• Title/Summary/Keyword: Maintenance Rating

Search Result 120, Processing Time 0.027 seconds

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

A Development of Representative Condition Evaluation Standard for LNG Storage Tank Structures (LNG 저장탱크 구조물의 종합적 상태평가기준 개발)

  • Kim, Jung-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.44-51
    • /
    • 2018
  • As the LNG storage tank is aged, if there is a crack in the outer wall concrete or corrosion of the reinforcing steel, there is a risk of a major accident such as collapse of the structure depending on the type and degree of damage. Since 2014, LNG storage tanks have undergone precise safety diagnosis and safety inspection has been carried out. The condition evaluation criteria for each component have been revised and applied in January 2016. The condition evaluation standard is to evaluate the status of storage tanks based on the appearance survey and material test results of LNG storage tanks and it is important for maintenance. In addition, the representative condition evaluation standard that shows the comprehensive state of each LNG storage tank is important in maintenance, but the related standard for LNG storage tank outer concrete is not available in Korea and abroad, and development of the condition evaluation standard is necessary. In this paper, we examined the structural characteristics of LNG storage tanks, analyzed the status of the condition evaluation criteria for each member, and developed a comprehensive status rating system by weighting the members. We used the AHP(Analytic Hierarchy Process) technique and developed a representative conditon evaluation criteria through surveys of professional organizations.

The Study for Utilizing Data of Cut-Slope Management System by Using Logistic Regression (로지스틱 회귀분석을 이용한 도로비탈면관리시스템 데이터 활용 검토 연구)

  • Woo, Yonghoon;Kim, Seung-Hyun;Yang, Inchul;Lee, Se-Hyeok
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.649-661
    • /
    • 2020
  • Cut-slope management system (CSMS) has been investigated all slopes on the road of the whole country to evaluate risk rating of each slope. Based on this evaluation, the decision-making for maintenance can be conducted, and this procedure will be helpful to establish a consistent and efficient policy of safe road. CSMS has updated the database of all slopes annually, and this database is constructed based on a basic and detailed investigation. In the database, there are two type of data: first one is an objective data such as slopes' location, height, width, length, and information about underground and bedrock, etc; second one is subjective data, which is decided by experts based on those objective data, e.g., degree of emergency and risk, maintenance solution, etc. The purpose of this study is identifying an data application plan to utilize those CSMS data. For this purpose, logistic regression, which is a basic machine-learning method to construct a prediction model, is performed to predict a judging-type variable (i.e., subjective data) based on objective data. The constructed logistic model shows the accurate prediction, and this model can be used to judge a priority of slopes for detailed investigation. Also, it is anticipated that the prediction model can filter unusual data by comparing with a prediction value.

Feasibility Analysis of the Bridge Analytical Model Calibration with the Response Correction Factor Obtained from the Pseudo-Static Load Test (의사정적재하시험 응답보정계수에 의한 교량 해석모델 보정의 타당성 분석)

  • Han, Man-Seok;Shin, Soo-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.50-59
    • /
    • 2021
  • Currently, the response correction factor is calculated by comparing the response measured by the load test on a bridge with the response analyzed in the initial analytical model. Then the load rating and the load carrying capacity are evaluated. However, the response correction factor gives a value that fluctuates depending on the measurement location and load condition. In particular, when the initial analytical model is not suitable for representing the behavior of a bridge, the range of variation is large and the analysis response by the calibrated model may give a result that is different from the measured response. In this study, a pseudo-static load test was applied to obtain static response with dynamic components removed under various load conditions of a vehicle moving at a low speed. Static response was measured on two similar PSC-I girder bridges, and the response correction factors for displacement and strain were calculated for each of the two bridges. When the initial analysis model was not properly set up, it is verified that the response of the analytical model corrected by the average response correction factor does not fall within the margin of error with the measured response.

Effect of Fiber Volume Fractions on Flow and Uniaxial Tension Properties of 3D Printed SHCC (3D 프린팅용 SHCC의 흐름값과 1축 인장 특성에 미치는 섬유 혼입률의 영향)

  • Chang-Jin Hyun;Hyo-Jung Kim;Byung-Jae Lee;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.83-90
    • /
    • 2024
  • This study investigates the 3D printing characteristics of strain hardening cement composites (SHCC) reinforced by PVA fibers. Three SHCC mixtures with diverse fiber volume fractions (1.0% for F1.0 mixture, 1.5% for F1.5 mixture, and 1.8% for F1.8 mixture) were designed. Except for the F1.0 mixture, all mixtures met the necessary conditions for multiple micro-cracking, with higher fiber volume fractions more readily satisfying these conditions. The flow values of three SHCC mixtures were within the 3D printable range of 120~160 mm, exhibiting decreased flow values with increasing the fiber volume fractions. Observation of the printed SHCC surfaces indicated that the F1.0 mixture had a Level-3 (good) rating, while F1.5 and F1.8 were rated as Level-2 (average). Higher fiber volume fractions resulted in poorer surface quality, thus, further research needs to be performed for modulating SHCC mixture suitable for 3D printing. The uniaxial tension behavior showed that the F1.0 mixture failed at lower strain, whereas F1.5 and F1.8 exhibited higher strain performance with multiple micro-cracks occurring.

A Comparative Analysis of Domestic and Foreign Universities' Facility Management for Green Campus - Focusing on the Energy Management - (그린캠퍼스를 위한 국내.외 대학시설관리(FM) 비교분석 - 에너지관리 중심 -)

  • Shin, Eun-Young;Kim, Jun-Ha
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.1
    • /
    • pp.45-53
    • /
    • 2012
  • Recently, as the environment issue has been stand out, people's interests in energy consumption of the building have been increased as well. Especially, university has been classified as the one of the main causes of excessive energy consumption. Therefore, domestic and foreign universities are trying to build a green campus in an attempt for sustainable development. Since early 2000s, foreign universities have been aware that one of the main causes of global warming is an excessive consumption of energy in universities. Accordingly, they adopted various energy management programs for the conservation. Ultimately, enforcing energy conservation and using alternative energy resulted in lower expense and it was a great help for the universities. On the other hand, excessive consumption of energy in domestic universities has been considered as serious, which led them to become the second main energy consumers in 2010. However, it seems people do not truly recognize the impotance of energy management, therefore, relatively little attention has been paid to this matter. Based on Leadership in Energy & Environmental Design(LEED) rating systems for on-campus building operation and maintenance, this research suggests the evaluation standard to effectively analyze the energy management activity with the best practices conducted in foreign universities and to solve the problem of campus facilities management in domestic universities. The result shows that domestic universities do not have a designated task force for effective energy management and the lack of energy professionals hinders for the long term development. Therefore, domestic universities should recognize the seriousness of the excessive energy consumption and develop low carbon green campus through proactive management practices since this is very essential for domestic universities to get more competitive in this global era.

Co-administration of Paroxetine and Haloperidol : Changes of Symptoms and Blood Level of Haloperidol, Reduced Haloperidol (만성 정신분열증 환자에서 Paroxetine과 Haloperidol 병합투여시 정신병리증상과 Haloperidol, Reduced Haloperidol 혈중농도의 변화)

  • Han, Chang Su;Lee, Min Soo;Kim, Pyo Han
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.251-257
    • /
    • 1996
  • Selective serotonin reuptake inhibitors(SSRIs), as haloperidol, ore metabolized in the cytochrome P450IID6. They can cause inhibition of metabolism of antipsychotics to elevate the serum level of antipsychotics and exacerbate the extrapyramidal symptoms when co-administered with antipsychotics. Among these SSRIs, there ore a few studies about paroxetine compared to fluoxetine or sertraline. In this study, we have intended to know the drug interaction of paroxetine and haloperidol when co-administered two drugs for the chronic schizophrenics by assessing the changes of positive, negative symptoms and extrapyramidal symptoms. for this purpose, we selected 29 subjects, the chronic schizophrenics with no physical problems. They were under maintenance therapy of haloperidol. They ore randomly assigned to placebo group(n=12) and drug group(n=17) by using double blind method. And then, placebo or paroxetine 20mg were administered to the subjects of each groups during 8 week period. We have assessed their psychopathology and extrapyramidal symptoms using Positive and Negative Syndrome Scale(PANSS), Hamilton Rating Scale lor Depression(HRSD), Simpson-Angus Scale at 0, 2, 4, 6, 8 weeks and serum haloperidol, reduced haloperidol levels at 0, 4, 8 weeks during the period. The results ore analysed by using repeated measure MANOVA. 27 subjects have completed the study during 8 weeks. among the subjects, 1) PANSS, HRSD ; no significant difference between groups. 2) Simpson-Angus Scale ; no significant change according to the time and no significant difference between the groups(no group and time effect). 3) Haloperidol and reduced haloperidol level ; no significant change. When co-administered paroxetine and haloperidol, there ore no significant changes of the psychopothology and no significant changes of the extrapyramidal symptoms. In this result, paroxetine seems to be not to affect the metabolism of haloperidol.

  • PDF

Representation of Drinking in Cultural Contents: Analysis of Television Drama Texts (지상파 TV 콘텐츠에 나타난 음주 : 황금시간대 고시청률 드라마 분석과 수용자 인식조사)

  • Yang, Jung-Hye
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.253-264
    • /
    • 2010
  • This study aimed to 1) analyze television drama text to examines how Korean television dramas represent alcohol drinking; 2) interview the actual drama audience to examine how they perceive drinking and whether or not their perception is influenced by the drama text. The author analyzed 60 drama episodes from 12 prime time shows that reached over 20% rating from 2008 to 2010. The result shows that drinking in dramas are portrayed as a solution to various kinds of personal and business problems, medium of romance, a tool for interpersonal communication that facilitates understanding and positive relationship. Female drinkers are prominent but their drinking is taking place under the patronage of male characters, which lead to the maintenance of patriarchal social relations. Interview findings show that the audience have strong motivation to imitate the glamourous lifestyles of leading characters in dramas. The findings strongly suggest observational learning was taking place, especially in the area where the viewers have no direct experience.

Turfgrass Selection for Soccer Fields - A Simulation of the Inchon 2002 World Cup Stadium - (축구경기장의 잔디초종 선정에 관한 연구 - 2002년 월드컵 인천경기장 모형돔을 대상으로 -)

  • 심상렬;정대영
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.2
    • /
    • pp.88-94
    • /
    • 2002
  • This study was conducted to select suitable turfarasses for use at 2002 world cup soccer fields in Korea. A 1/1000 scale Inchon worldcup soccer dome was constructed for this research. Species and seeding rates of cool-season grasses used inside and outside the dome were Kentuck bleugrass 10g/$m^2$ (KB), Kentucky bleugrass 10g/$m^2$+ perennial ryegrass 10g/$m^2$ mixture (KB+PR) and Kentucky bleugrass 6g/$m^2$+tall fescue 14g/$m^2$+ perennial ryegrass 4g/$m^2$ mixture (KB+TF+PR). Warm-season grasses also used in this study were Zoysia japonica 'Anyangjungzii' (ZA) and Zoysia japonica 'Zenith'(ZZ) which were layed as sod. So, total 5 types of grasses were used inside and outside the dome. The rootzone was constructed by the multi-layer method(United States Golf Association method). The plots were designed by randomized block design. Cool-season grasses(KB, KB+PR, KB+TF+PR) were found to be better performers for visual rating and visual color than the zoysiagrasses(ZA, ZZ). There were no significant differences in turf performance within cool-season grasses, while ZA showed better turf performances than ZZ within zoysiagrasses. The green color was maintained for about 10 months in the col-season grasses(KB, KB+PR, KB+TF+PR) compared to about 5~6 months in the zoysiagrasses. Root length and density data revealed higher values for KB, KB+PR and KB+TF+PR compared to ZA and ZZ. Root performance of 22 was better than ZA within zoysiagrasses which was the opposite result of turf performances. There was also no significant difference between U performance inside and outside the dome. However, the decreasing tendency of turf quality inside the dome at the end of the study showed that more proper maintenance technology was needed inside the d[me. It could be concluded by this study that cool-season grasses(KB, KB+PR, KB+TF+PR) were more suitable turfgrasses than waits-season zoysiagrasses(ZA, ZZ) for use at 2002 world cup soccer fields in Korea.

Design of a Multi-Protocol Gateway System Based on Low Power Wireless Communications (저전력 무선통신 기반 다중 프로토콜 게이트웨이 시스템 설계)

  • Hong, Sung-IL;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.10
    • /
    • pp.2006-2013
    • /
    • 2015
  • In this paper we propose a multi-protocol gateway system based on low power wireless communications. The proposed multi-protocol gateway system was designed to allow real-time monitoring and control of the on-site situation through wired and wireless networks by gathering information for streetlight power control and environmental monitoring. The sensing data using multi-sensors with composite processing that selectively used wired or wireless communication (e.g., CDMA, Ethernet (TCP/IP), GPS, etc.) were designed to act as intermediaries that transmitted to the main server through ZigBee. Inaddition, they were designed by separating a CPU board and baseboard to ensure low maintenance cost and ease of hardware replacement. The proposed multi-protocol gateway system's power, impact, continuous operation stability, and immunity test results obtained a normal operation success rate of over 95% and normal continuous operation results. Moreover, in the voltage drop test, instantaneous immunity test, and conductive RF electromagnetic field immunity test, it obtained an average rating result of "A".