• Title/Summary/Keyword: Malfunction Analysis

Search Result 255, Processing Time 0.032 seconds

Analysis for Fault and Malfunction of the Elevator for the Passenger (승객용 승강기 고장 및 오동작 사례 분석)

  • Kim, Gi-Hyun;Bang, Sen-Bae;Kim, Chong-Min;Hwang, Kwang-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.327-331
    • /
    • 2005
  • This paper gives the information for fault and malfunction of the Elevator for the passenger. For analyzing the fault and malfunction of the elevator equipment we research the report of fault and malfunction which is written by ATP electric director and Elevator maintenance company during recently one year. We analyze the number of fault and malfunction according to classified by month, season, time and classify the kind of fault and malfunction such as stop, fault of door, malfunction of floor indication and so on. And now we research fault and malfunction for the power quality such as Sag, Swell, Interruption, Harmonic, electric voltage rise and so on at elevator equipments and are testing Elevator imitation equipment.

  • PDF

The analysis for malfunction of elevator equipment by instantaneous power quality (순시전원품질 변화에 딱른 엘리베이터의 오동작에 관한 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Yi, Geon-Ho;Kim, Sun-Gu;Yoon, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.34-36
    • /
    • 2006
  • The number of confine-disease of elevator increases every year and then sudden rise, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. For confirmation those malfunction accident, we are measuring and analyzing power quality(Sag, Interruption, Harmonic) of the actual site and evaluated the performance for stop and stating by testing the two imitation test equipment with EN12016(2004) standard level. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

  • PDF

A Study on Wafer to Wafer Malfunction Detection using End Point Detection(EPD) Signal (EPD 신호궤적을 이용한 개별 웨이퍼간 이상검출에 관한 연구)

  • 이석주;차상엽;최순혁;고택범;우광방
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.506-516
    • /
    • 1998
  • In this paper, an algorithm is proposed to detect the malfunction of plasma-etching characteristics using EPD signal trajectories. EPD signal trajectories offer many information on plasma-etching process state, so they must be considered as the most important data sets to predict the wafer states in plasma-etching process. A recent work has shown that EPD signal trajectories were successfully incorporated into process modeling through critical parameter extraction, but this method consumes much effort and time. So Principal component analysis(PCA) can be applied. PCA is the linear transformation algorithm which converts correlated high-dimensional data sets to uncorrelated low-dimensional data sets. Based on this reason neural network model can improve its performance and convergence speed when it uses the features which are extracted from raw EPD signals by PCA. Wafer-state variables, Critical Dimension(CD) and uniformity can be estimated by simulation using neural network model into which EPD signals are incorporated. After CD and uniformity values are predicted, proposed algorithm determines whether malfunction values are produced or not. If malfunction values arise, the etching process is stopped immediately. As a result, through simulation, we can keep the abnormal state of etching process from propagating into the next run. All the procedures of this algorithm can be performed on-line, i.e. wafer to wafer.

  • PDF

Malfunction Measures and Susceptibility test of Elevator Based on EMS(Electromagnetic Susceptibility) Standard (EMS 규정에 따른 승강기 내성시험 및 오동작 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Lee, Joo-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.78-85
    • /
    • 2007
  • The malfunction accidents such as kept within elevator, sudden rise, sudden stop, error of level indication which can bring about uneasiness of elevator passenger and be related with life accident are occurring. However, as there is not field recurrence for this portion and they are accidents that occur and then disappear, it is actually difficult to confirm the reason of accident. Therefore, we made an experiment for tolerance in three models which is being built recently according to EN12016(2004) standard and analyzed the movement characteristics of elevator to study the reason which can bring about confine and malfunction. Furthermore after supplementing measures for malfunction, Finally this paper will be used as reference to suggest methods for malfunction of elevator facility and the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

The Cause Analysis and Research of Malfunction for Elevator Equipment of the Apartment House (공동주택의 승강기 설비에 대한 오동작 원인 조사 및 고찰)

  • Kim, Gi-Hyun;Bang, Sun-Bae;Kim, Chong-Min;Bae, Suk-Myong;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.65-71
    • /
    • 2006
  • The number of elevator installation increases every year about 15,000. The number of confine-disease of elevator increases every year and then sudden in, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction related life accident is increasing. Therefore we researched elevator repair diary of elevator repairing company, APT management office and 119 life rescue for elevator confine-disease during 2004. 1. 1.${\sim}$12. 31. we analyzed the content and the time type and cause of the malfunction and fault for APT elevator. Form the result of 119 life rescue, only power reset is 24[%] and only power failure is 8.2[%] by cause of confine-disease. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

Analysis of Malfunction Characteristics of High Sensitivity Type Earth Leakage Circuit Breaker for 30[A] due to Lightning Impulse Voltages (뇌임펄스전압에 대한 30[A]용 고감도형 누전 차단기의 오동작에 대한 특성의 해석)

