• Title/Summary/Keyword: Main stretcher

Search Result 11, Processing Time 0.026 seconds

Evaluation of 119 emergency medical technicians' work related musculoskeletal disorders risk with regard to patient lifting procedures (119 구급대원의 업무관련성 근골격계 손상 위험성 평가 - 환자 들기 작업을 중심으로 -)

  • Son, Jeong-Won
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.101-112
    • /
    • 2019
  • Purpose: The purpose of the study was to contribute to the prevention of musculoskeletal disorders (MSDs) in 119 emergency medical technicians (EMTs) by evaluating ergonomic risk factors of patient lifting work-postures. Methods: Four procedures were evaluated: using long back-board (LBB) on the sitting and standing main stretcher, using variable stretcher on the sitting and standing main stretcher. Wok-postures were assessed during training. Results: In using LBB on the sitting main stretcher, the OWAS-score was Mode:3 (Mean:2.30, Maximum:3), the REBA-score was Mode:9 (Mean:7.61, Maximum:11), requiring improvement soon. In using LBB on the standing main stretcher, the OWAS-score was Mode:3 (Mean:2.33, Maximum:3), requiring as soon as possible corrective action, the REBA-score was Mode:6 (Mean:5.44, Maximum:11), requiring improvement. In using variable stretcher on the sitting main stretcher, the OWAS-score was Mode:1 (Mean:1.85, Maximum:3), not requiring corrective action, the REBA-score was Mode:6 (Mean:6.78, Maximum:11), requiring improvement. In using variable stretcher on the standing main stretcher, the OWAS-score was Mode:3 (Mean:2.84, Maximum:3), requiring as soon as possible corrective action, the REBA-score was Mode:11 (Mean:9.38, Maximum:11), requiring immediate improvement. Conclusion: All four-procedures showed improvement in work-posture. Thereby, required attention and management in training, occupational health professionals should participate in change of lifting-method, and programs aimed at preventing MSDs should be developed and implemented in fire-academy and fire-station.

A Chest Compression CPR Study Performed on a Main Stretcher : Comparative study between C-step and Over the Belly

  • Gyu-Sik Shim;Song-Yi Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.123-129
    • /
    • 2024
  • CPR is very important to paramedics, but the chest compression performed while on the move main stretcher is less accurate. The purpose of this study is to find out the difference between performing chest compression on the side of the main stretcher using C-step and on the patient's over the belly in order to increase the effect of CPR on the main object while on the move. As a result of the study, the appropriate depth (t=4.132, p=.000) and speed (t=7.177, p=.000) were shown in the group to which the C-step was applied, and the accuracy was higher (t=6.774, p=.000). In addition, it was found that there were few location defects (t=-5.197, p=.000) and too shallow errors (t=-2.948, p=.008) in the group to which the C-step was applied. In conclusion, mounting a C-step on the main stretcher seems to help improve the quality of chest compression, and it is thought that this will increase the efficiency of chest compression.

Chest Compression Energy(kg) Measurement of 4 Types of Rescue Device on the Floor (4종류의 구급장비 및 마루(Floor) 위에서 시행한 가슴압박 에너지(kg)측정 실험에 관한 연구)

  • Shin, Dong-Min;Han, Yong-Taek;Kim, Seung-Yong;Park, Si-Eun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to investigate the effect of high quality CPR using the 4 types of rescue device equipment and chest compressions energy measurement in pre-hospital settings. So, we used the mode to insert load cell in ALS Skill master Manikin to develop CFMM(Compression Force Measurement Manikin) on main stretcher, CPR board, long spine board, scoop stretcher and floor. And, our research team could know that the main stretcher needed average force of 32.55 (${\pm}1.01$) kg, CPR board of 27.23 (${\pm}1.08$) kg, long spine board of 27.13 (${\pm}1.18$) kg, Scoop Stretcher of 27.38 (${\pm}1.05$) kg and Floor of 27.24 (${\pm}0.93$) kg. CPR board must be necessary in the case of CPR on main stretcher in a moving ambulance. But if the condition of patient's back surface is the removable stretcher and the long spine plate, the patient doesn't have to be spent time to use a CPR board. Furthermore, this research suggests to consider that how to take advantage of the education to students for the equipment to check in real time the energy(kg) requirement of chest compressions.

The Effect of applying Subsidiary step developed for CPR on the main stretcher during movement (이동 중 주들것에서 심폐소생술을 위해 개발된 보조발판(C-step)의 적용 효과)

  • Shim, Gyu-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5950-5957
    • /
    • 2012
  • CPR with minimized hands-off time is one of integral factors for the improvement of the survival rate of patients. The purpose of this study was to examine the relationship of the installation of C-steps on the main stretcher to CPR accuracy and errors. The subjects in this study were 70 paramedics in 10 firehouses in the province of C(35 for control group, 35 for experimental group), and their CPR accuracy on the main stretchers was checked. As a result, it's found that the main stretchers equipped with the C-steps served to boost the accuracy of chest compression by creating suitable environments for that in terms of height and posture(t=65.104, p=.000), to improve the accuracy of artificial respiration by providing a proper amount of ventilation(t=5.207, p=.000), and to bolster the self-confidence of the paramedics about CPR(t=-10.612, p=.000). In conclusion, the mounting of C-steps on the main stretcher is expected to be of use for the improvement of the survival rate of cardiac-arrest patients by ensuring the precise performance of high-quality CPR.

A Study on the Problems and Improvement Solutions for the Ambulance Stretcher (119구급대 주들것의 문제점과 그 개선방안에 관한 연구)

  • Ham, Seung Hee;Song, Woo Seung;Yoon, Myung O
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.72-79
    • /
    • 2014
  • The purpose of this study is to draw the improvement plan through the analysis of problems of main stretchers that are being used by the 119 EMS. In order to find out the problems, we used the literature review and analysis, survey questionnaire and we also made full use of KJ method (Kawakita Jiro method, affinity diagram), graph method, and priority matrix method to produce the improvement indicators. The problems of main stretchers are summarized as follows. they are being recognized as part of the emergency vehicle, they have the imperfection of performance verification criteria, and they cause the injuries of paramedics and patients accidents in operation. The indicators such as the ease of operation, the high performance, the multi-function, the driving performance, the durability and the lightweight, was produced to improve the problems. The results of the interconnection analysis and the applying priority matrix method on the indicators are the ease of operation ${\rightarrow}$ the multi-function ${\rightarrow}$ the driving performance ${\rightarrow}$ the high performance ${\rightarrow}$ the durability and the lightweight in order of importance.

Study on the Displacement of Crib Wall System (Crib Wall System 변위해석에 관한 연구)

  • Kim, Doo-Jun;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.201-209
    • /
    • 2002
  • Crib wall system is one of segmental crib type wall. Crib walls are constructed from separate members with no bonds between them other than frictional. The wall units are divide into two main types termed headers and stretchers. The headers run from the front to the back of the wall, perpendicular to the wall face. The cells are created by forming a grid by stacking individual wall components known as headers and stretchers. The body of wall consists of a system of open cell which are filled with a granular material. The design of crib retaining wall is usually based on conventional design methods derived from Rankine and Coulomb theory so that is able to resist the thrust of soil behind it, because it may be assumed that the wall acts as a rigid body. However, deformation characteristics of crib walls cannot be assumed as monolithic. They consist of individual members which have been stacked to creat a three dimensional grid. Therefore, the segmental grid allows relative movement between the individual member within the wall. The three dimensional flexible grid leads to stress distribution by interaction behavior between soil and crib wall. Therefore, in this study, in order to analysis the trends of deflection of crib wall system, new numerical models based on the results of Brandl's full scale test are introduced for design concept.

Analysis of cardiopulmonary resuscitation during main stretcher transport - A manikin study - (이동 중 주들것에서 심폐소생술 분석)

  • Roh, Sang-Gyun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.2
    • /
    • pp.39-50
    • /
    • 2020
  • Purpose: This study aimed to compare the effect of chest compression and the resulting ventilation volume in walking cardiopulmonary resuscitation (CPR), straddling CPR, and mechanical CPR while moving manikins to main stretchers. Methods: We compared the chest compressions in terms of compression depth, number of incomplete releases, complete release depth, compression rate, duration between peak time of previous compression and peak time of current compression, and respiration. We analyzed the compression comparatively with the ventilation volume in three different types of CPR. Results: The chest compression depth was significantly improved during straddling CPR as compared to walking CPR, during which women were unable to achieve sufficient chest compression depth. A constant chest compression depth was maintained during mechanical CPR. Conclusion: High-quality chest compressions were difficult to achieve in moving spaces. Further, walking CPR may be helpful in men, but straddling or applying automatic chest compressions in women would result in more effective CPR. Our findings demonstrate the limitations and trends in administering CPR in men and women, which may be useful in devising better education and training methods in the future.

RESEARCH ON LASER-ACCELERATED PROTON GENERATION AT KAERI

  • PARK SEONG HEE;LEE KITAE;CHA YOUNG HO;JEONG YOUNG UK;BAIK SUNG HOON;YOO BYUNG DUK
    • Nuclear Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.279-286
    • /
    • 2005
  • A prototype of a relativistic proton generation system, based on laser-induced plasma interaction, has been designed and fabricated. The system is composed of three major parts: a fs TW laser; a target chamber, including targets and controls; and a diagnostic system for charged particles and lasers. An Offner-type pulse stretcher for chirped pulse amplification (CPA) and eight pass pre-amplifier are installed. The main amplifier will be integrated with a new pumping laser. The design values of the laser at the first stage are 1 TW in power and 50 fs in pulse duration. We expect to generate protons with their maximum energy of approximately 3 MeV and the flux of at least $10^6$ per pulse using a 10 $\mu$m Al target. A prototype target chamber with eight 8-inch flanges, including target mounts, has been designed and fabricated. For laser diagnostics, an adaptive optics based on the Shack-Hartmann type, beam monitoring, and alignment system are all under development. For a charged particle, CR-39 detectors, a Thomson parabola spectrometer, and Si charged-particle detectors will be used for the density profile and energy spectrum. In this paper, we present the preliminary design for laser-induced proton generation. We also present plans for future work, as well as theoretical simulations.

Endotracheal Intubation of Paramedics in a Moving Ambulance (이동 중 구급차에서 1급 응급구조사의 기관내 삽관)

  • Shim, Gyu-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5292-5298
    • /
    • 2012
  • The purpose of this study is to perform the effectively advanced airway management in an emergency patient with cardiac arrest and trauma by comparing the appearance of influence in a change of visual-field height upon endotracheal intubation according to a change in position with intubation of paramedics in a moving ambulance and by analyzing the appearance of the influence in a patient's change in position with intubation upon speed in endotracheal intubation. Research subjects were randomly extracted 60(30 people for control group, 30 people for experimental group) people as the paramedics who are working at 13 fire stations in C Province. Data analysis was carried out ${\chi}^2$-test, independent t-test, paired t-test by using SPSS WIN 14.0 Version. As a result of research, to improve speed of the advanced airway management, it is considered to be likely effective in a patient's sniffing position and in the endotracheal intubation in the upper space of the main stretcher. The self-confidence in intubation after experiment increased significantly. Thus, the continuous education(training) on the intubation position and method within ambulance is considered to be likely needed for improving efficiency of the advanced airway management.

A study on improving the interior design of ambulance (구급차 내부 디자인 개선에 관한 연구)

  • Shin, Dong-Min;Park, Si-Eun;Park, Shin-Hye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.17 no.3
    • /
    • pp.9-20
    • /
    • 2013
  • Purpose: This research project addressed the need to designing more safe and efficient interior of the future ambulance in Korea. Methods: The study sample contained 760 paramedics in 4 districts. Data was collected by using a revised and complemented questionnaire based on literature review. Results: In relation to the efficacy and safety of work, answers related to storage closet showed to be the highest, and the most difficult part of paramedic work in an ambulance was lurching. CPR is the most frequently used emergency care inside an ambulance, but 66% of the paramedics responded that accurate CPR is not possible during vehicle transfer. Safety belts are not worn for 82.8% of the time, because of discomfort (51.3%). 13.8% of the paramedics responded that stretchers are unstable, 29.5% had an experience of having patients fall off the stretcher inside an ambulance. There were comments on installing equipments to prevent noise, and assist communication. Conclusion: The suggested practical layout contains five main modifications 1. Developing specially designed belt is needed for paramedic safety & efficient work. 2. The seats are molded to be ergonomically friendly. 3. Equipments to secure the body and safety devices for CPR are needed. 4. System improvement for communication between the driver seat and paramedics is needed. 5. The stretchers are molded to be maximize efficiency and minimize injury.