementing BPM standards. We suggest a strategy for implementing BPMN (Business Process Modeling Notation), BPEL (Business Process Execution Language), and BPQL (Business Process Query Language) and provide a specific implementation guideline for developing BPM solutions using each standard. We expect that BPM vendors can establish their own strategy for adopting BPM standards and implement BPM solutions efficiently and effectively with the help of the strategy and guideline described in this paper.

  • PDF