• 제목/요약/키워드: Main cooling system

검색결과 302건 처리시간 0.031초

Numerical study on thermal-hydraulics of external reactor vessel cooling in high-power reactor using MARS-KS1.5 code: CFD-aided estimation of natural circulation flow rate

  • Song, Min Seop;Park, Il Woong;Kim, Eung Soo;Lee, Yeon-Gun
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.72-83
    • /
    • 2022
  • This paper presents a numerical investigation of two-phase natural circulation flows established when external reactor vessel cooling is applied to a severe accident of the APR1400 reactor for the in-vessel retention of the core melt. The coolability limit due to external reactor vessel cooling is associated with the natural circulation flow rate around the lower head of the reactor vessel. For an elaborate prediction of the natural circulation flow rate using a thermal-hydraulic system code, MARS-KS1.5, a three-dimensional computational fluid dynamics (CFD) simulation is conducted to estimate the flow rate and pressure distribution of a liquid-state coolant at the brink of significant void generation. The CFD calculation results are used to determine the loss coefficient at major flow junctions, where substantial pressure losses are expected, in the nodalization scheme of the MARS-KS code such that the single-phase flow rate is the same as that predicted via CFD simulations. Subsequently, the MARS-KS analysis is performed for the two-phase natural circulation regime, and the transient behavior of the main thermal-hydraulic variables is investigated.

Roll-to-Roll 스퍼터로 성장시킨 플렉시블 ITO 전극을 이용한 플렉시블 유기태양전지 제작 (Fabrication of flexible organic solar cells on Roll-to-Roll sputter grown flexible indium tin oxide electrode)

  • 최광혁;강재욱;김한기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.64-64
    • /
    • 2008
  • 연속공정이 가능한 Roll to Roll sputter system을 이용하여 플렉시블 indium tin oxide(ITO) 투명전극을 PET(polyethlyene terephthalate) 기판위에 성막하였다. 연속 성막공정을 위해 Roll to Roll sputter system에서의 unwinder roller와 rewinder roller를 이용한 servomotor의 rolling으로 기판의 움직임이 완벽히 제어되었으며, 외부 응력으로 부터의 안정성 및 성막 공정 시의 PET 기판의 열적 변형을 최소화하기 위한 접촉식 냉각방식의 cooling system을 main drum으로 사용하였다. 또한 고분자 기판과 투명전극 사이의 adhesion을 향상시키기 위한 전처리 공정으로 gridless linear ion beam source를 pretreatment system으로 구축하였다. 이렇게 제작된 Roll to Roll sputter system을 이용하여 PET 기판위에 연속공정을 통해 ITO 투명전극을 성막하였다. 성막된 플렉시블 ITO/PET 투명전극은 XRD, HREM, SEM 분석을 통하여 main drum의 cooling에 의해 완전한 비정질 구조를 나타내었음을 확인할 수 있었으며, 비록 Roll to Roll sputter system을 통하여 상온에서 성막 되었음에도 불구하고 최적화 된 조건에서 가시광선 영역 83.46 %의 높은 광투과도 값과 47.4 Ohm/square의 비교적 낮은 먼저항 값을 얻을 수 있었다. 또한 Bending test 결과를 통하여 ion source의 전처리 공정으로 굽힘/평의 반복적 응력에 따른 전기적 특성 열화를 최소화 할 수 있음을 보였다. 최적화된 플렉시블 투명전극을 이용하여 P3HT:PCBM 기반의 플렉시블 유기태양전지를 제작하였으며, 제작된 유기태양전지로부터 1.88%의 power conversion efficiency (PCE)을 확보함으로써 플렉시블 유기태양전지 제작을 위한 ITO/PET 투명전극 성막 공법으로써 Roll to Roll sputter system의 적용가능성을 확인할 수 있었다.

  • PDF

액체로켓 연소실 냉각에 관한 실험적 연구 (An experimental study on the liquid rocket combustion chamber cooling)

  • 김병훈;박희호;정용갑;김유
    • 한국추진공학회지
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2001
  • 매우 높은 연소가스로부터 연소실을 보호하기 위하여 액체로켓에서는 재생냉각방법을 폭넓게 이용하고 있다. 재생냉각을 통한 로켓엔진의 냉각을 매우 효과적인 방법이지만, 이를 개발하기 위해서는 정확한 해석과정, 제작기술 등이 필요하다. 한다. 실제 소형 로켓엔진에 재생냉각을 이용한 엔진 냉각의 가능성을 확인하기 위하여 설계, 제작된 로켓으로 연소실험을 진행하였다. 실험에 사용한 연소실은 coolant passage 3 mm, 벽 두께 1 mm, stainless 304로 제작하였다. 최대연소압과 연소시간은 각각 400 psi와 60 sec이고, coolant 유량은 2 kg/s에서 0.12 kg/s까지 감소시키면서 실험하였다. 연소시험후 육안으로 검사한 결과 연소실에서 특별한 이상은 발견되지 않았다.

  • PDF

30톤급 연소기의 연소시험을 위한 설비 개량 (Rocket Engine Test Facility Improvement for Hot firing test of a Combustor in the 30-tonf class)

  • 이광진;서성현;임병직;문일윤;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.313-317
    • /
    • 2005
  • The facility improvement for hot firing test of combustion chamber having thrust of 30-tonf class and chamber pressure of 60bara were performed at ReTF in KARI. The KSR-III main engine having combustion pressure of 13bara and thrust of 12.5tonf had been successfully tested in this facility. To increase the capability of the facility, the feeding and the trust measurement system have been modified. The modification of the feeding system plays also a role of ensuring the stability of propellant supply and two step ignition sequence of combustion chamber. The one-axis thrust measurement system of up to 60tons has been newly manufactured and installed in test stand and the water/kerosene supply lines with high pressure vessel of $4m^3$ and gas nitrogen vessel of $10m^3$ have been designed for regenerative cooling system. The results of cold flow test show that this facility has been successfully improved to satisfy the requirement for hot firing test of high performance combustor.

