• Title/Summary/Keyword: Main Wall

Search Result 1,029, Processing Time 0.026 seconds

Analysis of Wall-Thinning Effects Caused by Power Uprates in the Secondary System of a Nuclear Power Plant (원전 2차계통의 출력증강 운전에 따른 배관감육 영향 분석)

  • Yun, Hun;Hwang, Kyeongmo;Lee, Hyoseoung;Moon, Seung-Jae
    • Corrosion Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.135-140
    • /
    • 2016
  • Piping and equipment are degraded by flow-accelerated corrosion (FAC) in nuclear power plants. FAC causes numerous problems and nuclear utilities maintain programs to control FAC. The key parameters influencing FAC are hydrodynamic conditions, water chemistry, and effect of materials. Recently, a nuclear utility has planned slight power uprates in Korea. Operating conditions need to be changed in the secondary system according to power uprates. This study analyzed the effect of wall-thinning caused by power uprates. The change of operation data in the secondary cycle is reviewed, and wall-thinning rates are analyzed in the main lines. As a result, two phase (mixture of water and steam) lines have a greater impact than a water line under power uprate conditions. Also, the quality of steam is the most important factor for FAC in two phase lines.

Experimental Study on the Shear Capacity of Composite Basement Walls (합성 지하벽의 전단내력 산정에 관한 실험적 연구)

  • 김성만;이성호;서수연;이리형;홍원기;장재호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.379-384
    • /
    • 2001
  • This paper presents the experimental result of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector. Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, arrangement of shear connector, thickness of wall, shear span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

  • PDF

Analysis of Arc Tube Properties by Degradation in Ceramic Metal Halide Lamp

  • Yang, Jong-Kyung;Jang, Hyeok-Jin;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.123-127
    • /
    • 2011
  • To clarify the relations of optical properties to the main factors responsible for the loss and damage of luminous efficacy, a 20 min turn-on/turn-off test for 2,000 h for a ceramic metal halide lamp is conducted. The corrosion rates of the arc tube wall and electrode are estimated based on thermal stress. Wall blackening is attributed to the tungsten being transported from the hot electrode tips to the relatively cold arc tube wall. Furthermore, the grain boundaries of the arc tube are changed by the degradation. Distortion of the electrode is observed, and the ignition and the driving voltage of the load both increase. Finally, the color rendering index and the color coordinates are changed after the degradation. The luminous flux and the intensity of the luminous distribution are decreased significantly.

A Study on Seismic Performance Evaluation of RC Frame Retrofitted by Masonry Infill Wall and Steel Damper (조적채움벽 및 강재댐퍼 보강 RC 골조의 내진성능 평가에 관한 연구)

  • Lee Jung Han;Yang Won Jik;Kang Dae Eon;Song Han Beam;Oh Sang Hoon;Yi Waon Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.129-132
    • /
    • 2005
  • The primary purpose of this investigation is to find out the shear behavior and the shear capacity of RC bare frames, brick-infilled RC frames, and damper-retrofitted RC frames and to evaluate the average shear strength of brick--infill wall. The main variables art the absence of brick infill wall and steel plate slit damper. The test results show that the shear capacity of specimen IF-DR is 2.8 times as high as that of the specimen BF and it presents the fact that the retrofitting effect and the possibility of RC frame reuse with changing the slit damper is verified. And the average shear strength of the brick infill wall is figured to be at $5.0 kgf/cm^2$.

  • PDF

A Field Survey of Idiosyncratic Dwelling Space attached to Chang-Duk Palace's West Fence (창덕궁 담에 접한 자생주거지에 관한 연구 - 원서동 무허가 94번지의 실측 및 개선 안 기초연구 -)

  • 윤숙희;정진원
    • Journal of the Korean housing association
    • /
    • v.14 no.1
    • /
    • pp.29-40
    • /
    • 2003
  • The purpose of this research is to document and analyse spatial transformation of an unauthorized dwelling units on a peculiar site of Seoul. It's physically attached to the behind part of the west boundary wall of Chang-Duk Palace. These dwelling units took not only the site, the narrow street which had been a stream, but also the two parallel walls of others for their home. The two walls, one from the palace wall and the other from the wall of a house which distanced itself from the palace wall about 3.5 m for the reason of the Cultural Properties Protection Law, have been held as the main structural members in forming the shelter. With examining the realm of time which provide the base of the spatial realm, this research shows how the multiple linkages tangled in an illegal shack did gain and actualize an architectural language of idiosyncrasy with spontaneous order inherent in inhabitants.

Brief Review of Studies on Concrete Wall Panels in One and Two Way Action

  • Doh, Jeung-Hwan;Fragomeni, Sam;Kim, Jin-Woo
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.4 no.1
    • /
    • pp.38-43
    • /
    • 2001
  • This paper provides review of research results undertaken on reinforced concrete wall panels in one way and two way. The review also highlights two well accepted code design methods from the American (ACI) and Australia Concrete structures standards. The emphasis is on walls under axial compression only with changes in various parameters. These include the variation of panel dimensions panels (ie. Slenderness, thinness and aspect ratios), steel reinforcement, eccentricities, concrete strength and support conditions. The main purpose of this review is to compile research previous by undertaken to highlight the inadequate in certain research literature. It is envisage that this review will expose areas in wall research required so that inadequate in current methods can be rectified.

  • PDF

DNS of turbulent heat transfer in a concentric annulus (동심 환형관 내 난류 열전달의 직접 수치 모사)

  • Chung Seo Yoon;Sung Hyung Jin
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.827-830
    • /
    • 2002
  • A direct numerical simulation is performed for turbulent heat transfer in a concentric annulus at $Re_{Dh}=8900\;and\;Pr=0.71$ for two radius ratios ($R_{1}/R_{2}=0.1\;and\;0.5$) and $q^{\ast}=1.0$. Main emphasis is placed on the transverse curvature effect on near-wall turbulent thermal structures. Near-wall turbulent structures close to the inner and outer walls are scrutinized by computing the lower-order statistics. The fluctuating temperature variance and turbulent heat flux budgets are illustrated to confirm the results of the lower-order statistics. The present numerical results show that the turbulent structures near the outer wall are more activated than those near the inner wall, which may be attributed to the different vortex regeneration processes between the inner and outer walls.

  • PDF

Stability Analysis of Discontinuous Rock by the Block Theory (블록이론에 의한 불연속성 암반내 터널의 안정성 해석)

  • 양형식
    • Tunnel and Underground Space
    • /
    • v.1
    • /
    • pp.66-74
    • /
    • 1991
  • The block theory with stereographic projection was applied and analyzed on the tunnel section of Samcheok Coal Mine. The results were as follows ; 1) Prevail orientations of discontinuity of sandstone around the main driftway of Samcheok Coal Mine were $(327^{\circ},\;44^{\circ}),\;(13^{\circ},\;24^{\circ}),\;(204^{\circ},\;65^{\circ})$ and $(225^{\circ},\;77^{\circ})$ in dip and dip direction, respectively. 2) Movable blocks of the site were 0110, 0111, 1110(roof), 0100, 0110, 1110(right wall) and 0001, 1001, 1011(left wall). Because of the direction of tunnel, blocks of the left wall was safe. thus key blocks were those of the roof and the right wall. Maximum height of key block was larger than the width of the tunnel but 2m of the yielded zone is expected in general for 5m width tunnel. 3) It is shown that block theory is applicable to large cavern in hard rock analysis.

  • PDF

Review on the Integrity Evaluation and Maintenance of Wall-Thinned Pipe (감육배관의 건전성평가 및 정비 관련 기술기준 고찰)

  • Lee, Sung Ho;Lee, Yo Seob;Kim, Hong Deok;Lee, Kyoung Soo;Hwang, Kyeong Mo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2015
  • Local wall thinning and integrity degradation caused by several mechanisms, such as flow accelerated corrosion, cavitation, flashing and/or liquid droplet impingement, is a main concern in secondary steam cycle piping system of nuclear power plants in terms of safety and operability. Thinned pipe management program (TPMP) has being developed and optimized to reduce the possibility of unplanned shutdown and/or power reduction due to pipe failure caused by wall thinning. In this paper, newest technologies, standards and regulations related to the integrity assessment, repair and replacement of thinned pipe component are reviewed. And technical improvement items in TPMP to secure the reliability and effectiveness are also presented.

Shear strength of Cast-In Place R/C Infill Shear Wall (현장타설 철근콘크리트 끼움벽의 전단강도)

  • Choi Chang Sik;Lee Hye Yeon;Kim Sun Woo;Yun Hyun Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.247-250
    • /
    • 2005
  • The aim of Cast-In-Place(CIP) method is to upgrade the strength, ductility and stiffness of the structure to the required level. The main objective of this research is to investigate the shear and the flexural strength of reinforced concrete frames infilled with CIP reinforced concrete wall. For this three 1/3 scale, one-bay, one story reinforced concrete infill wall were tested under reversed cyclic loading simulating the seismic effect. Results of tests of CIP shear wall were reviewed to evaluate the current design provisions and to establish the feasible retrofitting method.

  • PDF