  • 이복희;이승칠;김찬오
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.96-103
    • /
    • 1997
  • This paper deals with the malfunction characteristics of the earth leakage circuit breakers(ELBs) applied by a lightning impulse voltage. In the cases of the regulation of KS C 4613 and the simulated circuits with surge protection devices, the dead operation characteristics of the ELBs against lightning impulse voltages were experimentally investigated and discussed. As a result, all the specimens(ELBs) used in this work have a cutoff performance of the lightning impulse voltage when the differential mode surges were injected at the input terminals of the ELBs owing to a surge absorber installed at the power source side of amplification circuit. Four kinds of the specimens have brought about malfunction in the condition of the lightning impulse dead operation test defined in KS C 4613, and the malfunction voltages are relatively high and are about 5-6.5[kV]. In the case of the simulated test circuit with surge protection devicesthree kinds of the ELBs have led to malfunction. Also the voltage level causing the malfunction of the ELBs is decreased by operation of surge protection devices, and it ranges from 3 to 5(kV).

  • PDF

A Malfunction Pattern Distinction of an Automotive Electric part by Sound and Vibration Frequency Analysis (소음진동 주파수분석을 이용한 자동차 전동부품의 고장유형 분석)

  • Sim, Han-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.107-112
    • /
    • 2021
  • The usage of electric-powered components consisting of several electrical and mechanical parts is continuously increasing in automobiles. Therefore, continuous assessment of the reliability and quality of these electric-powered parts is crucial. In this study, a noise and vibration measurement system for testing and evaluating the different electric-powered parts of automobiles was designed. Further, an FFT analysis was performed on some electric-powered steering assembly test equipment. In the FFT analysis of the noise and vibration signals for each essential fault part, the vibration FFT analysis was significantly compared with the noise analysis. The results showed that the vibration FFT analysis was more effective in determining the reliability and quality of the electric-powered parts.

Vulnerability Analysis of Network Communication Device by Intentional Electromagnetic Interference Radiation (IEMI 복사에 의한 네트워크 통신 장비의 취약성 분석)

  • Seo, Chang-Su;Huh, Chang-Su;Lee, Sung-Woo;Jin, In-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • This study analyzed the Vulnerability of Network Communication devices when IEMI is coupled with the Network System. An Ultra Wide Band Generator (180 kV, 700 MHz) was used as the IEMI source. The EUTs are the Switch Hub and Workstation, which are used to configure the network system. The network system was monitored through the LAN system configuration, to confirm a malfunction of the network device. The results of the experiment indicate that a malfunction of the network occurs as the electric field increases. The data loss rate increases proportionally with increasing radiating time. In the case of the Switch Hub, the threshold electric field value was 10 kV/m for all conditions used in this experiment. The threshold point causing malfunction was influenced only by the electric field value. The correlation between the threshold point and pulse repetition rate was not found. However, in case of the Workstation, it was found that as the pulse repetition rate increases, the equipment responds weakly and the threshold value decreases. To verify the electrical coupling of the EUT by IEMI, current sensors were used to measure the PCB line inside the EUT and network line coupling current. As a result of the measurement, it can be inferred that when the coupling current due to IEMI exceeds the threshold value, it flows through the internal equipment line, causing a malfunction and subsequent failure. The results of this study can be applied to basic data for equipment protection, and effect analysis of intentional electromagnetic interference.

An Analysis of the Noise Feature of a Static Frequency Converter (SFC) according to the Operation of a Gas Turbine (가스터빈 기동에 따른 정지형 주파수 변환장치(SFC:Static Frequency Converter)의 노이즈 특성 분석)

  • Jeong, Tae-Hoon;Choi, Sung-Wook;Kim, Hyeun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2025-2026
    • /
    • 2008
  • This study aims to analyze the features of malfunction of an SFC that helps maintain the frequency of static rotation during the operation of a gas turbine in power plants where power generators and controllers have such a complicated structure as a nerve system, by using electric interference with peripheral devices and maintaining acquired data efficiently. Also, in order to track the possibility of malfunction by various surges and noises which may occur in the process of inserting an SFC during the operation of a gas turbine and to prepare protective measures for the possibility, the study intends to offer data for developing a surge protector suited to the features of a section that is supposed to incur the possibility of malfunction.

  • PDF

The Research for Malfunction and Installation Status of Power Quality Counterplan Equipment of Elevator (엘리베이터의 전원품질용 기기 설치 현황 및 오동작에 관한 조사)

  • Kim, Gi-Hyun;Yi, Geon-Ho;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.107-113
    • /
    • 2006
  • The number of confine-disease for elevator increases every year and then sudden stop, error of level indication stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. So we researched power quality counterplan equipment(SPD, Filter, Reactor) at site elevator controller room and malfunctions of elevator movement. We could confirm installation of power quality counterplan equipment recently and unchanging the number of malfunction. This data will be used the analysis for mutual relation between Power Quality(Sag, Interruption, ESD, ect.) and malfunction of elevator movement by testing the elevator equipment with EN12016(2004) and IEC standard level.