  • PDF

부하추종 냉각수 시스템의 온도 제어를 위한 유전알고리즘 기반 비선형 PID 제어기 설계 (Genetic algorithm-based design of a nonlinear PID controller for the temperature control of load-following coolant systems)

  • 이유수;황순규;안종갑
    • 수산해양기술연구
    • /
    • 제58권4호
    • /
    • pp.359-366
    • /
    • 2022
  • In this study, the load fluctuation of the main engine is considered to be a disturbance for the jacket coolant temperature control system of the low-speed two-stroke main diesel engine on the ships. A nonlinear PID temperature control system with satisfactory disturbance rejection performance was designed by rapidly transmitting the load change value to the controller for following the reference set value. The feed-forwarded load fluctuation is considered the set points of the dual loop control system to be changed. Real-coded genetic algorithms were used as an optimization tool to tune the gains for the nonlinear PID controller. ITAE was used as an evaluation function for optimization. For the evaluation function, the engine jacket coolant outlet temperature was considered. As a result of simulating the proposed cascade nonlinear PID control system, it was confirmed that the disturbance caused by the load fluctuation was eliminated with satisfactory performance and that the changed set value was followed.

PERSPECTIVES IN SYSTEM THERMAL-HYDRAULICS

  • D'auria, F.
    • Nuclear Engineering and Technology
    • /
    • 제44권8호
    • /
    • pp.855-870
    • /
    • 2012
  • The paper deals with three main topics: a) the definition of System Thermal-Hydraulics (SYS TH), b) a historical outline for SYS TH and, c) the description of elements for reflection when planning research projects or improvement activities, this last topic being the main reason for the paper. Distinctions between basic thermal-hydraulics and computational Fluid-Dynamics (CFD) on the one side and SYS TH on the other side are considered under the first topic; stakeholders in the technology are identified. The proposal of Interim Acceptance Criteria for Emergency Core Cooling Systems in 1971 by US NRC (AEC at the time) is recognized as the starting date or the triggering event for SYS TH (second topic). The complex codes and the main experimental programs (list provided in the paper) constitute the pillars for SYS TH. Caution or warning statements are introduced in advance when discussing the third topic: a single person (or a researcher) has little to no possibility, or capability, of streamlining the forthcoming investments or to propose a roadmap for future activities. Nevertheless, the ambitious attempt to foresee developments in this area has been pursued without constraints connected with the availability of funds and with industrial benefits or interests. Demonstrating the acceptability of current SYS TH limitations and training in the application of those codes are mentioned as the main challenges for forthcoming research activities.

초저온 식각을 위한 냉각용량 2kW 급 -100 ℃ 비가연성 혼합냉매 줄톰슨 냉각기의 실험적 고찰 (Experimental Investigation of 2kW Class Non-flammable Mixed Refrigerant Joule-Thomson Refrigerator with Cooling Temperature of -100 ℃ for Cryogenic Etching)

  • 은종민;이천규
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.6-11
    • /
    • 2024
  • This paper presents the design and experimental analysis of a cryogenic refrigeration system for -100 ℃, primarily intended for semiconductor etching process. The refrigeration system utilizes non-flammable mixed refrigerant Joule-Thomson refrigeration cycle, incorporating a precooling stage to enhance overall performance. The selected refrigerants for the system include R1234yf for the precooling stage, and Ar, R14, R23 and R218 for the main cooling stage of the Joule-Thomson refrigeration cycle. Design results according to the system constraints and experimental results are discussed, including lowest evaporation temperature, compressor isentropic efficiency and overall pressure tendencies. The achieved refrigerant fraction from optimal design is Ar: R14: R23: R218 = 0.15: 0.4: 0.15: 0.3, indicating COP of 0.1118 at the isentropic compressor efficiency of 50%. The experimental result shows the developed system reaches steady state in approximately 3 hours.

  • PDF

CDA 인입공기 증발냉각을 통한 압축기 성능 개선장치 개발 연구 (On-Site Measurement of the Inlet Air Evaporative Cooling Performance for a Centrifugal Turbo Compressor)

  • 김규완;박진욱;김희동
    • 대한기계학회논문집B
    • /
    • 제38권11호
    • /
    • pp.873-879
    • /
    • 2014
  • CDA(Clean Dry Air) System 에서 공기 압축기는 핵심 설비이자 소비되는 전력의 대부분을 차지한다. 그리하여 압축기 성능(ECI)을 개선함으로써 CDA System 전체성능을 크게 향상 시킬 수 있다. 종래의 많은 연구를 통해 인입공기의 온/습도 조건이 압축기에 미치는 영향에 대해 잘 알려져 있으나, 본 연구에서는 인입공기의 조건에 따라 소비되는 실제 전력 및 토출유량의 상관관계를 조사하였다. 또한 증발 냉각장치를 설치하여 인입공기 조건의 다양한 변화를 통하여 압축기성능에 미치는 영향을 연구하였다. 얻어진 결과로부터 인입공기의 온/습도가 낮을수록 압축기성능이 개선되었고, 증발냉각장치를 설치하였을 때 압축기성능이 개선됨을 알았다.

Development of the Near Infrared Camera System for Astronomical Application

  • 문봉곤
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF